CVE-2018-0293 (GCVE-0-2018-0293)
Vulnerability from cvelistv5 – Published: 2018-06-20 21:00 – Updated: 2024-11-29 15:02| URL | Tags |
|---|---|
| http://www.securityfocus.com/bid/104520 | vdb-entryx_refsource_BID |
| https://tools.cisco.com/security/center/content/C… | x_refsource_CONFIRM |
| http://www.securitytracker.com/id/1041169 | vdb-entryx_refsource_SECTRACK |
| Vendor | Product | Version | CPE status | |
|---|---|---|---|---|
| n/a | Cisco NX-OS unknown |
Affected:
Cisco NX-OS unknown
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T03:21:15.268Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "104520",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/104520"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20180620-nxosrbac"
},
{
"name": "1041169",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK",
"x_transferred"
],
"url": "http://www.securitytracker.com/id/1041169"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2018-0293",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-29T14:42:16.060197Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-29T15:02:28.459Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Cisco NX-OS unknown",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Cisco NX-OS unknown"
}
]
}
],
"datePublic": "2018-06-20T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "A vulnerability in role-based access control (RBAC) for Cisco NX-OS Software could allow an authenticated, remote attacker to execute CLI commands that should be restricted for a nonadministrative user. The attacker would have to possess valid user credentials for the device. The vulnerability is due to incorrect RBAC privilege assignment for certain CLI commands. An attacker could exploit this vulnerability by authenticating to a device as a nonadministrative user and executing specific commands from the CLI. An exploit could allow the attacker to run commands that should be restricted to administrative users. These commands could modify the configuration or boot image on the device. This vulnerability affects MDS 9000 Series Multilayer Switches, Nexus 2000 Series Switches, Nexus 3000 Series Switches, Nexus 3500 Platform Switches, Nexus 3600 Platform Switches, Nexus 5500 Platform Switches, Nexus 5600 Platform Switches, Nexus 6000 Series Switches, Nexus 7000 Series Switches, Nexus 7700 Series Switches, Nexus 9000 Series Switches in standalone NX-OS mode, Nexus 9500 R-Series Line Cards and Fabric Modules. Cisco Bug IDs: CSCvd77904."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-264",
"description": "CWE-264",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-06-23T09:57:01.000Z",
"orgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
"shortName": "cisco"
},
"references": [
{
"name": "104520",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/104520"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20180620-nxosrbac"
},
{
"name": "1041169",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK"
],
"url": "http://www.securitytracker.com/id/1041169"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "psirt@cisco.com",
"ID": "CVE-2018-0293",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Cisco NX-OS unknown",
"version": {
"version_data": [
{
"version_value": "Cisco NX-OS unknown"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability in role-based access control (RBAC) for Cisco NX-OS Software could allow an authenticated, remote attacker to execute CLI commands that should be restricted for a nonadministrative user. The attacker would have to possess valid user credentials for the device. The vulnerability is due to incorrect RBAC privilege assignment for certain CLI commands. An attacker could exploit this vulnerability by authenticating to a device as a nonadministrative user and executing specific commands from the CLI. An exploit could allow the attacker to run commands that should be restricted to administrative users. These commands could modify the configuration or boot image on the device. This vulnerability affects MDS 9000 Series Multilayer Switches, Nexus 2000 Series Switches, Nexus 3000 Series Switches, Nexus 3500 Platform Switches, Nexus 3600 Platform Switches, Nexus 5500 Platform Switches, Nexus 5600 Platform Switches, Nexus 6000 Series Switches, Nexus 7000 Series Switches, Nexus 7700 Series Switches, Nexus 9000 Series Switches in standalone NX-OS mode, Nexus 9500 R-Series Line Cards and Fabric Modules. Cisco Bug IDs: CSCvd77904."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-264"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "104520",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/104520"
},
{
"name": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20180620-nxosrbac",
"refsource": "CONFIRM",
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20180620-nxosrbac"
},
{
"name": "1041169",
"refsource": "SECTRACK",
"url": "http://www.securitytracker.com/id/1041169"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
"assignerShortName": "cisco",
"cveId": "CVE-2018-0293",
"datePublished": "2018-06-20T21:00:00.000Z",
"dateReserved": "2017-11-27T00:00:00.000Z",
"dateUpdated": "2024-11-29T15:02:28.459Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2018-0293",
"date": "2026-11-16",
"epss": "0.04673",
"percentile": "0.91915"
},
"nvd": {
"cve": {
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:cisco:nx-os:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D75479AD-9847-497C-9438-AA82D91B6F71",
"versionEndExcluding": "7.3\\(3\\)n1\\(1\\)",
"versionStartIncluding": "6.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:cisco:nexus_5000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4F2B1E07-8519-4F58-9048-81ABA12E01DC",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_5010:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E275D31F-4FA1-428E-AB4A-D2802FF0CF1A",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_5020:-:*:*:*:*:*:*:*",
"matchCriteriaId": "BA7F5823-41A8-47C8-A154-02C6C31EF76A",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_5548p:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E5519EA9-1236-4F51-9974-E3FC1B26B5D2",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_5548up:-:*:*:*:*:*:*:*",
"matchCriteriaId": "CB0A3B06-8B25-4CD3-AFA9-5F928B1042F4",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_5596t:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1766443C-1C5A-486E-A36F-D3045F364D78",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_5596up:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DC4D4403-F93B-4CC8-B75F-7A5B03FEDD85",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_56128p:-:*:*:*:*:*:*:*",
"matchCriteriaId": "ABB6E612-4246-4408-B3F6-B31E771F5ACB",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_5624q:-:*:*:*:*:*:*:*",
"matchCriteriaId": "91B129B2-2B31-4DE0-9F83-CC6E0C8729A0",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_5648q:-:*:*:*:*:*:*:*",
"matchCriteriaId": "3CBD3CD0-B542-4B23-9C9D-061643BE44E8",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_5672up:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A22A2647-A4C0-4681-BBC5-D95ADBAA0457",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_5696q:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B2BB1A3A-668C-4B0D-8AC2-6B4758B3420B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:cisco:nx-os:7.3\\(2\\)n1\\(0.395\\):*:*:*:*:*:*:*",
"matchCriteriaId": "0B836C06-16D8-4E1E-B607-F0EB31D87118",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:cisco:nx-os:8.1\\(0.112\\)s0:*:*:*:*:*:*:*",
"matchCriteriaId": "BEB52480-4F01-42DD-AC30-2ABCEA105F4C",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:cisco:nexus_7000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "12180BEB-7F21-4FA7-ABD2-E9A8EA7340F3",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_7700:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DD7A4B4B-3BB1-4A4D-911E-C4EEF01BBC45",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:cisco:nx-os:*:*:*:*:*:*:*:*",
"matchCriteriaId": "15C899EF-A64F-4FD8-851C-1D4E2929BAF4",
"versionEndExcluding": "7.0\\(3\\)i7\\(1\\)",
"versionStartIncluding": "7.0\\(3\\)i4",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:cisco:nexus_92160yc-x:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4283E433-7F8C-4410-B565-471415445811",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_92304qc:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D5B2E4C1-2627-4B9D-8E92-4B483F647651",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_9236c:-:*:*:*:*:*:*:*",
"matchCriteriaId": "11411BFD-3F4D-4309-AB35-A3629A360FB0",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_9272q:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E663DE91-C86D-48DC-B771-FA72A8DF7A7C",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_93108tc-ex:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A90184B3-C82F-4CE5-B2AD-97D5E4690871",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_93120tx:-:*:*:*:*:*:*:*",
"matchCriteriaId": "07DE6F63-2C7D-415B-8C34-01EC05C062F3",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_93128tx:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F423E45D-A6DD-4305-9C6A-EAB26293E53A",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_93180yc-ex:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F70D81F1-8B12-4474-9060-B4934D8A3873",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_9332pq:-:*:*:*:*:*:*:*",
"matchCriteriaId": "113772B6-E9D2-4094-9468-3F4E1A87D07D",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_9372px:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4364ADB9-8162-451D-806A-B98924E6B2CF",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_9372tx:-:*:*:*:*:*:*:*",
"matchCriteriaId": "49E0371B-FDE2-473C-AA59-47E1269D050F",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_9396px:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1BC5293E-F2B4-46DC-85DA-167EA323FCFD",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_9396tx:-:*:*:*:*:*:*:*",
"matchCriteriaId": "EA022E77-6557-4A33-9A3A-D028E2DB669A",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_9504:-:*:*:*:*:*:*:*",
"matchCriteriaId": "768BE390-5ED5-48A7-9E80-C4DE8BA979B1",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_9508:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DDC2F709-AFBE-48EA-A3A2-DA1134534FB6",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_9516:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7E02DC82-0D26-436F-BA64-73C958932B0A",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_n9k-c9508-fm-r:-:*:*:*:*:*:*:*",
"matchCriteriaId": "0FD46BDD-4755-46DD-9F83-B2B589B09417",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_n9k-x9636c-r:-:*:*:*:*:*:*:*",
"matchCriteriaId": "0603E231-14E0-4224-898F-ED61641F7403",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_n9k-x9636q-r:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FE3EB1F2-F964-4D4E-BDE7-8E6805105152",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:cisco:nx-os:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C90753E4-EDC5-49F6-A7E0-C96BEFDE877A",
"versionEndExcluding": "7.0\\(3\\)i7\\(2\\)",
"versionStartIncluding": "6.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:cisco:nexus_172tq-xl:-:*:*:*:*:*:*:*",
"matchCriteriaId": "38AC6D08-C547-44A3-AC77-A63DB58E4889",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_3016:-:*:*:*:*:*:*:*",
"matchCriteriaId": "528ED62B-D739-4E06-AC64-B506FD73BBAB",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_3048:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FC2A6C31-438A-4CF5-A3F3-364B1672EB7D",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_3064-32t:-:*:*:*:*:*:*:*",
"matchCriteriaId": "09AC2BAD-F536-48D0-A2F0-D4E290519EB6",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_3064-t:-:*:*:*:*:*:*:*",
"matchCriteriaId": "65CB7F6D-A82B-4A31-BFAC-FF4A4B8DF9C1",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_3064-x:-:*:*:*:*:*:*:*",
"matchCriteriaId": "ECC4FFCC-E886-49BC-9737-5B5BA2AAB14B",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_3100-v:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A8FF2EC4-0C09-4C00-9956-A2A4A894F63D",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_31128pq:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F4226DA0-9371-401C-8247-E6E636A116C3",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_3132c-z:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7664666F-BCE4-4799-AEEA-3A73E6AD33F4",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_3132q:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D3DBBFE9-835C-4411-8492-6006E74BAC65",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_3132q-x:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C97C29EE-9426-4BBE-8D84-AB5FF748703D",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_3132q-xl:-:*:*:*:*:*:*:*",
"matchCriteriaId": "8F43B770-D96C-44EA-BC12-9F39FC4317B9",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_3164q:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FA782EB3-E8E6-4DCF-B39C-B3CBD46E4384",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_3172pq:-:*:*:*:*:*:*:*",
"matchCriteriaId": "CED628B5-97A8-4B26-AA40-BEC854982157",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_3172pq-xl:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7BB9DD73-E31D-4921-A6D6-E14E04703588",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_3172tq:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4532F513-0543-4960-9877-01F23CA7BA1B",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_3172tq-32t:-:*:*:*:*:*:*:*",
"matchCriteriaId": "0B43502B-FD53-465A-B60F-6A359C6ACD99",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_3232c:-:*:*:*:*:*:*:*",
"matchCriteriaId": "652A2849-668D-4156-88FB-C19844A59F33",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_3264c-e:-:*:*:*:*:*:*:*",
"matchCriteriaId": "24FBE87B-8A4F-43A8-98A3-4A7D9C630937",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_3264q:-:*:*:*:*:*:*:*",
"matchCriteriaId": "6ACD09AC-8B28-4ACB-967B-AB3D450BC137",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_34180yc:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DC7286A7-780F-4A45-940A-4AD5C9D0F201",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_3524-x:-:*:*:*:*:*:*:*",
"matchCriteriaId": "10F80A72-AD54-4699-B8AE-82715F0B58E2",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_3524-xl:-:*:*:*:*:*:*:*",
"matchCriteriaId": "9354B6A2-D7D6-442E-BF4C-FE8A336D9E94",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_3548:-:*:*:*:*:*:*:*",
"matchCriteriaId": "088C0323-683A-44F5-8D42-FF6EC85D080E",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_3548-x:-:*:*:*:*:*:*:*",
"matchCriteriaId": "74CB4002-7636-4382-B33E-FBA060A13C34",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_3548-xl:-:*:*:*:*:*:*:*",
"matchCriteriaId": "10CEBF73-3EE0-459A-86C5-F8F6243FE27C",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_3636c-r:-:*:*:*:*:*:*:*",
"matchCriteriaId": "57572E4A-78D5-4D1A-938B-F05F01759612",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_c36180yc-r:-:*:*:*:*:*:*:*",
"matchCriteriaId": "0C9D4C48-4D01-4761-B2D8-F16E90F78560",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:cisco:nx-os:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D75479AD-9847-497C-9438-AA82D91B6F71",
"versionEndExcluding": "7.3\\(3\\)n1\\(1\\)",
"versionStartIncluding": "6.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:cisco:nexus_6001p:-:*:*:*:*:*:*:*",
"matchCriteriaId": "51EAD169-9036-496E-B740-45D79546F6D6",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:cisco:nexus_6001t:-:*:*:*:*:*:*:*",
"matchCriteriaId": "0E01F0DE-EA8A-451F-BADF-1A7A48B0C633",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:cisco:nx-os:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BD29D4BF-16C4-4F4B-A53A-0FF473BFBC12",
"versionEndExcluding": "8.1\\(1\\)",
"versionStartIncluding": "5.2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:cisco:mds_9100:-:*:*:*:*:*:*:*",
"matchCriteriaId": "54C0D908-D7BA-48C3-9963-14A3A32A2662",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability in role-based access control (RBAC) for Cisco NX-OS Software could allow an authenticated, remote attacker to execute CLI commands that should be restricted for a nonadministrative user. The attacker would have to possess valid user credentials for the device. The vulnerability is due to incorrect RBAC privilege assignment for certain CLI commands. An attacker could exploit this vulnerability by authenticating to a device as a nonadministrative user and executing specific commands from the CLI. An exploit could allow the attacker to run commands that should be restricted to administrative users. These commands could modify the configuration or boot image on the device. This vulnerability affects MDS 9000 Series Multilayer Switches, Nexus 2000 Series Switches, Nexus 3000 Series Switches, Nexus 3500 Platform Switches, Nexus 3600 Platform Switches, Nexus 5500 Platform Switches, Nexus 5600 Platform Switches, Nexus 6000 Series Switches, Nexus 7000 Series Switches, Nexus 7700 Series Switches, Nexus 9000 Series Switches in standalone NX-OS mode, Nexus 9500 R-Series Line Cards and Fabric Modules. Cisco Bug IDs: CSCvd77904."
},
{
"lang": "es",
"value": "Una vulnerabilidad en el control de acceso basado en roles (RBAC) del software Cisco NX-OS podr\u00eda permitir que un atacante remoto autenticado ejecute comandos de la interfaz de l\u00ednea de comandos que deber\u00edan estar restringidos para un usuario no administrativo. El atacante necesitar\u00eda tener credenciales de usuario v\u00e1lidas para el dispositivo. La vulnerabilidad se debe a una asignaci\u00f3n de privilegios RBAC incorrecta a ciertos comandos de la interfaz de l\u00ednea de comandos. Un atacante podr\u00eda explotar esta vulnerabilidad autentic\u00e1ndose en un dispositivo como usuario no administrativo y ejecutando comandos espec\u00edficos desde la interfaz de l\u00ednea de comandos. Su explotaci\u00f3n podr\u00eda permitir que el atacante ejecute comandos que deber\u00edan estar restringidos a los usuarios administrativos. Estos comandos podr\u00edan modificar la configuraci\u00f3n o cargar im\u00e1genes en el dispositivo. esta vulnerabilidad afecta a MDS 9000 Series Multilayer Switches, Nexus 2000 Series Switches, Nexus 3000 Series Switches, Nexus 3500 Platform Switches, Nexus 3600 Platform Switches, Nexus 5500 Platform Switches, Nexus 5600 Platform Switches, Nexus 6000 Series Switches, Nexus 7000 Series Switches, Nexus 7700 Series Switches, Nexus 9000 Series Switches en modo NX-OS independiente y los m\u00f3dulos Line Cards y Fabric de Nexus 9500 R-Series. Cisco Bug IDs: CSCvd77904."
}
],
"id": "CVE-2018-0293",
"lastModified": "2024-11-21T03:37:54.813",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "COMPLETE",
"baseScore": 9.0,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
},
"exploitabilityScore": 8.0,
"impactScore": 10.0,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2018-06-20T21:29:00.343",
"references": [
{
"source": "psirt@cisco.com",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://www.securityfocus.com/bid/104520"
},
{
"source": "psirt@cisco.com",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://www.securitytracker.com/id/1041169"
},
{
"source": "psirt@cisco.com",
"tags": [
"Vendor Advisory"
],
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20180620-nxosrbac"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://www.securityfocus.com/bid/104520"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://www.securitytracker.com/id/1041169"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20180620-nxosrbac"
}
],
"sourceIdentifier": "psirt@cisco.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-264"
}
],
"source": "psirt@cisco.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-78"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
},
"vulnrichment": {
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T03:21:15.268Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "104520",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/104520"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20180620-nxosrbac"
},
{
"name": "1041169",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK",
"x_transferred"
],
"url": "http://www.securitytracker.com/id/1041169"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2018-0293",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-29T14:42:16.060197Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-29T14:42:44.918Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Cisco NX-OS unknown",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Cisco NX-OS unknown"
}
]
}
],
"datePublic": "2018-06-20T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "A vulnerability in role-based access control (RBAC) for Cisco NX-OS Software could allow an authenticated, remote attacker to execute CLI commands that should be restricted for a nonadministrative user. The attacker would have to possess valid user credentials for the device. The vulnerability is due to incorrect RBAC privilege assignment for certain CLI commands. An attacker could exploit this vulnerability by authenticating to a device as a nonadministrative user and executing specific commands from the CLI. An exploit could allow the attacker to run commands that should be restricted to administrative users. These commands could modify the configuration or boot image on the device. This vulnerability affects MDS 9000 Series Multilayer Switches, Nexus 2000 Series Switches, Nexus 3000 Series Switches, Nexus 3500 Platform Switches, Nexus 3600 Platform Switches, Nexus 5500 Platform Switches, Nexus 5600 Platform Switches, Nexus 6000 Series Switches, Nexus 7000 Series Switches, Nexus 7700 Series Switches, Nexus 9000 Series Switches in standalone NX-OS mode, Nexus 9500 R-Series Line Cards and Fabric Modules. Cisco Bug IDs: CSCvd77904."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-264",
"description": "CWE-264",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-06-23T09:57:01.000Z",
"orgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
"shortName": "cisco"
},
"references": [
{
"name": "104520",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/104520"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20180620-nxosrbac"
},
{
"name": "1041169",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK"
],
"url": "http://www.securitytracker.com/id/1041169"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "psirt@cisco.com",
"ID": "CVE-2018-0293",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Cisco NX-OS unknown",
"version": {
"version_data": [
{
"version_value": "Cisco NX-OS unknown"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability in role-based access control (RBAC) for Cisco NX-OS Software could allow an authenticated, remote attacker to execute CLI commands that should be restricted for a nonadministrative user. The attacker would have to possess valid user credentials for the device. The vulnerability is due to incorrect RBAC privilege assignment for certain CLI commands. An attacker could exploit this vulnerability by authenticating to a device as a nonadministrative user and executing specific commands from the CLI. An exploit could allow the attacker to run commands that should be restricted to administrative users. These commands could modify the configuration or boot image on the device. This vulnerability affects MDS 9000 Series Multilayer Switches, Nexus 2000 Series Switches, Nexus 3000 Series Switches, Nexus 3500 Platform Switches, Nexus 3600 Platform Switches, Nexus 5500 Platform Switches, Nexus 5600 Platform Switches, Nexus 6000 Series Switches, Nexus 7000 Series Switches, Nexus 7700 Series Switches, Nexus 9000 Series Switches in standalone NX-OS mode, Nexus 9500 R-Series Line Cards and Fabric Modules. Cisco Bug IDs: CSCvd77904."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-264"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "104520",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/104520"
},
{
"name": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20180620-nxosrbac",
"refsource": "CONFIRM",
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20180620-nxosrbac"
},
{
"name": "1041169",
"refsource": "SECTRACK",
"url": "http://www.securitytracker.com/id/1041169"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
"assignerShortName": "cisco",
"cveId": "CVE-2018-0293",
"datePublished": "2018-06-20T21:00:00.000Z",
"dateReserved": "2017-11-27T00:00:00.000Z",
"dateUpdated": "2024-11-29T15:02:28.459Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.