CVE-2017-8958 (GCVE-0-2017-8958)
Vulnerability from cvelistv5 – Published: 2018-02-15 22:00 – Updated: 2024-09-16 19:10
VLAI?
Summary
A Remote Code Execution vulnerability in HPE Intelligent Management Center (iMC) PLAT version 7.3 E0504P04 and earlier was found.
Severity ?
No CVSS data available.
CWE
- Remote Code Execution
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Hewlett Packard Enterprise | Intelligent Management Center (iMC) PLAT |
Affected:
7.3 E0504P04 and earlier
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T16:55:21.686Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "101202",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/101202"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-hpesbhf03786en_us"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Intelligent Management Center (iMC) PLAT",
"vendor": "Hewlett Packard Enterprise",
"versions": [
{
"status": "affected",
"version": "7.3 E0504P04 and earlier"
}
]
}
],
"datePublic": "2017-10-05T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A Remote Code Execution vulnerability in HPE Intelligent Management Center (iMC) PLAT version 7.3 E0504P04 and earlier was found."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Remote Code Execution",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-02-16T15:57:01",
"orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"shortName": "hpe"
},
"references": [
{
"name": "101202",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/101202"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-hpesbhf03786en_us"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security-alert@hpe.com",
"DATE_PUBLIC": "2017-10-05T00:00:00",
"ID": "CVE-2017-8958",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Intelligent Management Center (iMC) PLAT",
"version": {
"version_data": [
{
"version_value": "7.3 E0504P04 and earlier"
}
]
}
}
]
},
"vendor_name": "Hewlett Packard Enterprise"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A Remote Code Execution vulnerability in HPE Intelligent Management Center (iMC) PLAT version 7.3 E0504P04 and earlier was found."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Remote Code Execution"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "101202",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/101202"
},
{
"name": "https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-hpesbhf03786en_us",
"refsource": "CONFIRM",
"url": "https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-hpesbhf03786en_us"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"assignerShortName": "hpe",
"cveId": "CVE-2017-8958",
"datePublished": "2018-02-15T22:00:00Z",
"dateReserved": "2017-05-15T00:00:00",
"dateUpdated": "2024-09-16T19:10:43.877Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"nvd": "{\"cve\":{\"id\":\"CVE-2017-8958\",\"sourceIdentifier\":\"security-alert@hpe.com\",\"published\":\"2018-02-15T22:29:08.293\",\"lastModified\":\"2024-11-21T03:35:04.347\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A Remote Code Execution vulnerability in HPE Intelligent Management Center (iMC) PLAT version 7.3 E0504P04 and earlier was found.\"},{\"lang\":\"es\",\"value\":\"Se ha encontrado una vulnerabilidad de ejecuci\u00f3n remota de c\u00f3digo en HPE Intelligent Management Center (iMC) PLAT 7.3 E0504P04 y anteriores.\"}],\"metrics\":{\"cvssMetricV30\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:C/I:C/A:C\",\"baseScore\":9.3,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":8.6,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-noinfo\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:hp:intelligent_management_center:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"7.3\",\"matchCriteriaId\":\"39293796-E695-4592-9E0E-0AAED065F515\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:hp:intelligent_management_center:7.3:e0504p04:*:*:*:*:*:*\",\"matchCriteriaId\":\"0FC4C972-D942-40A3-AFDE-A3A2B34416BB\"}]}]}],\"references\":[{\"url\":\"http://www.securityfocus.com/bid/101202\",\"source\":\"security-alert@hpe.com\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-hpesbhf03786en_us\",\"source\":\"security-alert@hpe.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"http://www.securityfocus.com/bid/101202\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-hpesbhf03786en_us\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}"
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…