CVE-2017-8196 (GCVE-0-2017-8196)
Vulnerability from cvelistv5 – Published: 2017-11-22 19:00 – Updated: 2024-09-16 16:18
VLAI?
Summary
FusionSphere V100R006C00SPC102(NFV) has an incorrect authorization vulnerability. An authenticated attacker could execute commands that he/she should have had no permission to perform, thereby querying, modifying, and deleting certain service data and making the service unavailable.
Severity ?
No CVSS data available.
CWE
- incorrect authorization
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Huawei Technologies Co., Ltd. | FusionSphere |
Affected:
V100R006C00SPC102(NFV)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T16:27:23.370Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.huawei.com/en/psirt/security-advisories/huawei-sa-20170913-01-fusionsphere-en"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "FusionSphere",
"vendor": "Huawei Technologies Co., Ltd.",
"versions": [
{
"status": "affected",
"version": "V100R006C00SPC102(NFV)"
}
]
}
],
"datePublic": "2017-11-15T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "FusionSphere V100R006C00SPC102(NFV) has an incorrect authorization vulnerability. An authenticated attacker could execute commands that he/she should have had no permission to perform, thereby querying, modifying, and deleting certain service data and making the service unavailable."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "incorrect authorization",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2017-11-22T18:57:01",
"orgId": "25ac1063-e409-4190-8079-24548c77ea2e",
"shortName": "huawei"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.huawei.com/en/psirt/security-advisories/huawei-sa-20170913-01-fusionsphere-en"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "psirt@huawei.com",
"DATE_PUBLIC": "2017-11-15T00:00:00",
"ID": "CVE-2017-8196",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "FusionSphere",
"version": {
"version_data": [
{
"version_value": "V100R006C00SPC102(NFV)"
}
]
}
}
]
},
"vendor_name": "Huawei Technologies Co., Ltd."
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "FusionSphere V100R006C00SPC102(NFV) has an incorrect authorization vulnerability. An authenticated attacker could execute commands that he/she should have had no permission to perform, thereby querying, modifying, and deleting certain service data and making the service unavailable."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "incorrect authorization"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://www.huawei.com/en/psirt/security-advisories/huawei-sa-20170913-01-fusionsphere-en",
"refsource": "CONFIRM",
"url": "http://www.huawei.com/en/psirt/security-advisories/huawei-sa-20170913-01-fusionsphere-en"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "25ac1063-e409-4190-8079-24548c77ea2e",
"assignerShortName": "huawei",
"cveId": "CVE-2017-8196",
"datePublished": "2017-11-22T19:00:00Z",
"dateReserved": "2017-04-25T00:00:00",
"dateUpdated": "2024-09-16T16:18:54.511Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"nvd": "{\"cve\":{\"id\":\"CVE-2017-8196\",\"sourceIdentifier\":\"psirt@huawei.com\",\"published\":\"2017-11-22T19:29:04.867\",\"lastModified\":\"2025-04-20T01:37:25.860\",\"vulnStatus\":\"Deferred\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"FusionSphere V100R006C00SPC102(NFV) has an incorrect authorization vulnerability. An authenticated attacker could execute commands that he/she should have had no permission to perform, thereby querying, modifying, and deleting certain service data and making the service unavailable.\"},{\"lang\":\"es\",\"value\":\"FusionSphere V100R006C00SPC102(NFV) tiene una vulnerabilidad de autorizaci\u00f3n incorrecta. Un atacante autenticado podr\u00eda ejecutar comandos que no deber\u00eda tener permiso para realizar, pudiendo consultar, modificar y eliminar determinados datos del servicio y hacer que el servicio no est\u00e9 disponible.\"}],\"metrics\":{\"cvssMetricV30\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L\",\"baseScore\":4.2,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"LOW\"},\"exploitabilityScore\":0.8,\"impactScore\":3.4}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:L/AC:L/Au:N/C:P/I:P/A:P\",\"baseScore\":4.6,\"accessVector\":\"LOCAL\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":3.9,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-863\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:huawei:fusionsphere:v100r006c00spc102\\\\(nfv\\\\):*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B4B6C5C1-9597-4644-BB52-A464CDF976A9\"}]}]}],\"references\":[{\"url\":\"http://www.huawei.com/en/psirt/security-advisories/huawei-sa-20170913-01-fusionsphere-en\",\"source\":\"psirt@huawei.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"http://www.huawei.com/en/psirt/security-advisories/huawei-sa-20170913-01-fusionsphere-en\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}"
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…