CVE-2017-6754 (GCVE-0-2017-6754)

Vulnerability from cvelistv5 – Published: 2017-08-07 06:00 – Updated: 2024-08-05 15:41
VLAI?
Summary
A vulnerability in the web-based management interface of the Cisco Smart Net Total Care (SNTC) Software Collector Appliance 3.11 could allow an authenticated, remote attacker to perform a read-only, blind SQL injection attack, which could allow the attacker to compromise the confidentiality of the system through SQL timing attacks. The vulnerability is due to insufficient input validation of certain user-supplied fields that are subsequently used by the affected software to build SQL queries. An attacker could exploit this vulnerability by submitting crafted URLs, which are designed to exploit the vulnerability, to the affected software. To execute an attack successfully, the attacker would need to submit a number of requests to the affected software. A successful exploit could allow the attacker to determine the presence of values in the SQL database of the affected software. Cisco Bug IDs: CSCvf07617.
Severity ?
No CVSS data available.
CWE
Assigner
Impacted products
Vendor Product Version
n/a Cisco Smart Net Total Care Software Collector Appliance Affected: Cisco Smart Net Total Care Software Collector Appliance
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T15:41:17.116Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://quickview.cloudapps.cisco.com/quickview/bug/CSCvf07617"
          },
          {
            "name": "100126",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/100126"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20170802-sntc"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Cisco Smart Net Total Care Software Collector Appliance",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Cisco Smart Net Total Care Software Collector Appliance"
            }
          ]
        }
      ],
      "datePublic": "2017-08-07T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability in the web-based management interface of the Cisco Smart Net Total Care (SNTC) Software Collector Appliance 3.11 could allow an authenticated, remote attacker to perform a read-only, blind SQL injection attack, which could allow the attacker to compromise the confidentiality of the system through SQL timing attacks. The vulnerability is due to insufficient input validation of certain user-supplied fields that are subsequently used by the affected software to build SQL queries. An attacker could exploit this vulnerability by submitting crafted URLs, which are designed to exploit the vulnerability, to the affected software. To execute an attack successfully, the attacker would need to submit a number of requests to the affected software. A successful exploit could allow the attacker to determine the presence of values in the SQL database of the affected software. Cisco Bug IDs: CSCvf07617."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-08-07T09:57:02",
        "orgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
        "shortName": "cisco"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://quickview.cloudapps.cisco.com/quickview/bug/CSCvf07617"
        },
        {
          "name": "100126",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/100126"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20170802-sntc"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@cisco.com",
          "ID": "CVE-2017-6754",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Cisco Smart Net Total Care Software Collector Appliance",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Cisco Smart Net Total Care Software Collector Appliance"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability in the web-based management interface of the Cisco Smart Net Total Care (SNTC) Software Collector Appliance 3.11 could allow an authenticated, remote attacker to perform a read-only, blind SQL injection attack, which could allow the attacker to compromise the confidentiality of the system through SQL timing attacks. The vulnerability is due to insufficient input validation of certain user-supplied fields that are subsequently used by the affected software to build SQL queries. An attacker could exploit this vulnerability by submitting crafted URLs, which are designed to exploit the vulnerability, to the affected software. To execute an attack successfully, the attacker would need to submit a number of requests to the affected software. A successful exploit could allow the attacker to determine the presence of values in the SQL database of the affected software. Cisco Bug IDs: CSCvf07617."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-89"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://quickview.cloudapps.cisco.com/quickview/bug/CSCvf07617",
              "refsource": "CONFIRM",
              "url": "https://quickview.cloudapps.cisco.com/quickview/bug/CSCvf07617"
            },
            {
              "name": "100126",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/100126"
            },
            {
              "name": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20170802-sntc",
              "refsource": "CONFIRM",
              "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20170802-sntc"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
    "assignerShortName": "cisco",
    "cveId": "CVE-2017-6754",
    "datePublished": "2017-08-07T06:00:00",
    "dateReserved": "2017-03-09T00:00:00",
    "dateUpdated": "2024-08-05T15:41:17.116Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2017-6754\",\"sourceIdentifier\":\"psirt@cisco.com\",\"published\":\"2017-08-07T06:29:00.417\",\"lastModified\":\"2025-04-20T01:37:25.860\",\"vulnStatus\":\"Deferred\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability in the web-based management interface of the Cisco Smart Net Total Care (SNTC) Software Collector Appliance 3.11 could allow an authenticated, remote attacker to perform a read-only, blind SQL injection attack, which could allow the attacker to compromise the confidentiality of the system through SQL timing attacks. The vulnerability is due to insufficient input validation of certain user-supplied fields that are subsequently used by the affected software to build SQL queries. An attacker could exploit this vulnerability by submitting crafted URLs, which are designed to exploit the vulnerability, to the affected software. To execute an attack successfully, the attacker would need to submit a number of requests to the affected software. A successful exploit could allow the attacker to determine the presence of values in the SQL database of the affected software. Cisco Bug IDs: CSCvf07617.\"},{\"lang\":\"es\",\"value\":\"Una vulnerabilidad en la interfaz de gesti\u00f3n basada en web de Cisco Smart Net Total Care (SNTC) Software Collector Appliance 3.11 podr\u00eda permitir que un atacante remoto autenticado realice un ataque ciego de s\u00f3lo lectura de inyecci\u00f3n SQL, lo que har\u00eda que este comprometiese la confidencialidad del sistema mediante ataques SQL basados en tiempo. La vulnerabilidad se debe a que no se validan lo suficiente los campos de entrada de datos de usuario que son, posteriormente, empleados por el software afectado para realizar consultas SQL. Un atacante podr\u00eda explotar esta vulnerabilidad enviando al software afectado URL manipuladas dise\u00f1adas para este fin. Para llevar a cabo este ataque de forma exitosa, el atacante necesitar\u00eda enviar una serie de peticiones al software afectado. Si se realiza correctamente, esta vulnerabilidad podr\u00eda permitir que el atacante determine la presencia de valores en la base de datos SQL del software afectado. Cisco Bug IDs: CSCvf07617.\"}],\"metrics\":{\"cvssMetricV30\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":6.5,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.8,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:S/C:P/I:N/A:N\",\"baseScore\":4.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"psirt@cisco.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-89\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-89\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:cisco:smart_net_total_care_collector_appliance:3.11:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"07DA489C-B051-45DB-B068-96E09B7E57BF\"}]}]}],\"references\":[{\"url\":\"http://www.securityfocus.com/bid/100126\",\"source\":\"psirt@cisco.com\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://quickview.cloudapps.cisco.com/quickview/bug/CSCvf07617\",\"source\":\"psirt@cisco.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20170802-sntc\",\"source\":\"psirt@cisco.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"http://www.securityfocus.com/bid/100126\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://quickview.cloudapps.cisco.com/quickview/bug/CSCvf07617\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20170802-sntc\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…