CVE-2016-4391 (GCVE-0-2016-4391)

Vulnerability from cvelistv5 – Published: 2018-08-06 20:00 – Updated: 2024-08-06 00:25
VLAI
Summary
A remote code execution security vulnerability has been identified in all versions of the HP ArcSight WINC Connector prior to v7.3.0.
CWE
  • remote code execution
Assigner
References
URL Tags
https://support.hpe.com/hpsc/doc/public/display?d… x_refsource_CONFIRM
http://www.securityfocus.com/bid/93789 vdb-entryx_refsource_BID
http://www.securitytracker.com/id/1037068 vdb-entryx_refsource_SECTRACK
Impacted products
Vendor Product Version CPE status
Hewlett Packard Enterprise HP ArcSight WINC Connector Affected: all versions prior to v7.3.0
guessed Create a notification for this product.
Date Public
2016-10-19 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T00:25:14.575Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-c05313743"
          },
          {
            "name": "93789",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/93789"
          },
          {
            "name": "1037068",
            "tags": [
              "vdb-entry",
              "x_refsource_SECTRACK",
              "x_transferred"
            ],
            "url": "http://www.securitytracker.com/id/1037068"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "HP ArcSight WINC Connector",
          "vendor": "Hewlett Packard Enterprise",
          "versions": [
            {
              "status": "affected",
              "version": "all versions prior to v7.3.0"
            }
          ]
        }
      ],
      "datePublic": "2016-10-19T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "A remote code execution security vulnerability has been identified in all versions of the HP ArcSight WINC Connector prior to v7.3.0."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "remote code execution",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-08-07T09:57:01.000Z",
        "orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
        "shortName": "hpe"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-c05313743"
        },
        {
          "name": "93789",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/93789"
        },
        {
          "name": "1037068",
          "tags": [
            "vdb-entry",
            "x_refsource_SECTRACK"
          ],
          "url": "http://www.securitytracker.com/id/1037068"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security-alert@hpe.com",
          "ID": "CVE-2016-4391",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "HP ArcSight WINC Connector",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "all versions prior to v7.3.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Hewlett Packard Enterprise"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A remote code execution security vulnerability has been identified in all versions of the HP ArcSight WINC Connector prior to v7.3.0."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "remote code execution"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-c05313743",
              "refsource": "CONFIRM",
              "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-c05313743"
            },
            {
              "name": "93789",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/93789"
            },
            {
              "name": "1037068",
              "refsource": "SECTRACK",
              "url": "http://www.securitytracker.com/id/1037068"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
    "assignerShortName": "hpe",
    "cveId": "CVE-2016-4391",
    "datePublished": "2018-08-06T20:00:00.000Z",
    "dateReserved": "2016-04-29T00:00:00.000Z",
    "dateUpdated": "2024-08-06T00:25:14.575Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2016-4391",
      "date": "2026-09-23",
      "epss": "0.20433",
      "percentile": "0.97379"
    },
    "nvd": {
      "cve": {
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:a:hp:arcsight_winc_connector:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "89172A67-ED5C-4C37-A5B1-81E1A46DBE67",
                    "versionEndExcluding": "7.3.0",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ]
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "A remote code execution security vulnerability has been identified in all versions of the HP ArcSight WINC Connector prior to v7.3.0."
          },
          {
            "lang": "es",
            "value": "Se ha identificado una vulnerabilidad de seguridad de ejecuci\u00f3n remota de c\u00f3digo en todas las versiones de HP ArcSight WINC Connector en versiones anteriores a la v7.3.0."
          }
        ],
        "id": "CVE-2016-4391",
        "lastModified": "2024-11-21T02:52:01.200",
        "metrics": {
          "cvssMetricV2": [
            {
              "acInsufInfo": false,
              "baseSeverity": "HIGH",
              "cvssData": {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "availabilityImpact": "PARTIAL",
                "baseScore": 7.5,
                "confidentialityImpact": "PARTIAL",
                "integrityImpact": "PARTIAL",
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              },
              "exploitabilityScore": 10.0,
              "impactScore": 6.4,
              "obtainAllPrivilege": false,
              "obtainOtherPrivilege": false,
              "obtainUserPrivilege": false,
              "source": "nvd@nist.gov",
              "type": "Primary",
              "userInteractionRequired": false
            }
          ],
          "cvssMetricV30": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              },
              "exploitabilityScore": 3.9,
              "impactScore": 5.9,
              "source": "nvd@nist.gov",
              "type": "Primary"
            }
          ]
        },
        "published": "2018-08-06T20:29:00.227",
        "references": [
          {
            "source": "security-alert@hpe.com",
            "tags": [
              "Third Party Advisory",
              "VDB Entry"
            ],
            "url": "http://www.securityfocus.com/bid/93789"
          },
          {
            "source": "security-alert@hpe.com",
            "tags": [
              "Third Party Advisory",
              "VDB Entry"
            ],
            "url": "http://www.securitytracker.com/id/1037068"
          },
          {
            "source": "security-alert@hpe.com",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-c05313743"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Third Party Advisory",
              "VDB Entry"
            ],
            "url": "http://www.securityfocus.com/bid/93789"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Third Party Advisory",
              "VDB Entry"
            ],
            "url": "http://www.securitytracker.com/id/1037068"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-c05313743"
          }
        ],
        "sourceIdentifier": "security-alert@hpe.com",
        "vulnStatus": "Modified",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-94"
              }
            ],
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      }
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…