CVE-2015-3976 (GCVE-0-2015-3976)
Vulnerability from cvelistv5 – Published: 2017-08-28 15:00 – Updated: 2025-11-04 23:33| URL | Tags |
|---|---|
| https://www.cisa.gov/news-events/ics-advisories/i… | |
| http://www.gedigitalenergy.com/products/support/m… | x_refsource_CONFIRM |
| https://github.com/cisagov/CSAF/blob/develop/csaf… | |
| https://ics-cert.us-cert.gov/advisories/ICSA-15-013-04A | x_refsource_MISCx_transferred |
| Vendor | Product | Version | CPE status | |
|---|---|---|---|---|
| GE | Multilink ML800/1200/1600/2400 |
Affected:
0 , ≤ 4.2.1
(custom)
|
guessed | |
| GE | ML810/3000/3100 series switch |
Affected:
0 , ≤ 5.2.0
(custom)
|
guessed |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T06:04:02.453Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-013-04A"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Multilink ML800/1200/1600/2400",
"vendor": "GE",
"versions": [
{
"lessThanOrEqual": "4.2.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ML810/3000/3100 series switch",
"vendor": "GE",
"versions": [
{
"lessThanOrEqual": "5.2.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Eireann Leverett of IOActive"
}
],
"datePublic": "2015-01-13T07:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003e\n\nCross-site scripting (XSS) vulnerability in GE Multilink ML810/3000/3100 series switch 5.2.0 and earlier, and GE Multilink ML800/1200/1600/2400 4.2.1 and earlier.\n\n\u003c/p\u003e"
}
],
"value": "Cross-site scripting (XSS) vulnerability in GE Multilink ML810/3000/3100 series switch 5.2.0 and earlier, and GE Multilink ML800/1200/1600/2400 4.2.1 and earlier."
}
],
"metrics": [
{
"cvssV2_0": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "NONE",
"baseScore": 6.8,
"confidentialityImpact": "NONE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:N/AC:L/Au:S/C:N/I:C/A:N",
"version": "2.0"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-11-04T23:33:49.742Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-15-013-04a"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.gedigitalenergy.com/products/support/multilink/MLSB1214.pdf"
},
{
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2015/icsa-15-013-04a.json"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eGE recommends users update switch firmware to the \nlatest published version to resolve these vulnerabilities. The new \nfirmware will enable new keys to be calculated and exchanged, resolve \nthe slow data transfer and potential denial of service, and prevent the identified \ncross-site scripting vulnerabilities. The latest firmware is Version \n5.3.2 for the ML800, ML1200, ML1600 and ML2400 and Version 5.3.2-3K for \nthe ML810, ML3000, and ML3100. This firmware is available through the \n\u201cResources/Software\u201d link in the product web sites at \n\u003ca target=\"_blank\" rel=\"nofollow\" href=\"http://www.gedigitalenergy.com\"\u003ehttp://www.gedigitalenergy.com\u003c/a\u003e. This firmware is also available through \nthe EnerVista Launchpad device management tool.\u003c/p\u003e\n\u003cp\u003eGE recommends updating the switch over a serial connection to prevent an attacker from capturing the new key.\u003c/p\u003e\n\u003cp\u003ePlease refer to the GE advisory for specific information on how to \ninstall the firmware and change RSA key. The GE advisory is available \nat:\u003c/p\u003e\n\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.gedigitalenergy.com/products/support/multilink/MLSB0415.pdf\"\u003ehttps://www.gedigitalenergy.com/products/support/multilink/MLSB0415.pdf\u003c/a\u003e\u003c/p\u003e\n\n\u003cbr\u003e"
}
],
"value": "GE recommends users update switch firmware to the \nlatest published version to resolve these vulnerabilities. The new \nfirmware will enable new keys to be calculated and exchanged, resolve \nthe slow data transfer and potential denial of service, and prevent the identified \ncross-site scripting vulnerabilities. The latest firmware is Version \n5.3.2 for the ML800, ML1200, ML1600 and ML2400 and Version 5.3.2-3K for \nthe ML810, ML3000, and ML3100. This firmware is available through the \n\u201cResources/Software\u201d link in the product web sites at \n http://www.gedigitalenergy.com . This firmware is also available through \nthe EnerVista Launchpad device management tool.\n\n\nGE recommends updating the switch over a serial connection to prevent an attacker from capturing the new key.\n\n\nPlease refer to the GE advisory for specific information on how to \ninstall the firmware and change RSA key. The GE advisory is available \nat:\n\n\n https://www.gedigitalenergy.com/products/support/multilink/MLSB0415.pdf"
}
],
"source": {
"advisory": "ICSA-15-013-04",
"discovery": "EXTERNAL"
},
"title": "GE Multilink Cross-site Scripting",
"x_generator": {
"engine": "Vulnogram 0.5.0"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2014-5418",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "GE Multilink ML800, ML1200, ML1600, and ML2400 switches with firmware 4.2.1 and earlier and Multilink ML810, ML3000, and ML3100 switches with firmware 5.2.0 and earlier allow remote attackers to cause a denial of service (resource consumption or reboot) via crafted packets."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-15-013-04",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-013-04"
},
{
"name": "http://www.gedigitalenergy.com/products/support/multilink/MLSB1214.pdf",
"refsource": "CONFIRM",
"url": "http://www.gedigitalenergy.com/products/support/multilink/MLSB1214.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2015-3976",
"datePublished": "2017-08-28T15:00:00.000Z",
"dateReserved": "2015-05-12T00:00:00.000Z",
"dateUpdated": "2025-11-04T23:33:49.742Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2015-3976",
"date": "2026-11-17",
"epss": "0.0119",
"percentile": "0.68474"
},
"nvd": {
"cve": {
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ge:multilink_ml810_firmware:5.2.0:*:*:*:*:*:*:*",
"matchCriteriaId": "26502C62-8445-45C8-B099-02513595D002",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ge:multilink_ml810:-:*:*:*:*:*:*:*",
"matchCriteriaId": "81DC26E5-D3D7-41C6-B654-B06FA0461451",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ge:multilink_ml3000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F8CCA289-8E58-41E9-9AD3-860A6B373EE3",
"versionEndIncluding": "5.2.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ge:multilink_ml3000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7EE40202-1D8F-406E-8281-B67DCF5E8501",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ge:multilink_ml3100_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "339C1069-C126-4840-92DC-0DBE17FD764C",
"versionEndIncluding": "5.2.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ge:multilink_ml3100:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D72F9922-A473-4076-91E3-CF3899C179D7",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ge:multilink_ml800_firmware:4.2.1:*:*:*:*:*:*:*",
"matchCriteriaId": "83DE9D2A-3A96-4051-9C69-0B0C9EA26EE4",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ge:multilink_ml800:-:*:*:*:*:*:*:*",
"matchCriteriaId": "9A00E85C-1B21-43F7-8323-F759216BFB90",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ge:multilink_ml1200_firmware:4.2.1:*:*:*:*:*:*:*",
"matchCriteriaId": "D8A95DAC-C62C-451A-9613-123FECFB9627",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ge:multilink_ml1200:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1179F179-510A-4A97-8365-B81C0E0FC605",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ge:multilink_ml1600_firmware:4.2.1:*:*:*:*:*:*:*",
"matchCriteriaId": "256CB390-1BAB-41E3-89AA-98BA88114D84",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ge:multilink_ml1600:-:*:*:*:*:*:*:*",
"matchCriteriaId": "620703E4-1D78-44CB-B353-517A8AB2A815",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ge:multilink_ml2400_firmware:4.2.1:*:*:*:*:*:*:*",
"matchCriteriaId": "EB917F77-2933-4877-A8A2-C6364D6DCE0A",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:ge:multilink_ml2400:-:*:*:*:*:*:*:*",
"matchCriteriaId": "426A283A-540C-43F2-8397-52668BADDEB8",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Cross-site scripting (XSS) vulnerability in GE Multilink ML810/3000/3100 series switch 5.2.0 and earlier, and GE Multilink ML800/1200/1600/2400 4.2.1 and earlier."
},
{
"lang": "es",
"value": "Existe una vulnerabilidad de tipo Cross-Site Scripting (XSS) en GE Multilink ML810/3000/3100 series switch 5.2.0 y anteriores y en GE Multilink ML800/1200/1600/2400 4.2.1 y anteriores."
}
],
"id": "CVE-2015-3976",
"lastModified": "2026-05-13T00:24:29.033",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "NONE",
"baseScore": 6.8,
"confidentialityImpact": "NONE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:N/AC:L/Au:S/C:N/I:C/A:N",
"version": "2.0"
},
"exploitabilityScore": 8.0,
"impactScore": 6.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "ics-cert@hq.dhs.gov",
"type": "Secondary",
"userInteractionRequired": true
},
{
"acInsufInfo": false,
"baseSeverity": "LOW",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "NONE",
"baseScore": 3.5,
"confidentialityImpact": "NONE",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
"version": "2.0"
},
"exploitabilityScore": 6.8,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": true
}
],
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
"version": "3.0"
},
"exploitabilityScore": 2.3,
"impactScore": 2.7,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2017-08-28T15:29:01.453",
"references": [
{
"source": "ics-cert@hq.dhs.gov",
"url": "http://www.gedigitalenergy.com/products/support/multilink/MLSB1214.pdf"
},
{
"source": "ics-cert@hq.dhs.gov",
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2015/icsa-15-013-04a.json"
},
{
"source": "ics-cert@hq.dhs.gov",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-15-013-04a"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-013-04A"
}
],
"sourceIdentifier": "ics-cert@hq.dhs.gov",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-79"
}
],
"source": "ics-cert@hq.dhs.gov",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-79"
}
],
"source": "nvd@nist.gov",
"type": "Secondary"
}
]
}
}
}
}
Solutions
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.