Action not permitted
Modal body text goes here.
Modal Title
Modal Body
CVE-2014-8512 (GCVE-0-2014-8512)
Vulnerability from cvelistv5 – Published: 2014-12-27 15:00 – Updated: 2024-08-06 13:18- n/a
| URL | Tags |
|---|---|
| http://download.schneider-electric.com/files?p_Do… | x_refsource_CONFIRM |
| https://ics-cert.us-cert.gov/advisories/ICSA-14-350-01 | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T13:18:48.538Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD%202014-344-01"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-14-350-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2014-12-10T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Buffer overflow in an ActiveX control in Atx45.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8511. NOTE: this may be clarified later based on details provided by researchers."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2014-12-27T14:57:00.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD%202014-344-01"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-14-350-01"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2014-8512",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Buffer overflow in an ActiveX control in Atx45.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8511. NOTE: this may be clarified later based on details provided by researchers."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD%202014-344-01",
"refsource": "CONFIRM",
"url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD%202014-344-01"
},
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-14-350-01",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-14-350-01"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2014-8512",
"datePublished": "2014-12-27T15:00:00.000Z",
"dateReserved": "2014-10-28T00:00:00.000Z",
"dateUpdated": "2024-08-06T13:18:48.538Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2014-8512",
"date": "2026-06-13",
"epss": "0.02556",
"percentile": "0.85887"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2014-8512\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2014-12-27T15:59:01.857\",\"lastModified\":\"2026-05-06T22:30:45.220\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Buffer overflow in an ActiveX control in Atx45.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8511. NOTE: this may be clarified later based on details provided by researchers.\"},{\"lang\":\"es\",\"value\":\"Desbordamiento de buffer en el control de ActiveX en Atx45.ocx en Schneider Electric ProClima anterior a 6.1.7 permite a atacantes remotos ejecutar c\u00f3digo arbitrario a trav\u00e9s de vectores sin especificar, una vulnerabilidad diferente a CVE-2014-8511. NOTA: esto puede se puede clarificar despu\u00e9s en base a los detalles proporcionados por los investigadores.\"}],\"metrics\":{\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:P/A:P\",\"baseScore\":7.5,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":10.0,\"impactScore\":6.4,\"acInsufInfo\":true,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-119\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider_electric:proclima:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"6.0.1\",\"matchCriteriaId\":\"47B0392E-5225-40CD-B1CB-8761B69A743E\"}]}]}],\"references\":[{\"url\":\"http://download.schneider-electric.com/files?p_Doc_Ref=SEVD%202014-344-01\",\"source\":\"cve@mitre.org\",\"tags\":[\"Patch\",\"Vendor Advisory\"]},{\"url\":\"https://ics-cert.us-cert.gov/advisories/ICSA-14-350-01\",\"source\":\"cve@mitre.org\",\"tags\":[\"Patch\",\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"http://download.schneider-electric.com/files?p_Doc_Ref=SEVD%202014-344-01\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\",\"Vendor Advisory\"]},{\"url\":\"https://ics-cert.us-cert.gov/advisories/ICSA-14-350-01\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\",\"Third Party Advisory\",\"US Government Resource\"]}]}}"
}
}
FKIE_CVE-2014-8512
Vulnerability from fkie_nvd - Published: 2014-12-27 15:59 - Updated: 2026-05-06 22:30| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | http://download.schneider-electric.com/files?p_Doc_Ref=SEVD%202014-344-01 | Patch, Vendor Advisory | |
| cve@mitre.org | https://ics-cert.us-cert.gov/advisories/ICSA-14-350-01 | Patch, Third Party Advisory, US Government Resource | |
| af854a3a-2127-422b-91ae-364da2661108 | http://download.schneider-electric.com/files?p_Doc_Ref=SEVD%202014-344-01 | Patch, Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://ics-cert.us-cert.gov/advisories/ICSA-14-350-01 | Patch, Third Party Advisory, US Government Resource |
| Vendor | Product | Version | |
|---|---|---|---|
| schneider_electric | proclima | * |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:schneider_electric:proclima:*:*:*:*:*:*:*:*",
"matchCriteriaId": "47B0392E-5225-40CD-B1CB-8761B69A743E",
"versionEndIncluding": "6.0.1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Buffer overflow in an ActiveX control in Atx45.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8511. NOTE: this may be clarified later based on details provided by researchers."
},
{
"lang": "es",
"value": "Desbordamiento de buffer en el control de ActiveX en Atx45.ocx en Schneider Electric ProClima anterior a 6.1.7 permite a atacantes remotos ejecutar c\u00f3digo arbitrario a trav\u00e9s de vectores sin especificar, una vulnerabilidad diferente a CVE-2014-8511. NOTA: esto puede se puede clarificar despu\u00e9s en base a los detalles proporcionados por los investigadores."
}
],
"id": "CVE-2014-8512",
"lastModified": "2026-05-06T22:30:45.220",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": true,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
]
},
"published": "2014-12-27T15:59:01.857",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD%202014-344-01"
},
{
"source": "cve@mitre.org",
"tags": [
"Patch",
"Third Party Advisory",
"US Government Resource"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-14-350-01"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD%202014-344-01"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Third Party Advisory",
"US Government Resource"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-14-350-01"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-119"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
GHSA-GCQR-PXRF-6RRV
Vulnerability from github – Published: 2022-05-17 04:19 – Updated: 2022-05-17 04:19Buffer overflow in an ActiveX control in Atx45.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8511. NOTE: this may be clarified later based on details provided by researchers.
{
"affected": [],
"aliases": [
"CVE-2014-8512"
],
"database_specific": {
"cwe_ids": [
"CWE-119"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2014-12-27T15:59:00Z",
"severity": "HIGH"
},
"details": "Buffer overflow in an ActiveX control in Atx45.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8511. NOTE: this may be clarified later based on details provided by researchers.",
"id": "GHSA-gcqr-pxrf-6rrv",
"modified": "2022-05-17T04:19:02Z",
"published": "2022-05-17T04:19:02Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2014-8512"
},
{
"type": "WEB",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-14-350-01"
},
{
"type": "WEB",
"url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD%202014-344-01"
}
],
"schema_version": "1.4.0",
"severity": []
}
GSD-2014-8512
Vulnerability from gsd - Updated: 2023-12-13 01:22{
"GSD": {
"alias": "CVE-2014-8512",
"description": "Buffer overflow in an ActiveX control in Atx45.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8511. NOTE: this may be clarified later based on details provided by researchers.",
"id": "GSD-2014-8512"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2014-8512"
],
"details": "Buffer overflow in an ActiveX control in Atx45.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8511. NOTE: this may be clarified later based on details provided by researchers.",
"id": "GSD-2014-8512",
"modified": "2023-12-13T01:22:49.652861Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2014-8512",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Buffer overflow in an ActiveX control in Atx45.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8511. NOTE: this may be clarified later based on details provided by researchers."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD%202014-344-01",
"refsource": "CONFIRM",
"url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD%202014-344-01"
},
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-14-350-01",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-14-350-01"
}
]
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:schneider_electric:proclima:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "6.0.1",
"vulnerable": true
}
],
"operator": "OR"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2014-8512"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "Buffer overflow in an ActiveX control in Atx45.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8511. NOTE: this may be clarified later based on details provided by researchers."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-119"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD%202014-344-01",
"refsource": "CONFIRM",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD%202014-344-01"
},
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-14-350-01",
"refsource": "MISC",
"tags": [
"Patch",
"Third Party Advisory",
"US Government Resource"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-14-350-01"
}
]
}
},
"impact": {
"baseMetricV2": {
"acInsufInfo": true,
"cvssV2": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "HIGH",
"userInteractionRequired": false
}
},
"lastModifiedDate": "2014-12-29T23:11Z",
"publishedDate": "2014-12-27T15:59Z"
}
}
}
ICSA-14-350-01
Vulnerability from csaf_cisa - Published: 2014-09-18 06:00 - Updated: 2025-06-06 22:52{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"lang": "en-US",
"notes": [
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "general",
"text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov",
"title": "CISA Disclaimer"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the risk of exploitation.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Locate control system networks and remote devices behind firewalls and isolating them from business networks.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.",
"title": "Recommended Practices"
}
],
"publisher": {
"category": "coordinator",
"contact_details": "central@cisa.dhs.gov",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "ICS Advisory ICSA-14-350-01 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2014/icsa-14-350-01.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-14-350-01 - Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-14-350-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/topics/industrial-control-systems"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/sites/default/files/publications/emailscams0905.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ncas/tips/ST04-014"
}
],
"title": "Schneider Electric ProClima Command Injection Vulnerabilities",
"tracking": {
"current_release_date": "2025-06-06T22:52:12.653446Z",
"generator": {
"date": "2025-06-06T22:52:12.653388Z",
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-14-350-01",
"initial_release_date": "2014-09-18T06:00:00.000000Z",
"revision_history": [
{
"date": "2014-09-18T06:00:00.000000Z",
"legacy_version": "Initial",
"number": "1",
"summary": "Initial Publication"
},
{
"date": "2025-06-06T22:52:12.653446Z",
"legacy_version": "CSAF Conversion",
"number": "2",
"summary": "Advisory converted into a CSAF"
}
],
"status": "final",
"version": "2"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c=6.0.1",
"product": {
"name": "Schneider Electric ProClima: \u003c=6.0.1",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "ProClima"
}
],
"category": "vendor",
"name": "Schneider Electric"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2014-8513",
"cwe": {
"id": "CWE-77",
"name": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)"
},
"notes": [
{
"category": "summary",
"text": "Buffer overflow in an ActiveX control in MDraw30.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8514 and CVE-2014-9188. NOTE: this may be clarified later based on details provided by researchers.",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Schneider Electric has released an updated version of the ProClima software, Version 6.1.7, which mitigates these vulnerabilities. Customers are encouraged to download the new version and update their installations. It is important that customers first uninstall the current version. The new version can be downloaded from Schneider Electric\u2019s web site at the following location: (http://www.schneider-electric.com/ww/en/download/document/ProClima_software)",
"product_ids": [
"CSAFPID-0001"
],
"url": "http://www.schneider-electric.com/ww/en/download/document/ProClima_software"
},
{
"category": "mitigation",
"details": "For further information on these vulnerabilities, please see Schneider Electric\u2019s security notification (SEVD 2014-344-01) at Schneider Electric\u2019s cybersecurity web page: (http://www2.schneider-electric.com/sites/corporate/en/support/cybersecurity/cyber-security-vulnerabilities-sorted.page)",
"product_ids": [
"CSAFPID-0001"
],
"url": "http://www2.schneider-electric.com/sites/corporate/en/support/cybersecurity/cyber-security-vulnerabilities-sorted.page"
}
],
"scores": [
{
"cvss_v2": {
"baseScore": 10.0,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
"products": [
"CSAFPID-0001"
]
}
]
},
{
"cve": "CVE-2014-8514",
"cwe": {
"id": "CWE-77",
"name": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)"
},
"notes": [
{
"category": "summary",
"text": "Buffer overflow in an ActiveX control in MDraw30.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8513 and CVE-2014-9188. NOTE: this may be clarified later based on details provided by researchers.",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Schneider Electric has released an updated version of the ProClima software, Version 6.1.7, which mitigates these vulnerabilities. Customers are encouraged to download the new version and update their installations. It is important that customers first uninstall the current version. The new version can be downloaded from Schneider Electric\u2019s web site at the following location: (http://www.schneider-electric.com/ww/en/download/document/ProClima_software)",
"product_ids": [
"CSAFPID-0001"
],
"url": "http://www.schneider-electric.com/ww/en/download/document/ProClima_software"
},
{
"category": "mitigation",
"details": "For further information on these vulnerabilities, please see Schneider Electric\u2019s security notification (SEVD 2014-344-01) at Schneider Electric\u2019s cybersecurity web page: (http://www2.schneider-electric.com/sites/corporate/en/support/cybersecurity/cyber-security-vulnerabilities-sorted.page)",
"product_ids": [
"CSAFPID-0001"
],
"url": "http://www2.schneider-electric.com/sites/corporate/en/support/cybersecurity/cyber-security-vulnerabilities-sorted.page"
}
],
"scores": [
{
"cvss_v2": {
"baseScore": 10.0,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
"products": [
"CSAFPID-0001"
]
}
]
},
{
"cve": "CVE-2014-9188",
"cwe": {
"id": "CWE-77",
"name": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)"
},
"notes": [
{
"category": "summary",
"text": "Buffer overflow in an ActiveX control in MDraw30.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8513 and CVE-2014-8514. NOTE: this may be clarified later based on details provided by researchers.",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Schneider Electric has released an updated version of the ProClima software, Version 6.1.7, which mitigates these vulnerabilities. Customers are encouraged to download the new version and update their installations. It is important that customers first uninstall the current version. The new version can be downloaded from Schneider Electric\u2019s web site at the following location: (http://www.schneider-electric.com/ww/en/download/document/ProClima_software)",
"product_ids": [
"CSAFPID-0001"
],
"url": "http://www.schneider-electric.com/ww/en/download/document/ProClima_software"
},
{
"category": "mitigation",
"details": "For further information on these vulnerabilities, please see Schneider Electric\u2019s security notification (SEVD 2014-344-01) at Schneider Electric\u2019s cybersecurity web page: (http://www2.schneider-electric.com/sites/corporate/en/support/cybersecurity/cyber-security-vulnerabilities-sorted.page)",
"product_ids": [
"CSAFPID-0001"
],
"url": "http://www2.schneider-electric.com/sites/corporate/en/support/cybersecurity/cyber-security-vulnerabilities-sorted.page"
}
],
"scores": [
{
"cvss_v2": {
"baseScore": 10.0,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
"products": [
"CSAFPID-0001"
]
}
]
},
{
"cve": "CVE-2014-8511",
"cwe": {
"id": "CWE-77",
"name": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)"
},
"notes": [
{
"category": "summary",
"text": "Buffer overflow in an ActiveX control in Atx45.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8512. NOTE: this may be clarified later based on details provided by researchers.",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Schneider Electric has released an updated version of the ProClima software, Version 6.1.7, which mitigates these vulnerabilities. Customers are encouraged to download the new version and update their installations. It is important that customers first uninstall the current version. The new version can be downloaded from Schneider Electric\u2019s web site at the following location: (http://www.schneider-electric.com/ww/en/download/document/ProClima_software)",
"product_ids": [
"CSAFPID-0001"
],
"url": "http://www.schneider-electric.com/ww/en/download/document/ProClima_software"
},
{
"category": "mitigation",
"details": "For further information on these vulnerabilities, please see Schneider Electric\u2019s security notification (SEVD 2014-344-01) at Schneider Electric\u2019s cybersecurity web page: (http://www2.schneider-electric.com/sites/corporate/en/support/cybersecurity/cyber-security-vulnerabilities-sorted.page)",
"product_ids": [
"CSAFPID-0001"
],
"url": "http://www2.schneider-electric.com/sites/corporate/en/support/cybersecurity/cyber-security-vulnerabilities-sorted.page"
}
],
"scores": [
{
"cvss_v2": {
"baseScore": 10.0,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
"products": [
"CSAFPID-0001"
]
}
]
},
{
"cve": "CVE-2014-8512",
"cwe": {
"id": "CWE-77",
"name": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)"
},
"notes": [
{
"category": "summary",
"text": "Buffer overflow in an ActiveX control in Atx45.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8511. NOTE: this may be clarified later based on details provided by researchers.",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Schneider Electric has released an updated version of the ProClima software, Version 6.1.7, which mitigates these vulnerabilities. Customers are encouraged to download the new version and update their installations. It is important that customers first uninstall the current version. The new version can be downloaded from Schneider Electric\u2019s web site at the following location: (http://www.schneider-electric.com/ww/en/download/document/ProClima_software)",
"product_ids": [
"CSAFPID-0001"
],
"url": "http://www.schneider-electric.com/ww/en/download/document/ProClima_software"
},
{
"category": "mitigation",
"details": "For further information on these vulnerabilities, please see Schneider Electric\u2019s security notification (SEVD 2014-344-01) at Schneider Electric\u2019s cybersecurity web page: (http://www2.schneider-electric.com/sites/corporate/en/support/cybersecurity/cyber-security-vulnerabilities-sorted.page)",
"product_ids": [
"CSAFPID-0001"
],
"url": "http://www2.schneider-electric.com/sites/corporate/en/support/cybersecurity/cyber-security-vulnerabilities-sorted.page"
}
],
"scores": [
{
"cvss_v2": {
"baseScore": 10.0,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
"products": [
"CSAFPID-0001"
]
}
]
}
]
}
VAR-201412-0558
Vulnerability from variot - Updated: 2025-04-12 23:09Buffer overflow in an ActiveX control in Atx45.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8511. NOTE: this may be clarified later based on details provided by researchers. This vulnerability CVE-2014-8511 Is a different vulnerability. The details of this issue may become clear in the future based on information provided by researchers.A third party may execute arbitrary code. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the ATX45.ATX45Ctrl.1 ActiveX control in Atx45.ocx. The control does not check the length of an attacker-supplied string in the SetBodyAttribute method before copying it into a fixed length buffer on the heap. This allows an attacker to execute arbitrary code in the context of the browser process. Schneider Electric provides total solutions for the energy and infrastructure, industrial, data center and network, building and residential markets in more than 100 countries. Failed exploit attempts will likely result in denial-of-service conditions. ProClima 6.0.1 and prior are vulnerable. Schneider Electric ProClima is a set of thermal calculation software from Schneider Electric, France
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201412-0558",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "proclima",
"scope": "lte",
"trust": 1.0,
"vendor": "schneider electric",
"version": "6.0.1"
},
{
"model": "proclima",
"scope": "lt",
"trust": 0.8,
"vendor": "schneider electric",
"version": "6.1.7"
},
{
"model": "proclima",
"scope": null,
"trust": 0.7,
"vendor": "schneider electric",
"version": null
},
{
"model": "electric proclima",
"scope": "lt",
"trust": 0.6,
"vendor": "schneider",
"version": "6.0.1"
},
{
"model": "proclima",
"scope": "eq",
"trust": 0.6,
"vendor": "schneider electric",
"version": "6.0.1"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "proclima",
"version": "*"
}
],
"sources": [
{
"db": "IVD",
"id": "ae2f226c-2351-11e6-abef-000c29c66e3d"
},
{
"db": "ZDI",
"id": "ZDI-15-004"
},
{
"db": "CNVD",
"id": "CNVD-2014-09024"
},
{
"db": "JVNDB",
"id": "JVNDB-2014-007421"
},
{
"db": "CNNVD",
"id": "CNNVD-201412-570"
},
{
"db": "NVD",
"id": "CVE-2014-8512"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"cpe_match": [
{
"cpe22Uri": "cpe:/a:schneider_electric:proclima",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2014-007421"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Brian Gorenc - HP Zero Day Initiative",
"sources": [
{
"db": "ZDI",
"id": "ZDI-15-004"
}
],
"trust": 0.7
},
"cve": "CVE-2014-8512",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "nvd@nist.gov",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "CVE-2014-8512",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "HIGH",
"trust": 2.5,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "CNVD-2014-09024",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "IVD",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "ae2f226c-2351-11e6-abef-000c29c66e3d",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "HIGH",
"trust": 0.2,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.9 [IVD]"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "VHN-76457",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "HIGH",
"trust": 0.1,
"vectorString": "AV:N/AC:L/AU:N/C:P/I:P/A:P",
"version": "2.0"
}
],
"cvssV3": [],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2014-8512",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "NVD",
"id": "CVE-2014-8512",
"trust": 0.8,
"value": "High"
},
{
"author": "ZDI",
"id": "CVE-2014-8512",
"trust": 0.7,
"value": "HIGH"
},
{
"author": "CNVD",
"id": "CNVD-2014-09024",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-201412-570",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "IVD",
"id": "ae2f226c-2351-11e6-abef-000c29c66e3d",
"trust": 0.2,
"value": "HIGH"
},
{
"author": "VULHUB",
"id": "VHN-76457",
"trust": 0.1,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "IVD",
"id": "ae2f226c-2351-11e6-abef-000c29c66e3d"
},
{
"db": "ZDI",
"id": "ZDI-15-004"
},
{
"db": "CNVD",
"id": "CNVD-2014-09024"
},
{
"db": "VULHUB",
"id": "VHN-76457"
},
{
"db": "JVNDB",
"id": "JVNDB-2014-007421"
},
{
"db": "CNNVD",
"id": "CNNVD-201412-570"
},
{
"db": "NVD",
"id": "CVE-2014-8512"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Buffer overflow in an ActiveX control in Atx45.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8511. NOTE: this may be clarified later based on details provided by researchers. This vulnerability CVE-2014-8511 Is a different vulnerability. The details of this issue may become clear in the future based on information provided by researchers.A third party may execute arbitrary code. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the ATX45.ATX45Ctrl.1 ActiveX control in Atx45.ocx. The control does not check the length of an attacker-supplied string in the SetBodyAttribute method before copying it into a fixed length buffer on the heap. This allows an attacker to execute arbitrary code in the context of the browser process. Schneider Electric provides total solutions for the energy and infrastructure, industrial, data center and network, building and residential markets in more than 100 countries. Failed exploit attempts will likely result in denial-of-service conditions. \nProClima 6.0.1 and prior are vulnerable. Schneider Electric ProClima is a set of thermal calculation software from Schneider Electric, France",
"sources": [
{
"db": "NVD",
"id": "CVE-2014-8512"
},
{
"db": "JVNDB",
"id": "JVNDB-2014-007421"
},
{
"db": "ZDI",
"id": "ZDI-15-004"
},
{
"db": "CNVD",
"id": "CNVD-2014-09024"
},
{
"db": "BID",
"id": "71711"
},
{
"db": "IVD",
"id": "ae2f226c-2351-11e6-abef-000c29c66e3d"
},
{
"db": "VULHUB",
"id": "VHN-76457"
}
],
"trust": 3.33
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2014-8512",
"trust": 4.3
},
{
"db": "ICS CERT",
"id": "ICSA-14-350-01",
"trust": 2.5
},
{
"db": "BID",
"id": "71711",
"trust": 1.0
},
{
"db": "CNNVD",
"id": "CNNVD-201412-570",
"trust": 0.9
},
{
"db": "CNVD",
"id": "CNVD-2014-09024",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2014-007421",
"trust": 0.8
},
{
"db": "ZDI_CAN",
"id": "ZDI-CAN-2479",
"trust": 0.7
},
{
"db": "ZDI",
"id": "ZDI-15-004",
"trust": 0.7
},
{
"db": "IVD",
"id": "AE2F226C-2351-11E6-ABEF-000C29C66E3D",
"trust": 0.2
},
{
"db": "VULHUB",
"id": "VHN-76457",
"trust": 0.1
}
],
"sources": [
{
"db": "IVD",
"id": "ae2f226c-2351-11e6-abef-000c29c66e3d"
},
{
"db": "ZDI",
"id": "ZDI-15-004"
},
{
"db": "CNVD",
"id": "CNVD-2014-09024"
},
{
"db": "VULHUB",
"id": "VHN-76457"
},
{
"db": "BID",
"id": "71711"
},
{
"db": "JVNDB",
"id": "JVNDB-2014-007421"
},
{
"db": "CNNVD",
"id": "CNNVD-201412-570"
},
{
"db": "NVD",
"id": "CVE-2014-8512"
}
]
},
"id": "VAR-201412-0558",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "IVD",
"id": "ae2f226c-2351-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2014-09024"
},
{
"db": "VULHUB",
"id": "VHN-76457"
}
],
"trust": 1.9
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.8
}
],
"sources": [
{
"db": "IVD",
"id": "ae2f226c-2351-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2014-09024"
}
]
},
"last_update_date": "2025-04-12T23:09:13.985000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "ProClima Software Vulnerability Disclosure",
"trust": 0.8,
"url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD%202014-344-01"
},
{
"title": "Schneider Electric has issued an update to correct this vulnerability.",
"trust": 0.7,
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-14-350-01"
},
{
"title": "Patch for Schneider Electric ProClima Remote Buffer Overflow Vulnerability (CNVD-2014-09024)",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/52959"
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-15-004"
},
{
"db": "CNVD",
"id": "CNVD-2014-09024"
},
{
"db": "JVNDB",
"id": "JVNDB-2014-007421"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-119",
"trust": 1.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-76457"
},
{
"db": "JVNDB",
"id": "JVNDB-2014-007421"
},
{
"db": "NVD",
"id": "CVE-2014-8512"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 3.2,
"url": "https://ics-cert.us-cert.gov/advisories/icsa-14-350-01"
},
{
"trust": 1.7,
"url": "http://download.schneider-electric.com/files?p_doc_ref=sevd%202014-344-01"
},
{
"trust": 0.8,
"url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2014-8512"
},
{
"trust": 0.8,
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2014-8512"
},
{
"trust": 0.6,
"url": "http://www.securityfocus.com/bid/71711"
},
{
"trust": 0.3,
"url": "http://www.schneider-electric.com/site/home/index.cfm/ww/?selectcountry=true"
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-15-004"
},
{
"db": "CNVD",
"id": "CNVD-2014-09024"
},
{
"db": "VULHUB",
"id": "VHN-76457"
},
{
"db": "BID",
"id": "71711"
},
{
"db": "JVNDB",
"id": "JVNDB-2014-007421"
},
{
"db": "CNNVD",
"id": "CNNVD-201412-570"
},
{
"db": "NVD",
"id": "CVE-2014-8512"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "IVD",
"id": "ae2f226c-2351-11e6-abef-000c29c66e3d"
},
{
"db": "ZDI",
"id": "ZDI-15-004"
},
{
"db": "CNVD",
"id": "CNVD-2014-09024"
},
{
"db": "VULHUB",
"id": "VHN-76457"
},
{
"db": "BID",
"id": "71711"
},
{
"db": "JVNDB",
"id": "JVNDB-2014-007421"
},
{
"db": "CNNVD",
"id": "CNNVD-201412-570"
},
{
"db": "NVD",
"id": "CVE-2014-8512"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2014-12-19T00:00:00",
"db": "IVD",
"id": "ae2f226c-2351-11e6-abef-000c29c66e3d"
},
{
"date": "2015-01-07T00:00:00",
"db": "ZDI",
"id": "ZDI-15-004"
},
{
"date": "2014-12-19T00:00:00",
"db": "CNVD",
"id": "CNVD-2014-09024"
},
{
"date": "2014-12-27T00:00:00",
"db": "VULHUB",
"id": "VHN-76457"
},
{
"date": "2014-12-10T00:00:00",
"db": "BID",
"id": "71711"
},
{
"date": "2015-01-06T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2014-007421"
},
{
"date": "2014-12-27T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201412-570"
},
{
"date": "2014-12-27T15:59:01.857000",
"db": "NVD",
"id": "CVE-2014-8512"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2015-01-07T00:00:00",
"db": "ZDI",
"id": "ZDI-15-004"
},
{
"date": "2014-12-19T00:00:00",
"db": "CNVD",
"id": "CNVD-2014-09024"
},
{
"date": "2014-12-29T00:00:00",
"db": "VULHUB",
"id": "VHN-76457"
},
{
"date": "2015-01-12T00:02:00",
"db": "BID",
"id": "71711"
},
{
"date": "2015-01-06T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2014-007421"
},
{
"date": "2015-01-04T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201412-570"
},
{
"date": "2025-04-12T10:46:40.837000",
"db": "NVD",
"id": "CVE-2014-8512"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201412-570"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Schneider Electric ProClima of Atx45.ocx of ActiveX Control buffer overflow vulnerability",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2014-007421"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Buffer overflow",
"sources": [
{
"db": "IVD",
"id": "ae2f226c-2351-11e6-abef-000c29c66e3d"
},
{
"db": "CNNVD",
"id": "CNNVD-201412-570"
}
],
"trust": 0.8
}
}
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.