CVE-2012-3030 (GCVE-0-2012-3030)
Vulnerability from cvelistv5 – Published: 2012-09-18 14:00 – Updated: 2024-09-16 20:27- n/a
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T19:50:05.389Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-864051.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://en.securitylab.ru/lab/PT-2012-43"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-256-01.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, stores sensitive information under the web root with insufficient access control, which allows remote attackers to read a (1) log file or (2) configuration file via a direct request."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2012-09-18T14:00:00.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-864051.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://en.securitylab.ru/lab/PT-2012-43"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-256-01.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2012-3030",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, stores sensitive information under the web root with insufficient access control, which allows remote attackers to read a (1) log file or (2) configuration file via a direct request."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-864051.pdf",
"refsource": "CONFIRM",
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-864051.pdf"
},
{
"name": "http://en.securitylab.ru/lab/PT-2012-43",
"refsource": "MISC",
"url": "http://en.securitylab.ru/lab/PT-2012-43"
},
{
"name": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-256-01.pdf",
"refsource": "MISC",
"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-256-01.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2012-3030",
"datePublished": "2012-09-18T14:00:00.000Z",
"dateReserved": "2012-05-30T00:00:00.000Z",
"dateUpdated": "2024-09-16T20:27:37.541Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2012-3030",
"date": "2026-04-17",
"epss": "0.00518",
"percentile": "0.66764"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2012-3030\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2012-09-18T14:55:01.443\",\"lastModified\":\"2025-04-11T00:51:21.963\",\"vulnStatus\":\"Deferred\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, stores sensitive information under the web root with insufficient access control, which allows remote attackers to read a (1) log file or (2) configuration file via a direct request.\"},{\"lang\":\"es\",\"value\":\"WebNavigator en Siemens WinCC v7.0 SP3 y anteriores, como las usadas en SIMATIC PCS7 y otros productos, almacena informaci\u00f3n sensible bajo l directorio web raiz con un control de acceso no suficiente, lo que permite a atacantes remotos a leer (1) ficheros de registro o (2) ficheros de configuraci\u00f3n a trav\u00e9s de una petici\u00f3n directa.\"}],\"metrics\":{\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:N/A:N\",\"baseScore\":5.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":10.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-264\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_pcs7:8.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E8B894F4-9635-4436-BC0A-E43280426017\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:wincc:*:sp3:*:*:*:*:*:*\",\"versionEndIncluding\":\"7.0\",\"matchCriteriaId\":\"5AC094B0-B1BE-436D-A8D3-2008D0CDE070\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:wincc:5.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B4CB277F-7ECB-4F44-8BB5-A3D350486EE7\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:wincc:5.0:sp1:*:*:*:*:*:*\",\"matchCriteriaId\":\"616535F1-F609-408B-AE48-61ACF48748A1\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:wincc:6.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7F322FCB-32F4-4C5A-A7F5-F7EF41188C88\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:wincc:6.0:sp2:*:*:*:*:*:*\",\"matchCriteriaId\":\"69822DB4-DC79-4F88-A470-5AC512C77377\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:wincc:6.0:sp3:*:*:*:*:*:*\",\"matchCriteriaId\":\"996DE8BD-DD51-41EF-9882-C2BD2CC5FE53\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:wincc:6.0:sp4:*:*:*:*:*:*\",\"matchCriteriaId\":\"945C8B46-4CDA-4143-889C-30E30E93DB29\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:wincc:7.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A33F9015-7058-419A-8762-CB2AE4ACF1A7\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:wincc:7.0:sp1:*:*:*:*:*:*\",\"matchCriteriaId\":\"E6271FCC-CCF6-4D31-801A-B4B0DC4639DD\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:wincc:7.0:sp2:*:*:*:*:*:*\",\"matchCriteriaId\":\"DF7A6B2B-D573-4285-B3B4-136F2BE7E710\"}]}]}],\"references\":[{\"url\":\"http://en.securitylab.ru/lab/PT-2012-43\",\"source\":\"ics-cert@hq.dhs.gov\"},{\"url\":\"http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-864051.pdf\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Patch\",\"Vendor Advisory\"]},{\"url\":\"http://www.us-cert.gov/control_systems/pdf/ICSA-12-256-01.pdf\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"US Government Resource\"]},{\"url\":\"http://en.securitylab.ru/lab/PT-2012-43\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-864051.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\",\"Vendor Advisory\"]},{\"url\":\"http://www.us-cert.gov/control_systems/pdf/ICSA-12-256-01.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"US Government Resource\"]}]}}"
}
}
GHSA-PF86-R434-Q384
Vulnerability from github – Published: 2022-05-17 05:17 – Updated: 2022-05-17 05:17WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, stores sensitive information under the web root with insufficient access control, which allows remote attackers to read a (1) log file or (2) configuration file via a direct request.
{
"affected": [],
"aliases": [
"CVE-2012-3030"
],
"database_specific": {
"cwe_ids": [],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2012-09-18T14:55:00Z",
"severity": "MODERATE"
},
"details": "WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, stores sensitive information under the web root with insufficient access control, which allows remote attackers to read a (1) log file or (2) configuration file via a direct request.",
"id": "GHSA-pf86-r434-q384",
"modified": "2022-05-17T05:17:49Z",
"published": "2022-05-17T05:17:49Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2012-3030"
},
{
"type": "WEB",
"url": "http://en.securitylab.ru/lab/PT-2012-43"
},
{
"type": "WEB",
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-864051.pdf"
},
{
"type": "WEB",
"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-256-01.pdf"
}
],
"schema_version": "1.4.0",
"severity": []
}
VAR-201209-0223
Vulnerability from variot - Updated: 2025-04-11 23:01WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, stores sensitive information under the web root with insufficient access control, which allows remote attackers to read a (1) log file or (2) configuration file via a direct request. Siemens SIMATIC is an automation software in a single engineering environment. The Siemens SIMATIC WinCC WebNavigator component incorrectly handles input, allowing an attacker to read system files using a directory traversal sequence. Siemens SIMATIC WinCC is prone to information-disclosure, SQL-injection, directory-traversal, and cross-site scripting vulnerabilities because it fails to sufficiently sanitize user-supplied input. The attacker may exploit the information-disclosure issue and directory-traversal issues to gain access to sensitive information that may lead to further attacks. The attacker may exploit the SQL-injection issue to compromise the application, access or modify data, or exploit latent vulnerabilities in the underlying database. An attacker may leverage the cross-site scripting issue to execute arbitrary script code in the browser of an unsuspecting user in the context of the affected site. This may allow the attacker to steal cookie-based authentication credentials and to launch other attacks. Siemens SIMATIC WinCC 7.0 SP3 and prior versions are vulnerable. WinCC flexible is a human-machine interface used in some machine or process applications.
The application allows users to perform certain actions via HTTP requests without performing proper validity checks to verify the requests. This can be exploited to perform certain unspecified actions when a logged-in administrative user visits a specially crafted web page. ----------------------------------------------------------------------
The final version of the CSI 6.0 has been released. Find out why this is not just another Patch Management solution: http://secunia.com/blog/325/
TITLE: Siemens SIMATIC WinCC Multiple Vulnerabilities
SECUNIA ADVISORY ID: SA50568
VERIFY ADVISORY: Secunia.com http://secunia.com/advisories/50568/ Customer Area (Credentials Required) https://ca.secunia.com/?page=viewadvisory&vuln_id=50568
RELEASE DATE: 2012-09-11
DISCUSS ADVISORY: http://secunia.com/advisories/50568/#comments
AVAILABLE ON SITE AND IN CUSTOMER AREA: * Last Update * Popularity * Comments * Criticality Level * Impact * Where * Solution Status * Operating System / Software * CVE Reference(s)
http://secunia.com/advisories/50568/
ONLY AVAILABLE IN CUSTOMER AREA: * Authentication Level * Report Reliability * Secunia PoC * Secunia Analysis * Systems Affected * Approve Distribution * Remediation Status * Secunia CVSS Score * CVSS
https://ca.secunia.com/?page=viewadvisory&vuln_id=50568
ONLY AVAILABLE WITH SECUNIA CSI AND SECUNIA PSI: * AUTOMATED SCANNING
http://secunia.com/vulnerability_scanning/personal/ http://secunia.com/vulnerability_scanning/corporate/wsus_sccm_3rd_third_party_patching/
DESCRIPTION: Multiple vulnerabilities have been reported in Siemens SIMATIC WinCC, which can be exploited by malicious people to conduct cross-site scripting attacks, conduct SQL injection attacks, and disclose certain sensitive information.
1) Certain unspecified input passed to the WebNavigator component is not properly sanitised before being returned to the user.
3) Certain input passed via SOAP messages to the WebNavigator component is not properly sanitised before being used in SQL queries. This can be exploited to manipulate SQL queries by injecting arbitrary SQL code.
4) An error within the ActiveX control can be exploited to disclose the username and password of an authenticated user.
SOLUTION: Apply Update 3.
Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
PROVIDED AND/OR DISCOVERED BY: The vendor credits Denis Baranov, Sergey Bobrov, Artem Chaykin, Vladimir Kochetkov, Pavel Toporkov, and Timur Yunusov, Positive Technologies.
ORIGINAL ADVISORY: http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-864051.pdf
OTHER REFERENCES: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
DEEP LINKS: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
EXTENDED DESCRIPTION: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
EXTENDED SOLUTION: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
EXPLOIT: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
About: This Advisory was delivered by Secunia as a free service to help private users keeping their systems up to date against the latest vulnerabilities.
Subscribe: http://secunia.com/advisories/secunia_security_advisories/
Definitions: (Criticality, Where etc.) http://secunia.com/advisories/about_secunia_advisories/
Please Note: Secunia recommends that you verify all advisories you receive by clicking the link. Secunia NEVER sends attached files with advisories. Secunia does not advise people to install third party patches, only use those supplied by the vendor.
Unsubscribe: Secunia Security Advisories http://secunia.com/sec_adv_unsubscribe/?email=packet%40packetstormsecurity.org
Show details on source website
{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201209-0223",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "simatic pcs7",
"scope": "eq",
"trust": 1.6,
"vendor": "siemens",
"version": "8.0"
},
{
"model": "wincc",
"scope": "eq",
"trust": 1.6,
"vendor": "siemens",
"version": "6.0"
},
{
"model": "wincc",
"scope": "eq",
"trust": 1.6,
"vendor": "siemens",
"version": "5.0"
},
{
"model": "wincc",
"scope": "eq",
"trust": 1.6,
"vendor": "siemens",
"version": "7.0"
},
{
"model": "wincc",
"scope": "lte",
"trust": 1.0,
"vendor": "siemens",
"version": "7.0"
},
{
"model": null,
"scope": "eq",
"trust": 0.8,
"vendor": "wincc",
"version": "6.0"
},
{
"model": "simatic pcs 7",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "simatic wincc",
"scope": "lte",
"trust": 0.8,
"vendor": "siemens",
"version": "7.0 sp3"
},
{
"model": null,
"scope": "eq",
"trust": 0.6,
"vendor": "wincc",
"version": "7.0"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "7.x"
},
{
"model": "simatic pcs",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "77.x"
},
{
"model": null,
"scope": "eq",
"trust": 0.4,
"vendor": "wincc",
"version": "5.0"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic pcs7",
"version": "8.0"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "wincc",
"version": "*"
}
],
"sources": [
{
"db": "IVD",
"id": "5dd6af86-2353-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2012-5083"
},
{
"db": "JVNDB",
"id": "JVNDB-2012-004447"
},
{
"db": "CNNVD",
"id": "CNNVD-201209-293"
},
{
"db": "NVD",
"id": "CVE-2012-3030"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"cpe_match": [
{
"cpe22Uri": "cpe:/a:siemens:simatic_pcs_7",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/a:siemens:simatic_wincc_%28tia_portal%29",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2012-004447"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Denis Baranov Sergey Bobrov, Artem Chaykin, Vladimir Kochetkov, Pavel Toporkov,Timur Yunusov from Positive Technologies",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201209-293"
}
],
"trust": 0.6
},
"cve": "CVE-2012-3030",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "nvd@nist.gov",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "CVE-2012-3030",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 1.8,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "IVD",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "5dd6af86-2353-11e6-abef-000c29c66e3d",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.2,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.9 [IVD]"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "VHN-56311",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.1,
"vectorString": "AV:N/AC:L/AU:N/C:P/I:N/A:N",
"version": "2.0"
}
],
"cvssV3": [],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2012-3030",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "NVD",
"id": "CVE-2012-3030",
"trust": 0.8,
"value": "Medium"
},
{
"author": "CNNVD",
"id": "CNNVD-201209-293",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "IVD",
"id": "5dd6af86-2353-11e6-abef-000c29c66e3d",
"trust": 0.2,
"value": "MEDIUM"
},
{
"author": "VULHUB",
"id": "VHN-56311",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "IVD",
"id": "5dd6af86-2353-11e6-abef-000c29c66e3d"
},
{
"db": "VULHUB",
"id": "VHN-56311"
},
{
"db": "JVNDB",
"id": "JVNDB-2012-004447"
},
{
"db": "CNNVD",
"id": "CNNVD-201209-293"
},
{
"db": "NVD",
"id": "CVE-2012-3030"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, stores sensitive information under the web root with insufficient access control, which allows remote attackers to read a (1) log file or (2) configuration file via a direct request. Siemens SIMATIC is an automation software in a single engineering environment. The Siemens SIMATIC WinCC WebNavigator component incorrectly handles input, allowing an attacker to read system files using a directory traversal sequence. Siemens SIMATIC WinCC is prone to information-disclosure, SQL-injection, directory-traversal, and cross-site scripting vulnerabilities because it fails to sufficiently sanitize user-supplied input. \nThe attacker may exploit the information-disclosure issue and directory-traversal issues to gain access to sensitive information that may lead to further attacks. \nThe attacker may exploit the SQL-injection issue to compromise the application, access or modify data, or exploit latent vulnerabilities in the underlying database. \nAn attacker may leverage the cross-site scripting issue to execute arbitrary script code in the browser of an unsuspecting user in the context of the affected site. This may allow the attacker to steal cookie-based authentication credentials and to launch other attacks. \nSiemens SIMATIC WinCC 7.0 SP3 and prior versions are vulnerable. WinCC flexible is a human-machine interface used in some machine or process applications. \n\nThe application allows users to perform certain actions via HTTP\nrequests without performing proper validity checks to verify the\nrequests. This can be exploited to perform certain unspecified\nactions when a logged-in administrative user visits a specially\ncrafted web page. ----------------------------------------------------------------------\n\nThe final version of the CSI 6.0 has been released. \nFind out why this is not just another Patch Management solution: http://secunia.com/blog/325/\n\n----------------------------------------------------------------------\n\nTITLE:\nSiemens SIMATIC WinCC Multiple Vulnerabilities\n\nSECUNIA ADVISORY ID:\nSA50568\n\nVERIFY ADVISORY:\nSecunia.com\nhttp://secunia.com/advisories/50568/\nCustomer Area (Credentials Required)\nhttps://ca.secunia.com/?page=viewadvisory\u0026vuln_id=50568\n\nRELEASE DATE:\n2012-09-11\n\nDISCUSS ADVISORY:\nhttp://secunia.com/advisories/50568/#comments\n\nAVAILABLE ON SITE AND IN CUSTOMER AREA:\n * Last Update\n * Popularity\n * Comments\n * Criticality Level\n * Impact\n * Where\n * Solution Status\n * Operating System / Software\n * CVE Reference(s)\n\nhttp://secunia.com/advisories/50568/\n\nONLY AVAILABLE IN CUSTOMER AREA:\n * Authentication Level\n * Report Reliability\n * Secunia PoC\n * Secunia Analysis\n * Systems Affected\n * Approve Distribution\n * Remediation Status\n * Secunia CVSS Score\n * CVSS\n\nhttps://ca.secunia.com/?page=viewadvisory\u0026vuln_id=50568\n\nONLY AVAILABLE WITH SECUNIA CSI AND SECUNIA PSI:\n * AUTOMATED SCANNING\n\nhttp://secunia.com/vulnerability_scanning/personal/\nhttp://secunia.com/vulnerability_scanning/corporate/wsus_sccm_3rd_third_party_patching/\n\nDESCRIPTION:\nMultiple vulnerabilities have been reported in Siemens SIMATIC WinCC,\nwhich can be exploited by malicious people to conduct cross-site\nscripting attacks, conduct SQL injection attacks, and disclose\ncertain sensitive information. \n\n1) Certain unspecified input passed to the WebNavigator component is\nnot properly sanitised before being returned to the user. \n\n3) Certain input passed via SOAP messages to the WebNavigator\ncomponent is not properly sanitised before being used in SQL queries. \nThis can be exploited to manipulate SQL queries by injecting arbitrary\nSQL code. \n\n4) An error within the ActiveX control can be exploited to disclose\nthe username and password of an authenticated user. \n\nSOLUTION:\nApply Update 3. \n\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\nPROVIDED AND/OR DISCOVERED BY:\nThe vendor credits Denis Baranov, Sergey Bobrov, Artem Chaykin,\nVladimir Kochetkov, Pavel Toporkov, and Timur Yunusov, Positive\nTechnologies. \n\nORIGINAL ADVISORY:\nhttp://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-864051.pdf\n\nOTHER REFERENCES:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\nDEEP LINKS:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\nEXTENDED DESCRIPTION:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\nEXTENDED SOLUTION:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\nEXPLOIT:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\n----------------------------------------------------------------------\n\nAbout:\nThis Advisory was delivered by Secunia as a free service to help\nprivate users keeping their systems up to date against the latest\nvulnerabilities. \n\nSubscribe:\nhttp://secunia.com/advisories/secunia_security_advisories/\n\nDefinitions: (Criticality, Where etc.)\nhttp://secunia.com/advisories/about_secunia_advisories/\n\n\nPlease Note:\nSecunia recommends that you verify all advisories you receive by\nclicking the link. \nSecunia NEVER sends attached files with advisories. \nSecunia does not advise people to install third party patches, only\nuse those supplied by the vendor. \n\n----------------------------------------------------------------------\n\nUnsubscribe: Secunia Security Advisories\nhttp://secunia.com/sec_adv_unsubscribe/?email=packet%40packetstormsecurity.org\n\n----------------------------------------------------------------------\n\n\n",
"sources": [
{
"db": "NVD",
"id": "CVE-2012-3030"
},
{
"db": "JVNDB",
"id": "JVNDB-2012-004447"
},
{
"db": "CNVD",
"id": "CNVD-2012-5083"
},
{
"db": "BID",
"id": "55492"
},
{
"db": "IVD",
"id": "5dd6af86-2353-11e6-abef-000c29c66e3d"
},
{
"db": "VULHUB",
"id": "VHN-56311"
},
{
"db": "PACKETSTORM",
"id": "116445"
},
{
"db": "PACKETSTORM",
"id": "116447"
}
],
"trust": 2.88
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2012-3030",
"trust": 3.6
},
{
"db": "SIEMENS",
"id": "SSA-864051",
"trust": 2.5
},
{
"db": "ICS CERT",
"id": "ICSA-12-256-01",
"trust": 2.5
},
{
"db": "CNNVD",
"id": "CNNVD-201209-293",
"trust": 0.9
},
{
"db": "BID",
"id": "55492",
"trust": 0.9
},
{
"db": "CNVD",
"id": "CNVD-2012-5083",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2012-004447",
"trust": 0.8
},
{
"db": "SECUNIA",
"id": "50568",
"trust": 0.8
},
{
"db": "NSFOCUS",
"id": "20651",
"trust": 0.6
},
{
"db": "NSFOCUS",
"id": "20932",
"trust": 0.6
},
{
"db": "IVD",
"id": "5DD6AF86-2353-11E6-ABEF-000C29C66E3D",
"trust": 0.2
},
{
"db": "SECUNIA",
"id": "50581",
"trust": 0.2
},
{
"db": "VULHUB",
"id": "VHN-56311",
"trust": 0.1
},
{
"db": "PACKETSTORM",
"id": "116445",
"trust": 0.1
},
{
"db": "PACKETSTORM",
"id": "116447",
"trust": 0.1
}
],
"sources": [
{
"db": "IVD",
"id": "5dd6af86-2353-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2012-5083"
},
{
"db": "VULHUB",
"id": "VHN-56311"
},
{
"db": "BID",
"id": "55492"
},
{
"db": "JVNDB",
"id": "JVNDB-2012-004447"
},
{
"db": "PACKETSTORM",
"id": "116445"
},
{
"db": "PACKETSTORM",
"id": "116447"
},
{
"db": "CNNVD",
"id": "CNNVD-201209-293"
},
{
"db": "NVD",
"id": "CVE-2012-3030"
}
]
},
"id": "VAR-201209-0223",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "IVD",
"id": "5dd6af86-2353-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2012-5083"
},
{
"db": "VULHUB",
"id": "VHN-56311"
}
],
"trust": 1.5048571666666666
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.8
}
],
"sources": [
{
"db": "IVD",
"id": "5dd6af86-2353-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2012-5083"
}
]
},
"last_update_date": "2025-04-11T23:01:54.244000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Top Page",
"trust": 0.8,
"url": "http://www.siemens.com/"
},
{
"title": "SSA-864051: Multiple Vulnerabilities in WinCC 7.0 SP3",
"trust": 0.8,
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-864051.pdf"
},
{
"title": "\u30b7\u30fc\u30e1\u30f3\u30b9\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u30d1\u30fc\u30c8\u30ca\u30fc",
"trust": 0.8,
"url": "http://www.automation.siemens.com/automation/jp/ja/solutionpartner/pages/default.aspx"
},
{
"title": "\u30b7\u30fc\u30e1\u30f3\u30b9\u30fb\u30b8\u30e3\u30d1\u30f3\u682a\u5f0f\u4f1a\u793e",
"trust": 0.8,
"url": "http://www.siemens.com/entry/jp/ja/"
},
{
"title": "Patch for Siemens SIMATIC WinCC arbitrary file read vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/22131"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2012-5083"
},
{
"db": "JVNDB",
"id": "JVNDB-2012-004447"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-264",
"trust": 1.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-56311"
},
{
"db": "JVNDB",
"id": "JVNDB-2012-004447"
},
{
"db": "NVD",
"id": "CVE-2012-3030"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.5,
"url": "http://www.us-cert.gov/control_systems/pdf/icsa-12-256-01.pdf"
},
{
"trust": 1.9,
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-864051.pdf"
},
{
"trust": 1.7,
"url": "http://en.securitylab.ru/lab/pt-2012-43"
},
{
"trust": 0.8,
"url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2012-3030"
},
{
"trust": 0.8,
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2012-3030"
},
{
"trust": 0.6,
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-864051.pdfhttp"
},
{
"trust": 0.6,
"url": "http://secunia.com/advisories/50568"
},
{
"trust": 0.6,
"url": "http://www.securityfocus.com/bid/55492"
},
{
"trust": 0.6,
"url": "http://www.nsfocus.net/vulndb/20932"
},
{
"trust": 0.6,
"url": "http://www.nsfocus.net/vulndb/20651"
},
{
"trust": 0.3,
"url": "http://aunz.siemens.com/newscentre/productreleases/pages/iac_pr_simaticwinccv62.aspx"
},
{
"trust": 0.2,
"url": "http://secunia.com/vulnerability_intelligence/"
},
{
"trust": 0.2,
"url": "http://secunia.com/advisories/secunia_security_advisories/"
},
{
"trust": 0.2,
"url": "http://secunia.com/vulnerability_scanning/corporate/wsus_sccm_3rd_third_party_patching/"
},
{
"trust": 0.2,
"url": "http://secunia.com/vulnerability_scanning/personal/"
},
{
"trust": 0.2,
"url": "http://secunia.com/sec_adv_unsubscribe/?email=packet%40packetstormsecurity.org"
},
{
"trust": 0.2,
"url": "http://secunia.com/blog/325/"
},
{
"trust": 0.2,
"url": "http://secunia.com/advisories/about_secunia_advisories/"
},
{
"trust": 0.1,
"url": "https://ca.secunia.com/?page=viewadvisory\u0026vuln_id=50581"
},
{
"trust": 0.1,
"url": "http://secunia.com/advisories/50581/#comments"
},
{
"trust": 0.1,
"url": "http://secunia.com/advisories/50581/"
},
{
"trust": 0.1,
"url": "http://secunia.com/advisories/50568/"
},
{
"trust": 0.1,
"url": "http://secunia.com/advisories/50568/#comments"
},
{
"trust": 0.1,
"url": "https://ca.secunia.com/?page=viewadvisory\u0026vuln_id=50568"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2012-5083"
},
{
"db": "VULHUB",
"id": "VHN-56311"
},
{
"db": "BID",
"id": "55492"
},
{
"db": "JVNDB",
"id": "JVNDB-2012-004447"
},
{
"db": "PACKETSTORM",
"id": "116445"
},
{
"db": "PACKETSTORM",
"id": "116447"
},
{
"db": "CNNVD",
"id": "CNNVD-201209-293"
},
{
"db": "NVD",
"id": "CVE-2012-3030"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "IVD",
"id": "5dd6af86-2353-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2012-5083"
},
{
"db": "VULHUB",
"id": "VHN-56311"
},
{
"db": "BID",
"id": "55492"
},
{
"db": "JVNDB",
"id": "JVNDB-2012-004447"
},
{
"db": "PACKETSTORM",
"id": "116445"
},
{
"db": "PACKETSTORM",
"id": "116447"
},
{
"db": "CNNVD",
"id": "CNNVD-201209-293"
},
{
"db": "NVD",
"id": "CVE-2012-3030"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2012-09-13T00:00:00",
"db": "IVD",
"id": "5dd6af86-2353-11e6-abef-000c29c66e3d"
},
{
"date": "2012-09-13T00:00:00",
"db": "CNVD",
"id": "CNVD-2012-5083"
},
{
"date": "2012-09-18T00:00:00",
"db": "VULHUB",
"id": "VHN-56311"
},
{
"date": "2012-09-11T00:00:00",
"db": "BID",
"id": "55492"
},
{
"date": "2012-09-20T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2012-004447"
},
{
"date": "2012-09-11T07:30:00",
"db": "PACKETSTORM",
"id": "116445"
},
{
"date": "2012-09-11T07:30:06",
"db": "PACKETSTORM",
"id": "116447"
},
{
"date": "2012-09-18T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201209-293"
},
{
"date": "2012-09-18T14:55:01.443000",
"db": "NVD",
"id": "CVE-2012-3030"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2012-09-13T00:00:00",
"db": "CNVD",
"id": "CNVD-2012-5083"
},
{
"date": "2012-12-20T00:00:00",
"db": "VULHUB",
"id": "VHN-56311"
},
{
"date": "2012-09-12T22:50:00",
"db": "BID",
"id": "55492"
},
{
"date": "2012-09-20T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2012-004447"
},
{
"date": "2012-09-20T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201209-293"
},
{
"date": "2025-04-11T00:51:21.963000",
"db": "NVD",
"id": "CVE-2012-3030"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201209-293"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Siemens SIMATIC WinCC Arbitrary File Read Vulnerability",
"sources": [
{
"db": "IVD",
"id": "5dd6af86-2353-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2012-5083"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "permissions and access control",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201209-293"
}
],
"trust": 0.6
}
}
FKIE_CVE-2012-3030
Vulnerability from fkie_nvd - Published: 2012-09-18 14:55 - Updated: 2025-04-11 00:51{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:simatic_pcs7:8.0:*:*:*:*:*:*:*",
"matchCriteriaId": "E8B894F4-9635-4436-BC0A-E43280426017",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:wincc:*:sp3:*:*:*:*:*:*",
"matchCriteriaId": "5AC094B0-B1BE-436D-A8D3-2008D0CDE070",
"versionEndIncluding": "7.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:wincc:5.0:*:*:*:*:*:*:*",
"matchCriteriaId": "B4CB277F-7ECB-4F44-8BB5-A3D350486EE7",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:wincc:5.0:sp1:*:*:*:*:*:*",
"matchCriteriaId": "616535F1-F609-408B-AE48-61ACF48748A1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:wincc:6.0:*:*:*:*:*:*:*",
"matchCriteriaId": "7F322FCB-32F4-4C5A-A7F5-F7EF41188C88",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:wincc:6.0:sp2:*:*:*:*:*:*",
"matchCriteriaId": "69822DB4-DC79-4F88-A470-5AC512C77377",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:wincc:6.0:sp3:*:*:*:*:*:*",
"matchCriteriaId": "996DE8BD-DD51-41EF-9882-C2BD2CC5FE53",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:wincc:6.0:sp4:*:*:*:*:*:*",
"matchCriteriaId": "945C8B46-4CDA-4143-889C-30E30E93DB29",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:wincc:7.0:*:*:*:*:*:*:*",
"matchCriteriaId": "A33F9015-7058-419A-8762-CB2AE4ACF1A7",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:wincc:7.0:sp1:*:*:*:*:*:*",
"matchCriteriaId": "E6271FCC-CCF6-4D31-801A-B4B0DC4639DD",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:wincc:7.0:sp2:*:*:*:*:*:*",
"matchCriteriaId": "DF7A6B2B-D573-4285-B3B4-136F2BE7E710",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, stores sensitive information under the web root with insufficient access control, which allows remote attackers to read a (1) log file or (2) configuration file via a direct request."
},
{
"lang": "es",
"value": "WebNavigator en Siemens WinCC v7.0 SP3 y anteriores, como las usadas en SIMATIC PCS7 y otros productos, almacena informaci\u00f3n sensible bajo l directorio web raiz con un control de acceso no suficiente, lo que permite a atacantes remotos a leer (1) ficheros de registro o (2) ficheros de configuraci\u00f3n a trav\u00e9s de una petici\u00f3n directa."
}
],
"id": "CVE-2012-3030",
"lastModified": "2025-04-11T00:51:21.963",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
]
},
"published": "2012-09-18T14:55:01.443",
"references": [
{
"source": "ics-cert@hq.dhs.gov",
"url": "http://en.securitylab.ru/lab/PT-2012-43"
},
{
"source": "ics-cert@hq.dhs.gov",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-864051.pdf"
},
{
"source": "ics-cert@hq.dhs.gov",
"tags": [
"US Government Resource"
],
"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-256-01.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "http://en.securitylab.ru/lab/PT-2012-43"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-864051.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"US Government Resource"
],
"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-256-01.pdf"
}
],
"sourceIdentifier": "ics-cert@hq.dhs.gov",
"vulnStatus": "Deferred",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-264"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
GSD-2012-3030
Vulnerability from gsd - Updated: 2023-12-13 01:20{
"GSD": {
"alias": "CVE-2012-3030",
"description": "WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, stores sensitive information under the web root with insufficient access control, which allows remote attackers to read a (1) log file or (2) configuration file via a direct request.",
"id": "GSD-2012-3030"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2012-3030"
],
"details": "WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, stores sensitive information under the web root with insufficient access control, which allows remote attackers to read a (1) log file or (2) configuration file via a direct request.",
"id": "GSD-2012-3030",
"modified": "2023-12-13T01:20:20.258190Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2012-3030",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, stores sensitive information under the web root with insufficient access control, which allows remote attackers to read a (1) log file or (2) configuration file via a direct request."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-864051.pdf",
"refsource": "CONFIRM",
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-864051.pdf"
},
{
"name": "http://en.securitylab.ru/lab/PT-2012-43",
"refsource": "MISC",
"url": "http://en.securitylab.ru/lab/PT-2012-43"
},
{
"name": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-256-01.pdf",
"refsource": "MISC",
"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-256-01.pdf"
}
]
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:6.0:sp4:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:6.0:sp3:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_pcs7:8.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:6.0:sp2:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:*:sp3:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "7.0",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:7.0:sp2:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:7.0:sp1:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:7.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:6.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:5.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:5.0:sp1:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2012-3030"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, stores sensitive information under the web root with insufficient access control, which allows remote attackers to read a (1) log file or (2) configuration file via a direct request."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-264"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-256-01.pdf",
"refsource": "MISC",
"tags": [
"US Government Resource"
],
"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-256-01.pdf"
},
{
"name": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-864051.pdf",
"refsource": "CONFIRM",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-864051.pdf"
},
{
"name": "http://en.securitylab.ru/lab/PT-2012-43",
"refsource": "MISC",
"tags": [],
"url": "http://en.securitylab.ru/lab/PT-2012-43"
}
]
}
},
"impact": {
"baseMetricV2": {
"cvssV2": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"userInteractionRequired": false
}
},
"lastModifiedDate": "2012-12-20T05:00Z",
"publishedDate": "2012-09-18T14:55Z"
}
}
}
ICSA-12-256-01
Vulnerability from csaf_cisa - Published: 2012-06-16 06:00 - Updated: 2025-06-25 18:57{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"lang": "en-US",
"notes": [
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "general",
"text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov",
"title": "CISA Disclaimer"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the risk of exploitation.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Locate control system networks and remote devices behind firewalls and isolating them from business networks.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.",
"title": "Recommended Practices"
}
],
"publisher": {
"category": "coordinator",
"contact_details": "central@cisa.dhs.gov",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "ICS Advisory ICSA-12-256-01 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2012/icsa-12-256-01.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-12-256-01 - Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-12-256-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/topics/industrial-control-systems"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/sites/default/files/publications/emailscams0905.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ncas/tips/ST04-014"
}
],
"title": "Siemens WinCC WebNavigator Multiple Vulnerabilities",
"tracking": {
"current_release_date": "2025-06-25T18:57:28.717208Z",
"generator": {
"date": "2025-06-25T18:57:28.717149Z",
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-12-256-01",
"initial_release_date": "2012-06-16T06:00:00.000000Z",
"revision_history": [
{
"date": "2012-06-16T06:00:00.000000Z",
"legacy_version": "Initial",
"number": "1",
"summary": "Initial Publication"
},
{
"date": "2025-06-25T18:57:28.717208Z",
"legacy_version": "CSAF Conversion",
"number": "2",
"summary": "Advisory converted into a CSAF"
}
],
"status": "final",
"version": "2"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c=7.0_SP3",
"product": {
"name": "Siemens WebNavigator component of WinCC: \u003c=7.0_SP3",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "WebNavigator component of WinCC"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2012-3028",
"cwe": {
"id": "CWE-352",
"name": "Cross-Site Request Forgery (CSRF)"
},
"notes": [
{
"category": "summary",
"text": "Cross-site request forgery (CSRF) vulnerability in WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allows remote attackers to hijack the authentication of arbitrary users for requests that modify data or cause a denial of service.",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Siemens addresses these issues in a Siemens Security Advisory, SSA-864051. (https://cert-portal.siemens.com/productcert/pdf/ssa-864051.pdf)",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-864051.pdf"
},
{
"category": "mitigation",
"details": "Siemens provides an update for WinCC 7.0 SP3, which fixes vulnerabilities 1, 3, 4, and 5, and recommends installing the patch. Siemens also recommends users restrict access to WebNavigator, e.g., with a firewall or VPN gateway or to operate the service only within trusted networks.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "No patch is yet available for vulnerability 2",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Siemens recommends the following: Do not interact with other Internet-related services while being logged in. Log out when WebNavigator is not needed any more.",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v2": {
"baseScore": 7.8,
"vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:C",
"version": "2.0"
},
"products": [
"CSAFPID-0001"
]
}
]
},
{
"cve": "CVE-2012-3030",
"cwe": {
"id": "CWE-425",
"name": "Direct Request (\u0027Forced Browsing\u0027)"
},
"notes": [
{
"category": "summary",
"text": "WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, stores sensitive information under the web root with insufficient access control, which allows remote attackers to read a (1) log file or (2) configuration file via a direct request.",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Siemens addresses these issues in a Siemens Security Advisory, SSA-864051. (https://cert-portal.siemens.com/productcert/pdf/ssa-864051.pdf)",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-864051.pdf"
},
{
"category": "mitigation",
"details": "Siemens provides an update for WinCC 7.0 SP3, which fixes vulnerabilities 1, 3, 4, and 5, and recommends installing the patch. Siemens also recommends users restrict access to WebNavigator, e.g., with a firewall or VPN gateway or to operate the service only within trusted networks.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "No patch is yet available for vulnerability 2",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Siemens recommends the following: Do not interact with other Internet-related services while being logged in. Log out when WebNavigator is not needed any more.",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v2": {
"baseScore": 5.0,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
"products": [
"CSAFPID-0001"
]
}
]
},
{
"cve": "CVE-2012-3034",
"cwe": {
"id": "CWE-618",
"name": "Exposed Unsafe ActiveX Method"
},
"notes": [
{
"category": "summary",
"text": "WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allows remote attackers to discover a username and password via crafted parameters to unspecified methods in ActiveX controls.",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Siemens addresses these issues in a Siemens Security Advisory, SSA-864051. (https://cert-portal.siemens.com/productcert/pdf/ssa-864051.pdf)",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-864051.pdf"
},
{
"category": "mitigation",
"details": "Siemens provides an update for WinCC 7.0 SP3, which fixes vulnerabilities 1, 3, 4, and 5, and recommends installing the patch. Siemens also recommends users restrict access to WebNavigator, e.g., with a firewall or VPN gateway or to operate the service only within trusted networks.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "No patch is yet available for vulnerability 2",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Siemens recommends the following: Do not interact with other Internet-related services while being logged in. Log out when WebNavigator is not needed any more.",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v2": {
"baseScore": 8.3,
"vectorString": "AV:N/AC:M/Au:N/C:C/I:P/A:P",
"version": "2.0"
},
"products": [
"CSAFPID-0001"
]
}
]
},
{
"cve": "CVE-2012-3031",
"cwe": {
"id": "CWE-79",
"name": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)"
},
"notes": [
{
"category": "summary",
"text": "Multiple cross-site scripting (XSS) vulnerabilities in WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allow remote attackers to inject arbitrary web script or HTML via a (1) GET parameter, (2) POST parameter, or (3) Referer HTTP header.",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Siemens addresses these issues in a Siemens Security Advisory, SSA-864051. (https://cert-portal.siemens.com/productcert/pdf/ssa-864051.pdf)",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-864051.pdf"
},
{
"category": "mitigation",
"details": "Siemens provides an update for WinCC 7.0 SP3, which fixes vulnerabilities 1, 3, 4, and 5, and recommends installing the patch. Siemens also recommends users restrict access to WebNavigator, e.g., with a firewall or VPN gateway or to operate the service only within trusted networks.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "No patch is yet available for vulnerability 2",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Siemens recommends the following: Do not interact with other Internet-related services while being logged in. Log out when WebNavigator is not needed any more.",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v2": {
"baseScore": 8.3,
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:C",
"version": "2.0"
},
"products": [
"CSAFPID-0001"
]
}
]
},
{
"cve": "CVE-2012-3032",
"cwe": {
"id": "CWE-89",
"name": "Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)"
},
"notes": [
{
"category": "summary",
"text": "SQL injection vulnerability in WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allows remote attackers to execute arbitrary SQL commands via a crafted SOAP message.",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Siemens addresses these issues in a Siemens Security Advisory, SSA-864051. (https://cert-portal.siemens.com/productcert/pdf/ssa-864051.pdf)",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-864051.pdf"
},
{
"category": "mitigation",
"details": "Siemens provides an update for WinCC 7.0 SP3, which fixes vulnerabilities 1, 3, 4, and 5, and recommends installing the patch. Siemens also recommends users restrict access to WebNavigator, e.g., with a firewall or VPN gateway or to operate the service only within trusted networks.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "No patch is yet available for vulnerability 2",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Siemens recommends the following: Do not interact with other Internet-related services while being logged in. Log out when WebNavigator is not needed any more.",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v2": {
"baseScore": 9.0,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:C",
"version": "2.0"
},
"products": [
"CSAFPID-0001"
]
}
]
}
]
}
CERTA-2012-AVI-507
Vulnerability from certfr_avis - Published: 2012-09-14 - Updated: 2012-09-14
Cinq vulnérabilités ont été corrigées dans le système SCADA Siemens WinCC. Parmis elles :
- deux concernent des injections de code indirecte à distance (XSS) ;
- une permet de récupérer des données d'autres utilisateurs ;
- une concerne une injection de type SQL ;
- la dernière permet d'obtenir l'identifiant et le mot de passe d'un utilisateur au moyen d'un ActiveX.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
WinCC version 7.0 SP3 et antérieures.
| Vendor | Product | Description |
|---|
| Title | Publication Time | Tags | |
|---|---|---|---|
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [],
"affected_systems_content": "\u003cP\u003eWinCC version 7.0 SP3 et ant\u00e9rieures.\u003c/P\u003e",
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2012-3032",
"url": "https://www.cve.org/CVERecord?id=CVE-2012-3032"
},
{
"name": "CVE-2012-3034",
"url": "https://www.cve.org/CVERecord?id=CVE-2012-3034"
},
{
"name": "CVE-2012-3030",
"url": "https://www.cve.org/CVERecord?id=CVE-2012-3030"
},
{
"name": "CVE-2012-3028",
"url": "https://www.cve.org/CVERecord?id=CVE-2012-3028"
},
{
"name": "CVE-2012-3031",
"url": "https://www.cve.org/CVERecord?id=CVE-2012-3031"
}
],
"initial_release_date": "2012-09-14T00:00:00",
"last_revision_date": "2012-09-14T00:00:00",
"links": [
{
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-864051 du 10 septembre 2012 :",
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-864051.pdf"
}
],
"reference": "CERTA-2012-AVI-507",
"revisions": [
{
"description": "version initiale.",
"revision_date": "2012-09-14T00:00:00.000000"
}
],
"risks": [
{
"description": "Injection de code indirecte \u00e0 distance"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
}
],
"summary": "Cinq vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 corrig\u00e9es dans le syst\u00e8me SCADA \u003cspan\nclass=\"textit\"\u003eSiemens WinCC\u003c/span\u003e. Parmis elles :\n\n- deux concernent des injections de code indirecte \u00e0 distance (XSS) ;\n- une permet de r\u00e9cup\u00e9rer des donn\u00e9es d\u0027autres utilisateurs ;\n- une concerne une injection de type SQL ;\n- la derni\u00e8re permet d\u0027obtenir l\u0027identifiant et le mot de passe d\u0027un\n utilisateur au moyen d\u0027un \u003cspan class=\"textit\"\u003eActiveX\u003c/span\u003e.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans syst\u00e8me SCADA Siemens WinCC",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-864051 du 10 septembre 2012",
"url": null
}
]
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.