Action not permitted
Modal body text goes here.
Modal Title
Modal Body
CVE-2012-3021 (GCVE-0-2012-3021)
Vulnerability from cvelistv5 – Published: 2012-11-01 10:00 – Updated: 2024-08-06 19:50- n/a
| URL | Tags |
|---|---|
| http://www.securityfocus.com/bid/55935 | vdb-entryx_refsource_BID |
| http://www.us-cert.gov/control_systems/pdf/ICSA-1… | x_refsource_MISC |
| http://support.ge-ip.com/support/index?page=kbcha… | x_refsource_CONFIRM |
| http://support.ge-ip.com/support/resources/sites/… | x_refsource_CONFIRM |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T19:50:05.388Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "55935",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/55935"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-234-01.pdf"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://support.ge-ip.com/support/index?page=kbchannel\u0026id=S:KB15050"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://support.ge-ip.com/support/resources/sites/GE_FANUC_SUPPORT/content/live/KB/15000/KB15050/en_US/GEIP12-10%20Security%20Advisory%20-%20Proficy%20Portal%20rifsrvd.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2012-10-15T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "rifsrvd.exe in the Remote Interface Service in GE Intelligent Platforms Proficy Real-Time Information Portal 2.6 through 3.5 SP1 allows remote attackers to cause a denial of service (memory corruption and service crash) or possibly execute arbitrary code via long input data, a different vulnerability than CVE-2012-3010 and CVE-2012-3026."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2013-04-12T09:00:00.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"name": "55935",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/55935"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-234-01.pdf"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://support.ge-ip.com/support/index?page=kbchannel\u0026id=S:KB15050"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://support.ge-ip.com/support/resources/sites/GE_FANUC_SUPPORT/content/live/KB/15000/KB15050/en_US/GEIP12-10%20Security%20Advisory%20-%20Proficy%20Portal%20rifsrvd.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2012-3021",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "rifsrvd.exe in the Remote Interface Service in GE Intelligent Platforms Proficy Real-Time Information Portal 2.6 through 3.5 SP1 allows remote attackers to cause a denial of service (memory corruption and service crash) or possibly execute arbitrary code via long input data, a different vulnerability than CVE-2012-3010 and CVE-2012-3026."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "55935",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/55935"
},
{
"name": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-234-01.pdf",
"refsource": "MISC",
"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-234-01.pdf"
},
{
"name": "http://support.ge-ip.com/support/index?page=kbchannel\u0026id=S:KB15050",
"refsource": "CONFIRM",
"url": "http://support.ge-ip.com/support/index?page=kbchannel\u0026id=S:KB15050"
},
{
"name": "http://support.ge-ip.com/support/resources/sites/GE_FANUC_SUPPORT/content/live/KB/15000/KB15050/en_US/GEIP12-10%20Security%20Advisory%20-%20Proficy%20Portal%20rifsrvd.pdf",
"refsource": "CONFIRM",
"url": "http://support.ge-ip.com/support/resources/sites/GE_FANUC_SUPPORT/content/live/KB/15000/KB15050/en_US/GEIP12-10%20Security%20Advisory%20-%20Proficy%20Portal%20rifsrvd.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2012-3021",
"datePublished": "2012-11-01T10:00:00.000Z",
"dateReserved": "2012-05-30T00:00:00.000Z",
"dateUpdated": "2024-08-06T19:50:05.388Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2012-3021",
"date": "2026-07-26",
"epss": "0.05009",
"percentile": "0.91345"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2012-3021\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2012-11-01T10:44:45.420\",\"lastModified\":\"2026-04-29T01:13:23.040\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"rifsrvd.exe in the Remote Interface Service in GE Intelligent Platforms Proficy Real-Time Information Portal 2.6 through 3.5 SP1 allows remote attackers to cause a denial of service (memory corruption and service crash) or possibly execute arbitrary code via long input data, a different vulnerability than CVE-2012-3010 and CVE-2012-3026.\"},{\"lang\":\"es\",\"value\":\"rifsrvd.exe en la interfaz de servicio remoto en GE Intelligent Platforms Proficy Real-Time Information Portal v2.6 a v3.5 SP1 permite a atacantes remotos provocar una denegaci\u00f3n de servicio (corrupci\u00f3n de memoria y ca\u00edda del servicio) o posiblemente ejecutar c\u00f3digo de su elecci\u00f3n a trav\u00e9s de unos datos de entrada demasiado largos. Se trata de una vulnerabilidad diferentes a CVE-2012-3010 y CVE-2012 3026.\"}],\"metrics\":{\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:C/I:C/A:C\",\"baseScore\":10.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":10.0,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-20\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:ge:intelligent_platforms_proficy_real-time_information_portal:2.6:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B7331C96-F07B-4212-BFA7-ABC0DAA5A15E\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:ge:intelligent_platforms_proficy_real-time_information_portal:3.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"90BA73F6-F1BC-4815-8B13-4C12DF3BD698\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:ge:intelligent_platforms_proficy_real-time_information_portal:3.0:sp1:*:*:*:*:*:*\",\"matchCriteriaId\":\"4E809B65-55C7-41DF-84BD-B184689E4F66\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:ge:intelligent_platforms_proficy_real-time_information_portal:3.5:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C286676B-1F44-4A35-A666-5C8947D5DC21\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:ge:intelligent_platforms_proficy_real-time_information_portal:3.5:sp1:*:*:*:*:*:*\",\"matchCriteriaId\":\"651D81FD-2B13-42A7-8351-D153FF5D933C\"}]}]}],\"references\":[{\"url\":\"http://support.ge-ip.com/support/index?page=kbchannel\u0026id=S:KB15050\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"http://support.ge-ip.com/support/resources/sites/GE_FANUC_SUPPORT/content/live/KB/15000/KB15050/en_US/GEIP12-10%20Security%20Advisory%20-%20Proficy%20Portal%20rifsrvd.pdf\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"http://www.securityfocus.com/bid/55935\",\"source\":\"ics-cert@hq.dhs.gov\"},{\"url\":\"http://www.us-cert.gov/control_systems/pdf/ICSA-12-234-01.pdf\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"US Government Resource\"]},{\"url\":\"http://support.ge-ip.com/support/index?page=kbchannel\u0026id=S:KB15050\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"http://support.ge-ip.com/support/resources/sites/GE_FANUC_SUPPORT/content/live/KB/15000/KB15050/en_US/GEIP12-10%20Security%20Advisory%20-%20Proficy%20Portal%20rifsrvd.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"http://www.securityfocus.com/bid/55935\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"http://www.us-cert.gov/control_systems/pdf/ICSA-12-234-01.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"US Government Resource\"]}]}}"
}
}
FKIE_CVE-2012-3021
Vulnerability from fkie_nvd - Published: 2012-11-01 10:44 - Updated: 2026-06-16 23:42{
"affected": [
{
"affectedData": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"source": "ics-cert@hq.dhs.gov"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:ge:intelligent_platforms_proficy_real-time_information_portal:2.6:*:*:*:*:*:*:*",
"matchCriteriaId": "B7331C96-F07B-4212-BFA7-ABC0DAA5A15E",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:ge:intelligent_platforms_proficy_real-time_information_portal:3.0:*:*:*:*:*:*:*",
"matchCriteriaId": "90BA73F6-F1BC-4815-8B13-4C12DF3BD698",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:ge:intelligent_platforms_proficy_real-time_information_portal:3.0:sp1:*:*:*:*:*:*",
"matchCriteriaId": "4E809B65-55C7-41DF-84BD-B184689E4F66",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:ge:intelligent_platforms_proficy_real-time_information_portal:3.5:*:*:*:*:*:*:*",
"matchCriteriaId": "C286676B-1F44-4A35-A666-5C8947D5DC21",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:ge:intelligent_platforms_proficy_real-time_information_portal:3.5:sp1:*:*:*:*:*:*",
"matchCriteriaId": "651D81FD-2B13-42A7-8351-D153FF5D933C",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "rifsrvd.exe in the Remote Interface Service in GE Intelligent Platforms Proficy Real-Time Information Portal 2.6 through 3.5 SP1 allows remote attackers to cause a denial of service (memory corruption and service crash) or possibly execute arbitrary code via long input data, a different vulnerability than CVE-2012-3010 and CVE-2012-3026."
},
{
"lang": "es",
"value": "rifsrvd.exe en la interfaz de servicio remoto en GE Intelligent Platforms Proficy Real-Time Information Portal v2.6 a v3.5 SP1 permite a atacantes remotos provocar una denegaci\u00f3n de servicio (corrupci\u00f3n de memoria y ca\u00edda del servicio) o posiblemente ejecutar c\u00f3digo de su elecci\u00f3n a trav\u00e9s de unos datos de entrada demasiado largos. Se trata de una vulnerabilidad diferentes a CVE-2012-3010 y CVE-2012 3026."
}
],
"id": "CVE-2012-3021",
"lastModified": "2026-06-16T23:42:31.610",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 10.0,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
]
},
"published": "2012-11-01T10:44:45.420",
"references": [
{
"source": "ics-cert@hq.dhs.gov",
"tags": [
"Vendor Advisory"
],
"url": "http://support.ge-ip.com/support/index?page=kbchannel\u0026id=S:KB15050"
},
{
"source": "ics-cert@hq.dhs.gov",
"tags": [
"Vendor Advisory"
],
"url": "http://support.ge-ip.com/support/resources/sites/GE_FANUC_SUPPORT/content/live/KB/15000/KB15050/en_US/GEIP12-10%20Security%20Advisory%20-%20Proficy%20Portal%20rifsrvd.pdf"
},
{
"source": "ics-cert@hq.dhs.gov",
"url": "http://www.securityfocus.com/bid/55935"
},
{
"source": "ics-cert@hq.dhs.gov",
"tags": [
"US Government Resource"
],
"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-234-01.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "http://support.ge-ip.com/support/index?page=kbchannel\u0026id=S:KB15050"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "http://support.ge-ip.com/support/resources/sites/GE_FANUC_SUPPORT/content/live/KB/15000/KB15050/en_US/GEIP12-10%20Security%20Advisory%20-%20Proficy%20Portal%20rifsrvd.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "http://www.securityfocus.com/bid/55935"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"US Government Resource"
],
"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-234-01.pdf"
}
],
"sourceIdentifier": "ics-cert@hq.dhs.gov",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-20"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
GHSA-FQ45-PRXH-8CPQ
Vulnerability from github – Published: 2022-05-17 05:11 – Updated: 2022-05-17 05:11rifsrvd.exe in the Remote Interface Service in GE Intelligent Platforms Proficy Real-Time Information Portal 2.6 through 3.5 SP1 allows remote attackers to cause a denial of service (memory corruption and service crash) or possibly execute arbitrary code via long input data, a different vulnerability than CVE-2012-3010 and CVE-2012-3026.
{
"affected": [],
"aliases": [
"CVE-2012-3021"
],
"database_specific": {
"cwe_ids": [
"CWE-20"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2012-11-01T10:44:00Z",
"severity": "HIGH"
},
"details": "rifsrvd.exe in the Remote Interface Service in GE Intelligent Platforms Proficy Real-Time Information Portal 2.6 through 3.5 SP1 allows remote attackers to cause a denial of service (memory corruption and service crash) or possibly execute arbitrary code via long input data, a different vulnerability than CVE-2012-3010 and CVE-2012-3026.",
"id": "GHSA-fq45-prxh-8cpq",
"modified": "2022-05-17T05:11:40Z",
"published": "2022-05-17T05:11:40Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2012-3021"
},
{
"type": "WEB",
"url": "http://support.ge-ip.com/support/index?page=kbchannel\u0026id=S:KB15050"
},
{
"type": "WEB",
"url": "http://support.ge-ip.com/support/resources/sites/GE_FANUC_SUPPORT/content/live/KB/15000/KB15050/en_US/GEIP12-10%20Security%20Advisory%20-%20Proficy%20Portal%20rifsrvd.pdf"
},
{
"type": "WEB",
"url": "http://www.securityfocus.com/bid/55935"
},
{
"type": "WEB",
"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-234-01.pdf"
}
],
"schema_version": "1.4.0",
"severity": []
}
GSD-2012-3021
Vulnerability from gsd - Updated: 2023-12-13 01:20{
"GSD": {
"alias": "CVE-2012-3021",
"description": "rifsrvd.exe in the Remote Interface Service in GE Intelligent Platforms Proficy Real-Time Information Portal 2.6 through 3.5 SP1 allows remote attackers to cause a denial of service (memory corruption and service crash) or possibly execute arbitrary code via long input data, a different vulnerability than CVE-2012-3010 and CVE-2012-3026.",
"id": "GSD-2012-3021"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2012-3021"
],
"details": "rifsrvd.exe in the Remote Interface Service in GE Intelligent Platforms Proficy Real-Time Information Portal 2.6 through 3.5 SP1 allows remote attackers to cause a denial of service (memory corruption and service crash) or possibly execute arbitrary code via long input data, a different vulnerability than CVE-2012-3010 and CVE-2012-3026.",
"id": "GSD-2012-3021",
"modified": "2023-12-13T01:20:21.316396Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2012-3021",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "rifsrvd.exe in the Remote Interface Service in GE Intelligent Platforms Proficy Real-Time Information Portal 2.6 through 3.5 SP1 allows remote attackers to cause a denial of service (memory corruption and service crash) or possibly execute arbitrary code via long input data, a different vulnerability than CVE-2012-3010 and CVE-2012-3026."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "55935",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/55935"
},
{
"name": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-234-01.pdf",
"refsource": "MISC",
"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-234-01.pdf"
},
{
"name": "http://support.ge-ip.com/support/index?page=kbchannel\u0026id=S:KB15050",
"refsource": "CONFIRM",
"url": "http://support.ge-ip.com/support/index?page=kbchannel\u0026id=S:KB15050"
},
{
"name": "http://support.ge-ip.com/support/resources/sites/GE_FANUC_SUPPORT/content/live/KB/15000/KB15050/en_US/GEIP12-10%20Security%20Advisory%20-%20Proficy%20Portal%20rifsrvd.pdf",
"refsource": "CONFIRM",
"url": "http://support.ge-ip.com/support/resources/sites/GE_FANUC_SUPPORT/content/live/KB/15000/KB15050/en_US/GEIP12-10%20Security%20Advisory%20-%20Proficy%20Portal%20rifsrvd.pdf"
}
]
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:ge:intelligent_platforms_proficy_real-time_information_portal:2.6:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:ge:intelligent_platforms_proficy_real-time_information_portal:3.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:ge:intelligent_platforms_proficy_real-time_information_portal:3.5:sp1:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:ge:intelligent_platforms_proficy_real-time_information_portal:3.0:sp1:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:ge:intelligent_platforms_proficy_real-time_information_portal:3.5:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2012-3021"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "rifsrvd.exe in the Remote Interface Service in GE Intelligent Platforms Proficy Real-Time Information Portal 2.6 through 3.5 SP1 allows remote attackers to cause a denial of service (memory corruption and service crash) or possibly execute arbitrary code via long input data, a different vulnerability than CVE-2012-3010 and CVE-2012-3026."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-20"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://support.ge-ip.com/support/resources/sites/GE_FANUC_SUPPORT/content/live/KB/15000/KB15050/en_US/GEIP12-10%20Security%20Advisory%20-%20Proficy%20Portal%20rifsrvd.pdf",
"refsource": "CONFIRM",
"tags": [
"Vendor Advisory"
],
"url": "http://support.ge-ip.com/support/resources/sites/GE_FANUC_SUPPORT/content/live/KB/15000/KB15050/en_US/GEIP12-10%20Security%20Advisory%20-%20Proficy%20Portal%20rifsrvd.pdf"
},
{
"name": "http://support.ge-ip.com/support/index?page=kbchannel\u0026id=S:KB15050",
"refsource": "CONFIRM",
"tags": [
"Vendor Advisory"
],
"url": "http://support.ge-ip.com/support/index?page=kbchannel\u0026id=S:KB15050"
},
{
"name": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-234-01.pdf",
"refsource": "MISC",
"tags": [
"US Government Resource"
],
"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-234-01.pdf"
},
{
"name": "55935",
"refsource": "BID",
"tags": [],
"url": "http://www.securityfocus.com/bid/55935"
}
]
}
},
"impact": {
"baseMetricV2": {
"cvssV2": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 10.0,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "HIGH",
"userInteractionRequired": false
}
},
"lastModifiedDate": "2013-04-13T02:55Z",
"publishedDate": "2012-11-01T10:44Z"
}
}
}
ICSA-12-234-01
Vulnerability from csaf_cisa - Published: 2012-05-25 06:00 - Updated: 2025-06-05 21:52| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
GE Intelligent Platforms Proficy Real-Time Information Portal: v2.6
GE / Intelligent Platforms Proficy Real-Time Information Portal
|
v2.6 |
Mitigation
Mitigation
|
|
|
GE Intelligent Platforms Proficy Real-Time Information Portal: v3.0
GE / Intelligent Platforms Proficy Real-Time Information Portal
|
v3.0 |
Mitigation
Mitigation
|
|
|
GE Intelligent Platforms Proficy Real-Time Information Portal: v3.0_SP1
GE / Intelligent Platforms Proficy Real-Time Information Portal
|
v3.0_SP1 |
Mitigation
Mitigation
|
|
|
GE Intelligent Platforms Proficy Real-Time Information Portal: v3.5
GE / Intelligent Platforms Proficy Real-Time Information Portal
|
v3.5 |
Mitigation
Mitigation
|
|
|
GE Intelligent Platforms Proficy Real-Time Information Portal: v3.5_SP1.
GE / Intelligent Platforms Proficy Real-Time Information Portal
|
v3.5_SP1. |
Mitigation
Mitigation
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
GE Intelligent Platforms Proficy Real-Time Information Portal: v2.6
GE / Intelligent Platforms Proficy Real-Time Information Portal
|
v2.6 |
Mitigation
Mitigation
|
|
|
GE Intelligent Platforms Proficy Real-Time Information Portal: v3.0
GE / Intelligent Platforms Proficy Real-Time Information Portal
|
v3.0 |
Mitigation
Mitigation
|
|
|
GE Intelligent Platforms Proficy Real-Time Information Portal: v3.0_SP1
GE / Intelligent Platforms Proficy Real-Time Information Portal
|
v3.0_SP1 |
Mitigation
Mitigation
|
|
|
GE Intelligent Platforms Proficy Real-Time Information Portal: v3.5
GE / Intelligent Platforms Proficy Real-Time Information Portal
|
v3.5 |
Mitigation
Mitigation
|
|
|
GE Intelligent Platforms Proficy Real-Time Information Portal: v3.5_SP1.
GE / Intelligent Platforms Proficy Real-Time Information Portal
|
v3.5_SP1. |
Mitigation
Mitigation
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
GE Intelligent Platforms Proficy Real-Time Information Portal: v2.6
GE / Intelligent Platforms Proficy Real-Time Information Portal
|
v2.6 |
Mitigation
Mitigation
|
|
|
GE Intelligent Platforms Proficy Real-Time Information Portal: v3.0
GE / Intelligent Platforms Proficy Real-Time Information Portal
|
v3.0 |
Mitigation
Mitigation
|
|
|
GE Intelligent Platforms Proficy Real-Time Information Portal: v3.0_SP1
GE / Intelligent Platforms Proficy Real-Time Information Portal
|
v3.0_SP1 |
Mitigation
Mitigation
|
|
|
GE Intelligent Platforms Proficy Real-Time Information Portal: v3.5
GE / Intelligent Platforms Proficy Real-Time Information Portal
|
v3.5 |
Mitigation
Mitigation
|
|
|
GE Intelligent Platforms Proficy Real-Time Information Portal: v3.5_SP1.
GE / Intelligent Platforms Proficy Real-Time Information Portal
|
v3.5_SP1. |
Mitigation
Mitigation
|
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"lang": "en-US",
"notes": [
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "general",
"text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov",
"title": "CISA Disclaimer"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the risk of exploitation.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Locate control system networks and remote devices behind firewalls and isolating them from business networks.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.",
"title": "Recommended Practices"
}
],
"publisher": {
"category": "coordinator",
"contact_details": "central@cisa.dhs.gov",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "ICS Advisory ICSA-12-234-01 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2012/icsa-12-234-01.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-12-234-01 - Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-12-234-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/topics/industrial-control-systems"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/sites/default/files/publications/emailscams0905.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ncas/tips/ST04-014"
}
],
"title": "GE Intelligent Platforms Proficy Real-Time Information Portal Vulnerabilities",
"tracking": {
"current_release_date": "2025-06-05T21:52:26.050859Z",
"generator": {
"date": "2025-06-05T21:52:26.050741Z",
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-12-234-01",
"initial_release_date": "2012-05-25T06:00:00.000000Z",
"revision_history": [
{
"date": "2012-05-25T06:00:00.000000Z",
"legacy_version": "Initial",
"number": "1",
"summary": "Initial Publication"
},
{
"date": "2025-06-05T21:52:26.050859Z",
"legacy_version": "CSAF Conversion",
"number": "2",
"summary": "Advisory converted into a CSAF"
}
],
"status": "final",
"version": "2"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version",
"name": "v2.6",
"product": {
"name": "GE Intelligent Platforms Proficy Real-Time Information Portal: v2.6",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "Intelligent Platforms Proficy Real-Time Information Portal"
},
{
"branches": [
{
"category": "product_version",
"name": "v3.0",
"product": {
"name": "GE Intelligent Platforms Proficy Real-Time Information Portal: v3.0",
"product_id": "CSAFPID-0002"
}
}
],
"category": "product_name",
"name": "Intelligent Platforms Proficy Real-Time Information Portal"
},
{
"branches": [
{
"category": "product_version",
"name": "v3.0_SP1",
"product": {
"name": "GE Intelligent Platforms Proficy Real-Time Information Portal: v3.0_SP1",
"product_id": "CSAFPID-0003"
}
}
],
"category": "product_name",
"name": "Intelligent Platforms Proficy Real-Time Information Portal"
},
{
"branches": [
{
"category": "product_version",
"name": "v3.5",
"product": {
"name": "GE Intelligent Platforms Proficy Real-Time Information Portal: v3.5",
"product_id": "CSAFPID-0004"
}
}
],
"category": "product_name",
"name": "Intelligent Platforms Proficy Real-Time Information Portal"
},
{
"branches": [
{
"category": "product_version",
"name": "v3.5_SP1.",
"product": {
"name": "GE Intelligent Platforms Proficy Real-Time Information Portal: v3.5_SP1.",
"product_id": "CSAFPID-0005"
}
}
],
"category": "product_name",
"name": "Intelligent Platforms Proficy Real-Time Information Portal"
}
],
"category": "vendor",
"name": "GE"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2012-3010",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"category": "summary",
"text": "rifsrvd.exe in the Remote Interface Service in GE Intelligent Platforms Proficy Real-Time Information Portal 2.6 through 3.5 SP1 allows remote attackers to cause a denial of service (memory corruption and service crash) or possibly execute arbitrary code via long input data, a different vulnerability than CVE-2012-3021 and CVE-2012-3026.",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005"
]
},
"remediations": [
{
"category": "mitigation",
"details": "GE has released a security advisory and patches that fix the vulnerabilities in Versions 3.5 SP1, 3.5, and 3.0 SP1. The currently available patches can be found at GE\u2019s Intelligent Platforms Software Download Web Sites listed below: Proficy Real-Time Information Portal 3.5 SP1 SIM 1, Proficy Real-Time Information Portal 3.5 SIM 17, Proficy Real-Time Information Portal 3.0 SP1 SIM 44 Note: Proficy SIMs are cumulative. All future SIMs will include these updates.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005"
]
},
{
"category": "mitigation",
"details": "Proficy Real-Time Information Portal customers using Versions 3.0 and 2.6 are encouraged to upgrade to one of the versions described above and apply the appropriate product update.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005"
]
}
],
"scores": [
{
"cvss_v2": {
"baseScore": 7.1,
"vectorString": "AV:N/AC:M/Au:N/C:N/I:N/A:C",
"version": "2.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005"
]
}
]
},
{
"cve": "CVE-2012-3021",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"category": "summary",
"text": "rifsrvd.exe in the Remote Interface Service in GE Intelligent Platforms Proficy Real-Time Information Portal 2.6 through 3.5 SP1 allows remote attackers to cause a denial of service (memory corruption and service crash) or possibly execute arbitrary code via long input data, a different vulnerability than CVE-2012-3010 and CVE-2012-3026.",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005"
]
},
"remediations": [
{
"category": "mitigation",
"details": "GE has released a security advisory and patches that fix the vulnerabilities in Versions 3.5 SP1, 3.5, and 3.0 SP1. The currently available patches can be found at GE\u2019s Intelligent Platforms Software Download Web Sites listed below: Proficy Real-Time Information Portal 3.5 SP1 SIM 1, Proficy Real-Time Information Portal 3.5 SIM 17, Proficy Real-Time Information Portal 3.0 SP1 SIM 44 Note: Proficy SIMs are cumulative. All future SIMs will include these updates.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005"
]
},
{
"category": "mitigation",
"details": "Proficy Real-Time Information Portal customers using Versions 3.0 and 2.6 are encouraged to upgrade to one of the versions described above and apply the appropriate product update.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005"
]
}
],
"scores": [
{
"cvss_v2": {
"baseScore": 7.1,
"vectorString": "AV:N/AC:M/Au:N/C:N/I:N/A:C",
"version": "2.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005"
]
}
]
},
{
"cve": "CVE-2012-3026",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"category": "summary",
"text": "rifsrvd.exe in the Remote Interface Service in GE Intelligent Platforms Proficy Real-Time Information Portal 2.6 through 3.5 SP1 allows remote attackers to cause a denial of service (memory corruption and service crash) or possibly execute arbitrary code via long input data, a different vulnerability than CVE-2012-3010 and CVE-2012-3021.",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005"
]
},
"remediations": [
{
"category": "mitigation",
"details": "GE has released a security advisory and patches that fix the vulnerabilities in Versions 3.5 SP1, 3.5, and 3.0 SP1. The currently available patches can be found at GE\u2019s Intelligent Platforms Software Download Web Sites listed below: Proficy Real-Time Information Portal 3.5 SP1 SIM 1, Proficy Real-Time Information Portal 3.5 SIM 17, Proficy Real-Time Information Portal 3.0 SP1 SIM 44 Note: Proficy SIMs are cumulative. All future SIMs will include these updates.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005"
]
},
{
"category": "mitigation",
"details": "Proficy Real-Time Information Portal customers using Versions 3.0 and 2.6 are encouraged to upgrade to one of the versions described above and apply the appropriate product update.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005"
]
}
],
"scores": [
{
"cvss_v2": {
"baseScore": 7.1,
"vectorString": "AV:N/AC:M/Au:N/C:N/I:N/A:C",
"version": "2.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003",
"CSAFPID-0004",
"CSAFPID-0005"
]
}
]
}
]
}
VAR-201211-0176
Vulnerability from variot - Updated: 2025-04-11 23:08rifsrvd.exe in the Remote Interface Service in GE Intelligent Platforms Proficy Real-Time Information Portal 2.6 through 3.5 SP1 allows remote attackers to cause a denial of service (memory corruption and service crash) or possibly execute arbitrary code via long input data, a different vulnerability than CVE-2012-3010 and CVE-2012-3026. GE Proficy Real-Time Information Portal is a Proficy real-time information portal, a real-time manufacturing intelligence application for GE Intelligent Platforms. Because the service fails to properly check the input data submitted by the user, the attacker is allowed to send malicious requests for denial of service attacks. Remote attackers may exploit this issue to crash the affected application, denying service to legitimate users. Due to the nature of this issue, arbitrary code execution may be possible; this has not been confirmed. ----------------------------------------------------------------------
The final version of the CSI 6.0 has been released. Find out why this is not just another Patch Management solution: http://secunia.com/blog/325/
TITLE: Proficy Real-Time Information Portal Multiple Vulnerabilities
SECUNIA ADVISORY ID: SA50962
VERIFY ADVISORY: Secunia.com http://secunia.com/advisories/50962/ Customer Area (Credentials Required) https://ca.secunia.com/?page=viewadvisory&vuln_id=50962
RELEASE DATE: 2012-10-16
DISCUSS ADVISORY: http://secunia.com/advisories/50962/#comments
AVAILABLE ON SITE AND IN CUSTOMER AREA: * Last Update * Popularity * Comments * Criticality Level * Impact * Where * Solution Status * Operating System / Software * CVE Reference(s)
http://secunia.com/advisories/50962/
ONLY AVAILABLE IN CUSTOMER AREA: * Authentication Level * Report Reliability * Secunia PoC * Secunia Analysis * Systems Affected * Approve Distribution * Remediation Status * Secunia CVSS Score * CVSS
https://ca.secunia.com/?page=viewadvisory&vuln_id=50962
ONLY AVAILABLE WITH SECUNIA CSI AND SECUNIA PSI: * AUTOMATED SCANNING
http://secunia.com/vulnerability_scanning/personal/ http://secunia.com/vulnerability_scanning/corporate/wsus_sccm_3rd_third_party_patching/
DESCRIPTION: Multiple vulnerabilities have been reported in Proficy Real-Time Information Portal, which can be exploited by malicious people to cause a DoS (Denial of Service) and potentially compromise a vulnerable system.
The vulnerabilities are reported in version 2.6, 3.0, 3.0 SP1, 3.5, and 3.5 SP1.
SOLUTION: Reportedly patches have been released. Contact the vendor for further information.
PROVIDED AND/OR DISCOVERED BY: Kuang-Chun Hung, Information and Communication Security Technology Center (ICST).
ORIGINAL ADVISORY: ICS-CERT: http://www.us-cert.gov/control_systems/pdf/ICSA-12-234-01.pdf
OTHER REFERENCES: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
DEEP LINKS: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
EXTENDED DESCRIPTION: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
EXTENDED SOLUTION: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
EXPLOIT: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
About: This Advisory was delivered by Secunia as a free service to help private users keeping their systems up to date against the latest vulnerabilities.
Subscribe: http://secunia.com/advisories/secunia_security_advisories/
Definitions: (Criticality, Where etc.) http://secunia.com/advisories/about_secunia_advisories/
Please Note: Secunia recommends that you verify all advisories you receive by clicking the link. Secunia NEVER sends attached files with advisories. Secunia does not advise people to install third party patches, only use those supplied by the vendor.
Unsubscribe: Secunia Security Advisories http://secunia.com/sec_adv_unsubscribe/?email=packet%40packetstormsecurity.org
Show details on source website
{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201211-0176",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "intelligent platforms proficy real-time information portal",
"scope": "eq",
"trust": 1.6,
"vendor": "ge",
"version": "2.6"
},
{
"model": "intelligent platforms proficy real-time information portal",
"scope": "eq",
"trust": 1.6,
"vendor": "ge",
"version": "3.0"
},
{
"model": "intelligent platforms proficy real-time information portal",
"scope": "eq",
"trust": 1.6,
"vendor": "ge",
"version": "3.5"
},
{
"model": "proficy real-time information portal",
"scope": "eq",
"trust": 0.8,
"vendor": "general electric",
"version": "2.6 to 3.5 sp1"
},
{
"model": "proficy real-time information portal",
"scope": "eq",
"trust": 0.6,
"vendor": "ge fanuc automation",
"version": "2.6"
},
{
"model": "proficy real-time information portal",
"scope": "eq",
"trust": 0.6,
"vendor": "ge fanuc automation",
"version": "3.0"
},
{
"model": "proficy real-time information portal sp1",
"scope": "eq",
"trust": 0.6,
"vendor": "ge fanuc automation",
"version": "3.0"
},
{
"model": "proficy real-time information portal",
"scope": "eq",
"trust": 0.6,
"vendor": "ge fanuc automation",
"version": "3.5"
},
{
"model": null,
"scope": "eq",
"trust": 0.4,
"vendor": "intelligent platforms proficy real time information portal",
"version": "3.0"
},
{
"model": null,
"scope": "eq",
"trust": 0.4,
"vendor": "intelligent platforms proficy real time information portal",
"version": "3.5"
},
{
"model": "electric proficy real-time information portal",
"scope": "eq",
"trust": 0.3,
"vendor": "general",
"version": "3.5"
},
{
"model": "electric proficy real-time information portal sp1",
"scope": "eq",
"trust": 0.3,
"vendor": "general",
"version": "3.0"
},
{
"model": "electric proficy real-time information portal",
"scope": "eq",
"trust": 0.3,
"vendor": "general",
"version": "3.0"
},
{
"model": "electric proficy real-time information portal",
"scope": "eq",
"trust": 0.3,
"vendor": "general",
"version": "2.6"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "intelligent platforms proficy real time information portal",
"version": "2.6"
}
],
"sources": [
{
"db": "IVD",
"id": "47098e0e-2353-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2012-5847"
},
{
"db": "BID",
"id": "55935"
},
{
"db": "JVNDB",
"id": "JVNDB-2012-005174"
},
{
"db": "CNNVD",
"id": "CNNVD-201210-385"
},
{
"db": "NVD",
"id": "CVE-2012-3021"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"cpe_match": [
{
"cpe22Uri": "cpe:/a:ge:intelligent_platforms_proficy_real-time_information_portal",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2012-005174"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Kuang-Chun Hung of Information and Communication Security Technology Center",
"sources": [
{
"db": "BID",
"id": "55935"
}
],
"trust": 0.3
},
"cve": "CVE-2012-3021",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "nvd@nist.gov",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CVE-2012-3021",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 1.9,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "IVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "47098e0e-2353-11e6-abef-000c29c66e3d",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.2,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.9 [IVD]"
}
],
"cvssV3": [],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2012-3021",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "NVD",
"id": "CVE-2012-3021",
"trust": 0.8,
"value": "High"
},
{
"author": "CNNVD",
"id": "CNNVD-201210-385",
"trust": 0.6,
"value": "CRITICAL"
},
{
"author": "IVD",
"id": "47098e0e-2353-11e6-abef-000c29c66e3d",
"trust": 0.2,
"value": "CRITICAL"
},
{
"author": "VULMON",
"id": "CVE-2012-3021",
"trust": 0.1,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "IVD",
"id": "47098e0e-2353-11e6-abef-000c29c66e3d"
},
{
"db": "VULMON",
"id": "CVE-2012-3021"
},
{
"db": "JVNDB",
"id": "JVNDB-2012-005174"
},
{
"db": "CNNVD",
"id": "CNNVD-201210-385"
},
{
"db": "NVD",
"id": "CVE-2012-3021"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "rifsrvd.exe in the Remote Interface Service in GE Intelligent Platforms Proficy Real-Time Information Portal 2.6 through 3.5 SP1 allows remote attackers to cause a denial of service (memory corruption and service crash) or possibly execute arbitrary code via long input data, a different vulnerability than CVE-2012-3010 and CVE-2012-3026. GE Proficy Real-Time Information Portal is a Proficy real-time information portal, a real-time manufacturing intelligence application for GE Intelligent Platforms. Because the service fails to properly check the input data submitted by the user, the attacker is allowed to send malicious requests for denial of service attacks. \nRemote attackers may exploit this issue to crash the affected application, denying service to legitimate users. Due to the nature of this issue, arbitrary code execution may be possible; this has not been confirmed. ----------------------------------------------------------------------\n\nThe final version of the CSI 6.0 has been released. \nFind out why this is not just another Patch Management solution: http://secunia.com/blog/325/\n\n----------------------------------------------------------------------\n\nTITLE:\nProficy Real-Time Information Portal Multiple Vulnerabilities\n\nSECUNIA ADVISORY ID:\nSA50962\n\nVERIFY ADVISORY:\nSecunia.com\nhttp://secunia.com/advisories/50962/\nCustomer Area (Credentials Required)\nhttps://ca.secunia.com/?page=viewadvisory\u0026vuln_id=50962\n\nRELEASE DATE:\n2012-10-16\n\nDISCUSS ADVISORY:\nhttp://secunia.com/advisories/50962/#comments\n\nAVAILABLE ON SITE AND IN CUSTOMER AREA:\n * Last Update\n * Popularity\n * Comments\n * Criticality Level\n * Impact\n * Where\n * Solution Status\n * Operating System / Software\n * CVE Reference(s)\n\nhttp://secunia.com/advisories/50962/\n\nONLY AVAILABLE IN CUSTOMER AREA:\n * Authentication Level\n * Report Reliability\n * Secunia PoC\n * Secunia Analysis\n * Systems Affected\n * Approve Distribution\n * Remediation Status\n * Secunia CVSS Score\n * CVSS\n\nhttps://ca.secunia.com/?page=viewadvisory\u0026vuln_id=50962\n\nONLY AVAILABLE WITH SECUNIA CSI AND SECUNIA PSI:\n * AUTOMATED SCANNING\n\nhttp://secunia.com/vulnerability_scanning/personal/\nhttp://secunia.com/vulnerability_scanning/corporate/wsus_sccm_3rd_third_party_patching/\n\nDESCRIPTION:\nMultiple vulnerabilities have been reported in Proficy Real-Time\nInformation Portal, which can be exploited by malicious people to\ncause a DoS (Denial of Service) and potentially compromise a\nvulnerable system. \n\nThe vulnerabilities are reported in version 2.6, 3.0, 3.0 SP1, 3.5,\nand 3.5 SP1. \n\nSOLUTION:\nReportedly patches have been released. Contact the vendor for further\ninformation. \n\nPROVIDED AND/OR DISCOVERED BY:\nKuang-Chun Hung, Information and Communication Security Technology\nCenter (ICST). \n\nORIGINAL ADVISORY:\nICS-CERT:\nhttp://www.us-cert.gov/control_systems/pdf/ICSA-12-234-01.pdf\n\nOTHER REFERENCES:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\nDEEP LINKS:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\nEXTENDED DESCRIPTION:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\nEXTENDED SOLUTION:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\nEXPLOIT:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\n----------------------------------------------------------------------\n\nAbout:\nThis Advisory was delivered by Secunia as a free service to help\nprivate users keeping their systems up to date against the latest\nvulnerabilities. \n\nSubscribe:\nhttp://secunia.com/advisories/secunia_security_advisories/\n\nDefinitions: (Criticality, Where etc.)\nhttp://secunia.com/advisories/about_secunia_advisories/\n\n\nPlease Note:\nSecunia recommends that you verify all advisories you receive by\nclicking the link. \nSecunia NEVER sends attached files with advisories. \nSecunia does not advise people to install third party patches, only\nuse those supplied by the vendor. \n\n----------------------------------------------------------------------\n\nUnsubscribe: Secunia Security Advisories\nhttp://secunia.com/sec_adv_unsubscribe/?email=packet%40packetstormsecurity.org\n\n----------------------------------------------------------------------\n\n\n",
"sources": [
{
"db": "NVD",
"id": "CVE-2012-3021"
},
{
"db": "JVNDB",
"id": "JVNDB-2012-005174"
},
{
"db": "CNVD",
"id": "CNVD-2012-5847"
},
{
"db": "BID",
"id": "55935"
},
{
"db": "IVD",
"id": "47098e0e-2353-11e6-abef-000c29c66e3d"
},
{
"db": "VULMON",
"id": "CVE-2012-3021"
},
{
"db": "PACKETSTORM",
"id": "117410"
}
],
"trust": 2.79
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2012-3021",
"trust": 3.6
},
{
"db": "ICS CERT",
"id": "ICSA-12-234-01",
"trust": 2.6
},
{
"db": "SECUNIA",
"id": "50962",
"trust": 1.4
},
{
"db": "BID",
"id": "55935",
"trust": 1.4
},
{
"db": "CNVD",
"id": "CNVD-2012-5847",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-201210-385",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2012-005174",
"trust": 0.8
},
{
"db": "IVD",
"id": "47098E0E-2353-11E6-ABEF-000C29C66E3D",
"trust": 0.2
},
{
"db": "VULMON",
"id": "CVE-2012-3021",
"trust": 0.1
},
{
"db": "PACKETSTORM",
"id": "117410",
"trust": 0.1
}
],
"sources": [
{
"db": "IVD",
"id": "47098e0e-2353-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2012-5847"
},
{
"db": "VULMON",
"id": "CVE-2012-3021"
},
{
"db": "BID",
"id": "55935"
},
{
"db": "JVNDB",
"id": "JVNDB-2012-005174"
},
{
"db": "PACKETSTORM",
"id": "117410"
},
{
"db": "CNNVD",
"id": "CNNVD-201210-385"
},
{
"db": "NVD",
"id": "CVE-2012-3021"
}
]
},
"id": "VAR-201211-0176",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "IVD",
"id": "47098e0e-2353-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2012-5847"
}
],
"trust": 1.51428573
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.8
}
],
"sources": [
{
"db": "IVD",
"id": "47098e0e-2353-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2012-5847"
}
]
},
"last_update_date": "2025-04-11T23:08:48.510000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "GEIP12-10",
"trust": 0.8,
"url": "http://support.ge-ip.com/support/index?page=kbchannel\u0026id=S:KB15050"
},
{
"title": "Multiple vulnerabilities in Proficy Portal Remote Interface Service",
"trust": 0.8,
"url": "http://support.ge-ip.com/support/resources/sites/GE_FANUC_SUPPORT/content/live/KB/15000/KB15050/en_US/GEIP12-10%20Security%20Advisory%20-%20Proficy%20Portal%20rifsrvd.pdf"
},
{
"title": "Patch for GE Proficy Real-Time Information Portal Denial of Service Vulnerability (CNVD-2012-5847)",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/23757"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2012-5847"
},
{
"db": "JVNDB",
"id": "JVNDB-2012-005174"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-20",
"trust": 1.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2012-005174"
},
{
"db": "NVD",
"id": "CVE-2012-3021"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.6,
"url": "http://www.us-cert.gov/control_systems/pdf/icsa-12-234-01.pdf"
},
{
"trust": 1.7,
"url": "http://support.ge-ip.com/support/resources/sites/ge_fanuc_support/content/live/kb/15000/kb15050/en_us/geip12-10%20security%20advisory%20-%20proficy%20portal%20rifsrvd.pdf"
},
{
"trust": 1.7,
"url": "http://support.ge-ip.com/support/index?page=kbchannel\u0026id=s:kb15050"
},
{
"trust": 1.1,
"url": "http://www.securityfocus.com/bid/55935"
},
{
"trust": 0.8,
"url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2012-3021"
},
{
"trust": 0.8,
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2012-3021"
},
{
"trust": 0.6,
"url": "http://secunia.com/advisories/50962/http"
},
{
"trust": 0.6,
"url": "http://secunia.com/advisories/50962"
},
{
"trust": 0.3,
"url": "http://www.ge-ip.com/products/2811"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/20.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
},
{
"trust": 0.1,
"url": "http://tools.cisco.com/security/center/viewalert.x?alertid=27198"
},
{
"trust": 0.1,
"url": "https://ics-cert.us-cert.gov/advisories/icsa-12-234-01"
},
{
"trust": 0.1,
"url": "http://secunia.com/vulnerability_intelligence/"
},
{
"trust": 0.1,
"url": "http://secunia.com/advisories/secunia_security_advisories/"
},
{
"trust": 0.1,
"url": "http://secunia.com/vulnerability_scanning/corporate/wsus_sccm_3rd_third_party_patching/"
},
{
"trust": 0.1,
"url": "http://secunia.com/advisories/50962/#comments"
},
{
"trust": 0.1,
"url": "https://ca.secunia.com/?page=viewadvisory\u0026vuln_id=50962"
},
{
"trust": 0.1,
"url": "http://secunia.com/advisories/50962/"
},
{
"trust": 0.1,
"url": "http://secunia.com/vulnerability_scanning/personal/"
},
{
"trust": 0.1,
"url": "http://secunia.com/sec_adv_unsubscribe/?email=packet%40packetstormsecurity.org"
},
{
"trust": 0.1,
"url": "http://secunia.com/blog/325/"
},
{
"trust": 0.1,
"url": "http://secunia.com/advisories/about_secunia_advisories/"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2012-5847"
},
{
"db": "VULMON",
"id": "CVE-2012-3021"
},
{
"db": "BID",
"id": "55935"
},
{
"db": "JVNDB",
"id": "JVNDB-2012-005174"
},
{
"db": "PACKETSTORM",
"id": "117410"
},
{
"db": "CNNVD",
"id": "CNNVD-201210-385"
},
{
"db": "NVD",
"id": "CVE-2012-3021"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "IVD",
"id": "47098e0e-2353-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2012-5847"
},
{
"db": "VULMON",
"id": "CVE-2012-3021"
},
{
"db": "BID",
"id": "55935"
},
{
"db": "JVNDB",
"id": "JVNDB-2012-005174"
},
{
"db": "PACKETSTORM",
"id": "117410"
},
{
"db": "CNNVD",
"id": "CNNVD-201210-385"
},
{
"db": "NVD",
"id": "CVE-2012-3021"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2012-10-19T00:00:00",
"db": "IVD",
"id": "47098e0e-2353-11e6-abef-000c29c66e3d"
},
{
"date": "2012-10-19T00:00:00",
"db": "CNVD",
"id": "CNVD-2012-5847"
},
{
"date": "2012-11-01T00:00:00",
"db": "VULMON",
"id": "CVE-2012-3021"
},
{
"date": "2012-10-15T00:00:00",
"db": "BID",
"id": "55935"
},
{
"date": "2012-11-02T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2012-005174"
},
{
"date": "2012-10-16T06:20:48",
"db": "PACKETSTORM",
"id": "117410"
},
{
"date": "2012-10-18T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201210-385"
},
{
"date": "2012-11-01T10:44:45.420000",
"db": "NVD",
"id": "CVE-2012-3021"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2012-10-19T00:00:00",
"db": "CNVD",
"id": "CNVD-2012-5847"
},
{
"date": "2013-04-13T00:00:00",
"db": "VULMON",
"id": "CVE-2012-3021"
},
{
"date": "2012-10-15T00:00:00",
"db": "BID",
"id": "55935"
},
{
"date": "2012-11-02T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2012-005174"
},
{
"date": "2012-11-02T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201210-385"
},
{
"date": "2025-04-11T00:51:21.963000",
"db": "NVD",
"id": "CVE-2012-3021"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201210-385"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "GE Intelligent Platforms Proficy Real-Time Information Portal Service disruption in (DoS) Vulnerabilities",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2012-005174"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Input validation",
"sources": [
{
"db": "IVD",
"id": "47098e0e-2353-11e6-abef-000c29c66e3d"
},
{
"db": "CNNVD",
"id": "CNNVD-201210-385"
}
],
"trust": 0.8
}
}
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.