CVE-2012-0195 (GCVE-0-2012-0195)
Vulnerability from cvelistv5 – Published: 2012-03-13 01:00 – Updated: 2024-08-06 18:16
VLAI
Summary
Cross-site scripting (XSS) vulnerability in the Start Center Layout and Configuration component in IBM Maximo Asset Management and Asset Management Essentials 6.2, 7.1, and 7.5; IBM Tivoli Asset Management for IT 6.2, 7.1, and 7.2; IBM Tivoli Service Request Manager 7.1 and 7.2; IBM Maximo Service Desk 6.2; and IBM Tivoli Change and Configuration Management Database (CCMDB) 6.2, 7.1, and 7.2 allows remote attackers to inject arbitrary web script or HTML via the display name.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
6 references
| URL | Tags |
|---|---|
| http://www.ibm.com/support/docview.wss?uid=swg21584666 | x_refsource_CONFIRM |
| http://secunia.com/advisories/48299 | third-party-advisoryx_refsource_SECUNIA |
| http://www-01.ibm.com/support/docview.wss?uid=swg… | vendor-advisoryx_refsource_AIXAPAR |
| http://secunia.com/advisories/48305 | third-party-advisoryx_refsource_SECUNIA |
| http://www.securityfocus.com/bid/52333 | vdb-entryx_refsource_BID |
| https://exchange.xforce.ibmcloud.com/vulnerabilit… | vdb-entryx_refsource_XF |
Date Public
2012-02-14 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T18:16:19.457Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.ibm.com/support/docview.wss?uid=swg21584666"
},
{
"name": "48299",
"tags": [
"third-party-advisory",
"x_refsource_SECUNIA",
"x_transferred"
],
"url": "http://secunia.com/advisories/48299"
},
{
"name": "IV09198",
"tags": [
"vendor-advisory",
"x_refsource_AIXAPAR",
"x_transferred"
],
"url": "http://www-01.ibm.com/support/docview.wss?uid=swg1IV09198"
},
{
"name": "48305",
"tags": [
"third-party-advisory",
"x_refsource_SECUNIA",
"x_transferred"
],
"url": "http://secunia.com/advisories/48305"
},
{
"name": "52333",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/52333"
},
{
"name": "mam-sclc-xss(72612)",
"tags": [
"vdb-entry",
"x_refsource_XF",
"x_transferred"
],
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/72612"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2012-02-14T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Cross-site scripting (XSS) vulnerability in the Start Center Layout and Configuration component in IBM Maximo Asset Management and Asset Management Essentials 6.2, 7.1, and 7.5; IBM Tivoli Asset Management for IT 6.2, 7.1, and 7.2; IBM Tivoli Service Request Manager 7.1 and 7.2; IBM Maximo Service Desk 6.2; and IBM Tivoli Change and Configuration Management Database (CCMDB) 6.2, 7.1, and 7.2 allows remote attackers to inject arbitrary web script or HTML via the display name."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-01-09T17:57:01.000Z",
"orgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
"shortName": "ibm"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.ibm.com/support/docview.wss?uid=swg21584666"
},
{
"name": "48299",
"tags": [
"third-party-advisory",
"x_refsource_SECUNIA"
],
"url": "http://secunia.com/advisories/48299"
},
{
"name": "IV09198",
"tags": [
"vendor-advisory",
"x_refsource_AIXAPAR"
],
"url": "http://www-01.ibm.com/support/docview.wss?uid=swg1IV09198"
},
{
"name": "48305",
"tags": [
"third-party-advisory",
"x_refsource_SECUNIA"
],
"url": "http://secunia.com/advisories/48305"
},
{
"name": "52333",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/52333"
},
{
"name": "mam-sclc-xss(72612)",
"tags": [
"vdb-entry",
"x_refsource_XF"
],
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/72612"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "psirt@us.ibm.com",
"ID": "CVE-2012-0195",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Cross-site scripting (XSS) vulnerability in the Start Center Layout and Configuration component in IBM Maximo Asset Management and Asset Management Essentials 6.2, 7.1, and 7.5; IBM Tivoli Asset Management for IT 6.2, 7.1, and 7.2; IBM Tivoli Service Request Manager 7.1 and 7.2; IBM Maximo Service Desk 6.2; and IBM Tivoli Change and Configuration Management Database (CCMDB) 6.2, 7.1, and 7.2 allows remote attackers to inject arbitrary web script or HTML via the display name."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://www.ibm.com/support/docview.wss?uid=swg21584666",
"refsource": "CONFIRM",
"url": "http://www.ibm.com/support/docview.wss?uid=swg21584666"
},
{
"name": "48299",
"refsource": "SECUNIA",
"url": "http://secunia.com/advisories/48299"
},
{
"name": "IV09198",
"refsource": "AIXAPAR",
"url": "http://www-01.ibm.com/support/docview.wss?uid=swg1IV09198"
},
{
"name": "48305",
"refsource": "SECUNIA",
"url": "http://secunia.com/advisories/48305"
},
{
"name": "52333",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/52333"
},
{
"name": "mam-sclc-xss(72612)",
"refsource": "XF",
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/72612"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
"assignerShortName": "ibm",
"cveId": "CVE-2012-0195",
"datePublished": "2012-03-13T01:00:00.000Z",
"dateReserved": "2011-12-14T00:00:00.000Z",
"dateUpdated": "2024-08-06T18:16:19.457Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2012-0195",
"date": "2026-07-02",
"epss": "0.01951",
"percentile": "0.77795"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2012-0195\",\"sourceIdentifier\":\"psirt@us.ibm.com\",\"published\":\"2012-03-13T03:12:26.197\",\"lastModified\":\"2026-04-29T01:13:23.040\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Cross-site scripting (XSS) vulnerability in the Start Center Layout and Configuration component in IBM Maximo Asset Management and Asset Management Essentials 6.2, 7.1, and 7.5; IBM Tivoli Asset Management for IT 6.2, 7.1, and 7.2; IBM Tivoli Service Request Manager 7.1 and 7.2; IBM Maximo Service Desk 6.2; and IBM Tivoli Change and Configuration Management Database (CCMDB) 6.2, 7.1, and 7.2 allows remote attackers to inject arbitrary web script or HTML via the display name.\"},{\"lang\":\"es\",\"value\":\"Vulnerabilidad de secuencias de comandos en sitios cruzados (XSS) el componente \\\"Start Center Layout and Configuration\\\" de IBM Maximo Asset Management y Asset Management Essentials 6.2, 7.1, t 7.5; IBM Tivoli Asset Management para IT 6.2, 7.1, y 7.2; IBM Tivoli Service Request Manager 7.1 y 7.2; IBM Maximo Service Desk 6.2; y IBM Tivoli Change y Configuration Management Database (CCMDB) 6.2, 7.1, y 7.2. Permite a usuarios remotos inyectar codigo de script web o c\u00f3digo HTML de su elecci\u00f3n a trav\u00e9s del \\\"display name\\\".\"}],\"metrics\":{\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:N/I:P/A:N\",\"baseScore\":4.3,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-79\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:ibm:maximo_asset_management:6.2:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F540E9A3-A1D7-4993-9149-295970944355\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:ibm:maximo_asset_management:7.1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DE721CF9-0F75-410B-A0F4-542041E25925\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:ibm:maximo_asset_management:7.5:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1AEBAE48-FFD0-4837-AB3B-F6C31B1AC8D9\"}]}]},{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:ibm:maximo_asset_management_essentials:6.2:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"233B2CD5-98F7-4024-BC1E-38BC4D8BA6F6\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:ibm:maximo_asset_management_essentials:7.1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"85457F6C-80FE-4E9F-BAB6-58B0485D8B7B\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:ibm:maximo_asset_management_essentials:7.5:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"598EAB6C-7D41-46FE-BB32-D31014CA01D6\"}]}]},{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:ibm:tivoli_asset_management_for_it:6.2:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"46711969-54C1-414A-B9F7-CCDCC4FFDA6A\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:ibm:tivoli_asset_management_for_it:7.1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"013D299A-6A9C-44C7-B49C-A4115F4C13E3\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:ibm:tivoli_asset_management_for_it:7.2:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"3D5C1BCF-1DC0-45E7-B624-9221F8610346\"}]}]},{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:ibm:trivoli_service_request_manager:7.1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5878EF6C-4C54-4BFB-A58A-DBBB96664E8F\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:ibm:trivoli_service_request_manager:7.2:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"68FF0043-7A28-4ECB-9888-6FB057A766B5\"}]}]},{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:ibm:maximo_service_desk:6.2:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B1D9DD16-F7C9-42E3-9E1D-36B4764C8503\"}]}]},{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:ibm:tivoli_change_and_configuration_management_database:6.2:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"33DD3C44-B7B9-4FFF-8445-7C2C084F7DCC\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:ibm:tivoli_change_and_configuration_management_database:7.1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4D4D3BE7-A7F0-431D-BB07-28DC94E8590F\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:ibm:tivoli_change_and_configuration_management_database:7.2:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1A53DB8A-5966-4D70-A254-C098DB12B0B3\"}]}]}],\"references\":[{\"url\":\"http://secunia.com/advisories/48299\",\"source\":\"psirt@us.ibm.com\"},{\"url\":\"http://secunia.com/advisories/48305\",\"source\":\"psirt@us.ibm.com\"},{\"url\":\"http://www-01.ibm.com/support/docview.wss?uid=swg1IV09198\",\"source\":\"psirt@us.ibm.com\"},{\"url\":\"http://www.ibm.com/support/docview.wss?uid=swg21584666\",\"source\":\"psirt@us.ibm.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"http://www.securityfocus.com/bid/52333\",\"source\":\"psirt@us.ibm.com\"},{\"url\":\"https://exchange.xforce.ibmcloud.com/vulnerabilities/72612\",\"source\":\"psirt@us.ibm.com\"},{\"url\":\"http://secunia.com/advisories/48299\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"http://secunia.com/advisories/48305\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"http://www-01.ibm.com/support/docview.wss?uid=swg1IV09198\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"http://www.ibm.com/support/docview.wss?uid=swg21584666\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"http://www.securityfocus.com/bid/52333\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"https://exchange.xforce.ibmcloud.com/vulnerabilities/72612\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"}]}}"
}
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…