Action not permitted
Modal body text goes here.
Modal Title
Modal Body
CVE-2011-4033 (GCVE-0-2011-4033)
Vulnerability from cvelistv5 – Published: 2011-12-02 11:00 – Updated: 2024-09-17 00:31- n/a
| URL | Tags |
|---|---|
| http://www.scada.schneider-electric.com/sites/sca… | x_refsource_CONFIRM |
| http://www.us-cert.gov/control_systems/pdf/ICSA-1… | x_refsource_MISC |
| http://www.citect.com/index.php?option=com_conten… | x_refsource_CONFIRM |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T23:53:32.616Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.scada.schneider-electric.com/sites/scada/en/login/historian-vulnerability.page"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-307-01.pdf"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.citect.com/index.php?option=com_content\u0026view=article\u0026id=1656\u0026Itemid=1695"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Buffer overflow in the Steema TeeChart ActiveX control, as used in Schneider Electric Vijeo Historian 4.30 and earlier, CitectHistorian 4.30 and earlier, and CitectSCADAReports 4.10 and earlier, allows remote attackers to cause a denial of service via unspecified vectors."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2011-12-02T11:00:00.000Z",
"orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"shortName": "certcc"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.scada.schneider-electric.com/sites/scada/en/login/historian-vulnerability.page"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-307-01.pdf"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.citect.com/index.php?option=com_content\u0026view=article\u0026id=1656\u0026Itemid=1695"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cert@cert.org",
"ID": "CVE-2011-4033",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Buffer overflow in the Steema TeeChart ActiveX control, as used in Schneider Electric Vijeo Historian 4.30 and earlier, CitectHistorian 4.30 and earlier, and CitectSCADAReports 4.10 and earlier, allows remote attackers to cause a denial of service via unspecified vectors."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://www.scada.schneider-electric.com/sites/scada/en/login/historian-vulnerability.page",
"refsource": "CONFIRM",
"url": "http://www.scada.schneider-electric.com/sites/scada/en/login/historian-vulnerability.page"
},
{
"name": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-307-01.pdf",
"refsource": "MISC",
"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-307-01.pdf"
},
{
"name": "http://www.citect.com/index.php?option=com_content\u0026view=article\u0026id=1656\u0026Itemid=1695",
"refsource": "CONFIRM",
"url": "http://www.citect.com/index.php?option=com_content\u0026view=article\u0026id=1656\u0026Itemid=1695"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"assignerShortName": "certcc",
"cveId": "CVE-2011-4033",
"datePublished": "2011-12-02T11:00:00.000Z",
"dateReserved": "2011-10-13T00:00:00.000Z",
"dateUpdated": "2024-09-17T00:31:42.117Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2011-4033",
"date": "2026-07-01",
"epss": "0.01684",
"percentile": "0.74166"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2011-4033\",\"sourceIdentifier\":\"cret@cert.org\",\"published\":\"2011-12-02T11:55:05.090\",\"lastModified\":\"2026-04-29T01:13:23.040\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Buffer overflow in the Steema TeeChart ActiveX control, as used in Schneider Electric Vijeo Historian 4.30 and earlier, CitectHistorian 4.30 and earlier, and CitectSCADAReports 4.10 and earlier, allows remote attackers to cause a denial of service via unspecified vectors.\"},{\"lang\":\"es\",\"value\":\"Desbordamiento de b\u00fafer en el control ActiveX TeeChart Steema, tal como se utiliza en Schneider Electric Vijeo Historian v4.30 y anteriores, CitectHistorian v4.30 y anteriores, y CitectSCADAReports v4.10 y anteriores, permite a atacantes remotos provocar una denegaci\u00f3n de servicio a trav\u00e9s de vectores no especificados.\"}],\"metrics\":{\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:N/I:N/A:P\",\"baseScore\":4.3,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-119\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:vijeo_historian:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"4.30\",\"matchCriteriaId\":\"FA173AD2-52AF-4401-9A29-757B68168B4D\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:vijeo_historian:4.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"00E3E11B-E433-4D89-9525-8159CEC30DC0\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:vijeo_historian:4.10:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2788D1E5-206A-4AC8-AA28-65E5EE268B59\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:vijeo_historian:4.20:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"99B88BED-7F2F-4F89-9BD1-B7EDC1608531\"}]}]},{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:citecthistorian:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"4.30\",\"matchCriteriaId\":\"859A64AD-1FB2-4A7C-AE4D-26951FC050F9\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:citecthistorian:4.20:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B491E331-B533-4E09-966E-45A3BE724C5A\"}]}]},{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:citectscada_reports:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"4.10\",\"matchCriteriaId\":\"106C6198-C341-4B10-8788-A8FA51F137F1\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:citectscada_reports:4.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"38765B0B-9C09-4BC0-9E50-D0C6E8969A77\"}]}]}],\"references\":[{\"url\":\"http://www.citect.com/index.php?option=com_content\u0026view=article\u0026id=1656\u0026Itemid=1695\",\"source\":\"cret@cert.org\"},{\"url\":\"http://www.scada.schneider-electric.com/sites/scada/en/login/historian-vulnerability.page\",\"source\":\"cret@cert.org\"},{\"url\":\"http://www.us-cert.gov/control_systems/pdf/ICSA-11-307-01.pdf\",\"source\":\"cret@cert.org\",\"tags\":[\"US Government Resource\"]},{\"url\":\"http://www.citect.com/index.php?option=com_content\u0026view=article\u0026id=1656\u0026Itemid=1695\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"http://www.scada.schneider-electric.com/sites/scada/en/login/historian-vulnerability.page\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"http://www.us-cert.gov/control_systems/pdf/ICSA-11-307-01.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"US Government Resource\"]}]}}"
}
}
FKIE_CVE-2011-4033
Vulnerability from fkie_nvd - Published: 2011-12-02 11:55 - Updated: 2026-06-16 23:34{
"affected": [
{
"affectedData": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"source": "cret@cert.org"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:schneider-electric:vijeo_historian:*:*:*:*:*:*:*:*",
"matchCriteriaId": "FA173AD2-52AF-4401-9A29-757B68168B4D",
"versionEndIncluding": "4.30",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:schneider-electric:vijeo_historian:4.0:*:*:*:*:*:*:*",
"matchCriteriaId": "00E3E11B-E433-4D89-9525-8159CEC30DC0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:schneider-electric:vijeo_historian:4.10:*:*:*:*:*:*:*",
"matchCriteriaId": "2788D1E5-206A-4AC8-AA28-65E5EE268B59",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:schneider-electric:vijeo_historian:4.20:*:*:*:*:*:*:*",
"matchCriteriaId": "99B88BED-7F2F-4F89-9BD1-B7EDC1608531",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:schneider-electric:citecthistorian:*:*:*:*:*:*:*:*",
"matchCriteriaId": "859A64AD-1FB2-4A7C-AE4D-26951FC050F9",
"versionEndIncluding": "4.30",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:schneider-electric:citecthistorian:4.20:*:*:*:*:*:*:*",
"matchCriteriaId": "B491E331-B533-4E09-966E-45A3BE724C5A",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:schneider-electric:citectscada_reports:*:*:*:*:*:*:*:*",
"matchCriteriaId": "106C6198-C341-4B10-8788-A8FA51F137F1",
"versionEndIncluding": "4.10",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:schneider-electric:citectscada_reports:4.0:*:*:*:*:*:*:*",
"matchCriteriaId": "38765B0B-9C09-4BC0-9E50-D0C6E8969A77",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Buffer overflow in the Steema TeeChart ActiveX control, as used in Schneider Electric Vijeo Historian 4.30 and earlier, CitectHistorian 4.30 and earlier, and CitectSCADAReports 4.10 and earlier, allows remote attackers to cause a denial of service via unspecified vectors."
},
{
"lang": "es",
"value": "Desbordamiento de b\u00fafer en el control ActiveX TeeChart Steema, tal como se utiliza en Schneider Electric Vijeo Historian v4.30 y anteriores, CitectHistorian v4.30 y anteriores, y CitectSCADAReports v4.10 y anteriores, permite a atacantes remotos provocar una denegaci\u00f3n de servicio a trav\u00e9s de vectores no especificados."
}
],
"id": "CVE-2011-4033",
"lastModified": "2026-06-16T23:34:19.183",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 4.3,
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:M/Au:N/C:N/I:N/A:P",
"version": "2.0"
},
"exploitabilityScore": 8.6,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": true
}
]
},
"published": "2011-12-02T11:55:05.090",
"references": [
{
"source": "cret@cert.org",
"url": "http://www.citect.com/index.php?option=com_content\u0026view=article\u0026id=1656\u0026Itemid=1695"
},
{
"source": "cret@cert.org",
"url": "http://www.scada.schneider-electric.com/sites/scada/en/login/historian-vulnerability.page"
},
{
"source": "cret@cert.org",
"tags": [
"US Government Resource"
],
"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-307-01.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "http://www.citect.com/index.php?option=com_content\u0026view=article\u0026id=1656\u0026Itemid=1695"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "http://www.scada.schneider-electric.com/sites/scada/en/login/historian-vulnerability.page"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"US Government Resource"
],
"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-307-01.pdf"
}
],
"sourceIdentifier": "cret@cert.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-119"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
GHSA-G897-V7RW-6GVC
Vulnerability from github – Published: 2022-05-17 05:36 – Updated: 2022-05-17 05:36Buffer overflow in the Steema TeeChart ActiveX control, as used in Schneider Electric Vijeo Historian 4.30 and earlier, CitectHistorian 4.30 and earlier, and CitectSCADAReports 4.10 and earlier, allows remote attackers to cause a denial of service via unspecified vectors.
{
"affected": [],
"aliases": [
"CVE-2011-4033"
],
"database_specific": {
"cwe_ids": [
"CWE-119"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2011-12-02T11:55:00Z",
"severity": "MODERATE"
},
"details": "Buffer overflow in the Steema TeeChart ActiveX control, as used in Schneider Electric Vijeo Historian 4.30 and earlier, CitectHistorian 4.30 and earlier, and CitectSCADAReports 4.10 and earlier, allows remote attackers to cause a denial of service via unspecified vectors.",
"id": "GHSA-g897-v7rw-6gvc",
"modified": "2022-05-17T05:36:26Z",
"published": "2022-05-17T05:36:26Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2011-4033"
},
{
"type": "WEB",
"url": "http://www.citect.com/index.php?option=com_content\u0026view=article\u0026id=1656\u0026Itemid=1695"
},
{
"type": "WEB",
"url": "http://www.scada.schneider-electric.com/sites/scada/en/login/historian-vulnerability.page"
},
{
"type": "WEB",
"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-307-01.pdf"
}
],
"schema_version": "1.4.0",
"severity": []
}
GSD-2011-4033
Vulnerability from gsd - Updated: 2023-12-13 01:19{
"GSD": {
"alias": "CVE-2011-4033",
"description": "Buffer overflow in the Steema TeeChart ActiveX control, as used in Schneider Electric Vijeo Historian 4.30 and earlier, CitectHistorian 4.30 and earlier, and CitectSCADAReports 4.10 and earlier, allows remote attackers to cause a denial of service via unspecified vectors.",
"id": "GSD-2011-4033"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2011-4033"
],
"details": "Buffer overflow in the Steema TeeChart ActiveX control, as used in Schneider Electric Vijeo Historian 4.30 and earlier, CitectHistorian 4.30 and earlier, and CitectSCADAReports 4.10 and earlier, allows remote attackers to cause a denial of service via unspecified vectors.",
"id": "GSD-2011-4033",
"modified": "2023-12-13T01:19:05.816855Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "cert@cert.org",
"ID": "CVE-2011-4033",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Buffer overflow in the Steema TeeChart ActiveX control, as used in Schneider Electric Vijeo Historian 4.30 and earlier, CitectHistorian 4.30 and earlier, and CitectSCADAReports 4.10 and earlier, allows remote attackers to cause a denial of service via unspecified vectors."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://www.scada.schneider-electric.com/sites/scada/en/login/historian-vulnerability.page",
"refsource": "CONFIRM",
"url": "http://www.scada.schneider-electric.com/sites/scada/en/login/historian-vulnerability.page"
},
{
"name": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-307-01.pdf",
"refsource": "MISC",
"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-307-01.pdf"
},
{
"name": "http://www.citect.com/index.php?option=com_content\u0026view=article\u0026id=1656\u0026Itemid=1695",
"refsource": "CONFIRM",
"url": "http://www.citect.com/index.php?option=com_content\u0026view=article\u0026id=1656\u0026Itemid=1695"
}
]
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:vijeo_historian:4.20:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:vijeo_historian:4.10:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:vijeo_historian:4.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:vijeo_historian:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "4.30",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:citecthistorian:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "4.30",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:citecthistorian:4.20:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:citectscada_reports:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "4.10",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:citectscada_reports:4.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "cert@cert.org",
"ID": "CVE-2011-4033"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "Buffer overflow in the Steema TeeChart ActiveX control, as used in Schneider Electric Vijeo Historian 4.30 and earlier, CitectHistorian 4.30 and earlier, and CitectSCADAReports 4.10 and earlier, allows remote attackers to cause a denial of service via unspecified vectors."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-119"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://www.scada.schneider-electric.com/sites/scada/en/login/historian-vulnerability.page",
"refsource": "CONFIRM",
"tags": [],
"url": "http://www.scada.schneider-electric.com/sites/scada/en/login/historian-vulnerability.page"
},
{
"name": "http://www.citect.com/index.php?option=com_content\u0026view=article\u0026id=1656\u0026Itemid=1695",
"refsource": "CONFIRM",
"tags": [],
"url": "http://www.citect.com/index.php?option=com_content\u0026view=article\u0026id=1656\u0026Itemid=1695"
},
{
"name": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-307-01.pdf",
"refsource": "MISC",
"tags": [
"US Government Resource"
],
"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-307-01.pdf"
}
]
}
},
"impact": {
"baseMetricV2": {
"cvssV2": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 4.3,
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:M/Au:N/C:N/I:N/A:P",
"version": "2.0"
},
"exploitabilityScore": 8.6,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"userInteractionRequired": true
}
},
"lastModifiedDate": "2011-12-02T11:55Z",
"publishedDate": "2011-12-02T11:55Z"
}
}
}
ICSA-11-307-01
Vulnerability from csaf_cisa - Published: 2011-08-06 06:00 - Updated: 2025-06-09 19:52| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Schneider Electric Vijeo Historian: <=V4.30
Schneider Electric / Vijeo Historian
|
<=V4.30 |
Mitigation
fix
Mitigation
fix
|
|
|
Schneider Electric CitectHistorian: <=V4.30
Schneider Electric / CitectHistorian
|
<=V4.30 |
Mitigation
fix
Mitigation
fix
|
|
|
Schneider Electric CitectSCADA Reports: <=V4.10
Schneider Electric / CitectSCADA Reports
|
<=V4.10 |
Mitigation
fix
Mitigation
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Schneider Electric Vijeo Historian: <=V4.30
Schneider Electric / Vijeo Historian
|
<=V4.30 |
Mitigation
fix
Mitigation
fix
|
|
|
Schneider Electric CitectHistorian: <=V4.30
Schneider Electric / CitectHistorian
|
<=V4.30 |
Mitigation
fix
Mitigation
fix
|
|
|
Schneider Electric CitectSCADA Reports: <=V4.10
Schneider Electric / CitectSCADA Reports
|
<=V4.10 |
Mitigation
fix
Mitigation
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Schneider Electric Vijeo Historian: <=V4.30
Schneider Electric / Vijeo Historian
|
<=V4.30 |
Mitigation
fix
Mitigation
fix
|
|
|
Schneider Electric CitectHistorian: <=V4.30
Schneider Electric / CitectHistorian
|
<=V4.30 |
Mitigation
fix
Mitigation
fix
|
|
|
Schneider Electric CitectSCADA Reports: <=V4.10
Schneider Electric / CitectSCADA Reports
|
<=V4.10 |
Mitigation
fix
Mitigation
fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Schneider Electric Vijeo Historian: <=V4.30
Schneider Electric / Vijeo Historian
|
<=V4.30 |
Mitigation
fix
Mitigation
fix
|
|
|
Schneider Electric CitectHistorian: <=V4.30
Schneider Electric / CitectHistorian
|
<=V4.30 |
Mitigation
fix
Mitigation
fix
|
|
|
Schneider Electric CitectSCADA Reports: <=V4.10
Schneider Electric / CitectSCADA Reports
|
<=V4.10 |
Mitigation
fix
Mitigation
fix
|
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"lang": "en-US",
"notes": [
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "general",
"text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov",
"title": "CISA Disclaimer"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the risk of exploitation.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Locate control system networks and remote devices behind firewalls and isolating them from business networks.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.",
"title": "Recommended Practices"
}
],
"publisher": {
"category": "coordinator",
"contact_details": "central@cisa.dhs.gov",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "ICS Advisory ICSA-11-307-01 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2011/icsa-11-307-01.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-11-307-01 - Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-11-307-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/topics/industrial-control-systems"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/sites/default/files/publications/emailscams0905.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ncas/tips/ST04-014"
}
],
"title": "Schneider Electric Vijeo Historian Web Server Multiple Vulnerabilities",
"tracking": {
"current_release_date": "2025-06-09T19:52:15.424002Z",
"generator": {
"date": "2025-06-09T19:52:15.423885Z",
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-11-307-01",
"initial_release_date": "2011-08-06T06:00:00.000000Z",
"revision_history": [
{
"date": "2011-08-06T06:00:00.000000Z",
"legacy_version": "Initial",
"number": "1",
"summary": "Initial Publication"
},
{
"date": "2025-06-09T19:52:15.424002Z",
"legacy_version": "CSAF Conversion",
"number": "2",
"summary": "Advisory converted into a CSAF"
}
],
"status": "final",
"version": "2"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c=V4.30",
"product": {
"name": "Schneider Electric Vijeo Historian: \u003c=V4.30",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "Vijeo Historian"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c=V4.30",
"product": {
"name": "Schneider Electric CitectHistorian: \u003c=V4.30",
"product_id": "CSAFPID-0002"
}
}
],
"category": "product_name",
"name": "CitectHistorian"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c=V4.10",
"product": {
"name": "Schneider Electric CitectSCADA Reports: \u003c=V4.10",
"product_id": "CSAFPID-0003"
}
}
],
"category": "product_name",
"name": "CitectSCADA Reports"
}
],
"category": "vendor",
"name": "Schneider Electric"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2011-4033",
"cwe": {
"id": "CWE-119",
"name": "Improper Restriction of Operations within the Bounds of a Memory Buffer"
},
"notes": [
{
"category": "summary",
"text": "Buffer overflow in the Steema TeeChart ActiveX control, as used in Schneider Electric Vijeo Historian 4.30 and earlier, CitectHistorian 4.30 and earlier, and CitectSCADAReports 4.10 and earlier, allows remote attackers to cause a denial of service via unspecified vectors.",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Schneider Electric has created a patch and has issued a customer notification describing the vulnerabilities. (http://www.scada.schneider-electric.com/sites/scada/en/login/historian-vulnerability.page).",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "http://www.scada.schneider-electric.com/sites/scada/en/login/historian-vulnerability.page"
},
{
"category": "mitigation",
"details": "Schneider Electric recommends that all customers using the above mentioned software packages download and apply the patch located at (http://www.citect.com/index.php?option=com_content\u0026view=article\u0026id=1656\u0026Itemid=1695)",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "http://www.citect.com/index.php?option=com_content\u0026view=article\u0026id=1656\u0026Itemid=1695"
}
],
"scores": [
{
"cvss_v2": {
"baseScore": 4.3,
"vectorString": "AV:N/AC:M/Au:N/C:N/I:N/A:P",
"version": "2.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
},
{
"cve": "CVE-2011-4034",
"cwe": {
"id": "CWE-119",
"name": "Improper Restriction of Operations within the Bounds of a Memory Buffer"
},
"notes": [
{
"category": "summary",
"text": "Buffer overflow in the Steema TeeChart ActiveX control, as used in Schneider Electric Vijeo Historian 4.30 and earlier, CitectHistorian 4.30 and earlier, and CitectSCADAReports 4.10 and earlier, allows remote attackers to execute arbitrary code or cause a denial of service via unspecified vectors.",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Schneider Electric has created a patch and has issued a customer notification describing the vulnerabilities. (http://www.scada.schneider-electric.com/sites/scada/en/login/historian-vulnerability.page).",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "http://www.scada.schneider-electric.com/sites/scada/en/login/historian-vulnerability.page"
},
{
"category": "mitigation",
"details": "Schneider Electric recommends that all customers using the above mentioned software packages download and apply the patch located at (http://www.citect.com/index.php?option=com_content\u0026view=article\u0026id=1656\u0026Itemid=1695)",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "http://www.citect.com/index.php?option=com_content\u0026view=article\u0026id=1656\u0026Itemid=1695"
}
],
"scores": [
{
"cvss_v2": {
"baseScore": 9.3,
"vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
},
{
"cve": "CVE-2011-4035",
"cwe": {
"id": "CWE-79",
"name": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)"
},
"notes": [
{
"category": "summary",
"text": "Cross-site scripting (XSS) vulnerability in Schneider Electric Vijeo Historian 4.30 and earlier, CitectHistorian 4.30 and earlier, and CitectSCADAReports 4.10 and earlier allows remote attackers to inject arbitrary web script or HTML via unspecified vectors.",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Schneider Electric has created a patch and has issued a customer notification describing the vulnerabilities. (http://www.scada.schneider-electric.com/sites/scada/en/login/historian-vulnerability.page).",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "http://www.scada.schneider-electric.com/sites/scada/en/login/historian-vulnerability.page"
},
{
"category": "mitigation",
"details": "Schneider Electric recommends that all customers using the above mentioned software packages download and apply the patch located at (http://www.citect.com/index.php?option=com_content\u0026view=article\u0026id=1656\u0026Itemid=1695)",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "http://www.citect.com/index.php?option=com_content\u0026view=article\u0026id=1656\u0026Itemid=1695"
}
],
"scores": [
{
"cvss_v2": {
"baseScore": 4.3,
"vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
"version": "2.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
},
{
"cve": "CVE-2011-4036",
"cwe": {
"id": "CWE-22",
"name": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)"
},
"notes": [
{
"category": "summary",
"text": "Directory traversal vulnerability in Schneider Electric Vijeo Historian 4.30 and earlier, CitectHistorian 4.30 and earlier, and CitectSCADAReports 4.10 and earlier allows remote attackers to read arbitrary files via unspecified vectors.",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Schneider Electric has created a patch and has issued a customer notification describing the vulnerabilities. (http://www.scada.schneider-electric.com/sites/scada/en/login/historian-vulnerability.page).",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "http://www.scada.schneider-electric.com/sites/scada/en/login/historian-vulnerability.page"
},
{
"category": "mitigation",
"details": "Schneider Electric recommends that all customers using the above mentioned software packages download and apply the patch located at (http://www.citect.com/index.php?option=com_content\u0026view=article\u0026id=1656\u0026Itemid=1695)",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
],
"url": "http://www.citect.com/index.php?option=com_content\u0026view=article\u0026id=1656\u0026Itemid=1695"
}
],
"scores": [
{
"cvss_v2": {
"baseScore": 5.0,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
}
]
}
VAR-201112-0156
Vulnerability from variot - Updated: 2025-04-11 23:02Buffer overflow in the Steema TeeChart ActiveX control, as used in Schneider Electric Vijeo Historian 4.30 and earlier, CitectHistorian 4.30 and earlier, and CitectSCADAReports 4.10 and earlier, allows remote attackers to cause a denial of service via unspecified vectors. TeeChart Pro ActiveX is a full-featured graphical charting tool for business, science, engineering and statistics. TeeChart ActiveX control is prone to a remote denial-of-service vulnerability because of a buffer-overflow error. Attackers can exploit this issue to crash an application using the vulnerable control, which causes a denial-of-service condition. Due to the nature of this issue, arbitrary code-execution may be possible; however this has not been confirmed. ----------------------------------------------------------------------
Secunia is hiring!
Find your next job here:
http://secunia.com/company/jobs/
TITLE: Schneider Electric Products Multiple Vulnerabilities
SECUNIA ADVISORY ID: SA47046
VERIFY ADVISORY: Secunia.com http://secunia.com/advisories/47046/ Customer Area (Credentials Required) https://ca.secunia.com/?page=viewadvisory&vuln_id=47046
RELEASE DATE: 2011-11-29
DISCUSS ADVISORY: http://secunia.com/advisories/47046/#comments
AVAILABLE ON SITE AND IN CUSTOMER AREA: * Last Update * Popularity * Comments * Criticality Level * Impact * Where * Solution Status * Operating System / Software * CVE Reference(s)
http://secunia.com/advisories/47046/
ONLY AVAILABLE IN CUSTOMER AREA: * Authentication Level * Report Reliability * Secunia PoC * Secunia Analysis * Systems Affected * Approve Distribution * Remediation Status * Secunia CVSS Score * CVSS
https://ca.secunia.com/?page=viewadvisory&vuln_id=47046
ONLY AVAILABLE WITH SECUNIA CSI AND SECUNIA PSI: * AUTOMATED SCANNING
http://secunia.com/vulnerability_scanning/personal/ http://secunia.com/vulnerability_scanning/corporate/wsus_sccm_3rd_third_party_patching/
DESCRIPTION: Multiple vulnerabilities have been reported in multiple Schneider Electric products, which can be exploited by malicious people to conduct cross-site scripting attacks, disclose potentially sensitive information, and compromise a user's system. No further information is currently available.
Successful exploitation of this vulnerability may allow execution of arbitrary code.
2) Certain unspecified input is not properly sanitised before being returned to the user. This can be exploited to execute arbitrary HTML and script code in a user's browser session in context of an affected site.
3) Certain unspecified input passed to the web portal is not properly verified before being used to read files and can be exploited to disclose arbitrary files via directory traversal attacks.
The vulnerabilities are reported in the following products: * Vijeo Historian version 4.30 and prior. * CitectHistorian version 4.30 and prior. * CitectSCADA Reports version 4.10 and prior.
SOLUTION: Apply patches (please see the vendor's advisory for details).
PROVIDED AND/OR DISCOVERED BY: The vendor credits Kuang-Chun Hung, Security Research and Service Institute Information and Communication Security Technology Center (ICST) via ICS-CERT.
ORIGINAL ADVISORY: Schneider Electric: http://www.citect.com/index.php?option=com_content&view=article&id=1656&Itemid=1695
ICS-CERT: http://www.us-cert.gov/control_systems/pdf/ICSA-11-307-01.pdf
OTHER REFERENCES: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
DEEP LINKS: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
EXTENDED DESCRIPTION: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
EXTENDED SOLUTION: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
EXPLOIT: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
About: This Advisory was delivered by Secunia as a free service to help private users keeping their systems up to date against the latest vulnerabilities.
Subscribe: http://secunia.com/advisories/secunia_security_advisories/
Definitions: (Criticality, Where etc.) http://secunia.com/advisories/about_secunia_advisories/
Please Note: Secunia recommends that you verify all advisories you receive by clicking the link. Secunia NEVER sends attached files with advisories. Secunia does not advise people to install third party patches, only use those supplied by the vendor.
Unsubscribe: Secunia Security Advisories http://secunia.com/sec_adv_unsubscribe/?email=packet%40packetstormsecurity.org
Show details on source website
{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201112-0156",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "citecthistorian",
"scope": "lte",
"trust": 1.8,
"vendor": "schneider electric",
"version": "4.30"
},
{
"model": "citectscada reports",
"scope": "lte",
"trust": 1.8,
"vendor": "schneider electric",
"version": "4.10"
},
{
"model": "vijeo historian",
"scope": "lte",
"trust": 1.8,
"vendor": "schneider electric",
"version": "4.30"
},
{
"model": "vijeo historian",
"scope": "eq",
"trust": 1.6,
"vendor": "schneider electric",
"version": "4.0"
},
{
"model": "citectscada reports",
"scope": "eq",
"trust": 1.6,
"vendor": "schneider electric",
"version": "4.0"
},
{
"model": "vijeo historian",
"scope": "eq",
"trust": 1.6,
"vendor": "schneider electric",
"version": "4.20"
},
{
"model": "vijeo historian",
"scope": "eq",
"trust": 1.6,
"vendor": "schneider electric",
"version": "4.10"
},
{
"model": "citecthistorian",
"scope": "eq",
"trust": 1.6,
"vendor": "schneider electric",
"version": "4.20"
},
{
"model": "electric vijeo historian",
"scope": "eq",
"trust": 0.9,
"vendor": "schneider",
"version": "4.10"
},
{
"model": "electric vijeo historian",
"scope": "eq",
"trust": 0.9,
"vendor": "schneider",
"version": "4.20"
},
{
"model": "electric vijeo historian",
"scope": "eq",
"trust": 0.9,
"vendor": "schneider",
"version": "4.30"
},
{
"model": "electric citectscada reports",
"scope": "eq",
"trust": 0.9,
"vendor": "schneider",
"version": "4.10"
},
{
"model": "electric citect historian",
"scope": "eq",
"trust": 0.9,
"vendor": "schneider",
"version": "4.20"
},
{
"model": "electric citect historian",
"scope": "eq",
"trust": 0.9,
"vendor": "schneider",
"version": "4.30"
},
{
"model": "software teechart activex control",
"scope": null,
"trust": 0.6,
"vendor": "steema",
"version": null
},
{
"model": "vijeo historian",
"scope": "eq",
"trust": 0.6,
"vendor": "schneider electric",
"version": "4.30"
},
{
"model": "citectscada reports",
"scope": "eq",
"trust": 0.6,
"vendor": "schneider electric",
"version": "4.10"
},
{
"model": "citecthistorian",
"scope": "eq",
"trust": 0.6,
"vendor": "schneider electric",
"version": "4.30"
},
{
"model": "software teechart activex control",
"scope": "eq",
"trust": 0.3,
"vendor": "steema",
"version": "0"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "vijeo historian",
"version": "4.0"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "vijeo historian",
"version": "4.10"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "vijeo historian",
"version": "4.20"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "vijeo historian",
"version": "*"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "citecthistorian",
"version": "4.20"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "citecthistorian",
"version": "*"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "citectscada reports",
"version": "4.0"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "citectscada reports",
"version": "*"
}
],
"sources": [
{
"db": "IVD",
"id": "5a41c13e-2354-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2011-5098"
},
{
"db": "BID",
"id": "50835"
},
{
"db": "JVNDB",
"id": "JVNDB-2011-003182"
},
{
"db": "CNNVD",
"id": "CNNVD-201111-488"
},
{
"db": "NVD",
"id": "CVE-2011-4033"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"cpe_match": [
{
"cpe22Uri": "cpe:/a:schneider_electric:citecthistorian",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/a:schneider_electric:citectscada_reports",
"vulnerable": true
},
{
"cpe22Uri": "cpe:/a:schneider_electric:vijeo_historian",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2011-003182"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Kuang-Chun Hung",
"sources": [
{
"db": "BID",
"id": "50835"
},
{
"db": "CNNVD",
"id": "CNNVD-201111-488"
}
],
"trust": 0.9
},
"cve": "CVE-2011-4033",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "nvd@nist.gov",
"availabilityImpact": "PARTIAL",
"baseScore": 4.3,
"confidentialityImpact": "NONE",
"exploitabilityScore": 8.6,
"id": "CVE-2011-4033",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 1.8,
"vectorString": "AV:N/AC:M/Au:N/C:N/I:N/A:P",
"version": "2.0"
},
{
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "IVD",
"availabilityImpact": "PARTIAL",
"baseScore": 4.3,
"confidentialityImpact": "NONE",
"exploitabilityScore": 8.6,
"id": "5a41c13e-2354-11e6-abef-000c29c66e3d",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.2,
"vectorString": "AV:N/AC:M/Au:N/C:N/I:N/A:P",
"version": "2.9 [IVD]"
},
{
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "PARTIAL",
"baseScore": 4.3,
"confidentialityImpact": "NONE",
"exploitabilityScore": 8.6,
"id": "VHN-51978",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.1,
"vectorString": "AV:N/AC:M/AU:N/C:N/I:N/A:P",
"version": "2.0"
}
],
"cvssV3": [],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2011-4033",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "NVD",
"id": "CVE-2011-4033",
"trust": 0.8,
"value": "Medium"
},
{
"author": "CNNVD",
"id": "CNNVD-201111-488",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "IVD",
"id": "5a41c13e-2354-11e6-abef-000c29c66e3d",
"trust": 0.2,
"value": "MEDIUM"
},
{
"author": "VULHUB",
"id": "VHN-51978",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "IVD",
"id": "5a41c13e-2354-11e6-abef-000c29c66e3d"
},
{
"db": "VULHUB",
"id": "VHN-51978"
},
{
"db": "JVNDB",
"id": "JVNDB-2011-003182"
},
{
"db": "CNNVD",
"id": "CNNVD-201111-488"
},
{
"db": "NVD",
"id": "CVE-2011-4033"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Buffer overflow in the Steema TeeChart ActiveX control, as used in Schneider Electric Vijeo Historian 4.30 and earlier, CitectHistorian 4.30 and earlier, and CitectSCADAReports 4.10 and earlier, allows remote attackers to cause a denial of service via unspecified vectors. TeeChart Pro ActiveX is a full-featured graphical charting tool for business, science, engineering and statistics. TeeChart ActiveX control is prone to a remote denial-of-service vulnerability because of a buffer-overflow error. \nAttackers can exploit this issue to crash an application using the vulnerable control, which causes a denial-of-service condition. Due to the nature of this issue, arbitrary code-execution may be possible; however this has not been confirmed. ----------------------------------------------------------------------\n\nSecunia is hiring!\n\nFind your next job here:\n\nhttp://secunia.com/company/jobs/\n\n----------------------------------------------------------------------\n\nTITLE:\nSchneider Electric Products Multiple Vulnerabilities\n\nSECUNIA ADVISORY ID:\nSA47046\n\nVERIFY ADVISORY:\nSecunia.com\nhttp://secunia.com/advisories/47046/\nCustomer Area (Credentials Required)\nhttps://ca.secunia.com/?page=viewadvisory\u0026vuln_id=47046\n\nRELEASE DATE:\n2011-11-29\n\nDISCUSS ADVISORY:\nhttp://secunia.com/advisories/47046/#comments\n\nAVAILABLE ON SITE AND IN CUSTOMER AREA:\n * Last Update\n * Popularity\n * Comments\n * Criticality Level\n * Impact\n * Where\n * Solution Status\n * Operating System / Software\n * CVE Reference(s)\n\nhttp://secunia.com/advisories/47046/\n\nONLY AVAILABLE IN CUSTOMER AREA:\n * Authentication Level\n * Report Reliability\n * Secunia PoC\n * Secunia Analysis\n * Systems Affected\n * Approve Distribution\n * Remediation Status\n * Secunia CVSS Score\n * CVSS\n\nhttps://ca.secunia.com/?page=viewadvisory\u0026vuln_id=47046\n\nONLY AVAILABLE WITH SECUNIA CSI AND SECUNIA PSI:\n * AUTOMATED SCANNING\n\nhttp://secunia.com/vulnerability_scanning/personal/\nhttp://secunia.com/vulnerability_scanning/corporate/wsus_sccm_3rd_third_party_patching/\n\nDESCRIPTION:\nMultiple vulnerabilities have been reported in multiple Schneider\nElectric products, which can be exploited by malicious people to\nconduct cross-site scripting attacks, disclose potentially sensitive\ninformation, and compromise a user\u0027s system. No further information is currently\navailable. \n\nSuccessful exploitation of this vulnerability may allow execution of\narbitrary code. \n\n2) Certain unspecified input is not properly sanitised before being\nreturned to the user. This can be exploited to execute arbitrary HTML\nand script code in a user\u0027s browser session in context of an affected\nsite. \n\n3) Certain unspecified input passed to the web portal is not properly\nverified before being used to read files and can be exploited to\ndisclose arbitrary files via directory traversal attacks. \n\nThe vulnerabilities are reported in the following products:\n* Vijeo Historian version 4.30 and prior. \n* CitectHistorian version 4.30 and prior. \n* CitectSCADA Reports version 4.10 and prior. \n\nSOLUTION:\nApply patches (please see the vendor\u0027s advisory for details). \n\nPROVIDED AND/OR DISCOVERED BY:\nThe vendor credits Kuang-Chun Hung, Security Research and Service\nInstitute Information and Communication Security Technology Center\n(ICST) via ICS-CERT. \n\nORIGINAL ADVISORY:\nSchneider Electric:\nhttp://www.citect.com/index.php?option=com_content\u0026view=article\u0026id=1656\u0026Itemid=1695\n\nICS-CERT:\nhttp://www.us-cert.gov/control_systems/pdf/ICSA-11-307-01.pdf\n\nOTHER REFERENCES:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\nDEEP LINKS:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\nEXTENDED DESCRIPTION:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\nEXTENDED SOLUTION:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\nEXPLOIT:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\n----------------------------------------------------------------------\n\nAbout:\nThis Advisory was delivered by Secunia as a free service to help\nprivate users keeping their systems up to date against the latest\nvulnerabilities. \n\nSubscribe:\nhttp://secunia.com/advisories/secunia_security_advisories/\n\nDefinitions: (Criticality, Where etc.)\nhttp://secunia.com/advisories/about_secunia_advisories/\n\n\nPlease Note:\nSecunia recommends that you verify all advisories you receive by\nclicking the link. \nSecunia NEVER sends attached files with advisories. \nSecunia does not advise people to install third party patches, only\nuse those supplied by the vendor. \n\n----------------------------------------------------------------------\n\nUnsubscribe: Secunia Security Advisories\nhttp://secunia.com/sec_adv_unsubscribe/?email=packet%40packetstormsecurity.org\n\n----------------------------------------------------------------------\n\n\n",
"sources": [
{
"db": "NVD",
"id": "CVE-2011-4033"
},
{
"db": "JVNDB",
"id": "JVNDB-2011-003182"
},
{
"db": "CNVD",
"id": "CNVD-2011-5098"
},
{
"db": "BID",
"id": "50835"
},
{
"db": "IVD",
"id": "5a41c13e-2354-11e6-abef-000c29c66e3d"
},
{
"db": "VULHUB",
"id": "VHN-51978"
},
{
"db": "PACKETSTORM",
"id": "107379"
}
],
"trust": 2.79
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2011-4033",
"trust": 3.6
},
{
"db": "ICS CERT",
"id": "ICSA-11-307-01",
"trust": 3.5
},
{
"db": "BID",
"id": "50835",
"trust": 1.0
},
{
"db": "CNNVD",
"id": "CNNVD-201111-488",
"trust": 0.9
},
{
"db": "CNVD",
"id": "CNVD-2011-5098",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2011-003182",
"trust": 0.8
},
{
"db": "SECUNIA",
"id": "47046",
"trust": 0.8
},
{
"db": "NSFOCUS",
"id": "18244",
"trust": 0.6
},
{
"db": "NSFOCUS",
"id": "18254",
"trust": 0.6
},
{
"db": "IVD",
"id": "5A41C13E-2354-11E6-ABEF-000C29C66E3D",
"trust": 0.2
},
{
"db": "VULHUB",
"id": "VHN-51978",
"trust": 0.1
},
{
"db": "PACKETSTORM",
"id": "107379",
"trust": 0.1
}
],
"sources": [
{
"db": "IVD",
"id": "5a41c13e-2354-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2011-5098"
},
{
"db": "VULHUB",
"id": "VHN-51978"
},
{
"db": "BID",
"id": "50835"
},
{
"db": "JVNDB",
"id": "JVNDB-2011-003182"
},
{
"db": "PACKETSTORM",
"id": "107379"
},
{
"db": "CNNVD",
"id": "CNNVD-201111-488"
},
{
"db": "NVD",
"id": "CVE-2011-4033"
}
]
},
"id": "VAR-201112-0156",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "IVD",
"id": "5a41c13e-2354-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2011-5098"
},
{
"db": "VULHUB",
"id": "VHN-51978"
}
],
"trust": 1.630476174
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.8
}
],
"sources": [
{
"db": "IVD",
"id": "5a41c13e-2354-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2011-5098"
}
]
},
"last_update_date": "2025-04-11T23:02:04.063000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "MyCitect Support",
"trust": 0.8,
"url": "http://www.scada.schneider-electric.com/sites/scada/en/login/historian-vulnerability.page"
},
{
"title": "Citect is now Schneider Electric",
"trust": 0.8,
"url": "http://www2.schneider-electric.com/sites/corporate/en/products-services/former-brands/citect/citect.page"
},
{
"title": "Top Page",
"trust": 0.8,
"url": "http://www.schneider-electric.com/"
},
{
"title": "\u30b5\u30dd\u30fc\u30c8",
"trust": 0.8,
"url": "http://www.schneider-electric.co.jp/sites/japan/jp/support/contact/we-care.page"
},
{
"title": "Top Page",
"trust": 0.8,
"url": "http://www.schneider-electric.com/site/home/index.cfm/jp/"
},
{
"title": "TeeChart ActiveX Control Buffer Overflow Denial of Service Vulnerability Patch",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/6054"
},
{
"title": "V4.10-Combined-Fix-HF41053653",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=41929"
},
{
"title": "V4.20-Combined-Fix-HF42053652",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=41928"
},
{
"title": "V4.30-Combined-Fix-HF43053651",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=41927"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2011-5098"
},
{
"db": "JVNDB",
"id": "JVNDB-2011-003182"
},
{
"db": "CNNVD",
"id": "CNNVD-201111-488"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-119",
"trust": 1.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-51978"
},
{
"db": "JVNDB",
"id": "JVNDB-2011-003182"
},
{
"db": "NVD",
"id": "CVE-2011-4033"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 3.5,
"url": "http://www.us-cert.gov/control_systems/pdf/icsa-11-307-01.pdf"
},
{
"trust": 2.0,
"url": "http://www.scada.schneider-electric.com/sites/scada/en/login/historian-vulnerability.page"
},
{
"trust": 1.7,
"url": "http://www.citect.com/index.php?option=com_content\u0026view=article\u0026id=1656\u0026itemid=1695"
},
{
"trust": 0.8,
"url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2011-4033"
},
{
"trust": 0.8,
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2011-4033"
},
{
"trust": 0.6,
"url": "http://secunia.com/advisories/47046"
},
{
"trust": 0.6,
"url": "http://www.securityfocus.com/bid/50835"
},
{
"trust": 0.6,
"url": "http://www.nsfocus.net/vulndb/18254"
},
{
"trust": 0.6,
"url": "http://www.nsfocus.net/vulndb/18244"
},
{
"trust": 0.3,
"url": "http://www.steema.com/"
},
{
"trust": 0.1,
"url": "http://www.citect.com/index.php?option=com_content\u0026amp;view=article\u0026amp;id=1656\u0026amp;itemid=1695"
},
{
"trust": 0.1,
"url": "https://ca.secunia.com/?page=viewadvisory\u0026vuln_id=47046"
},
{
"trust": 0.1,
"url": "http://secunia.com/company/jobs/"
},
{
"trust": 0.1,
"url": "http://secunia.com/vulnerability_intelligence/"
},
{
"trust": 0.1,
"url": "http://secunia.com/advisories/47046/"
},
{
"trust": 0.1,
"url": "http://secunia.com/vulnerability_scanning/corporate/wsus_sccm_3rd_third_party_patching/"
},
{
"trust": 0.1,
"url": "http://secunia.com/advisories/secunia_security_advisories/"
},
{
"trust": 0.1,
"url": "http://secunia.com/vulnerability_scanning/personal/"
},
{
"trust": 0.1,
"url": "http://secunia.com/advisories/47046/#comments"
},
{
"trust": 0.1,
"url": "http://secunia.com/sec_adv_unsubscribe/?email=packet%40packetstormsecurity.org"
},
{
"trust": 0.1,
"url": "http://secunia.com/advisories/about_secunia_advisories/"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2011-5098"
},
{
"db": "VULHUB",
"id": "VHN-51978"
},
{
"db": "BID",
"id": "50835"
},
{
"db": "JVNDB",
"id": "JVNDB-2011-003182"
},
{
"db": "PACKETSTORM",
"id": "107379"
},
{
"db": "CNNVD",
"id": "CNNVD-201111-488"
},
{
"db": "NVD",
"id": "CVE-2011-4033"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "IVD",
"id": "5a41c13e-2354-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2011-5098"
},
{
"db": "VULHUB",
"id": "VHN-51978"
},
{
"db": "BID",
"id": "50835"
},
{
"db": "JVNDB",
"id": "JVNDB-2011-003182"
},
{
"db": "PACKETSTORM",
"id": "107379"
},
{
"db": "CNNVD",
"id": "CNNVD-201111-488"
},
{
"db": "NVD",
"id": "CVE-2011-4033"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2011-12-05T00:00:00",
"db": "IVD",
"id": "5a41c13e-2354-11e6-abef-000c29c66e3d"
},
{
"date": "2011-12-05T00:00:00",
"db": "CNVD",
"id": "CNVD-2011-5098"
},
{
"date": "2011-12-02T00:00:00",
"db": "VULHUB",
"id": "VHN-51978"
},
{
"date": "2011-11-28T00:00:00",
"db": "BID",
"id": "50835"
},
{
"date": "2011-12-05T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2011-003182"
},
{
"date": "2011-11-29T04:13:32",
"db": "PACKETSTORM",
"id": "107379"
},
{
"date": "1900-01-01T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201111-488"
},
{
"date": "2011-12-02T11:55:05.090000",
"db": "NVD",
"id": "CVE-2011-4033"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2011-12-05T00:00:00",
"db": "CNVD",
"id": "CNVD-2011-5098"
},
{
"date": "2011-12-02T00:00:00",
"db": "VULHUB",
"id": "VHN-51978"
},
{
"date": "2015-03-19T09:08:00",
"db": "BID",
"id": "50835"
},
{
"date": "2011-12-05T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2011-003182"
},
{
"date": "2011-12-12T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201111-488"
},
{
"date": "2025-04-11T00:51:21.963000",
"db": "NVD",
"id": "CVE-2011-4033"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201111-488"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "TeeChart ActiveX Control Buffer Overflow Denial of Service Vulnerability",
"sources": [
{
"db": "IVD",
"id": "5a41c13e-2354-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2011-5098"
},
{
"db": "BID",
"id": "50835"
}
],
"trust": 1.1
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Buffer overflow",
"sources": [
{
"db": "IVD",
"id": "5a41c13e-2354-11e6-abef-000c29c66e3d"
},
{
"db": "CNNVD",
"id": "CNNVD-201111-488"
}
],
"trust": 0.8
}
}
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.