CNVD-2016-10732
Vulnerability from cnvd - Published: 2016-11-08厂商已发布安全公告修复该漏洞,请及时关注更新: https://support.industry.siemens.com/cs/ww/en/view/109741519 https://support.industry.siemens.com/cs/ww/en/view/109741127 https://support.industry.siemens.com/cs/ww/en/view/109742642 https://support.industry.siemens.com/cs/ww/en/view/109739719 https://support.industry.siemens.com/cs/ww/en/view/109740340 https://support.industry.siemens.com/cs/ww/en/view/109741996 https://support.industry.siemens.com/cs/ww/en/view/109483119 https://support.industry.siemens.com/cs/ww/en/view/109741833 https://support.industry.siemens.com/cs/ww/en/view/109743963 https://support.industry.siemens.com/cs/ww/en/view/109744041 其他版本的临时修复参考如下链接: https://support.industry.siemens.com/cs/ww/en/view/109740929
| Name | ['Siemens SIMATIC STEP 7 5.x', 'SIEMENS SIMATIC PCS 7 8.0', 'SIEMENS SIMATIC PCS 7 8.1\x7f', 'SIEMENS SIMATIC PCS 7 8.2', 'SIEMENS SIMATIC WinCC 7.3 x', 'SIEMENS SIMATIC WinCC 7.4 x', 'Siemens SINEMA Server', 'SIEMENS SIMATIC WinCC 7.2 x', 'SIEMENS SIMATIC WinCC 7.0 SP2,<7.0 SP2 Upd 12', 'SIEMENS SIMATIC WinCC 7.0 SP3,<7.0 SP3 Upd 8', 'SIEMENS SIMATIC NET PC-Software <14', 'SIEMENS SIMATIC WinCC Runtime Professional All', 'Siemens SIMATIC STEP 7 (TIA Portal) <14', 'SIEMENS SIMATIC WinCC (TIA Portal) Basic <14', 'SIEMENS SIMATIC WinCC (TIA Portal) Comfort <14', 'SIEMENS SIMATIC WinCC (TIA Portal) Advanced <14', 'SIEMENS SIMATIC WinCC (TIA Portal) Professional All', 'SIEMENS SINEMA Remote Connect Client All', 'SIEMENS SIMATIC WinAC RTX 2010 SP2 All', 'SIEMENS SIMATIC WinAC RTX F 2010 SP2 All', 'SIEMENS SIMATIC IT Production Suite All', 'SIEMENS TeleControl Server Basic <3.0 SP2', 'SIEMENS SOFTNET Security Client V5.0 All', 'SIEMENS SIMIT 9.0', 'SIEMENS Security Configuration Tool (SCT) All', 'SIEMENS Primary Setup Tool (PST) All'] |
|---|
{
"cves": {
"cve": {
"cveNumber": "CVE-2016-7165"
}
},
"description": "\u5fb7\u56fd\u897f\u95e8\u5b50\u80a1\u4efd\u516c\u53f8\u521b\u7acb\u4e8e1847\u5e74\uff0c\u4e13\u6ce8\u4e8e\u7535\u6c14\u5316\u3001\u81ea\u52a8\u5316\u548c\u6570\u5b57\u5316\u9886\u57df\u3002\u897f\u95e8\u5b50\u5728\u6d77\u4e0a\u98ce\u673a\u5efa\u8bbe\u3001\u71c3\u6c14\u8f6e\u673a\u548c\u84b8\u6c7d\u8f6e\u673a\u53d1\u7535\u3001\u8f93\u7535\u89e3\u51b3\u65b9\u6848\u3001\u57fa\u7840\u8bbe\u65bd\u89e3\u51b3\u65b9\u6848\u3001\u5de5\u4e1a\u81ea\u52a8\u5316\u3001\u9a71\u52a8\u548c\u8f6f\u4ef6\u89e3\u51b3\u65b9\u6848\uff0c\u4ee5\u53ca\u533b\u7597\u6210\u50cf\u8bbe\u5907\u548c\u5b9e\u9a8c\u5ba4\u8bca\u65ad\u7b49\u9886\u57df\u5360\u636e\u9886\u5148\u5730\u4f4d\u3002\r\n\r\nSiemens\u591a\u6b3e\u4ea7\u54c1\u5b58\u5728\u6743\u9650\u63d0\u5347\u6f0f\u6d1e\u3002\u5f53\u53d7\u5f71\u54cd\u7684\u4ea7\u54c1\u672a\u5b89\u88c5\u5728\u9ed8\u8ba4\u8def\u5f84\u201cC:\\ Program Files \\ *\u201d\u4e0b\u65f6\uff0c\u975e\u6302\u724c\u670d\u52a1\u8def\u5f84\u53ef\u4ee5\u5141\u8bb8\u672c\u5730Microsoft Windows\u64cd\u4f5c\u7cfb\u7edf\u7528\u6237\u63d0\u5347\u6743\u9650\u3002",
"discovererName": "WATERSURE and KIANDRA IT",
"formalWay": "\u5382\u5546\u5df2\u53d1\u5e03\u5b89\u5168\u516c\u544a\u4fee\u590d\u8be5\u6f0f\u6d1e\uff0c\u8bf7\u53ca\u65f6\u5173\u6ce8\u66f4\u65b0\uff1a \r\nhttps://support.industry.siemens.com/cs/ww/en/view/109741519\r\nhttps://support.industry.siemens.com/cs/ww/en/view/109741127\r\nhttps://support.industry.siemens.com/cs/ww/en/view/109742642\r\nhttps://support.industry.siemens.com/cs/ww/en/view/109739719\r\nhttps://support.industry.siemens.com/cs/ww/en/view/109740340\r\nhttps://support.industry.siemens.com/cs/ww/en/view/109741996\r\nhttps://support.industry.siemens.com/cs/ww/en/view/109483119\r\nhttps://support.industry.siemens.com/cs/ww/en/view/109741833\r\nhttps://support.industry.siemens.com/cs/ww/en/view/109743963\r\nhttps://support.industry.siemens.com/cs/ww/en/view/109744041\r\n\u5176\u4ed6\u7248\u672c\u7684\u4e34\u65f6\u4fee\u590d\u53c2\u8003\u5982\u4e0b\u94fe\u63a5\uff1a\r\nhttps://support.industry.siemens.com/cs/ww/en/view/109740929",
"isEvent": "\u901a\u7528\u8f6f\u786c\u4ef6\u6f0f\u6d1e",
"number": "CNVD-2016-10732",
"openTime": "2016-11-08",
"patchDescription": "SIMATIC WinCC(Windows Control Center)\u89c6\u7a97\u63a7\u5236\u4e2d\u5fc3\uff0c\u662f\u897f\u95e8\u5b50\u7684\u8fc7\u7a0b\u76d1\u89c6\u7cfb\u7edf\uff0c\u4e3a\u5de5\u4e1a\u9886\u57df\u63d0\u4f9b\u5b8c\u5907\u7684\u76d1\u63a7\u4e0e\u6570\u636e\u91c7\u96c6\uff08SCADA\uff09\u529f\u80fd\uff1bPCS 7\u7cfb\u7edf\u662f\u65e0\u7f1d\u96c6\u6210\u7684\u81ea\u52a8\u5316\u89e3\u51b3\u65b9\u6848\uff0c\u53ef\u4ee5\u5e94\u7528\u4e8e\u6240\u6709\u5de5\u4e1a\u9886\u57df\u3002\r\n\r\nSiemens\u591a\u6b3e\u4ea7\u54c1\u5b58\u5728\u6743\u9650\u63d0\u5347\u6f0f\u6d1e\u3002\u5f53\u53d7\u5f71\u54cd\u7684\u4ea7\u54c1\u672a\u5b89\u88c5\u5728\u9ed8\u8ba4\u8def\u5f84\u201cC:\\ Program Files \\ *\u201d\u4e0b\u65f6\uff0c\u975e\u6302\u724c\u670d\u52a1\u8def\u5f84\u53ef\u4ee5\u5141\u8bb8\u672c\u5730Microsoft Windows\u64cd\u4f5c\u7cfb\u7edf\u7528\u6237\u63d0\u5347\u6743\u9650\u3002\u62e5\u6709\u53d7\u5f71\u54cd\u4ea7\u54c1\u7684\u672c\u5730\u64cd\u4f5c\u7cfb\u7edf\u8bbf\u95ee\u6743\u9650\u7684\u672c\u5730\u653b\u51fb\u8005\u5229\u7528\u6f0f\u6d1e\u53ef\u63d0\u5347\u6743\u9650\u3002\u76ee\u524d\uff0c\u4f9b\u5e94\u5546\u53d1\u5e03\u4e86\u5b89\u5168\u516c\u544a\u53ca\u76f8\u5173\u8865\u4e01\u4fe1\u606f\uff0c\u4fee\u590d\u4e86\u6b64\u6f0f\u6d1e\u3002",
"patchName": "Siemens\u591a\u6b3e\u4ea7\u54c1\u5b58\u5728\u6743\u9650\u63d0\u5347\u6f0f\u6d1e\uff08CNVD-2016-10732\uff09\u7684\u8865\u4e01",
"products": {
"product": [
"Siemens SIMATIC STEP 7 5.x",
"SIEMENS SIMATIC PCS 7 8.0",
"SIEMENS SIMATIC PCS 7 8.1\u007f",
"SIEMENS SIMATIC PCS 7 8.2",
"SIEMENS SIMATIC WinCC 7.3 x",
"SIEMENS SIMATIC WinCC 7.4 x",
"Siemens SINEMA Server",
"SIEMENS SIMATIC WinCC 7.2 x",
"SIEMENS SIMATIC WinCC 7.0 SP2\uff0c\u003c7.0 SP2 Upd 12",
"SIEMENS SIMATIC WinCC 7.0 SP3\uff0c\u003c7.0 SP3 Upd 8",
"SIEMENS SIMATIC NET PC-Software \u003c14",
"SIEMENS SIMATIC WinCC Runtime Professional All",
"Siemens SIMATIC STEP 7 (TIA Portal) \u003c14",
"SIEMENS SIMATIC WinCC (TIA Portal) Basic \u003c14",
"SIEMENS SIMATIC WinCC (TIA Portal) Comfort \u003c14",
"SIEMENS SIMATIC WinCC (TIA Portal) Advanced \u003c14",
"SIEMENS SIMATIC WinCC (TIA Portal) Professional All",
"SIEMENS SINEMA Remote Connect Client All",
"SIEMENS SIMATIC WinAC RTX 2010 SP2 All",
"SIEMENS SIMATIC WinAC RTX F 2010 SP2 All",
"SIEMENS SIMATIC IT Production Suite All",
"SIEMENS TeleControl Server Basic \u003c3.0 SP2",
"SIEMENS SOFTNET Security Client V5.0 All",
"SIEMENS SIMIT 9.0",
"SIEMENS Security Configuration Tool (SCT) All",
"SIEMENS Primary Setup Tool (PST) All"
]
},
"referenceLink": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-701708.pdf",
"serverity": "\u4e2d",
"submitTime": "2016-11-08",
"title": "Siemens\u591a\u6b3e\u4ea7\u54c1\u5b58\u5728\u6743\u9650\u63d0\u5347\u6f0f\u6d1e\uff08CNVD-2016-10732\uff09"
}
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.