CNVD-2016-09879
Vulnerability from cnvd - Published: 2016-10-24SM-2556模块厂商尚未提供补丁,可参考如下临时解决办法: 1、使用防火墙或IPSec功能禁止sm-2558模块访问2404/TCP端口; 2、在可信任的网络运行RTU。
SM-2558模块可升级至ETA4 revision 08,参考如下链接: http://w3.siemens.com/smartgrid/global/en/products-systems-solutions/substation-automation/substation-automation/Pages/Overview.aspx
| Name | ['Siemens ETA4 firmware (all versions < revision 08) of the SM-2558 extension module for SICAM AK', 'Siemens ETA4 firmware (all versions < revision 08) of the SM-2558 extension module for SICAM TM 1703', 'Siemens ETA4 firmware (all versions < revision 08) of the SM-2558 extension module for SICAM BC 1703', 'Siemens ETA4 firmware (all versions < revision 08) of the SM-2558 extension module for SICAM AK 3', 'Siemens ETA2 firmware (revision 11.01 and earlier) of the SM-2556 extension module for SICAM AK', 'Siemens ETA2 firmware (revision 11.01 and earlier) of the SM-2556 extension module for SICAM BC', 'Siemens ETA2 firmware (revision 11.01 and earlier) of the SM-2556 extension module for SICAM TM'] |
|---|
{
"cves": {
"cve": {
"cveNumber": "CVE-2016-7987"
}
},
"description": "Siemens sm-2558\u548csm-2556\u901a\u4fe1\u6a21\u5757\u662fLAN/WAN\u7684\u5feb\u901f\u4ee5\u592a\u7f51\u901a\u4fe1\u63a5\u53e3\u5355\u5143\u3002\r\n\r\nSiemens SICAM RTU\u8bbe\u5907\u5b58\u5728\u62d2\u7edd\u670d\u52a1\u6f0f\u6d1e\u3002\u7531\u4e8e\u7279\u5236\u7684\u6570\u636e\u5305\u53d1\u9001\u52302404/TCP\u7aef\u53e3\u53ef\u80fd\u4f1a\u5bfc\u81f4\u53d7\u5f71\u54cd\u7684\u8bbe\u5907\u8fdb\u5165\u7f3a\u9677\u6a21\u5f0f\uff0c\u8fdc\u7a0b\u653b\u51fb\u8005\u5229\u7528\u6f0f\u6d1e\u53ef\u53d1\u8d77\u62d2\u7edd\u670d\u52a1\u653b\u51fb\u3002",
"discovererName": "Stephan Beirer, Markus Mahrla, Toralf Gimpel, Sebastian Krause, NetConsult GmbH, Adam Crain, Bundesamt f\u00fcr Sicherheit",
"formalWay": "SM-2556\u6a21\u5757\u5382\u5546\u5c1a\u672a\u63d0\u4f9b\u8865\u4e01\uff0c\u53ef\u53c2\u8003\u5982\u4e0b\u4e34\u65f6\u89e3\u51b3\u529e\u6cd5\uff1a\r\n1\u3001\u4f7f\u7528\u9632\u706b\u5899\u6216IPSec\u529f\u80fd\u7981\u6b62sm-2558\u6a21\u5757\u8bbf\u95ee2404/TCP\u7aef\u53e3\uff1b\r\n2\u3001\u5728\u53ef\u4fe1\u4efb\u7684\u7f51\u7edc\u8fd0\u884cRTU\u3002\r\n\r\nSM-2558\u6a21\u5757\u53ef\u5347\u7ea7\u81f3ETA4 revision 08\uff0c\u53c2\u8003\u5982\u4e0b\u94fe\u63a5\uff1a\r\nhttp://w3.siemens.com/smartgrid/global/en/products-systems-solutions/substation-automation/substation-automation/Pages/Overview.aspx",
"isEvent": "\u901a\u7528\u8f6f\u786c\u4ef6\u6f0f\u6d1e",
"number": "CNVD-2016-09879",
"openTime": "2016-10-24",
"patchDescription": "Siemens sm-2558\u548csm-2556\u901a\u4fe1\u6a21\u5757\u662fLAN/WAN\u7684\u5feb\u901f\u4ee5\u592a\u7f51\u901a\u4fe1\u63a5\u53e3\u5355\u5143\u3002\r\n\r\nSiemens SICAM RTU\u8bbe\u5907\u5b58\u5728\u62d2\u7edd\u670d\u52a1\u6f0f\u6d1e\u3002\u7531\u4e8e\u7279\u5236\u7684\u6570\u636e\u5305\u53d1\u9001\u52302404/TCP\u7aef\u53e3\u53ef\u80fd\u4f1a\u5bfc\u81f4\u53d7\u5f71\u54cd\u7684\u8bbe\u5907\u8fdb\u5165\u7f3a\u9677\u6a21\u5f0f\uff0c\u8fdc\u7a0b\u653b\u51fb\u8005\u5229\u7528\u6f0f\u6d1e\u53ef\u53d1\u8d77\u62d2\u7edd\u670d\u52a1\u653b\u51fb\u3002\u76ee\u524d\uff0c\u4f9b\u5e94\u5546\u53d1\u5e03\u4e86\u5b89\u5168\u516c\u544a\u53ca\u76f8\u5173\u8865\u4e01\u4fe1\u606f\uff0c\u4fee\u590d\u4e86\u6b64\u6f0f\u6d1e\u3002",
"patchName": "Siemens SICAM RTU\u8bbe\u5907\u5b58\u5728\u62d2\u7edd\u670d\u52a1\u6f0f\u6d1e\u7684\u8865\u4e01",
"products": {
"product": [
"Siemens ETA4 firmware (all versions \u003c revision 08) of the SM-2558 extension module for SICAM AK",
"Siemens ETA4 firmware (all versions \u003c revision 08) of the SM-2558 extension module for SICAM TM 1703",
"Siemens ETA4 firmware (all versions \u003c revision 08) of the SM-2558 extension module for SICAM BC 1703",
"Siemens ETA4 firmware (all versions \u003c revision 08) of the SM-2558 extension module for SICAM AK 3",
"Siemens ETA2 firmware (revision 11.01 and earlier) of the SM-2556 extension module for SICAM AK",
"Siemens ETA2 firmware (revision 11.01 and earlier) of the SM-2556 extension module for SICAM BC",
"Siemens ETA2 firmware (revision 11.01 and earlier) of the SM-2556 extension module for SICAM TM"
]
},
"referenceLink": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-296574.pdf",
"serverity": "\u9ad8",
"submitTime": "2016-10-24",
"title": "Siemens SICAM RTU\u8bbe\u5907\u5b58\u5728\u62d2\u7edd\u670d\u52a1\u6f0f\u6d1e"
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.