Action not permitted
Modal body text goes here.
Modal Title
Modal Body
CERTFR-2021-AVI-953
Vulnerability from certfr_avis - Published: 2021-12-15 - Updated: 2021-12-15
De multiples vulnérabilités ont été découvertes dans les produits Schneider. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et un contournement de la politique de sécurité.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
NoneImpacted products
| Vendor | Product | Description | ||
|---|---|---|---|---|
| N/A | N/A | SCD6000 Industrial RTU version SCD6000 SY11012 11_M et antérieures | ||
| N/A | N/A | Modicon BMENOC 0311 | ||
| N/A | N/A | EVlink City (EVC1S22P4 / EVC1S7P4), EVlink Parking (EVW2 / EVF2 / EVP2PE), EVlink Smart Wallbox EVB1A toutes versions antérieures à R8 V3.4.0.2 | ||
| N/A | N/A | Modicon BMENOC 0321 | ||
| N/A | N/A | Modicon M580 | ||
| N/A | N/A | EcoStruxure™ Power Monitoring Expert versions V9.0 et antérieures | ||
| N/A | N/A | IGSS Data Collector (dc.exe) version 15.0.0.21320 et antérieures | ||
| N/A | N/A | APDU9xxx with NMC3 version V1.0.0.28 et antérieures | ||
| N/A | N/A | AP7xxxx and AP8xxx with NMC2 version V6.9.6 et antérieures | ||
| N/A | N/A | AP7xxx and AP8xxx with NMC3 version V1.1.0.3 et antérieures |
References
| Title | Publication Time | Tags | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "SCD6000 Industrial RTU version SCD6000 SY11012 11_M et ant\u00e9rieures",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "Modicon BMENOC 0311",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "EVlink City (EVC1S22P4 / EVC1S7P4), EVlink Parking (EVW2 / EVF2 / EVP2PE), EVlink Smart Wallbox EVB1A toutes versions ant\u00e9rieures \u00e0 R8 V3.4.0.2",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "Modicon BMENOC 0321",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "Modicon M580",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "EcoStruxure\u2122 Power Monitoring Expert versions V9.0 et ant\u00e9rieures",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "IGSS Data Collector (dc.exe) version 15.0.0.21320 et ant\u00e9rieures",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "APDU9xxx with NMC3 version V1.0.0.28 et ant\u00e9rieures",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "AP7xxxx and AP8xxx with NMC2 version V6.9.6 et ant\u00e9rieures",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "AP7xxx and AP8xxx with NMC3 version V1.1.0.3 et ant\u00e9rieures",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2020-35198",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-35198"
},
{
"name": "CVE-2021-22725",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22725"
},
{
"name": "CVE-2019-6848",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6848"
},
{
"name": "CVE-2021-22156",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22156"
},
{
"name": "CVE-2021-22823",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22823"
},
{
"name": "CVE-2021-22818",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22818"
},
{
"name": "CVE-2021-22820",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22820"
},
{
"name": "CVE-2021-22821",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22821"
},
{
"name": "CVE-2021-22824",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22824"
},
{
"name": "CVE-2021-22822",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22822"
},
{
"name": "CVE-2019-6849",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6849"
},
{
"name": "CVE-2021-22825",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22825"
},
{
"name": "CVE-2021-44228",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44228"
},
{
"name": "CVE-2021-22724",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22724"
},
{
"name": "CVE-2020-28895",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-28895"
},
{
"name": "CVE-2021-22826",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22826"
},
{
"name": "CVE-2019-6850",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6850"
},
{
"name": "CVE-2021-22827",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22827"
},
{
"name": "CVE-2021-22819",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22819"
}
],
"initial_release_date": "2021-12-15T00:00:00",
"last_revision_date": "2021-12-15T00:00:00",
"links": [],
"reference": "CERTFR-2021-AVI-953",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2021-12-15T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Injection de code indirecte \u00e0 distance (XSS)"
},
{
"description": "Injection de requ\u00eates ill\u00e9gitimes par rebond (CSRF)"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSchneider. Certaines d\u0027entre elles permettent \u00e0 un attaquant de\nprovoquer une ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de\nservice \u00e0 distance et un contournement de la politique de s\u00e9curit\u00e9.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Schneider",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-348-02 du 14 d\u00e9cembre 2021",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-02"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-348-01 du 14 d\u00e9cembre 2021",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-01"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SSEVD-2021-348-03 du 14 d\u00e9cembre 2021",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-03"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2019-281-04 du 14 d\u00e9cembre 2021",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2019-281-04"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-348-04 du 14 d\u00e9cembre 2021",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-04"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-313-05 du 14 d\u00e9cembre 2021",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-05"
}
]
}
CVE-2021-22820 (GCVE-0-2021-22820)
Vulnerability from cvelistv5 – Published: 2022-01-28 19:09 – Updated: 2024-08-03 18:51
VLAI
EPSS
Summary
A CWE-614 Insufficient Session Expiration vulnerability exists that could allow an attacker to maintain an unauthorized access over a hijacked session to the charger station web server even after the legitimate user account holder has changed his password. Affected Products: EVlink City EVC1S22P4 / EVC1S7P4 (All versions prior to R8 V3.4.0.2 ), EVlink Parking EVW2 / EVF2 / EVP2PE (All versions prior to R8 V3.4.0.2), and EVlink Smart Wallbox EVB1A (All versions prior to R8 V3.4.0.2)
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://download.schneider-electric.com/files?p_D… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T18:51:07.469Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-02"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-614 Insufficient Session Expiration vulnerability exists that could allow an attacker to maintain an unauthorized access over a hijacked session to the charger station web server even after the legitimate user account holder has changed his password. Affected Products: EVlink City EVC1S22P4 / EVC1S7P4 (All versions prior to R8 V3.4.0.2 ), EVlink Parking EVW2 / EVF2 / EVP2PE (All versions prior to R8 V3.4.0.2), and EVlink Smart Wallbox EVB1A (All versions prior to R8 V3.4.0.2)"
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-01-28T19:09:36.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-02"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2021-22820",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-614 Insufficient Session Expiration vulnerability exists that could allow an attacker to maintain an unauthorized access over a hijacked session to the charger station web server even after the legitimate user account holder has changed his password. Affected Products: EVlink City EVC1S22P4 / EVC1S7P4 (All versions prior to R8 V3.4.0.2 ), EVlink Parking EVW2 / EVF2 / EVP2PE (All versions prior to R8 V3.4.0.2), and EVlink Smart Wallbox EVB1A (All versions prior to R8 V3.4.0.2)"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-02",
"refsource": "MISC",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-02"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2021-22820",
"datePublished": "2022-01-28T19:09:36.000Z",
"dateReserved": "2021-01-06T00:00:00.000Z",
"dateUpdated": "2024-08-03T18:51:07.469Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-22821 (GCVE-0-2021-22821)
Vulnerability from cvelistv5 – Published: 2022-01-28 19:09 – Updated: 2024-08-03 18:51
VLAI
EPSS
Summary
A CWE-918 Server-Side Request Forgery (SSRF) vulnerability exists that could cause the station web server to forward requests to unintended network targets when crafted malicious parameters are submitted to the charging station web server. Affected Products: EVlink City EVC1S22P4 / EVC1S7P4 (All versions prior to R8 V3.4.0.2 ), EVlink Parking EVW2 / EVF2 / EVP2PE (All versions prior to R8 V3.4.0.2), and EVlink Smart Wallbox EVB1A (All versions prior to R8 V3.4.0.2)
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://download.schneider-electric.com/files?p_D… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T18:51:07.453Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-02"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-918 Server-Side Request Forgery (SSRF) vulnerability exists that could cause the station web server to forward requests to unintended network targets when crafted malicious parameters are submitted to the charging station web server. Affected Products: EVlink City EVC1S22P4 / EVC1S7P4 (All versions prior to R8 V3.4.0.2 ), EVlink Parking EVW2 / EVF2 / EVP2PE (All versions prior to R8 V3.4.0.2), and EVlink Smart Wallbox EVB1A (All versions prior to R8 V3.4.0.2)"
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-01-28T19:09:37.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-02"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2021-22821",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-918 Server-Side Request Forgery (SSRF) vulnerability exists that could cause the station web server to forward requests to unintended network targets when crafted malicious parameters are submitted to the charging station web server. Affected Products: EVlink City EVC1S22P4 / EVC1S7P4 (All versions prior to R8 V3.4.0.2 ), EVlink Parking EVW2 / EVF2 / EVP2PE (All versions prior to R8 V3.4.0.2), and EVlink Smart Wallbox EVB1A (All versions prior to R8 V3.4.0.2)"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-02",
"refsource": "MISC",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-02"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2021-22821",
"datePublished": "2022-01-28T19:09:37.000Z",
"dateReserved": "2021-01-06T00:00:00.000Z",
"dateUpdated": "2024-08-03T18:51:07.453Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-22822 (GCVE-0-2021-22822)
Vulnerability from cvelistv5 – Published: 2022-01-28 19:09 – Updated: 2024-08-03 18:51
VLAI
EPSS
Summary
A CWE-79 Improper Neutralization of Input During Web Page Generation (�Cross-site Scripting�) vulnerability exists that could allow an attacker to impersonate the user who manages the charging station or carry out actions on their behalf when crafted malicious parameters are submitted to the charging station web server. Affected Products: EVlink City EVC1S22P4 / EVC1S7P4 (All versions prior to R8 V3.4.0.2 ), EVlink Parking EVW2 / EVF2 / EVP2PE (All versions prior to R8 V3.4.0.2), and EVlink Smart Wallbox EVB1A (All versions prior to R8 V3.4.0.2)
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://download.schneider-electric.com/files?p_D… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T18:51:07.563Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-02"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-79 Improper Neutralization of Input During Web Page Generation (\ufffdCross-site Scripting\ufffd) vulnerability exists that could allow an attacker to impersonate the user who manages the charging station or carry out actions on their behalf when crafted malicious parameters are submitted to the charging station web server. Affected Products: EVlink City EVC1S22P4 / EVC1S7P4 (All versions prior to R8 V3.4.0.2 ), EVlink Parking EVW2 / EVF2 / EVP2PE (All versions prior to R8 V3.4.0.2), and EVlink Smart Wallbox EVB1A (All versions prior to R8 V3.4.0.2)"
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-01-28T19:09:38.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-02"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2021-22822",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-79 Improper Neutralization of Input During Web Page Generation (\ufffdCross-site Scripting\ufffd) vulnerability exists that could allow an attacker to impersonate the user who manages the charging station or carry out actions on their behalf when crafted malicious parameters are submitted to the charging station web server. Affected Products: EVlink City EVC1S22P4 / EVC1S7P4 (All versions prior to R8 V3.4.0.2 ), EVlink Parking EVW2 / EVF2 / EVP2PE (All versions prior to R8 V3.4.0.2), and EVlink Smart Wallbox EVB1A (All versions prior to R8 V3.4.0.2)"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-02",
"refsource": "MISC",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-02"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2021-22822",
"datePublished": "2022-01-28T19:09:38.000Z",
"dateReserved": "2021-01-06T00:00:00.000Z",
"dateUpdated": "2024-08-03T18:51:07.563Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-22823 (GCVE-0-2021-22823)
Vulnerability from cvelistv5 – Published: 2022-02-11 17:40 – Updated: 2024-08-03 18:51
VLAI
EPSS
Summary
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause deletion of arbitrary files in the context of the user running IGSS due to lack of validation of network messages. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21320 and prior)
Severity
No CVSS data available.
CWE
- CWE-306 - Missing Authentication for Critical Function
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://download.schneider-electric.com/files?p_D… | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21320 and prior) |
Affected:
Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21320 and prior)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T18:51:07.467Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21320 and prior)",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21320 and prior)"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause deletion of arbitrary files in the context of the user running IGSS due to lack of validation of network messages. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21320 and prior)"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306: Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-02-11T17:40:39.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-01"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2021-22823",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21320 and prior)",
"version": {
"version_data": [
{
"version_value": "Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21320 and prior)"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause deletion of arbitrary files in the context of the user running IGSS due to lack of validation of network messages. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21320 and prior)"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-306: Missing Authentication for Critical Function"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-01",
"refsource": "MISC",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-01"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2021-22823",
"datePublished": "2022-02-11T17:40:39.000Z",
"dateReserved": "2021-01-06T00:00:00.000Z",
"dateUpdated": "2024-08-03T18:51:07.467Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-22824 (GCVE-0-2021-22824)
Vulnerability from cvelistv5 – Published: 2022-02-11 17:40 – Updated: 2024-08-03 18:51
VLAI
EPSS
Summary
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could result in denial of service, due to missing length check on user-supplied data from a constructed message received on the network. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21320 and prior)
Severity
No CVSS data available.
CWE
- CWE-120 - Buffer Copy without Checking Size of Input
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://download.schneider-electric.com/files?p_D… | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21320 and prior) |
Affected:
Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21320 and prior)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T18:51:07.555Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21320 and prior)",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21320 and prior)"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could result in denial of service, due to missing length check on user-supplied data from a constructed message received on the network. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21320 and prior)"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-120",
"description": "CWE-120: Buffer Copy without Checking Size of Input",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-02-11T17:40:40.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-01"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2021-22824",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21320 and prior)",
"version": {
"version_data": [
{
"version_value": "Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21320 and prior)"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could result in denial of service, due to missing length check on user-supplied data from a constructed message received on the network. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21320 and prior)"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-120: Buffer Copy without Checking Size of Input"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-01",
"refsource": "MISC",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-01"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2021-22824",
"datePublished": "2022-02-11T17:40:40.000Z",
"dateReserved": "2021-01-06T00:00:00.000Z",
"dateUpdated": "2024-08-03T18:51:07.555Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-22825 (GCVE-0-2021-22825)
Vulnerability from cvelistv5 – Published: 2022-01-28 19:09 – Updated: 2025-09-08 16:09
VLAI
EPSS
Summary
A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists that could allow an attacker to access the system with elevated privileges when a privileged account clicks on a malicious URL that compromises the security token. Affected Products: AP7xxxx and AP8xxx with NMC2 (V6.9.6 or earlier), AP7xxx and AP8xxx with NMC3 (V1.1.0.3 or earlier), and APDU9xxx with NMC3 (V1.0.0.28 or earlier)
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-200 - Exposure of Sensitive Information to an Unauthorized Actor
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://download.schneider-electric.com/files?p_D… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T18:51:07.440Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-04"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2021-22825",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-09-08T16:07:27.598238Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-200",
"description": "CWE-200 Exposure of Sensitive Information to an Unauthorized Actor",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-09-08T16:09:21.462Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists that could allow an attacker to access the system with elevated privileges when a privileged account clicks on a malicious URL that compromises the security token. Affected Products: AP7xxxx and AP8xxx with NMC2 (V6.9.6 or earlier), AP7xxx and AP8xxx with NMC3 (V1.1.0.3 or earlier), and APDU9xxx with NMC3 (V1.0.0.28 or earlier)"
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-01-28T19:09:40.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-04"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2021-22825",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists that could allow an attacker to access the system with elevated privileges when a privileged account clicks on a malicious URL that compromises the security token. Affected Products: AP7xxxx and AP8xxx with NMC2 (V6.9.6 or earlier), AP7xxx and AP8xxx with NMC3 (V1.1.0.3 or earlier), and APDU9xxx with NMC3 (V1.0.0.28 or earlier)"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-04",
"refsource": "MISC",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-04"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2021-22825",
"datePublished": "2022-01-28T19:09:40.000Z",
"dateReserved": "2021-01-06T00:00:00.000Z",
"dateUpdated": "2025-09-08T16:09:21.462Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-22826 (GCVE-0-2021-22826)
Vulnerability from cvelistv5 – Published: 2022-01-28 19:09 – Updated: 2024-08-03 18:51
VLAI
EPSS
Summary
A CWE-20: Improper Input Validation vulnerability exists that could cause arbitrary code execution when the user visits a page containing the injected payload. This CVE is unique from CVE-2021-22827. Affected Product: EcoStruxure� Power Monitoring Expert 9.0 and prior versions
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://download.schneider-electric.com/files?p_D… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T18:51:07.530Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-03"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-20: Improper Input Validation vulnerability exists that could cause arbitrary code execution when the user visits a page containing the injected payload. This CVE is unique from CVE-2021-22827. Affected Product: EcoStruxure\ufffd Power Monitoring Expert 9.0 and prior versions"
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-01-28T19:09:38.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-03"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2021-22826",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-20: Improper Input Validation vulnerability exists that could cause arbitrary code execution when the user visits a page containing the injected payload. This CVE is unique from CVE-2021-22827. Affected Product: EcoStruxure\ufffd Power Monitoring Expert 9.0 and prior versions"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-03",
"refsource": "MISC",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-03"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2021-22826",
"datePublished": "2022-01-28T19:09:38.000Z",
"dateReserved": "2021-01-06T00:00:00.000Z",
"dateUpdated": "2024-08-03T18:51:07.530Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-22827 (GCVE-0-2021-22827)
Vulnerability from cvelistv5 – Published: 2022-01-28 19:09 – Updated: 2024-08-03 18:51
VLAI
EPSS
Summary
A CWE-20: Improper Input Validation vulnerability exists that could cause arbitrary code execution when the user visits a page containing the injected payload. This CVE is unique from CVE-2021-22826. Affected Product: EcoStruxure� Power Monitoring Expert 9.0 and prior versions
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://download.schneider-electric.com/files?p_D… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T18:51:07.511Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-03"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-20: Improper Input Validation vulnerability exists that could cause arbitrary code execution when the user visits a page containing the injected payload. This CVE is unique from CVE-2021-22826. Affected Product: EcoStruxure\ufffd Power Monitoring Expert 9.0 and prior versions"
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-01-28T19:09:39.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-03"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2021-22827",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-20: Improper Input Validation vulnerability exists that could cause arbitrary code execution when the user visits a page containing the injected payload. This CVE is unique from CVE-2021-22826. Affected Product: EcoStruxure\ufffd Power Monitoring Expert 9.0 and prior versions"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-03",
"refsource": "MISC",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-348-03"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2021-22827",
"datePublished": "2022-01-28T19:09:39.000Z",
"dateReserved": "2021-01-06T00:00:00.000Z",
"dateUpdated": "2024-08-03T18:51:07.511Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-44228 (GCVE-0-2021-44228)
Vulnerability from cvelistv5 – Published: 2021-12-10 00:00 – Updated: 2025-10-21 23:25
VLAI
EPSS
Title
Apache Log4j2 JNDI features do not protect against attacker controlled LDAP and other JNDI related endpoints
Summary
Apache Log4j2 2.0-beta9 through 2.15.0 (excluding security releases 2.12.2, 2.12.3, and 2.3.1) JNDI features used in configuration, log messages, and parameters do not protect against attacker controlled LDAP and other JNDI related endpoints. An attacker who can control log messages or log message parameters can execute arbitrary code loaded from LDAP servers when message lookup substitution is enabled. From log4j 2.15.0, this behavior has been disabled by default. From version 2.16.0 (along with 2.12.2, 2.12.3, and 2.3.1), this functionality has been completely removed. Note that this vulnerability is specific to log4j-core and does not affect log4net, log4cxx, or other Apache Logging Services projects.
Severity
10 (Critical)
SSVC
Exploitation: active
Automatable: yes
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
Assigner
References
52 references
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Apache Software Foundation | Apache Log4j2 |
Affected:
2.0-beta9 , < log4j-core*
(custom)
|
Credits
This issue was discovered by Chen Zhaojun of Alibaba Cloud Security Team.
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T04:17:24.696Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://logging.apache.org/log4j/2.x/security.html"
},
{
"name": "[oss-security] 20211210 CVE-2021-44228: Apache Log4j2 JNDI features do not protect against attacker controlled LDAP and other JNDI related endpoints",
"tags": [
"mailing-list",
"x_transferred"
],
"url": "http://www.openwall.com/lists/oss-security/2021/12/10/1"
},
{
"name": "[oss-security] 20211210 Re: CVE-2021-44228: Apache Log4j2 JNDI features do not protect against attacker controlled LDAP and other JNDI related endpoints",
"tags": [
"mailing-list",
"x_transferred"
],
"url": "http://www.openwall.com/lists/oss-security/2021/12/10/2"
},
{
"name": "20211210 Vulnerability in Apache Log4j Library Affecting Cisco Products: December 2021",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-apache-log4j-qRuKNEbd"
},
{
"name": "[oss-security] 20211210 Re: CVE-2021-44228: Apache Log4j2 JNDI features do not protect against attacker controlled LDAP and other JNDI related endpoints",
"tags": [
"mailing-list",
"x_transferred"
],
"url": "http://www.openwall.com/lists/oss-security/2021/12/10/3"
},
{
"tags": [
"x_transferred"
],
"url": "https://security.netapp.com/advisory/ntap-20211210-0007/"
},
{
"tags": [
"x_transferred"
],
"url": "http://packetstormsecurity.com/files/165225/Apache-Log4j2-2.14.1-Remote-Code-Execution.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0032"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.oracle.com/security-alerts/alert-cve-2021-44228.html"
},
{
"name": "DSA-5020",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.debian.org/security/2021/dsa-5020"
},
{
"name": "[debian-lts-announce] 20211212 [SECURITY] [DLA 2842-1] apache-log4j2 security update",
"tags": [
"mailing-list",
"x_transferred"
],
"url": "https://lists.debian.org/debian-lts-announce/2021/12/msg00007.html"
},
{
"name": "FEDORA-2021-f0f501d01f",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/VU57UJDCFIASIO35GC55JMKSRXJMCDFM/"
},
{
"name": "Microsoft\u2019s Response to CVE-2021-44228 Apache Log4j 2",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://msrc-blog.microsoft.com/2021/12/11/microsofts-response-to-cve-2021-44228-apache-log4j2/"
},
{
"name": "[oss-security] 20211213 Re: CVE-2021-4104: Deserialization of untrusted data in JMSAppender in Apache Log4j 1.2",
"tags": [
"mailing-list",
"x_transferred"
],
"url": "http://www.openwall.com/lists/oss-security/2021/12/13/2"
},
{
"name": "[oss-security] 20211213 CVE-2021-4104: Deserialization of untrusted data in JMSAppender in Apache Log4j 1.2",
"tags": [
"mailing-list",
"x_transferred"
],
"url": "http://www.openwall.com/lists/oss-security/2021/12/13/1"
},
{
"name": "[oss-security] 20211214 CVE-2021-45046: Apache Log4j2 Thread Context Message Pattern and Context Lookup Pattern vulnerable to a denial of service attack",
"tags": [
"mailing-list",
"x_transferred"
],
"url": "http://www.openwall.com/lists/oss-security/2021/12/14/4"
},
{
"name": "20211210 A Vulnerability in Apache Log4j Library Affecting Cisco Products: December 2021",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-apache-log4j-qRuKNEbd"
},
{
"name": "VU#930724",
"tags": [
"third-party-advisory",
"x_transferred"
],
"url": "https://www.kb.cert.org/vuls/id/930724"
},
{
"tags": [
"x_transferred"
],
"url": "https://twitter.com/kurtseifried/status/1469345530182455296"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-661247.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "http://packetstormsecurity.com/files/165260/VMware-Security-Advisory-2021-0028.html"
},
{
"tags": [
"x_transferred"
],
"url": "http://packetstormsecurity.com/files/165270/Apache-Log4j2-2.14.1-Remote-Code-Execution.html"
},
{
"tags": [
"x_transferred"
],
"url": "http://packetstormsecurity.com/files/165261/Apache-Log4j2-2.14.1-Information-Disclosure.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00646.html"
},
{
"name": "20211210 Vulnerabilities in Apache Log4j Library Affecting Cisco Products: December 2021",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-apache-log4j-qRuKNEbd"
},
{
"name": "[oss-security] 20211215 Re: CVE-2021-45046: Apache Log4j2 Thread Context Message Pattern and Context Lookup Pattern vulnerable to a denial of service attack",
"tags": [
"mailing-list",
"x_transferred"
],
"url": "http://www.openwall.com/lists/oss-security/2021/12/15/3"
},
{
"tags": [
"x_transferred"
],
"url": "http://packetstormsecurity.com/files/165282/Log4j-Payload-Generator.html"
},
{
"tags": [
"x_transferred"
],
"url": "http://packetstormsecurity.com/files/165281/Log4j2-Log4Shell-Regexes.html"
},
{
"tags": [
"x_transferred"
],
"url": "http://packetstormsecurity.com/files/165307/Log4j-Remote-Code-Execution-Word-Bypassing.html"
},
{
"tags": [
"x_transferred"
],
"url": "http://packetstormsecurity.com/files/165311/log4j-scan-Extensive-Scanner.html"
},
{
"tags": [
"x_transferred"
],
"url": "http://packetstormsecurity.com/files/165306/L4sh-Log4j-Remote-Code-Execution.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-714170.pdf"
},
{
"name": "FEDORA-2021-66d6c484f3",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/M5CSVUNV4HWZZXGOKNSK6L7RPM7BOKIB/"
},
{
"tags": [
"x_transferred"
],
"url": "http://packetstormsecurity.com/files/165371/VMware-Security-Advisory-2021-0028.4.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-397453.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-479842.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.oracle.com/security-alerts/cpujan2022.html"
},
{
"tags": [
"x_transferred"
],
"url": "http://packetstormsecurity.com/files/165532/Log4Shell-HTTP-Header-Injection.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/cisagov/log4j-affected-db/blob/develop/SOFTWARE-LIST.md"
},
{
"tags": [
"x_transferred"
],
"url": "http://packetstormsecurity.com/files/165642/VMware-vCenter-Server-Unauthenticated-Log4Shell-JNDI-Injection-Remote-Code-Execution.html"
},
{
"tags": [
"x_transferred"
],
"url": "http://packetstormsecurity.com/files/165673/UniFi-Network-Application-Unauthenticated-Log4Shell-Remote-Code-Execution.html"
},
{
"name": "20220314 APPLE-SA-2022-03-14-7 Xcode 13.3",
"tags": [
"mailing-list",
"x_transferred"
],
"url": "http://seclists.org/fulldisclosure/2022/Mar/23"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.bentley.com/en/common-vulnerability-exposure/be-2022-0001"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/cisagov/log4j-affected-db"
},
{
"tags": [
"x_transferred"
],
"url": "https://support.apple.com/kb/HT213189"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.oracle.com/security-alerts/cpuapr2022.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/nu11secur1ty/CVE-mitre/tree/main/CVE-2021-44228"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.nu11secur1ty.com/2021/12/cve-2021-44228.html"
},
{
"name": "20220721 Open-Xchange Security Advisory 2022-07-21",
"tags": [
"mailing-list",
"x_transferred"
],
"url": "http://seclists.org/fulldisclosure/2022/Jul/11"
},
{
"tags": [
"x_transferred"
],
"url": "http://packetstormsecurity.com/files/167794/Open-Xchange-App-Suite-7.10.x-Cross-Site-Scripting-Command-Injection.html"
},
{
"tags": [
"x_transferred"
],
"url": "http://packetstormsecurity.com/files/167917/MobileIron-Log4Shell-Remote-Command-Execution.html"
},
{
"name": "20221208 Intel Data Center Manager \u003c= 5.1 Local Privileges Escalation",
"tags": [
"mailing-list",
"x_transferred"
],
"url": "http://seclists.org/fulldisclosure/2022/Dec/2"
},
{
"tags": [
"x_transferred"
],
"url": "http://packetstormsecurity.com/files/171626/AD-Manager-Plus-7122-Remote-Code-Execution.html"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 10,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2021-44228",
"options": [
{
"Exploitation": "active"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-04T14:25:34.416117Z",
"version": "2.0.3"
},
"type": "ssvc"
}
},
{
"other": {
"content": {
"dateAdded": "2021-12-10",
"reference": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2021-44228"
},
"type": "kev"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-10-21T23:25:23.121Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2021-44228"
}
],
"timeline": [
{
"lang": "en",
"time": "2021-12-10T00:00:00.000Z",
"value": "CVE-2021-44228 added to CISA KEV"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Apache Log4j2",
"vendor": "Apache Software Foundation",
"versions": [
{
"changes": [
{
"at": "2.3.1",
"status": "unaffected"
},
{
"at": "2.4",
"status": "affected"
},
{
"at": "2.12.2",
"status": "unaffected"
},
{
"at": "2.13.0",
"status": "affected"
},
{
"at": "2.15.0",
"status": "unaffected"
}
],
"lessThan": "log4j-core*",
"status": "affected",
"version": "2.0-beta9",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "This issue was discovered by Chen Zhaojun of Alibaba Cloud Security Team."
}
],
"descriptions": [
{
"lang": "en",
"value": "Apache Log4j2 2.0-beta9 through 2.15.0 (excluding security releases 2.12.2, 2.12.3, and 2.3.1) JNDI features used in configuration, log messages, and parameters do not protect against attacker controlled LDAP and other JNDI related endpoints. An attacker who can control log messages or log message parameters can execute arbitrary code loaded from LDAP servers when message lookup substitution is enabled. From log4j 2.15.0, this behavior has been disabled by default. From version 2.16.0 (along with 2.12.2, 2.12.3, and 2.3.1), this functionality has been completely removed. Note that this vulnerability is specific to log4j-core and does not affect log4net, log4cxx, or other Apache Logging Services projects."
}
],
"metrics": [
{
"other": {
"content": {
"other": "critical"
},
"type": "unknown"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-502",
"description": "CWE-502 Deserialization of Untrusted Data",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-400",
"description": "CWE-400 Uncontrolled Resource Consumption",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-04-03T00:00:00.000Z",
"orgId": "f0158376-9dc2-43b6-827c-5f631a4d8d09",
"shortName": "apache"
},
"references": [
{
"url": "https://logging.apache.org/log4j/2.x/security.html"
},
{
"name": "[oss-security] 20211210 CVE-2021-44228: Apache Log4j2 JNDI features do not protect against attacker controlled LDAP and other JNDI related endpoints",
"tags": [
"mailing-list"
],
"url": "http://www.openwall.com/lists/oss-security/2021/12/10/1"
},
{
"name": "[oss-security] 20211210 Re: CVE-2021-44228: Apache Log4j2 JNDI features do not protect against attacker controlled LDAP and other JNDI related endpoints",
"tags": [
"mailing-list"
],
"url": "http://www.openwall.com/lists/oss-security/2021/12/10/2"
},
{
"name": "20211210 Vulnerability in Apache Log4j Library Affecting Cisco Products: December 2021",
"tags": [
"vendor-advisory"
],
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-apache-log4j-qRuKNEbd"
},
{
"name": "[oss-security] 20211210 Re: CVE-2021-44228: Apache Log4j2 JNDI features do not protect against attacker controlled LDAP and other JNDI related endpoints",
"tags": [
"mailing-list"
],
"url": "http://www.openwall.com/lists/oss-security/2021/12/10/3"
},
{
"url": "https://security.netapp.com/advisory/ntap-20211210-0007/"
},
{
"url": "http://packetstormsecurity.com/files/165225/Apache-Log4j2-2.14.1-Remote-Code-Execution.html"
},
{
"url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0032"
},
{
"url": "https://www.oracle.com/security-alerts/alert-cve-2021-44228.html"
},
{
"name": "DSA-5020",
"tags": [
"vendor-advisory"
],
"url": "https://www.debian.org/security/2021/dsa-5020"
},
{
"name": "[debian-lts-announce] 20211212 [SECURITY] [DLA 2842-1] apache-log4j2 security update",
"tags": [
"mailing-list"
],
"url": "https://lists.debian.org/debian-lts-announce/2021/12/msg00007.html"
},
{
"name": "FEDORA-2021-f0f501d01f",
"tags": [
"vendor-advisory"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/VU57UJDCFIASIO35GC55JMKSRXJMCDFM/"
},
{
"name": "Microsoft\u2019s Response to CVE-2021-44228 Apache Log4j 2",
"tags": [
"vendor-advisory"
],
"url": "https://msrc-blog.microsoft.com/2021/12/11/microsofts-response-to-cve-2021-44228-apache-log4j2/"
},
{
"name": "[oss-security] 20211213 Re: CVE-2021-4104: Deserialization of untrusted data in JMSAppender in Apache Log4j 1.2",
"tags": [
"mailing-list"
],
"url": "http://www.openwall.com/lists/oss-security/2021/12/13/2"
},
{
"name": "[oss-security] 20211213 CVE-2021-4104: Deserialization of untrusted data in JMSAppender in Apache Log4j 1.2",
"tags": [
"mailing-list"
],
"url": "http://www.openwall.com/lists/oss-security/2021/12/13/1"
},
{
"name": "[oss-security] 20211214 CVE-2021-45046: Apache Log4j2 Thread Context Message Pattern and Context Lookup Pattern vulnerable to a denial of service attack",
"tags": [
"mailing-list"
],
"url": "http://www.openwall.com/lists/oss-security/2021/12/14/4"
},
{
"name": "20211210 A Vulnerability in Apache Log4j Library Affecting Cisco Products: December 2021",
"tags": [
"vendor-advisory"
],
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-apache-log4j-qRuKNEbd"
},
{
"name": "VU#930724",
"tags": [
"third-party-advisory"
],
"url": "https://www.kb.cert.org/vuls/id/930724"
},
{
"url": "https://twitter.com/kurtseifried/status/1469345530182455296"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-661247.pdf"
},
{
"url": "http://packetstormsecurity.com/files/165260/VMware-Security-Advisory-2021-0028.html"
},
{
"url": "http://packetstormsecurity.com/files/165270/Apache-Log4j2-2.14.1-Remote-Code-Execution.html"
},
{
"url": "http://packetstormsecurity.com/files/165261/Apache-Log4j2-2.14.1-Information-Disclosure.html"
},
{
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00646.html"
},
{
"name": "20211210 Vulnerabilities in Apache Log4j Library Affecting Cisco Products: December 2021",
"tags": [
"vendor-advisory"
],
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-apache-log4j-qRuKNEbd"
},
{
"name": "[oss-security] 20211215 Re: CVE-2021-45046: Apache Log4j2 Thread Context Message Pattern and Context Lookup Pattern vulnerable to a denial of service attack",
"tags": [
"mailing-list"
],
"url": "http://www.openwall.com/lists/oss-security/2021/12/15/3"
},
{
"url": "http://packetstormsecurity.com/files/165282/Log4j-Payload-Generator.html"
},
{
"url": "http://packetstormsecurity.com/files/165281/Log4j2-Log4Shell-Regexes.html"
},
{
"url": "http://packetstormsecurity.com/files/165307/Log4j-Remote-Code-Execution-Word-Bypassing.html"
},
{
"url": "http://packetstormsecurity.com/files/165311/log4j-scan-Extensive-Scanner.html"
},
{
"url": "http://packetstormsecurity.com/files/165306/L4sh-Log4j-Remote-Code-Execution.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-714170.pdf"
},
{
"name": "FEDORA-2021-66d6c484f3",
"tags": [
"vendor-advisory"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/M5CSVUNV4HWZZXGOKNSK6L7RPM7BOKIB/"
},
{
"url": "http://packetstormsecurity.com/files/165371/VMware-Security-Advisory-2021-0028.4.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-397453.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-479842.pdf"
},
{
"url": "https://www.oracle.com/security-alerts/cpujan2022.html"
},
{
"url": "http://packetstormsecurity.com/files/165532/Log4Shell-HTTP-Header-Injection.html"
},
{
"url": "https://github.com/cisagov/log4j-affected-db/blob/develop/SOFTWARE-LIST.md"
},
{
"url": "http://packetstormsecurity.com/files/165642/VMware-vCenter-Server-Unauthenticated-Log4Shell-JNDI-Injection-Remote-Code-Execution.html"
},
{
"url": "http://packetstormsecurity.com/files/165673/UniFi-Network-Application-Unauthenticated-Log4Shell-Remote-Code-Execution.html"
},
{
"name": "20220314 APPLE-SA-2022-03-14-7 Xcode 13.3",
"tags": [
"mailing-list"
],
"url": "http://seclists.org/fulldisclosure/2022/Mar/23"
},
{
"url": "https://www.bentley.com/en/common-vulnerability-exposure/be-2022-0001"
},
{
"url": "https://github.com/cisagov/log4j-affected-db"
},
{
"url": "https://support.apple.com/kb/HT213189"
},
{
"url": "https://www.oracle.com/security-alerts/cpuapr2022.html"
},
{
"url": "https://github.com/nu11secur1ty/CVE-mitre/tree/main/CVE-2021-44228"
},
{
"url": "https://www.nu11secur1ty.com/2021/12/cve-2021-44228.html"
},
{
"name": "20220721 Open-Xchange Security Advisory 2022-07-21",
"tags": [
"mailing-list"
],
"url": "http://seclists.org/fulldisclosure/2022/Jul/11"
},
{
"url": "http://packetstormsecurity.com/files/167794/Open-Xchange-App-Suite-7.10.x-Cross-Site-Scripting-Command-Injection.html"
},
{
"url": "http://packetstormsecurity.com/files/167917/MobileIron-Log4Shell-Remote-Command-Execution.html"
},
{
"name": "20221208 Intel Data Center Manager \u003c= 5.1 Local Privileges Escalation",
"tags": [
"mailing-list"
],
"url": "http://seclists.org/fulldisclosure/2022/Dec/2"
},
{
"url": "http://packetstormsecurity.com/files/171626/AD-Manager-Plus-7122-Remote-Code-Execution.html"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Apache Log4j2 JNDI features do not protect against attacker controlled LDAP and other JNDI related endpoints",
"x_generator": {
"engine": "Vulnogram 0.0.9"
}
}
},
"cveMetadata": {
"assignerOrgId": "f0158376-9dc2-43b6-827c-5f631a4d8d09",
"assignerShortName": "apache",
"cveId": "CVE-2021-44228",
"datePublished": "2021-12-10T00:00:00.000Z",
"dateReserved": "2021-11-26T00:00:00.000Z",
"dateUpdated": "2025-10-21T23:25:23.121Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
Loading…
Trend slope:
-
(linear fit over daily sighting counts)
Show additional events:
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…