SSA-928984
Vulnerability from csaf_siemens - Published: 2024-12-16 00:00 - Updated: 2026-01-13 00:00| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Opcenter Execution Foundation
Siemens / Opcenter Execution Foundation
|
vers:intdot/<2501.0001 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
Opcenter Intelligence
Siemens / Opcenter Intelligence
|
vers:intdot/<2501.0001 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
Opcenter Quality
Siemens / Opcenter Quality
|
vers:intdot/<2512 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
Opcenter RDnL
Siemens / Opcenter RDnL
|
vers:intdot/<2410 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
SIMATIC PCS neo V4.0
Siemens / SIMATIC PCS neo V4.0
|
vers:all/* |
Mitigation
Mitigation
No Fix Planned
|
|
|
SIMATIC PCS neo V4.1
Siemens / SIMATIC PCS neo V4.1
|
All versions < V4.1 Update 3 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
SIMATIC PCS neo V5.0
Siemens / SIMATIC PCS neo V5.0
|
All versions < V5.0 Update 1 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
SINEC NMS
Siemens / SINEC NMS
|
vers:all/* |
Mitigation
Mitigation
Vendor Fix
|
|
|
Totally Integrated Automation Portal (TIA Portal) V16
Siemens / Totally Integrated Automation Portal (TIA Portal) V16
|
vers:all/* |
Mitigation
Mitigation
No Fix Planned
|
|
|
Totally Integrated Automation Portal (TIA Portal) V17
Siemens / Totally Integrated Automation Portal (TIA Portal) V17
|
vers:all/* |
Mitigation
Mitigation
Vendor Fix
|
|
|
Totally Integrated Automation Portal (TIA Portal) V18
Siemens / Totally Integrated Automation Portal (TIA Portal) V18
|
vers:all/* |
Mitigation
Mitigation
Vendor Fix
|
|
|
Totally Integrated Automation Portal (TIA Portal) V19
Siemens / Totally Integrated Automation Portal (TIA Portal) V19
|
vers:all/* |
Mitigation
Mitigation
Vendor Fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Desigo ABT
Siemens / Desigo ABT
|
vers:all/* |
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)",
"tlp": {
"label": "WHITE"
}
},
"lang": "en",
"notes": [
{
"category": "summary",
"text": "Siemens User Management Component (UMC) is affected by a heap-based buffer overflow vulnerability which could allow an unauthenticated remote attacker arbitrary code execution.\n\nSiemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where fixes are not, or not yet available.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.",
"title": "Terms of Use"
}
],
"publisher": {
"category": "vendor",
"contact_details": "productcert@siemens.com",
"name": "Siemens ProductCERT",
"namespace": "https://www.siemens.com"
},
"references": [
{
"category": "self",
"summary": "SSA-928984: Heap-based Buffer Overflow Vulnerability in User Management Component (UMC) - HTML Version",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-928984.html"
},
{
"category": "self",
"summary": "SSA-928984: Heap-based Buffer Overflow Vulnerability in User Management Component (UMC) - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-928984.json"
}
],
"title": "SSA-928984: Heap-based Buffer Overflow Vulnerability in User Management Component (UMC)",
"tracking": {
"current_release_date": "2026-01-13T00:00:00Z",
"generator": {
"engine": {
"name": "Siemens ProductCERT CSAF Generator",
"version": "1"
}
},
"id": "SSA-928984",
"initial_release_date": "2024-12-16T00:00:00Z",
"revision_history": [
{
"date": "2024-12-16T00:00:00Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
},
{
"date": "2025-03-11T00:00:00Z",
"legacy_version": "1.1",
"number": "2",
"summary": "Added fix for SIMATIC PCS neo V4.1"
},
{
"date": "2025-05-13T00:00:00Z",
"legacy_version": "1.2",
"number": "3",
"summary": "Added remediation for Totally Integrated Automation Portal (TIA Portal) V17, V18 and V19. Updated remediation for SINEC NMS to point directly to the update of UMC"
},
{
"date": "2025-06-10T00:00:00Z",
"legacy_version": "1.3",
"number": "4",
"summary": "Added fix for Opcenter Execution Foundation, Opcenter Intelligence and Opcenter RDnL"
},
{
"date": "2026-01-13T00:00:00Z",
"legacy_version": "1.4",
"number": "5",
"summary": "Added fix for Opcenter Quality"
}
],
"status": "interim",
"version": "5"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Desigo ABT",
"product_id": "1"
}
}
],
"category": "product_name",
"name": "Desigo ABT"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c2501.0001",
"product": {
"name": "Opcenter Execution Foundation",
"product_id": "2"
}
}
],
"category": "product_name",
"name": "Opcenter Execution Foundation"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c2501.0001",
"product": {
"name": "Opcenter Intelligence",
"product_id": "3"
}
}
],
"category": "product_name",
"name": "Opcenter Intelligence"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c2512",
"product": {
"name": "Opcenter Quality",
"product_id": "4"
}
}
],
"category": "product_name",
"name": "Opcenter Quality"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c2410",
"product": {
"name": "Opcenter RDnL",
"product_id": "5"
}
}
],
"category": "product_name",
"name": "Opcenter RDnL"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC PCS neo V4.0",
"product_id": "6"
}
}
],
"category": "product_name",
"name": "SIMATIC PCS neo V4.0"
},
{
"branches": [
{
"category": "product_version_range",
"name": "All versions \u003c V4.1 Update 3",
"product": {
"name": "SIMATIC PCS neo V4.1",
"product_id": "7"
}
}
],
"category": "product_name",
"name": "SIMATIC PCS neo V4.1"
},
{
"branches": [
{
"category": "product_version_range",
"name": "All versions \u003c V5.0 Update 1",
"product": {
"name": "SIMATIC PCS neo V5.0",
"product_id": "8"
}
}
],
"category": "product_name",
"name": "SIMATIC PCS neo V5.0"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SINEC NMS",
"product_id": "9"
}
}
],
"category": "product_name",
"name": "SINEC NMS"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Totally Integrated Automation Portal (TIA Portal) V16",
"product_id": "10"
}
}
],
"category": "product_name",
"name": "Totally Integrated Automation Portal (TIA Portal) V16"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Totally Integrated Automation Portal (TIA Portal) V17",
"product_id": "11"
}
}
],
"category": "product_name",
"name": "Totally Integrated Automation Portal (TIA Portal) V17"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Totally Integrated Automation Portal (TIA Portal) V18",
"product_id": "12"
}
}
],
"category": "product_name",
"name": "Totally Integrated Automation Portal (TIA Portal) V18"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Totally Integrated Automation Portal (TIA Portal) V19",
"product_id": "13"
}
}
],
"category": "product_name",
"name": "Totally Integrated Automation Portal (TIA Portal) V19"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2024-49775",
"cwe": {
"id": "CWE-122",
"name": "Heap-based Buffer Overflow"
},
"flags": [
{
"label": "component_not_present",
"product_ids": [
"1"
]
}
],
"notes": [
{
"category": "summary",
"text": "Affected products contain a heap-based buffer overflow vulnerability in the integrated UMC component.\r\nThis could allow an unauthenticated remote attacker to execute arbitrary code.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13"
],
"known_not_affected": [
"1"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Filter the ports 4002 and 4004 to only accept connections to/from the IP addresses of machines that run UMC and are part of the UMC network e.g. with an external firewall",
"product_ids": [
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13"
]
},
{
"category": "mitigation",
"details": "In addition if no RT server machines are used, port 4004 can be blocked completely",
"product_ids": [
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"6",
"10"
]
},
{
"category": "vendor_fix",
"details": "Update to V2410 or later version",
"product_ids": [
"5"
],
"url": "https://support.sw.siemens.com/product/297341591/"
},
{
"category": "vendor_fix",
"details": "Update to V2501.0001 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/product/219646572/"
},
{
"category": "vendor_fix",
"details": "Update to V2501.0001 or later version",
"product_ids": [
"3"
],
"url": "https://support.sw.siemens.com/product/287414453/"
},
{
"category": "vendor_fix",
"details": "Update to V2512 or later version",
"product_ids": [
"4"
],
"url": "https://support.sw.siemens.com/product/249261320"
},
{
"category": "vendor_fix",
"details": "Update to V4.1 Update 3 or later version",
"product_ids": [
"7"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109978820/"
},
{
"category": "vendor_fix",
"details": "Update to V5.0 Update 1 or later version",
"product_ids": [
"8"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109977244/"
},
{
"category": "vendor_fix",
"details": "Update UMC to V2.15.1.1 or later compatible version https://support.industry.siemens.com/cs/ww/en/view/109987708/",
"product_ids": [
"9",
"11",
"12",
"13"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13"
]
}
],
"threats": [
{
"category": "impact",
"details": "While TIA Portal is included as part of the ABT Site installation, neither ABT itself nor the incorporated TIA version uses or installs the affected User Management Component (UMC). As a result, any standalone ABT installation remains unaffected by this issue.",
"product_ids": [
"1"
]
}
],
"title": "CVE-2024-49775"
}
]
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.