SSA-626856
Vulnerability from csaf_siemens - Published: 2025-12-09 00:00 - Updated: 2025-12-09 00:00{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)",
"tlp": {
"label": "WHITE"
}
},
"lang": "en",
"notes": [
{
"category": "summary",
"text": "SINEMA Remote Connect Server Before V3.2 SP4 is affected by multiple vulnerabilities.\n\nSiemens has released a new version for SINEMA Remote Connect Server and recommends to update to the latest version.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.",
"title": "Terms of Use"
}
],
"publisher": {
"category": "vendor",
"contact_details": "productcert@siemens.com",
"name": "Siemens ProductCERT",
"namespace": "https://www.siemens.com"
},
"references": [
{
"category": "self",
"summary": "SSA-626856: Multiple Vulnerabilities in SINEMA Remote Connect Sever Before V3.2 SP4 - HTML Version",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-626856.html"
},
{
"category": "self",
"summary": "SSA-626856: Multiple Vulnerabilities in SINEMA Remote Connect Sever Before V3.2 SP4 - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-626856.json"
}
],
"title": "SSA-626856: Multiple Vulnerabilities in SINEMA Remote Connect Sever Before V3.2 SP4",
"tracking": {
"current_release_date": "2025-12-09T00:00:00Z",
"generator": {
"engine": {
"name": "Siemens ProductCERT CSAF Generator",
"version": "1"
}
},
"id": "SSA-626856",
"initial_release_date": "2025-12-09T00:00:00Z",
"revision_history": [
{
"date": "2025-12-09T00:00:00Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
}
],
"status": "interim",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "All versions \u003c V3.2 SP4",
"product": {
"name": "SINEMA Remote Connect Server",
"product_id": "1"
}
}
],
"category": "product_name",
"name": "SINEMA Remote Connect Server"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2025-40818",
"cwe": {
"id": "CWE-732",
"name": "Incorrect Permission Assignment for Critical Resource"
},
"notes": [
{
"category": "summary",
"text": "Affected applications contain private SSL/TLS keys on the server that are not properly protected allowing any user with server access to read these keys. This could allow an authenticated attacker to impersonate the server potentially enabling man-in-the-middle, traffic decryption or unauthorized access to services that trust these certificates.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V3.2 SP4 or later version",
"product_ids": [
"1"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109995084/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 3.3,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
},
"products": [
"1"
]
}
],
"title": "CVE-2025-40818"
},
{
"cve": "CVE-2025-40819",
"cwe": {
"id": "CWE-863",
"name": "Incorrect Authorization"
},
"notes": [
{
"category": "summary",
"text": "Affected applications do not properly validate license restrictions against the database, allowing direct modification of the system_ticketinfo table to bypass license limitations without proper enforcement checks. This could allow with database access to circumvent licensing restrictions by directly modifying database values and potentially enabling unauthorized use beyond the permitted scope.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V3.2 SP4 or later version",
"product_ids": [
"1"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109995084/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N",
"version": "3.1"
},
"products": [
"1"
]
}
],
"title": "CVE-2025-40819"
}
]
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.