SSA-506569
Vulnerability from csaf_siemens - Published: 2022-11-08 00:00 - Updated: 2023-02-14 00:00| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE W1750D (JP) (6GK5750-2HX01-1AD0)
Siemens / SCALANCE W1750D (JP) (6GK5750-2HX01-1AD0)
|
6GK5750-2HX01-1AD0
|
< V8.7.1.11 |
Vendor Fix
fix
|
|
SCALANCE W1750D (ROW) (6GK5750-2HX01-1AA0)
Siemens / SCALANCE W1750D (ROW) (6GK5750-2HX01-1AA0)
|
6GK5750-2HX01-1AA0
|
< V8.7.1.11 |
Vendor Fix
fix
|
|
SCALANCE W1750D (USA) (6GK5750-2HX01-1AB0)
Siemens / SCALANCE W1750D (USA) (6GK5750-2HX01-1AB0)
|
6GK5750-2HX01-1AB0
|
< V8.7.1.11 |
Vendor Fix
fix
|
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)",
"tlp": {
"label": "WHITE"
}
},
"notes": [
{
"category": "summary",
"text": "The SCALANCE W1750D device contains multiple vulnerabilities that could allow an attacker to inject commands or exploit buffer overflow vulnerabilities which could lead to denial of service, unauthenticated remote code execution or stored XSS.\n\nSiemens has released updates for the affected products and recommends to update to the latest versions.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
"title": "Terms of Use"
}
],
"publisher": {
"category": "vendor",
"contact_details": "productcert@siemens.com",
"name": "Siemens ProductCERT",
"namespace": "https://www.siemens.com"
},
"references": [
{
"category": "self",
"summary": "SSA-506569: Multiple Vulnerabilities in SCALANCE W1750D - PDF Version",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-506569.pdf"
},
{
"category": "self",
"summary": "SSA-506569: Multiple Vulnerabilities in SCALANCE W1750D - TXT Version",
"url": "https://cert-portal.siemens.com/productcert/txt/ssa-506569.txt"
},
{
"category": "self",
"summary": "SSA-506569: Multiple Vulnerabilities in SCALANCE W1750D - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-506569.json"
}
],
"title": "SSA-506569: Multiple Vulnerabilities in SCALANCE W1750D",
"tracking": {
"current_release_date": "2023-02-14T00:00:00Z",
"generator": {
"engine": {
"name": "Siemens ProductCERT CSAF Generator",
"version": "1"
}
},
"id": "SSA-506569",
"initial_release_date": "2022-11-08T00:00:00Z",
"revision_history": [
{
"date": "2022-11-08T00:00:00Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
},
{
"date": "2023-02-14T00:00:00Z",
"legacy_version": "1.1",
"number": "2",
"summary": "Added fix for SCALANCE W1750D"
}
],
"status": "final",
"version": "2"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V8.7.1.11",
"product": {
"name": "SCALANCE W1750D (JP) (6GK5750-2HX01-1AD0)",
"product_id": "1",
"product_identification_helper": {
"model_numbers": [
"6GK5750-2HX01-1AD0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W1750D (JP) (6GK5750-2HX01-1AD0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V8.7.1.11",
"product": {
"name": "SCALANCE W1750D (ROW) (6GK5750-2HX01-1AA0)",
"product_id": "2",
"product_identification_helper": {
"model_numbers": [
"6GK5750-2HX01-1AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W1750D (ROW) (6GK5750-2HX01-1AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V8.7.1.11",
"product": {
"name": "SCALANCE W1750D (USA) (6GK5750-2HX01-1AB0)",
"product_id": "3",
"product_identification_helper": {
"model_numbers": [
"6GK5750-2HX01-1AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W1750D (USA) (6GK5750-2HX01-1AB0)"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2002-20001",
"cwe": {
"id": "CWE-400",
"name": "Uncontrolled Resource Consumption"
},
"notes": [
{
"category": "summary",
"text": "The Diffie-Hellman Key Agreement Protocol allows remote attackers (from the client side) to send arbitrary numbers that are actually not public keys, and trigger expensive server-side DHE modular-exponentiation calculations, aka a D(HE)ater attack. The client needs very little CPU resources and network bandwidth. The attack may be more disruptive in cases where a client can require a server to select its largest supported key size. The basic attack scenario is that the client must claim that it can only communicate with DHE, and the server must be configured to allow DHE. (ATLWL-266)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V8.7.1.11 or later version",
"product_ids": [
"1",
"2",
"3"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109816886/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:T/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3"
]
}
],
"title": "CVE-2002-20001"
},
{
"cve": "CVE-2022-37885",
"cwe": {
"id": "CWE-120",
"name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)"
},
"notes": [
{
"category": "summary",
"text": "A buffer overflow vulnerability in an underlying service could lead to unauthenticated remote code execution by sending specially crafted packets destined to the PAPI UDP port (8211). (ATLWL-253)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "CVE-2022-37885, CVE-2022-37886, CVE-2022-37887, CVE-2022-37888, CVE-2022-37889: Enable CPSec via the cluster-security command",
"product_ids": [
"1",
"2",
"3"
]
},
{
"category": "vendor_fix",
"details": "Update to V8.7.1.11 or later version",
"product_ids": [
"1",
"2",
"3"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109816886/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:T/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3"
]
}
],
"title": "CVE-2022-37885"
},
{
"cve": "CVE-2022-37886",
"cwe": {
"id": "CWE-120",
"name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)"
},
"notes": [
{
"category": "summary",
"text": "A buffer overflow vulnerability in an underlying service could lead to unauthenticated remote code execution by sending specially crafted packets destined to the PAPI UDP port (8211). (ATLWL-254)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "CVE-2022-37885, CVE-2022-37886, CVE-2022-37887, CVE-2022-37888, CVE-2022-37889: Enable CPSec via the cluster-security command",
"product_ids": [
"1",
"2",
"3"
]
},
{
"category": "vendor_fix",
"details": "Update to V8.7.1.11 or later version",
"product_ids": [
"1",
"2",
"3"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109816886/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:T/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3"
]
}
],
"title": "CVE-2022-37886"
},
{
"cve": "CVE-2022-37887",
"cwe": {
"id": "CWE-120",
"name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)"
},
"notes": [
{
"category": "summary",
"text": "A buffer overflow vulnerability in an underlying service could lead to unauthenticated remote code execution by sending specially crafted packets destined to the PAPI UDP port (8211). (ATLWL-299)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "CVE-2022-37885, CVE-2022-37886, CVE-2022-37887, CVE-2022-37888, CVE-2022-37889: Enable CPSec via the cluster-security command",
"product_ids": [
"1",
"2",
"3"
]
},
{
"category": "vendor_fix",
"details": "Update to V8.7.1.11 or later version",
"product_ids": [
"1",
"2",
"3"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109816886/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:T/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3"
]
}
],
"title": "CVE-2022-37887"
},
{
"cve": "CVE-2022-37888",
"cwe": {
"id": "CWE-120",
"name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)"
},
"notes": [
{
"category": "summary",
"text": "A buffer overflow vulnerability in an underlying service could lead to unauthenticated remote code execution by sending specially crafted packets destined to the PAPI UDP port (8211). (ATLWL-300)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "CVE-2022-37885, CVE-2022-37886, CVE-2022-37887, CVE-2022-37888, CVE-2022-37889: Enable CPSec via the cluster-security command",
"product_ids": [
"1",
"2",
"3"
]
},
{
"category": "vendor_fix",
"details": "Update to V8.7.1.11 or later version",
"product_ids": [
"1",
"2",
"3"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109816886/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:T/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3"
]
}
],
"title": "CVE-2022-37888"
},
{
"cve": "CVE-2022-37889",
"cwe": {
"id": "CWE-120",
"name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)"
},
"notes": [
{
"category": "summary",
"text": "A buffer overflow vulnerability in an underlying service could lead to unauthenticated remote code execution by sending specially crafted packets destined to the PAPI UDP port (8211). (ATLWL-302)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "CVE-2022-37885, CVE-2022-37886, CVE-2022-37887, CVE-2022-37888, CVE-2022-37889: Enable CPSec via the cluster-security command",
"product_ids": [
"1",
"2",
"3"
]
},
{
"category": "vendor_fix",
"details": "Update to V8.7.1.11 or later version",
"product_ids": [
"1",
"2",
"3"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109816886/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:T/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3"
]
}
],
"title": "CVE-2022-37889"
},
{
"cve": "CVE-2022-37890",
"cwe": {
"id": "CWE-120",
"name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)"
},
"notes": [
{
"category": "summary",
"text": "An unauthenticated buffer overflow vulnerability exists within the web management interface. Successful exploitation results in the execution of arbitrary commands on the underlying operating system. (ATLWL-102)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "CVE-2022-37890, CVE-2022-37891, CVE-2022-37892, CVE-2022-37895, CVE-2022-37896: Restrict the web-based management interface to a dedicated layer 2 segment/VLAN and/or control the interface by firewall policies at layer 3 and above",
"product_ids": [
"1",
"2",
"3"
]
},
{
"category": "vendor_fix",
"details": "Update to V8.7.1.11 or later version",
"product_ids": [
"1",
"2",
"3"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109816886/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:T/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3"
]
}
],
"title": "CVE-2022-37890"
},
{
"cve": "CVE-2022-37891",
"cwe": {
"id": "CWE-120",
"name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)"
},
"notes": [
{
"category": "summary",
"text": "An unauthenticated buffer overflow vulnerability exists within the web management interface. Successful exploitation results in the execution of arbitrary commands on the underlying operating system. (ATLWL-268)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "CVE-2022-37890, CVE-2022-37891, CVE-2022-37892, CVE-2022-37895, CVE-2022-37896: Restrict the web-based management interface to a dedicated layer 2 segment/VLAN and/or control the interface by firewall policies at layer 3 and above",
"product_ids": [
"1",
"2",
"3"
]
},
{
"category": "vendor_fix",
"details": "Update to V8.7.1.11 or later version",
"product_ids": [
"1",
"2",
"3"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109816886/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:T/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3"
]
}
],
"title": "CVE-2022-37891"
},
{
"cve": "CVE-2022-37892",
"cwe": {
"id": "CWE-79",
"name": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)"
},
"notes": [
{
"category": "summary",
"text": "A vulnerability in the web management interface could allow an unauthenticated remote attacker to conduct a stored cross-site scripting (XSS) attack against a user of the interface. A successful exploit could allow an attacker to execute arbitrary script code in a victim\u2019s browser in the context of the affected interface. (ATLWL-168)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "CVE-2022-37890, CVE-2022-37891, CVE-2022-37892, CVE-2022-37895, CVE-2022-37896: Restrict the web-based management interface to a dedicated layer 2 segment/VLAN and/or control the interface by firewall policies at layer 3 and above",
"product_ids": [
"1",
"2",
"3"
]
},
{
"category": "vendor_fix",
"details": "Update to V8.7.1.11 or later version",
"product_ids": [
"1",
"2",
"3"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109816886/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N/E:P/RL:T/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3"
]
}
],
"title": "CVE-2022-37892"
},
{
"cve": "CVE-2022-37893",
"cwe": {
"id": "CWE-77",
"name": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)"
},
"notes": [
{
"category": "summary",
"text": "An authenticated command injection vulnerability exists in the command line interface. Successful exploitation of this vulnerability results in the ability to execute arbitrary commands as a privileged user on the underlying operating system. (ATLWL-97)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "CVE-2022-37893: Restrict the command line interface to a dedicated layer 2 segment/VLAN and/or control the interface by firewall policies at layer 3 and above",
"product_ids": [
"1",
"2",
"3"
]
},
{
"category": "vendor_fix",
"details": "Update to V8.7.1.11 or later version",
"product_ids": [
"1",
"2",
"3"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109816886/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:T/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3"
]
}
],
"title": "CVE-2022-37893"
},
{
"cve": "CVE-2022-37894",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"category": "summary",
"text": "An unauthenticated denial of service (DoS) vulnerability exists in the handling of certain SSID strings. Successful exploitation of this vulnerability results in the ability to interrupt the normal operation of the affected Access Point. (ATLWL-242)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V8.7.1.11 or later version",
"product_ids": [
"1",
"2",
"3"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109816886/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:T/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3"
]
}
],
"title": "CVE-2022-37894"
},
{
"cve": "CVE-2022-37895",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"category": "summary",
"text": "An authenticated denial of service (DoS) vulnerability exists in the web management interface. Successful exploitation of this vulnerability results in the ability to interrupt the normal operation of the affected Access Point. (ATLWL-248)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "CVE-2022-37890, CVE-2022-37891, CVE-2022-37892, CVE-2022-37895, CVE-2022-37896: Restrict the web-based management interface to a dedicated layer 2 segment/VLAN and/or control the interface by firewall policies at layer 3 and above",
"product_ids": [
"1",
"2",
"3"
]
},
{
"category": "vendor_fix",
"details": "Update to V8.7.1.11 or later version",
"product_ids": [
"1",
"2",
"3"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109816886/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 4.9,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H/E:P/RL:T/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3"
]
}
],
"title": "CVE-2022-37895"
},
{
"cve": "CVE-2022-37896",
"cwe": {
"id": "CWE-79",
"name": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)"
},
"notes": [
{
"category": "summary",
"text": "A vulnerability in the web management interface could allow a remote attacker to conduct a reflected cross-site scripting (XSS) attack against a user of the interface. A successful exploit could allow an attacker to execute arbitrary script code in a victim\u2019s browser in the context of the affected interface. (ATLWL-234)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "CVE-2022-37890, CVE-2022-37891, CVE-2022-37892, CVE-2022-37895, CVE-2022-37896: Restrict the web-based management interface to a dedicated layer 2 segment/VLAN and/or control the interface by firewall policies at layer 3 and above",
"product_ids": [
"1",
"2",
"3"
]
},
{
"category": "vendor_fix",
"details": "Update to V8.7.1.11 or later version",
"product_ids": [
"1",
"2",
"3"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109816886/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N/E:P/RL:T/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3"
]
}
],
"title": "CVE-2022-37896"
}
]
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.