SSA-479249
Vulnerability from csaf_siemens - Published: 2023-04-11 00:00 - Updated: 2023-04-11 00:00| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE X200-4P IRT (6GK5200-4AH00-2BA3)
Siemens / SCALANCE X200-4P IRT (6GK5200-4AH00-2BA3)
|
6GK5200-4AH00-2BA3
|
vers:all/<V5.5.2 |
Vendor Fix
fix
Workaround
Workaround
|
|
SCALANCE X201-3P IRT (6GK5201-3BH00-2BA3)
Siemens / SCALANCE X201-3P IRT (6GK5201-3BH00-2BA3)
|
6GK5201-3BH00-2BA3
|
vers:all/<V5.5.2 |
Vendor Fix
fix
Workaround
Workaround
|
|
SCALANCE X201-3P IRT PRO (6GK5201-3JR00-2BA6)
Siemens / SCALANCE X201-3P IRT PRO (6GK5201-3JR00-2BA6)
|
6GK5201-3JR00-2BA6
|
vers:all/<V5.5.2 |
Vendor Fix
fix
Workaround
Workaround
|
|
SCALANCE X202-2IRT (6GK5202-2BB00-2BA3)
Siemens / SCALANCE X202-2IRT (6GK5202-2BB00-2BA3)
|
6GK5202-2BB00-2BA3
|
vers:all/<V5.5.2 |
Vendor Fix
fix
Workaround
Workaround
|
|
SCALANCE X202-2IRT (6GK5202-2BB10-2BA3)
Siemens / SCALANCE X202-2IRT (6GK5202-2BB10-2BA3)
|
6GK5202-2BB10-2BA3
|
vers:all/<V5.5.2 |
Vendor Fix
fix
Workaround
Workaround
|
|
SCALANCE X202-2P IRT (6GK5202-2BH00-2BA3)
Siemens / SCALANCE X202-2P IRT (6GK5202-2BH00-2BA3)
|
6GK5202-2BH00-2BA3
|
vers:all/<V5.5.2 |
Vendor Fix
fix
Workaround
Workaround
|
|
SCALANCE X202-2P IRT PRO (6GK5202-2JR00-2BA6)
Siemens / SCALANCE X202-2P IRT PRO (6GK5202-2JR00-2BA6)
|
6GK5202-2JR00-2BA6
|
vers:all/<V5.5.2 |
Vendor Fix
fix
Workaround
Workaround
|
|
SCALANCE X204IRT (6GK5204-0BA00-2BA3)
Siemens / SCALANCE X204IRT (6GK5204-0BA00-2BA3)
|
6GK5204-0BA00-2BA3
|
vers:all/<V5.5.2 |
Vendor Fix
fix
Workaround
Workaround
|
|
SCALANCE X204IRT (6GK5204-0BA10-2BA3)
Siemens / SCALANCE X204IRT (6GK5204-0BA10-2BA3)
|
6GK5204-0BA10-2BA3
|
vers:all/<V5.5.2 |
Vendor Fix
fix
Workaround
Workaround
|
|
SCALANCE X204IRT PRO (6GK5204-0JA00-2BA6)
Siemens / SCALANCE X204IRT PRO (6GK5204-0JA00-2BA6)
|
6GK5204-0JA00-2BA6
|
vers:all/<V5.5.2 |
Vendor Fix
fix
Workaround
Workaround
|
|
SCALANCE XF201-3P IRT (6GK5201-3BH00-2BD2)
Siemens / SCALANCE XF201-3P IRT (6GK5201-3BH00-2BD2)
|
6GK5201-3BH00-2BD2
|
vers:all/<V5.5.2 |
Vendor Fix
fix
Workaround
Workaround
|
|
SCALANCE XF202-2P IRT (6GK5202-2BH00-2BD2)
Siemens / SCALANCE XF202-2P IRT (6GK5202-2BH00-2BD2)
|
6GK5202-2BH00-2BD2
|
vers:all/<V5.5.2 |
Vendor Fix
fix
Workaround
Workaround
|
|
SCALANCE XF204-2BA IRT (6GK5204-2AA00-2BD2)
Siemens / SCALANCE XF204-2BA IRT (6GK5204-2AA00-2BD2)
|
6GK5204-2AA00-2BD2
|
vers:all/<V5.5.2 |
Vendor Fix
fix
Workaround
Workaround
|
|
SCALANCE XF204IRT (6GK5204-0BA00-2BF2)
Siemens / SCALANCE XF204IRT (6GK5204-0BA00-2BF2)
|
6GK5204-0BA00-2BF2
|
vers:all/<V5.5.2 |
Vendor Fix
fix
Workaround
Workaround
|
|
SIPLUS NET SCALANCE X202-2P IRT (6AG1202-2BH00-2BA3)
Siemens / SIPLUS NET SCALANCE X202-2P IRT (6AG1202-2BH00-2BA3)
|
6AG1202-2BH00-2BA3
|
vers:all/<V5.5.2 |
Vendor Fix
fix
Workaround
Workaround
|
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)",
"tlp": {
"label": "WHITE"
}
},
"lang": "en",
"notes": [
{
"category": "summary",
"text": "The SSH server on SCALANCE X-200IRT devices is configured to offer weak ciphers by default. This could\nallow an unauthorized attacker in a man-in-the-middle position to read and modify any data passed over\nthe connection between legitimate clients and the affected device.\n\nSiemens has released updates for the affected products and recommends to update to the latest versions.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
"title": "Terms of Use"
}
],
"publisher": {
"category": "vendor",
"contact_details": "productcert@siemens.com",
"name": "Siemens ProductCERT",
"namespace": "https://www.siemens.com"
},
"references": [
{
"category": "self",
"summary": "SSA-479249: Weak Encryption Vulnerability in SCALANCE X-200IRT Devices - HTML Version",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-479249.html"
},
{
"category": "self",
"summary": "SSA-479249: Weak Encryption Vulnerability in SCALANCE X-200IRT Devices - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-479249.json"
},
{
"category": "self",
"summary": "SSA-479249: Weak Encryption Vulnerability in SCALANCE X-200IRT Devices - PDF Version",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-479249.pdf"
},
{
"category": "self",
"summary": "SSA-479249: Weak Encryption Vulnerability in SCALANCE X-200IRT Devices - TXT Version",
"url": "https://cert-portal.siemens.com/productcert/txt/ssa-479249.txt"
}
],
"title": "SSA-479249: Weak Encryption Vulnerability in SCALANCE X-200IRT Devices",
"tracking": {
"current_release_date": "2023-04-11T00:00:00Z",
"generator": {
"engine": {
"name": "Siemens ProductCERT CSAF Generator",
"version": "1"
}
},
"id": "SSA-479249",
"initial_release_date": "2023-04-11T00:00:00Z",
"revision_history": [
{
"date": "2023-04-11T00:00:00Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication date"
}
],
"status": "interim",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV5.5.2",
"product": {
"name": "SCALANCE X200-4P IRT (6GK5200-4AH00-2BA3)",
"product_id": "1",
"product_identification_helper": {
"model_numbers": [
"6GK5200-4AH00-2BA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X200-4P IRT (6GK5200-4AH00-2BA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV5.5.2",
"product": {
"name": "SCALANCE X201-3P IRT (6GK5201-3BH00-2BA3)",
"product_id": "2",
"product_identification_helper": {
"model_numbers": [
"6GK5201-3BH00-2BA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X201-3P IRT (6GK5201-3BH00-2BA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV5.5.2",
"product": {
"name": "SCALANCE X201-3P IRT PRO (6GK5201-3JR00-2BA6)",
"product_id": "3",
"product_identification_helper": {
"model_numbers": [
"6GK5201-3JR00-2BA6"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X201-3P IRT PRO (6GK5201-3JR00-2BA6)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV5.5.2",
"product": {
"name": "SCALANCE X202-2IRT (6GK5202-2BB00-2BA3)",
"product_id": "4",
"product_identification_helper": {
"model_numbers": [
"6GK5202-2BB00-2BA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X202-2IRT (6GK5202-2BB00-2BA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV5.5.2",
"product": {
"name": "SCALANCE X202-2IRT (6GK5202-2BB10-2BA3)",
"product_id": "5",
"product_identification_helper": {
"model_numbers": [
"6GK5202-2BB10-2BA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X202-2IRT (6GK5202-2BB10-2BA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV5.5.2",
"product": {
"name": "SCALANCE X202-2P IRT (6GK5202-2BH00-2BA3)",
"product_id": "6",
"product_identification_helper": {
"model_numbers": [
"6GK5202-2BH00-2BA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X202-2P IRT (6GK5202-2BH00-2BA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV5.5.2",
"product": {
"name": "SCALANCE X202-2P IRT PRO (6GK5202-2JR00-2BA6)",
"product_id": "7",
"product_identification_helper": {
"model_numbers": [
"6GK5202-2JR00-2BA6"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X202-2P IRT PRO (6GK5202-2JR00-2BA6)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV5.5.2",
"product": {
"name": "SCALANCE X204IRT (6GK5204-0BA00-2BA3)",
"product_id": "8",
"product_identification_helper": {
"model_numbers": [
"6GK5204-0BA00-2BA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X204IRT (6GK5204-0BA00-2BA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV5.5.2",
"product": {
"name": "SCALANCE X204IRT (6GK5204-0BA10-2BA3)",
"product_id": "9",
"product_identification_helper": {
"model_numbers": [
"6GK5204-0BA10-2BA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X204IRT (6GK5204-0BA10-2BA3)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV5.5.2",
"product": {
"name": "SCALANCE X204IRT PRO (6GK5204-0JA00-2BA6)",
"product_id": "10",
"product_identification_helper": {
"model_numbers": [
"6GK5204-0JA00-2BA6"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X204IRT PRO (6GK5204-0JA00-2BA6)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV5.5.2",
"product": {
"name": "SCALANCE XF201-3P IRT (6GK5201-3BH00-2BD2)",
"product_id": "11",
"product_identification_helper": {
"model_numbers": [
"6GK5201-3BH00-2BD2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XF201-3P IRT (6GK5201-3BH00-2BD2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV5.5.2",
"product": {
"name": "SCALANCE XF202-2P IRT (6GK5202-2BH00-2BD2)",
"product_id": "12",
"product_identification_helper": {
"model_numbers": [
"6GK5202-2BH00-2BD2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XF202-2P IRT (6GK5202-2BH00-2BD2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV5.5.2",
"product": {
"name": "SCALANCE XF204-2BA IRT (6GK5204-2AA00-2BD2)",
"product_id": "13",
"product_identification_helper": {
"model_numbers": [
"6GK5204-2AA00-2BD2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XF204-2BA IRT (6GK5204-2AA00-2BD2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV5.5.2",
"product": {
"name": "SCALANCE XF204IRT (6GK5204-0BA00-2BF2)",
"product_id": "14",
"product_identification_helper": {
"model_numbers": [
"6GK5204-0BA00-2BF2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE XF204IRT (6GK5204-0BA00-2BF2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV5.5.2",
"product": {
"name": "SIPLUS NET SCALANCE X202-2P IRT (6AG1202-2BH00-2BA3)",
"product_id": "15",
"product_identification_helper": {
"model_numbers": [
"6AG1202-2BH00-2BA3"
]
}
}
}
],
"category": "product_name",
"name": "SIPLUS NET SCALANCE X202-2P IRT (6AG1202-2BH00-2BA3)"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2023-29054",
"cwe": {
"id": "CWE-326",
"name": "Inadequate Encryption Strength"
},
"notes": [
{
"category": "summary",
"text": "The SSH server on affected devices is configured to offer weak ciphers by default.\r\n\r\nThis could allow an unauthorized attacker in a man-in-the-middle position to read and modify any data\r\npassed over the connection between legitimate clients and the affected device.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V5.5.2 or later version",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109817790/"
},
{
"category": "workaround",
"details": "Configure the SSH clients to make use of the following strong key exchange ciphers",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15"
]
},
{
"category": "workaround",
"details": "Add only trusted SSH client public keys to ROS and allow access to those clients only",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.7,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:R/S:U/C:L/I:H/A:H/E:P/RL:U/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15"
]
}
],
"title": "CVE-2023-29054"
}
]
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.