SSA-100232
Vulnerability from csaf_siemens - Published: 2019-08-13 00:00 - Updated: 2022-02-08 00:00| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SCALANCE X204RNA (HSR) (6GK5204-0BA00-2MB2)
Siemens / SCALANCE X204RNA (HSR)
|
6GK5204-0BA00-2MB2
|
vers:all/* |
No Fix Planned
Mitigation
Mitigation
|
|
SCALANCE X204RNA (PRP) (6GK5204-0BA00-2KB2)
Siemens / SCALANCE X204RNA (PRP)
|
6GK5204-0BA00-2KB2
|
vers:all/* |
No Fix Planned
Mitigation
Mitigation
|
|
SCALANCE X204RNA EEC (HSR) (6GK5204-0BS00-2NA3)
Siemens / SCALANCE X204RNA EEC (HSR)
|
6GK5204-0BS00-2NA3
|
vers:all/* |
No Fix Planned
Mitigation
Mitigation
|
|
SCALANCE X204RNA EEC (PRP) (6GK5204-0BS00-3LA3)
Siemens / SCALANCE X204RNA EEC (PRP)
|
6GK5204-0BS00-3LA3
|
vers:all/* |
No Fix Planned
Mitigation
Mitigation
|
|
SCALANCE X204RNA EEC (PRP/HSR) (6GK5204-0BS00-3PA3)
Siemens / SCALANCE X204RNA EEC (PRP/HSR)
|
6GK5204-0BS00-3PA3
|
vers:all/* |
No Fix Planned
Mitigation
Mitigation
|
|
SCALANCE X-200 switch family (incl. SIPLUS NET variants)
Siemens / SCALANCE X-200 switch family (incl. SIPLUS NET variants)
|
< V5.2.5 |
Vendor Fix
fix
Mitigation
Mitigation
|
|
|
SCALANCE X-200IRT switch family (incl. SIPLUS NET variants)
Siemens / SCALANCE X-200IRT switch family (incl. SIPLUS NET variants)
|
< V5.5.0 |
Vendor Fix
fix
Mitigation
Mitigation
|
{
"document": {
"acknowledgments": [
{
"names": [
"Artem Zinenko"
],
"organization": "Kaspersky",
"summary": "pointing out that SIPLUS should also be mentioned"
},
{
"names": [
"Younes Dragoni",
"Alessandro Di Pinto"
],
"organization": "Nozomi Networks",
"summary": "reporting the vulnerability"
}
],
"category": "Siemens Security Advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited.",
"tlp": {
"label": "WHITE"
}
},
"notes": [
{
"category": "summary",
"text": "A vulnerability in several SCALANCE X devices could allow an unauthenticated attacker with network access to an affected device to perform a denial-of-service.\n\nSiemens has released an update for SCALANCE X-200IRT and recommends to update to the latest version. Siemens recommends specific countermeasures for products where updates are not, or not yet available.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
"title": "Terms of Use"
}
],
"publisher": {
"category": "vendor",
"contact_details": "productcert@siemens.com",
"name": "Siemens ProductCERT",
"namespace": "https://www.siemens.com"
},
"references": [
{
"category": "self",
"summary": "SSA-100232: Denial-of-Service vulnerability in SCALANCE X Switches - PDF Version",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-100232.pdf"
},
{
"category": "self",
"summary": "SSA-100232: Denial-of-Service vulnerability in SCALANCE X Switches - TXT Version",
"url": "https://cert-portal.siemens.com/productcert/txt/ssa-100232.txt"
},
{
"category": "self",
"summary": "SSA-100232: Denial-of-Service vulnerability in SCALANCE X Switches - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-100232.json"
}
],
"title": "SSA-100232: Denial-of-Service vulnerability in SCALANCE X Switches",
"tracking": {
"current_release_date": "2022-02-08T00:00:00Z",
"generator": {
"engine": {
"name": "Siemens ProductCERT CSAF Generator",
"version": "1"
}
},
"id": "SSA-100232",
"initial_release_date": "2019-08-13T00:00:00Z",
"revision_history": [
{
"date": "2019-08-13T00:00:00Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
},
{
"date": "2020-02-10T00:00:00Z",
"legacy_version": "1.1",
"number": "2",
"summary": "SIPLUS devices now explicitly mentioned in the list of affected products"
},
{
"date": "2021-02-09T00:00:00Z",
"legacy_version": "1.2",
"number": "3",
"summary": "Added update information for SCALANCE X-200IRT switch family"
},
{
"date": "2021-09-14T00:00:00Z",
"legacy_version": "1.3",
"number": "4",
"summary": "Added solution for SCALANCE X-200 switch family"
},
{
"date": "2022-02-08T00:00:00Z",
"legacy_version": "1.4",
"number": "5",
"summary": "Specifically added that SCALANCE X204RNA devices do not have any fix planned"
}
],
"status": "final",
"version": "5"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X204RNA (HSR) (6GK5204-0BA00-2MB2)",
"product_id": "1",
"product_identification_helper": {
"model_numbers": [
"6GK5204-0BA00-2MB2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X204RNA (HSR)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X204RNA (PRP) (6GK5204-0BA00-2KB2)",
"product_id": "2",
"product_identification_helper": {
"model_numbers": [
"6GK5204-0BA00-2KB2"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X204RNA (PRP)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X204RNA EEC (HSR) (6GK5204-0BS00-2NA3)",
"product_id": "3",
"product_identification_helper": {
"model_numbers": [
"6GK5204-0BS00-2NA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X204RNA EEC (HSR)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X204RNA EEC (PRP) (6GK5204-0BS00-3LA3)",
"product_id": "4",
"product_identification_helper": {
"model_numbers": [
"6GK5204-0BS00-3LA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X204RNA EEC (PRP)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SCALANCE X204RNA EEC (PRP/HSR) (6GK5204-0BS00-3PA3)",
"product_id": "5",
"product_identification_helper": {
"model_numbers": [
"6GK5204-0BS00-3PA3"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE X204RNA EEC (PRP/HSR)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V5.2.5",
"product": {
"name": "SCALANCE X-200 switch family (incl. SIPLUS NET variants)",
"product_id": "6"
}
}
],
"category": "product_name",
"name": "SCALANCE X-200 switch family (incl. SIPLUS NET variants)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V5.5.0",
"product": {
"name": "SCALANCE X-200IRT switch family (incl. SIPLUS NET variants)",
"product_id": "7"
}
}
],
"category": "product_name",
"name": "SCALANCE X-200IRT switch family (incl. SIPLUS NET variants)"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2019-10942",
"cwe": {
"id": "CWE-400",
"name": "Uncontrolled Resource Consumption"
},
"notes": [
{
"category": "summary",
"text": "The device contains a vulnerability that could allow an attacker to trigger a denial-of-service condition by sending large message packages repeatedly to the telnet service.\n\nThe security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the device.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6",
"7"
]
},
"references": [
{
"summary": "CVE-2019-10942 - SCALANCE X-200 switch family (incl. SIPLUS NET variants)",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109801131/"
},
{
"summary": "CVE-2019-10942 - SCALANCE X-200IRT switch family (incl. SIPLUS NET variants)",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109792534/"
},
{
"summary": "CVE-2019-10942 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2019-10942.json"
}
],
"remediations": [
{
"category": "no_fix_planned",
"details": "Currently no remediation is planned",
"product_ids": [
"1",
"2",
"3",
"4",
"5"
]
},
{
"category": "vendor_fix",
"details": "Update to V5.2.5 or later version",
"product_ids": [
"6"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109801131/"
},
{
"category": "vendor_fix",
"details": "Update to V5.5.0 or later version",
"product_ids": [
"7"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109792534/"
},
{
"category": "mitigation",
"details": "Restrict network access to port 23/tcp of the device",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7"
]
},
{
"category": "mitigation",
"details": "Disable telnet service on affected devices and use SSH instead",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 8.6,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H/E:P/RL:T/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6",
"7"
]
}
],
"title": "CVE-2019-10942"
}
]
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.