SSA-042050
Vulnerability from csaf_siemens - Published: 2023-06-13 00:00 - Updated: 2024-12-10 00:00| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Totally Integrated Automation Portal (TIA Portal) V14
Siemens / Totally Integrated Automation Portal (TIA Portal) V14
|
vers:all/* |
Mitigation
No Fix Planned
|
|
|
Totally Integrated Automation Portal (TIA Portal) V15
Siemens / Totally Integrated Automation Portal (TIA Portal) V15
|
vers:all/* |
Mitigation
No Fix Planned
|
|
|
Totally Integrated Automation Portal (TIA Portal) V15.1
Siemens / Totally Integrated Automation Portal (TIA Portal) V15.1
|
vers:all/* |
Mitigation
No Fix Planned
|
|
|
Totally Integrated Automation Portal (TIA Portal) V16
Siemens / Totally Integrated Automation Portal (TIA Portal) V16
|
vers:all/* |
Mitigation
No Fix Planned
|
|
|
Totally Integrated Automation Portal (TIA Portal) V17
Siemens / Totally Integrated Automation Portal (TIA Portal) V17
|
vers:all/* |
Mitigation
No Fix Planned
|
|
|
Totally Integrated Automation Portal (TIA Portal) V18
Siemens / Totally Integrated Automation Portal (TIA Portal) V18
|
vers:all/* |
Mitigation
No Fix Planned
|
|
|
Totally Integrated Automation Portal (TIA Portal) V19
Siemens / Totally Integrated Automation Portal (TIA Portal) V19
|
vers:all/* |
Mitigation
No Fix Planned
|
|
|
Totally Integrated Automation Portal (TIA Portal) V20
Siemens / Totally Integrated Automation Portal (TIA Portal) V20
|
vers:all/* |
Mitigation
No Fix Planned
|
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)",
"tlp": {
"label": "WHITE"
}
},
"lang": "en",
"notes": [
{
"category": "summary",
"text": "The know-how protection feature in Totally Integrated Automation Portal (TIA Portal) does not properly update the encryption of existing program blocks when a project file is updated. This could allow attackers with access to the project file to recover previous - yet unprotected - versions of the project without the knowledge of the know-how protection password.\n\nSiemens recommends specific countermeasures for products where fixes are not, or not yet available.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.",
"title": "Terms of Use"
}
],
"publisher": {
"category": "vendor",
"contact_details": "productcert@siemens.com",
"name": "Siemens ProductCERT",
"namespace": "https://www.siemens.com"
},
"references": [
{
"category": "self",
"summary": "SSA-042050: Know-How Protection Mechanism Failure in TIA Portal - HTML Version",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-042050.html"
},
{
"category": "self",
"summary": "SSA-042050: Know-How Protection Mechanism Failure in TIA Portal - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-042050.json"
}
],
"title": "SSA-042050: Know-How Protection Mechanism Failure in TIA Portal",
"tracking": {
"current_release_date": "2024-12-10T00:00:00Z",
"generator": {
"engine": {
"name": "Siemens ProductCERT CSAF Generator",
"version": "1"
}
},
"id": "SSA-042050",
"initial_release_date": "2023-06-13T00:00:00Z",
"revision_history": [
{
"date": "2023-06-13T00:00:00Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
},
{
"date": "2023-12-12T00:00:00Z",
"legacy_version": "1.1",
"number": "2",
"summary": "Added Totally Integrated Automation Portal (TIA Portal) V19 as affected product"
},
{
"date": "2024-12-10T00:00:00Z",
"legacy_version": "1.2",
"number": "3",
"summary": "No fix planned for Totally Integrated Automation Portal (TIA Portal) V19; Added Totally Integrated Automation Portal (TIA Portal) V20 as affected product"
}
],
"status": "final",
"version": "3"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Totally Integrated Automation Portal (TIA Portal) V14",
"product_id": "1"
}
}
],
"category": "product_name",
"name": "Totally Integrated Automation Portal (TIA Portal) V14"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Totally Integrated Automation Portal (TIA Portal) V15",
"product_id": "2"
}
}
],
"category": "product_name",
"name": "Totally Integrated Automation Portal (TIA Portal) V15"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Totally Integrated Automation Portal (TIA Portal) V15.1",
"product_id": "3"
}
}
],
"category": "product_name",
"name": "Totally Integrated Automation Portal (TIA Portal) V15.1"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Totally Integrated Automation Portal (TIA Portal) V16",
"product_id": "4"
}
}
],
"category": "product_name",
"name": "Totally Integrated Automation Portal (TIA Portal) V16"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Totally Integrated Automation Portal (TIA Portal) V17",
"product_id": "5"
}
}
],
"category": "product_name",
"name": "Totally Integrated Automation Portal (TIA Portal) V17"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Totally Integrated Automation Portal (TIA Portal) V18",
"product_id": "6"
}
}
],
"category": "product_name",
"name": "Totally Integrated Automation Portal (TIA Portal) V18"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Totally Integrated Automation Portal (TIA Portal) V19",
"product_id": "7"
}
}
],
"category": "product_name",
"name": "Totally Integrated Automation Portal (TIA Portal) V19"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Totally Integrated Automation Portal (TIA Portal) V20",
"product_id": "8"
}
}
],
"category": "product_name",
"name": "Totally Integrated Automation Portal (TIA Portal) V20"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2023-30757",
"cwe": {
"id": "CWE-693",
"name": "Protection Mechanism Failure"
},
"notes": [
{
"category": "summary",
"text": "The know-how protection feature in affected products does not properly update the encryption of existing program blocks when a project file is updated.\r\n\r\nThis could allow attackers with access to the project file to recover previous - yet unprotected - versions of the project without the knowledge of the know-how protection password.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Archive the project: the optimization of project data during archiving removes older, possibly unprotected project content; see also the chapter \"Protecting Blocks\" in the system manual (\nhttps://docs.tia.siemens.cloud/r/en-us/v20/protecting-blocks)",
"product_ids": [
"8"
]
},
{
"category": "mitigation",
"details": "Archive the project: the optimization of project data during archiving removes older, possibly unprotected project content; see also the chapter \"Protecting Blocks\" in the system manual (\nhttps://support.industry.siemens.com/cs/mdm/109742284?c=87347935883)",
"product_ids": [
"1"
]
},
{
"category": "mitigation",
"details": "Archive the project: the optimization of project data during archiving removes older, possibly unprotected project content; see also the chapter \"Protecting Blocks\" in the system manual (\nhttps://support.industry.siemens.com/cs/mdm/109755202?c=105012867723)",
"product_ids": [
"3"
]
},
{
"category": "mitigation",
"details": "Archive the project: the optimization of project data during archiving removes older, possibly unprotected project content; see also the chapter \"Protecting Blocks\" in the system manual (\nhttps://support.industry.siemens.com/cs/mdm/109764516?c=105012867723)",
"product_ids": [
"2"
]
},
{
"category": "mitigation",
"details": "Archive the project: the optimization of project data during archiving removes older, possibly unprotected project content; see also the chapter \"Protecting Blocks\" in the system manual (\nhttps://support.industry.siemens.com/cs/mdm/109773506?c=126979557387)",
"product_ids": [
"4"
]
},
{
"category": "mitigation",
"details": "Archive the project: the optimization of project data during archiving removes older, possibly unprotected project content; see also the chapter \"Protecting Blocks\" in the system manual (\nhttps://support.industry.siemens.com/cs/mdm/109798671?c=132780438283)",
"product_ids": [
"5"
]
},
{
"category": "mitigation",
"details": "Archive the project: the optimization of project data during archiving removes older, possibly unprotected project content; see also the chapter \"Protecting Blocks\" in the system manual (\nhttps://support.industry.siemens.com/cs/mdm/109815056?c=132780438283)",
"product_ids": [
"6"
]
},
{
"category": "mitigation",
"details": "Archive the project: the optimization of project data during archiving removes older, possibly unprotected project content; see also the chapters \"Security information\" and \"Protecting Blocks\" in the system manual (\nhttps://support.industry.siemens.com/cs/ww/en/view/109826862/)",
"product_ids": [
"7"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.2,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:T/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8"
]
}
],
"title": "CVE-2023-30757"
}
]
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.