CVE-2018-16555 (GCVE-0-2018-16555)

Vulnerability from cvelistv5 – Published: 2018-12-13 16:00 – Updated: 2024-08-05 10:24
VLAI
Summary
A vulnerability has been identified in SCALANCE S602 (All versions < V4.0.1.1), SCALANCE S612 (All versions < V4.0.1.1), SCALANCE S623 (All versions < V4.0.1.1), SCALANCE S627-2M (All versions < V4.0.1.1). The integrated web server could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. User interaction is required for a successful exploitation. The user must be logged into the web interface in order for the exploitation to succeed. At the stage of publishing this security advisory no public exploitation is known.
CWE
  • CWE-80 - Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)
Assigner
siemens CNA under the icscert root
CNA scorecard C 65/100 over 100 records in the last 180 days details
References
Impacted products
Vendor Product Version CPE status
Siemens AG SCALANCE S602, SCALANCE S612, SCALANCE S623, SCALANCE S627-2M Affected: SCALANCE S602 : All versions < V4.0.1.1
Affected: SCALANCE S612 : All versions < V4.0.1.1
Affected: SCALANCE S623 : All versions < V4.0.1.1
Affected: SCALANCE S627-2M : All versions < V4.0.1.1
guessed Create a notification for this product.
Date Public
2018-12-13 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T10:24:32.846Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-242982.pdf"
          },
          {
            "name": "105937",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/105937"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SCALANCE S602, SCALANCE S612, SCALANCE S623, SCALANCE S627-2M",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "SCALANCE S602 : All versions \u003c V4.0.1.1"
            },
            {
              "status": "affected",
              "version": "SCALANCE S612 : All versions \u003c V4.0.1.1"
            },
            {
              "status": "affected",
              "version": "SCALANCE S623 : All versions \u003c V4.0.1.1"
            },
            {
              "status": "affected",
              "version": "SCALANCE S627-2M : All versions \u003c V4.0.1.1"
            }
          ]
        }
      ],
      "datePublic": "2018-12-13T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SCALANCE S602 (All versions \u003c V4.0.1.1), SCALANCE S612 (All versions \u003c V4.0.1.1), SCALANCE S623 (All versions \u003c V4.0.1.1), SCALANCE S627-2M (All versions \u003c V4.0.1.1). The integrated web server could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. User interaction is required for a successful exploitation. The user must be logged into the web interface in order for the exploitation to succeed. At the stage of publishing this security advisory no public exploitation is known."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-80",
              "description": "CWE-80: Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-12-14T10:57:02.000Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-242982.pdf"
        },
        {
          "name": "105937",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/105937"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2018-16555",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SCALANCE S602, SCALANCE S612, SCALANCE S623, SCALANCE S627-2M",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "SCALANCE S602 : All versions \u003c V4.0.1.1"
                          },
                          {
                            "version_value": "SCALANCE S612 : All versions \u003c V4.0.1.1"
                          },
                          {
                            "version_value": "SCALANCE S623 : All versions \u003c V4.0.1.1"
                          },
                          {
                            "version_value": "SCALANCE S627-2M : All versions \u003c V4.0.1.1"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens AG"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in SCALANCE S602 (All versions \u003c V4.0.1.1), SCALANCE S612 (All versions \u003c V4.0.1.1), SCALANCE S623 (All versions \u003c V4.0.1.1), SCALANCE S627-2M (All versions \u003c V4.0.1.1). The integrated web server could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. User interaction is required for a successful exploitation. The user must be logged into the web interface in order for the exploitation to succeed. At the stage of publishing this security advisory no public exploitation is known."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-80: Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-242982.pdf",
              "refsource": "CONFIRM",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-242982.pdf"
            },
            {
              "name": "105937",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/105937"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2018-16555",
    "datePublished": "2018-12-13T16:00:00.000Z",
    "dateReserved": "2018-09-06T00:00:00.000Z",
    "dateUpdated": "2024-08-05T10:24:32.846Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2018-16555",
      "date": "2026-11-01",
      "epss": "0.00689",
      "percentile": "0.52752"
    },
    "nvd": {
      "cve": {
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:siemens:scalance_s602_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "73E004D9-009E-4051-9B38-76E35EB28B72",
                    "versionEndExcluding": "v4.0.1.1",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:siemens:scalance_s602:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "F4D89D82-C2CE-44DC-A05B-B956F20BF4E3",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:siemens:scalance_s612_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "B99D6B28-85DB-4114-B65C-4E5FF867E5A5",
                    "versionEndExcluding": "4.0.1.1",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:siemens:scalance_s612:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "CA7B48D2-0D17-420D-AAE1-35E5C0BE2924",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:siemens:scalance_s623_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "4707AB43-A39A-4101-92E4-369676CFC952",
                    "versionEndExcluding": "4.0.1.1",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:siemens:scalance_s623:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "F80D9A79-7984-462B-B4B9-6A4429422038",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:siemens:scalance_s627-2m_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "55C8AFCD-A9F0-45DE-AC5D-550F2DA2CF3F",
                    "versionEndExcluding": "4.0.1.1",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:siemens:scalance_s627-2m:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "B51B40F8-71D2-4D2D-8EC2-CE154A6D7533",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "A vulnerability has been identified in SCALANCE S602 (All versions \u003c V4.0.1.1), SCALANCE S612 (All versions \u003c V4.0.1.1), SCALANCE S623 (All versions \u003c V4.0.1.1), SCALANCE S627-2M (All versions \u003c V4.0.1.1). The integrated web server could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. User interaction is required for a successful exploitation. The user must be logged into the web interface in order for the exploitation to succeed. At the stage of publishing this security advisory no public exploitation is known."
          },
          {
            "lang": "es",
            "value": "Se ha identificado una vulnerabilidad en SCALANCE S602 (todas las versiones anteriores a la V4.0.1.1), SCALANCE S612 (todas las versiones anteriores a la V4.0.1.1), SCALANCE S623 (todas las versiones anteriores a la V4.0.1.1), SCALANCE S627-2M (todas las versiones anteriores a la V4.0.1.1). El servidor web integrado podr\u00eda permitir ataques Cross-Site Scripting (XSS) si los usuarios incautos son enga\u00f1ados para que accedan a un enlace malicioso. Se necesita interacci\u00f3n del usuario para explotar esta vulnerabilidad con \u00e9xito. El usuario debe haber iniciado sesi\u00f3n en la interfaz web para que la explotaci\u00f3n tenga \u00e9xito. En el momento de publicaci\u00f3n de este aviso de seguridad, no se conoce ninguna explotaci\u00f3n p\u00fablica."
          }
        ],
        "id": "CVE-2018-16555",
        "lastModified": "2024-11-21T03:52:58.247",
        "metrics": {
          "cvssMetricV2": [
            {
              "acInsufInfo": false,
              "baseSeverity": "LOW",
              "cvssData": {
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "availabilityImpact": "NONE",
                "baseScore": 3.5,
                "confidentialityImpact": "NONE",
                "integrityImpact": "PARTIAL",
                "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
                "version": "2.0"
              },
              "exploitabilityScore": 6.8,
              "impactScore": 2.9,
              "obtainAllPrivilege": false,
              "obtainOtherPrivilege": false,
              "obtainUserPrivilege": false,
              "source": "nvd@nist.gov",
              "type": "Primary",
              "userInteractionRequired": true
            }
          ],
          "cvssMetricV30": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 5.4,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "LOW",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
                "version": "3.0"
              },
              "exploitabilityScore": 2.3,
              "impactScore": 2.7,
              "source": "nvd@nist.gov",
              "type": "Primary"
            }
          ]
        },
        "published": "2018-12-13T16:29:00.460",
        "references": [
          {
            "source": "productcert@siemens.com",
            "tags": [
              "Third Party Advisory",
              "VDB Entry"
            ],
            "url": "http://www.securityfocus.com/bid/105937"
          },
          {
            "source": "productcert@siemens.com",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-242982.pdf"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Third Party Advisory",
              "VDB Entry"
            ],
            "url": "http://www.securityfocus.com/bid/105937"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-242982.pdf"
          }
        ],
        "sourceIdentifier": "productcert@siemens.com",
        "vulnStatus": "Modified",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-80"
              }
            ],
            "source": "productcert@siemens.com",
            "type": "Secondary"
          },
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-79"
              }
            ],
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      }
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline

Sightings and recorded dates, grouped by day · UTC

JSON
Events included in the timeline

Loading timeline…


    Loading…

    Loading…

    Loading…

    Related by attack behaviour

    Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.