CVE-2026-84941 (GCVE-0-2026-84941)

Vulnerability from cvelistv5 – Published: 2026-09-10 23:35 – Updated: 2026-09-11 13:16
VLAI
Title
Omada Controller XML External Entity (XXE) Injection in SAML IdP Metadata Parsing Leading to Arbitrary Local File Read
Summary
An information disclosure vulnerability in the SAML Single Sign-On (SSO) functionality of Omada Controller allows an authenticated user with SAML configuration privileges to access sensitive information due to insufficient validation of user-supplied SAML metadata. Successful exploitation could result in unauthorized disclosure of sensitive information.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-11 13:10 UTC
CWE
  • CWE-611 - Improper restriction of XML external entity reference
Assigner
TPLink CNA under the mitre root
CNA scorecard B 87/100 over 110 records in the last 180 days details
Impacted products
Vendor Product Version CPE status
TP-Link Systems Inc. Omada Software Controller (Windows) Affected: 0 , < 6.2.14.11 (custom)
guessed Create a notification for this product.
TP-Link Systems Inc. Omada Software Controller (Linux) Affected: 0 , < 6.2.14.11 (custom)
guessed Create a notification for this product.
TP-Link Systems Inc. OC2000 v1 Affected: 0 , < 1.41.11 Build 20260711 (custom)
guessed Create a notification for this product.
TP-Link Systems Inc. OC2000 v2 Affected: 0 , < 2.26.11 Build 20260711 (custom)
guessed Create a notification for this product.
TP-Link Systems Inc. OC200 v3 Affected: 0 , < 3.3.11 Build 20260711 (custom)
guessed Create a notification for this product.
TP-Link Systems Inc. OC220 v1 Affected: 0 , < 1.6.11 Build 20260711 (custom)
guessed Create a notification for this product.
TP-Link Systems Inc. OC220 v2 Affected: 0 , < 2.5.11 Build 20260711 (custom)
guessed Create a notification for this product.
TP-Link Systems Inc. OC300 v1 Affected: 0 , < 1.35.11 Build 20260711 (custom)
guessed Create a notification for this product.
TP-Link Systems Inc. OC400 v1 Affected: 0 , < 1.13.11 Build 20260711 (custom)
guessed Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-84941",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-09-11T13:10:27.244979Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-09-11T13:16:12.359Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "Omada Controller"
          ],
          "product": "Omada Software Controller (Windows)",
          "vendor": "TP-Link Systems Inc.",
          "versions": [
            {
              "lessThan": "6.2.14.11",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "Omada Controller"
          ],
          "product": "Omada Software Controller (Linux)",
          "vendor": "TP-Link Systems Inc.",
          "versions": [
            {
              "lessThan": "6.2.14.11",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "Omada Controller"
          ],
          "product": "OC2000 v1",
          "vendor": "TP-Link Systems Inc.",
          "versions": [
            {
              "lessThan": "1.41.11 Build 20260711",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "Omada Controller"
          ],
          "product": "OC2000 v2",
          "vendor": "TP-Link Systems Inc.",
          "versions": [
            {
              "lessThan": "2.26.11 Build 20260711",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "Omada Controller"
          ],
          "product": "OC200 v3",
          "vendor": "TP-Link Systems Inc.",
          "versions": [
            {
              "lessThan": "3.3.11 Build 20260711",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "Omada Controller"
          ],
          "product": "OC220 v1",
          "vendor": "TP-Link Systems Inc.",
          "versions": [
            {
              "lessThan": "1.6.11 Build 20260711",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "Omada Controller"
          ],
          "product": "OC220 v2",
          "vendor": "TP-Link Systems Inc.",
          "versions": [
            {
              "lessThan": "2.5.11 Build 20260711",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "Omada Controller"
          ],
          "product": "OC300 v1",
          "vendor": "TP-Link Systems Inc.",
          "versions": [
            {
              "lessThan": "1.35.11 Build 20260711",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "Omada Controller"
          ],
          "product": "OC400 v1",
          "vendor": "TP-Link Systems Inc.",
          "versions": [
            {
              "lessThan": "1.13.11 Build 20260711",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "erikdejong"
        },
        {
          "lang": "en",
          "type": "finder",
          "value": "mattgsys"
        },
        {
          "lang": "en",
          "type": "finder",
          "value": "eslam moneer (tohtmosiii)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cdiv\u003eAn information disclosure vulnerability in the SAML Single Sign-On (SSO) functionality of Omada Controller allows an authenticated user with SAML configuration privileges to access sensitive information due to insufficient validation of user-supplied SAML metadata. Successful exploitation could result in unauthorized disclosure of sensitive information.\u003c/div\u003e"
            }
          ],
          "value": "An information disclosure vulnerability in the SAML Single Sign-On (SSO) functionality of Omada Controller allows an authenticated user with SAML configuration privileges to access sensitive information due to insufficient validation of user-supplied SAML metadata. Successful exploitation could result in unauthorized disclosure of sensitive information."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-221",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-221 Data Serialization External Entities Blowup"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 6.9,
            "baseSeverity": "MEDIUM",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "HIGH",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-611",
              "description": "CWE-611 Improper restriction of XML external entity reference",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-09-10T23:35:53.023Z",
        "orgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
        "shortName": "TPLink"
      },
      "references": [
        {
          "tags": [
            "patch"
          ],
          "url": "https://support.omadanetworks.com/en/download/software/omada-controller"
        },
        {
          "tags": [
            "patch"
          ],
          "url": "https://support.omadanetworks.com/us/download/software/omada-controller"
        },
        {
          "tags": [
            "patch"
          ],
          "url": "https://www.omadanetworks.com/en/support/download/"
        },
        {
          "tags": [
            "patch"
          ],
          "url": "https://www.omadanetworks.com/us/support/download/"
        },
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://support.omadanetworks.com/en/document/133722/"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Omada Controller XML External Entity (XXE) Injection in SAML IdP Metadata Parsing Leading to Arbitrary Local File Read",
      "x_generator": {
        "engine": "Vulnogram 1.0.5"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
    "assignerShortName": "TPLink",
    "cveId": "CVE-2026-84941",
    "datePublished": "2026-09-10T23:35:53.023Z",
    "dateReserved": "2026-09-02T16:45:11.015Z",
    "dateUpdated": "2026-09-11T13:16:12.359Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2026-84941",
      "date": "2026-11-13",
      "epss": "0.00473",
      "percentile": "0.41447"
    },
    "nvd": {
      "cve": {
        "affected": [
          {
            "affectedData": [
              {
                "defaultStatus": "unaffected",
                "platforms": [
                  "Omada Controller"
                ],
                "product": "Omada Software Controller (Windows)",
                "vendor": "TP-Link Systems Inc.",
                "versions": [
                  {
                    "lessThan": "6.2.14.11",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "platforms": [
                  "Omada Controller"
                ],
                "product": "Omada Software Controller (Linux)",
                "vendor": "TP-Link Systems Inc.",
                "versions": [
                  {
                    "lessThan": "6.2.14.11",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "platforms": [
                  "Omada Controller"
                ],
                "product": "OC2000 v1",
                "vendor": "TP-Link Systems Inc.",
                "versions": [
                  {
                    "lessThan": "1.41.11 Build 20260711",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "platforms": [
                  "Omada Controller"
                ],
                "product": "OC2000 v2",
                "vendor": "TP-Link Systems Inc.",
                "versions": [
                  {
                    "lessThan": "2.26.11 Build 20260711",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "platforms": [
                  "Omada Controller"
                ],
                "product": "OC200 v3",
                "vendor": "TP-Link Systems Inc.",
                "versions": [
                  {
                    "lessThan": "3.3.11 Build 20260711",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "platforms": [
                  "Omada Controller"
                ],
                "product": "OC220 v1",
                "vendor": "TP-Link Systems Inc.",
                "versions": [
                  {
                    "lessThan": "1.6.11 Build 20260711",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "platforms": [
                  "Omada Controller"
                ],
                "product": "OC220 v2",
                "vendor": "TP-Link Systems Inc.",
                "versions": [
                  {
                    "lessThan": "2.5.11 Build 20260711",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "platforms": [
                  "Omada Controller"
                ],
                "product": "OC300 v1",
                "vendor": "TP-Link Systems Inc.",
                "versions": [
                  {
                    "lessThan": "1.35.11 Build 20260711",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "platforms": [
                  "Omada Controller"
                ],
                "product": "OC400 v1",
                "vendor": "TP-Link Systems Inc.",
                "versions": [
                  {
                    "lessThan": "1.13.11 Build 20260711",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "source": "f23511db-6c3e-4e32-a477-6aa17d310630"
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "An information disclosure vulnerability in the SAML Single Sign-On (SSO) functionality of Omada Controller allows an authenticated user with SAML configuration privileges to access sensitive information due to insufficient validation of user-supplied SAML metadata. Successful exploitation could result in unauthorized disclosure of sensitive information."
          }
        ],
        "id": "CVE-2026-84941",
        "lastModified": "2026-09-11T15:21:12.850",
        "metrics": {
          "cvssMetricV40": [
            {
              "cvssData": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "availabilityRequirement": "NOT_DEFINED",
                "baseScore": 6.9,
                "baseSeverity": "MEDIUM",
                "confidentialityRequirement": "NOT_DEFINED",
                "exploitMaturity": "NOT_DEFINED",
                "integrityRequirement": "NOT_DEFINED",
                "modifiedAttackComplexity": "NOT_DEFINED",
                "modifiedAttackRequirements": "NOT_DEFINED",
                "modifiedAttackVector": "NOT_DEFINED",
                "modifiedPrivilegesRequired": "NOT_DEFINED",
                "modifiedSubAvailabilityImpact": "NOT_DEFINED",
                "modifiedSubConfidentialityImpact": "NOT_DEFINED",
                "modifiedSubIntegrityImpact": "NOT_DEFINED",
                "modifiedUserInteraction": "NOT_DEFINED",
                "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
                "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
                "modifiedVulnIntegrityImpact": "NOT_DEFINED",
                "privilegesRequired": "HIGH",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "source": "f23511db-6c3e-4e32-a477-6aa17d310630",
              "type": "Secondary"
            }
          ],
          "ssvcV203": [
            {
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "ssvcData": {
                "id": "CVE-2026-84941",
                "options": [
                  {
                    "exploitation": "none"
                  },
                  {
                    "automatable": "no"
                  },
                  {
                    "technicalImpact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-09-11T13:10:27.244979Z",
                "version": "2.0.3"
              }
            }
          ]
        },
        "published": "2026-09-11T00:19:57.633",
        "references": [
          {
            "source": "f23511db-6c3e-4e32-a477-6aa17d310630",
            "url": "https://support.omadanetworks.com/en/document/133722/"
          },
          {
            "source": "f23511db-6c3e-4e32-a477-6aa17d310630",
            "url": "https://support.omadanetworks.com/en/download/software/omada-controller"
          },
          {
            "source": "f23511db-6c3e-4e32-a477-6aa17d310630",
            "url": "https://support.omadanetworks.com/us/download/software/omada-controller"
          },
          {
            "source": "f23511db-6c3e-4e32-a477-6aa17d310630",
            "url": "https://www.omadanetworks.com/en/support/download/"
          },
          {
            "source": "f23511db-6c3e-4e32-a477-6aa17d310630",
            "url": "https://www.omadanetworks.com/us/support/download/"
          }
        ],
        "sourceIdentifier": "f23511db-6c3e-4e32-a477-6aa17d310630",
        "vulnStatus": "Deferred",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-611"
              }
            ],
            "source": "f23511db-6c3e-4e32-a477-6aa17d310630",
            "type": "Secondary"
          }
        ]
      }
    },
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-84941",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-11T13:10:27.244979Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-11T13:16:06.612Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Omada Controller"
              ],
              "product": "Omada Software Controller (Windows)",
              "vendor": "TP-Link Systems Inc.",
              "versions": [
                {
                  "lessThan": "6.2.14.11",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Omada Controller"
              ],
              "product": "Omada Software Controller (Linux)",
              "vendor": "TP-Link Systems Inc.",
              "versions": [
                {
                  "lessThan": "6.2.14.11",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Omada Controller"
              ],
              "product": "OC2000 v1",
              "vendor": "TP-Link Systems Inc.",
              "versions": [
                {
                  "lessThan": "1.41.11 Build 20260711",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Omada Controller"
              ],
              "product": "OC2000 v2",
              "vendor": "TP-Link Systems Inc.",
              "versions": [
                {
                  "lessThan": "2.26.11 Build 20260711",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Omada Controller"
              ],
              "product": "OC200 v3",
              "vendor": "TP-Link Systems Inc.",
              "versions": [
                {
                  "lessThan": "3.3.11 Build 20260711",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Omada Controller"
              ],
              "product": "OC220 v1",
              "vendor": "TP-Link Systems Inc.",
              "versions": [
                {
                  "lessThan": "1.6.11 Build 20260711",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Omada Controller"
              ],
              "product": "OC220 v2",
              "vendor": "TP-Link Systems Inc.",
              "versions": [
                {
                  "lessThan": "2.5.11 Build 20260711",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Omada Controller"
              ],
              "product": "OC300 v1",
              "vendor": "TP-Link Systems Inc.",
              "versions": [
                {
                  "lessThan": "1.35.11 Build 20260711",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Omada Controller"
              ],
              "product": "OC400 v1",
              "vendor": "TP-Link Systems Inc.",
              "versions": [
                {
                  "lessThan": "1.13.11 Build 20260711",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "erikdejong"
            },
            {
              "lang": "en",
              "type": "finder",
              "value": "mattgsys"
            },
            {
              "lang": "en",
              "type": "finder",
              "value": "eslam moneer (tohtmosiii)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cdiv\u003eAn information disclosure vulnerability in the SAML Single Sign-On (SSO) functionality of Omada Controller allows an authenticated user with SAML configuration privileges to access sensitive information due to insufficient validation of user-supplied SAML metadata. Successful exploitation could result in unauthorized disclosure of sensitive information.\u003c/div\u003e"
                }
              ],
              "value": "An information disclosure vulnerability in the SAML Single Sign-On (SSO) functionality of Omada Controller allows an authenticated user with SAML configuration privileges to access sensitive information due to insufficient validation of user-supplied SAML metadata. Successful exploitation could result in unauthorized disclosure of sensitive information."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-221",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-221 Data Serialization External Entities Blowup"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 6.9,
                "baseSeverity": "MEDIUM",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "HIGH",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-611",
                  "description": "CWE-611 Improper restriction of XML external entity reference",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-10T23:35:53.023Z",
            "orgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
            "shortName": "TPLink"
          },
          "references": [
            {
              "tags": [
                "patch"
              ],
              "url": "https://support.omadanetworks.com/en/download/software/omada-controller"
            },
            {
              "tags": [
                "patch"
              ],
              "url": "https://support.omadanetworks.com/us/download/software/omada-controller"
            },
            {
              "tags": [
                "patch"
              ],
              "url": "https://www.omadanetworks.com/en/support/download/"
            },
            {
              "tags": [
                "patch"
              ],
              "url": "https://www.omadanetworks.com/us/support/download/"
            },
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://support.omadanetworks.com/en/document/133722/"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Omada Controller XML External Entity (XXE) Injection in SAML IdP Metadata Parsing Leading to Arbitrary Local File Read",
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
        "assignerShortName": "TPLink",
        "cveId": "CVE-2026-84941",
        "datePublished": "2026-09-10T23:35:53.023Z",
        "dateReserved": "2026-09-02T16:45:11.015Z",
        "dateUpdated": "2026-09-11T13:16:12.359Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline

Sightings and recorded dates, grouped by day · UTC

JSON
How durations are calculated

Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.

Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.

Events included in the timeline

Loading timeline…


    Loading…

    Loading…

    Loading…

    Related by attack behaviour

    Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.