CVE-2026-73460 (GCVE-0-2026-73460)
Vulnerability from cvelistv5 – Published: 2026-09-15 23:20 – Updated: 2026-09-16 19:35- CWE-863 - Incorrect Authorization
| URL | Tags |
|---|---|
| https://www.arista.com/en/support/advisories-noti… | vendor-advisory |
| Vendor | Product | Version | CPE status | |
|---|---|---|---|---|
| Arista Networks | EOS |
Affected:
4.36.0 , ≤ 4.36.1F
(custom)
|
guessed |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-73460",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-16T19:35:29.181267Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-16T19:35:40.181Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "EOS",
"vendor": "Arista Networks",
"versions": [
{
"lessThanOrEqual": "4.36.1F",
"status": "affected",
"version": "4.36.0",
"versionType": "custom"
}
]
}
],
"configurations": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eIn order to be vulnerable to CVE-2026-73460, the following condition must be met: IS-IS graceful-restart should be enabled.\u003c/p\u003e\u003cpre\u003eswitch(config-router-isis)#show active\nrouter isis 1\n\u0026nbsp;\u0026nbsp;\u0026nbsp;net 49.0001.1111.1111.1001.00\n\u0026nbsp;\u0026nbsp;\u0026nbsp;graceful-restart\u003cbr\u003e\u003cbr\u003e\u003cpre\u003eswitch#show isis graceful-restart\nIS-IS Instance: 1 VRF: default\n\u0026nbsp;\u0026nbsp;System ID: 1111.1111.1001\n\u0026nbsp;\u0026nbsp;Graceful Restart: Enabled, Graceful Restart Helper: Enabled\n\u0026nbsp;\u0026nbsp;State: Graceful Restart disabled during startup\n\u0026nbsp;\u0026nbsp;T1 : 3s\n\u0026nbsp;\u0026nbsp;T2 (level-1) : 30s/not running\n\u0026nbsp;\u0026nbsp;T2 (level-2) : 30s/not running\n\u0026nbsp;\u0026nbsp;T3 : not running\n\u0026nbsp;\u0026nbsp;System ID\u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp; Type\u0026nbsp; \u0026nbsp; Interface\u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp; Restart Capable \u0026nbsp; Status\u0026nbsp;\u0026nbsp;\u0026nbsp;\u0026nbsp;\n\u0026nbsp;\u0026nbsp;1111.1111.1002 \u0026nbsp; \u0026nbsp; L1\u0026nbsp; \u0026nbsp; \u0026nbsp; Ethernet1\u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp; Yes \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp; Running\u0026nbsp; \u003c/pre\u003e\u003c/pre\u003e\u003cp\u003eIf IS-IS graceful-restart is not enabled, there is no exposure to this issue.\u003c/p\u003e"
}
],
"value": "In order to be vulnerable to CVE-2026-73460, the following condition must be met: IS-IS graceful-restart should be enabled.\n\n\n\nswitch(config-router-isis)#show active\nrouter isis 1\n\u00a0\u00a0\u00a0net 49.0001.1111.1111.1001.00\n\u00a0\u00a0\u00a0graceful-restart\n\n\n\nswitch#show isis graceful-restart\nIS-IS Instance: 1 VRF: default\n\u00a0\u00a0System ID: 1111.1111.1001\n\u00a0\u00a0Graceful Restart: Enabled, Graceful Restart Helper: Enabled\n\u00a0\u00a0State: Graceful Restart disabled during startup\n\u00a0\u00a0T1 : 3s\n\u00a0\u00a0T2 (level-1) : 30s/not running\n\u00a0\u00a0T2 (level-2) : 30s/not running\n\u00a0\u00a0T3 : not running\n\u00a0\u00a0System ID\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 Type\u00a0 \u00a0 Interface\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 Restart Capable \u00a0 Status\u00a0\u00a0\u00a0\u00a0\n\u00a0\u00a01111.1111.1002 \u00a0 \u00a0 L1\u00a0 \u00a0 \u00a0 Ethernet1\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 Yes \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 Running\u00a0 \n\n\n\n\n\nIf IS-IS graceful-restart is not enabled, there is no exposure to this issue."
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "This issue was discovered internally by Arista and the company is not aware of any malicious uses of these issues in customer networks."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eOn affected platforms running Arista EOS with IS-IS graceful restart enabled, an unauthenticated attacker who can inject a malformed IS-IS LSP PDU packet can cause the IS-IS graceful restart procedure to terminate prematurely. This may result in traffic loss following a restart event.\u003c/p\u003e"
}
],
"value": "On affected platforms running Arista EOS with IS-IS graceful restart enabled, an unauthenticated attacker who can inject a malformed IS-IS LSP PDU packet can cause the IS-IS graceful restart procedure to terminate prematurely. This may result in traffic loss following a restart event."
}
],
"impacts": [
{
"capecId": "CAPEC-272",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-272 Protocol Manipulation"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:C/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "HIGH",
"attackRequirements": "PRESENT",
"attackVector": "ADJACENT",
"baseScore": 7,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:H/AT:P/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-863",
"description": "CWE-863: Incorrect Authorization",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-15T23:20:43.813Z",
"orgId": "c8b34d1a-69ae-45c3-88fe-f3b3d44f39b7",
"shortName": "Arista"
},
"references": [
{
"name": "Security Advisory 0160",
"tags": [
"vendor-advisory"
],
"url": "https://www.arista.com/en/support/advisories-notices/security-advisory/24716-security-advisory-0160"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eThe recommended resolution is to upgrade to a fixed software version.\u003c/p\u003e"
}
],
"value": "The recommended resolution is to upgrade to a fixed software version."
}
],
"source": {
"advisory": "0160",
"defects": [
"BUG1840562"
],
"discovery": "UNKNOWN"
},
"title": "Security Advisory 0160",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eNo workaround is available for this issue.\u003c/p\u003e"
}
],
"value": "No workaround is available for this issue."
}
],
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "c8b34d1a-69ae-45c3-88fe-f3b3d44f39b7",
"assignerShortName": "Arista",
"cveId": "CVE-2026-73460",
"datePublished": "2026-09-15T23:20:43.813Z",
"dateReserved": "2026-08-12T16:45:03.511Z",
"dateUpdated": "2026-09-16T19:35:40.181Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2026-73460",
"date": "2026-11-15",
"epss": "0.00197",
"percentile": "0.09464"
},
"nvd": {
"cve": {
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "EOS",
"vendor": "Arista Networks",
"versions": [
{
"lessThanOrEqual": "4.36.1F",
"status": "affected",
"version": "4.36.0",
"versionType": "custom"
}
]
}
],
"source": "psirt@arista.com"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "On affected platforms running Arista EOS with IS-IS graceful restart enabled, an unauthenticated attacker who can inject a malformed IS-IS LSP PDU packet can cause the IS-IS graceful restart procedure to terminate prematurely. This may result in traffic loss following a restart event."
}
],
"id": "CVE-2026-73460",
"lastModified": "2026-09-16T20:17:28.110",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:C/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.6,
"impactScore": 4.0,
"source": "psirt@arista.com",
"type": "Secondary"
}
],
"cvssMetricV40": [
{
"cvssData": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "HIGH",
"attackRequirements": "PRESENT",
"attackVector": "ADJACENT",
"availabilityRequirement": "NOT_DEFINED",
"baseScore": 7.0,
"baseSeverity": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"exploitMaturity": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:H/AT:P/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"source": "psirt@arista.com",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2026-73460",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-16T19:35:29.181267Z",
"version": "2.0.3"
}
}
]
},
"published": "2026-09-16T00:17:05.397",
"references": [
{
"source": "psirt@arista.com",
"url": "https://www.arista.com/en/support/advisories-notices/security-advisory/24716-security-advisory-0160"
}
],
"sourceIdentifier": "psirt@arista.com",
"vulnStatus": "Awaiting Analysis",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-863"
}
],
"source": "psirt@arista.com",
"type": "Secondary"
}
]
}
},
"vulnrichment": {
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-73460",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-16T19:35:29.181267Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-16T19:35:35.763Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "EOS",
"vendor": "Arista Networks",
"versions": [
{
"lessThanOrEqual": "4.36.1F",
"status": "affected",
"version": "4.36.0",
"versionType": "custom"
}
]
}
],
"configurations": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eIn order to be vulnerable to CVE-2026-73460, the following condition must be met: IS-IS graceful-restart should be enabled.\u003c/p\u003e\u003cpre\u003eswitch(config-router-isis)#show active\nrouter isis 1\n\u0026nbsp;\u0026nbsp;\u0026nbsp;net 49.0001.1111.1111.1001.00\n\u0026nbsp;\u0026nbsp;\u0026nbsp;graceful-restart\u003cbr\u003e\u003cbr\u003e\u003cpre\u003eswitch#show isis graceful-restart\nIS-IS Instance: 1 VRF: default\n\u0026nbsp;\u0026nbsp;System ID: 1111.1111.1001\n\u0026nbsp;\u0026nbsp;Graceful Restart: Enabled, Graceful Restart Helper: Enabled\n\u0026nbsp;\u0026nbsp;State: Graceful Restart disabled during startup\n\u0026nbsp;\u0026nbsp;T1 : 3s\n\u0026nbsp;\u0026nbsp;T2 (level-1) : 30s/not running\n\u0026nbsp;\u0026nbsp;T2 (level-2) : 30s/not running\n\u0026nbsp;\u0026nbsp;T3 : not running\n\u0026nbsp;\u0026nbsp;System ID\u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp; Type\u0026nbsp; \u0026nbsp; Interface\u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp; Restart Capable \u0026nbsp; Status\u0026nbsp;\u0026nbsp;\u0026nbsp;\u0026nbsp;\n\u0026nbsp;\u0026nbsp;1111.1111.1002 \u0026nbsp; \u0026nbsp; L1\u0026nbsp; \u0026nbsp; \u0026nbsp; Ethernet1\u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp; Yes \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp; Running\u0026nbsp; \u003c/pre\u003e\u003c/pre\u003e\u003cp\u003eIf IS-IS graceful-restart is not enabled, there is no exposure to this issue.\u003c/p\u003e"
}
],
"value": "In order to be vulnerable to CVE-2026-73460, the following condition must be met: IS-IS graceful-restart should be enabled.\n\n\n\nswitch(config-router-isis)#show active\nrouter isis 1\n\u00a0\u00a0\u00a0net 49.0001.1111.1111.1001.00\n\u00a0\u00a0\u00a0graceful-restart\n\n\n\nswitch#show isis graceful-restart\nIS-IS Instance: 1 VRF: default\n\u00a0\u00a0System ID: 1111.1111.1001\n\u00a0\u00a0Graceful Restart: Enabled, Graceful Restart Helper: Enabled\n\u00a0\u00a0State: Graceful Restart disabled during startup\n\u00a0\u00a0T1 : 3s\n\u00a0\u00a0T2 (level-1) : 30s/not running\n\u00a0\u00a0T2 (level-2) : 30s/not running\n\u00a0\u00a0T3 : not running\n\u00a0\u00a0System ID\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 Type\u00a0 \u00a0 Interface\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 Restart Capable \u00a0 Status\u00a0\u00a0\u00a0\u00a0\n\u00a0\u00a01111.1111.1002 \u00a0 \u00a0 L1\u00a0 \u00a0 \u00a0 Ethernet1\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 Yes \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 Running\u00a0 \n\n\n\n\n\nIf IS-IS graceful-restart is not enabled, there is no exposure to this issue."
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "This issue was discovered internally by Arista and the company is not aware of any malicious uses of these issues in customer networks."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eOn affected platforms running Arista EOS with IS-IS graceful restart enabled, an unauthenticated attacker who can inject a malformed IS-IS LSP PDU packet can cause the IS-IS graceful restart procedure to terminate prematurely. This may result in traffic loss following a restart event.\u003c/p\u003e"
}
],
"value": "On affected platforms running Arista EOS with IS-IS graceful restart enabled, an unauthenticated attacker who can inject a malformed IS-IS LSP PDU packet can cause the IS-IS graceful restart procedure to terminate prematurely. This may result in traffic loss following a restart event."
}
],
"impacts": [
{
"capecId": "CAPEC-272",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-272 Protocol Manipulation"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:C/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "HIGH",
"attackRequirements": "PRESENT",
"attackVector": "ADJACENT",
"baseScore": 7,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:H/AT:P/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-863",
"description": "CWE-863: Incorrect Authorization",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-15T23:20:43.813Z",
"orgId": "c8b34d1a-69ae-45c3-88fe-f3b3d44f39b7",
"shortName": "Arista"
},
"references": [
{
"name": "Security Advisory 0160",
"tags": [
"vendor-advisory"
],
"url": "https://www.arista.com/en/support/advisories-notices/security-advisory/24716-security-advisory-0160"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eThe recommended resolution is to upgrade to a fixed software version.\u003c/p\u003e"
}
],
"value": "The recommended resolution is to upgrade to a fixed software version."
}
],
"source": {
"advisory": "0160",
"defects": [
"BUG1840562"
],
"discovery": "UNKNOWN"
},
"title": "Security Advisory 0160",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eNo workaround is available for this issue.\u003c/p\u003e"
}
],
"value": "No workaround is available for this issue."
}
],
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "c8b34d1a-69ae-45c3-88fe-f3b3d44f39b7",
"assignerShortName": "Arista",
"cveId": "CVE-2026-73460",
"datePublished": "2026-09-15T23:20:43.813Z",
"dateReserved": "2026-08-12T16:45:03.511Z",
"dateUpdated": "2026-09-15T23:20:43.813Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
}
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.