CVE-2026-56688 (GCVE-0-2026-56688)
Vulnerability from cvelistv5 – Published: 2026-07-10 11:57 – Updated: 2026-07-10 17:01
VLAI
EPSS
VEX
Summary
Dell PowerFlex Manager, Version prior to 5.1.0.1, contain(s) an Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability during OS Repository processing to achieve arbitrary command execution as root, potentially leading to full appliance compromise and lateral movement into managed infrastructure.
Severity
9.1 (Critical)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00047753… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | PowerFlex Manager |
Affected:
0 , < 5.1.0.1 or later
(semver)
Affected: 0 , < 4.5.5.2 or later (semver) |
Date Public
2026-07-06 06:30
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-56688",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-07-10T16:49:45.463721Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-07-10T17:01:12.022Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerFlex Manager",
"vendor": "Dell",
"versions": [
{
"lessThan": "5.1.0.1 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "4.5.5.2 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"datePublic": "2026-07-06T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerFlex Manager, Version prior to 5.1.0.1, contain(s) an Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability during OS Repository processing to achieve arbitrary command execution as root, potentially leading to full appliance compromise and lateral movement into managed infrastructure."
}
],
"value": "Dell PowerFlex Manager, Version prior to 5.1.0.1, contain(s) an Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability during OS Repository processing to achieve arbitrary command execution as root, potentially leading to full appliance compromise and lateral movement into managed infrastructure."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-10T11:57:41.752Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000477538/dsa-2026-066-security-update-for-powerflex-software-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-56688",
"datePublished": "2026-07-10T11:57:41.752Z",
"dateReserved": "2026-06-22T17:04:26.238Z",
"dateUpdated": "2026-07-10T17:01:12.022Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"vulnerability-lookup:meta": {
"nvd": "{\"cve\":{\"id\":\"CVE-2026-56688\",\"sourceIdentifier\":\"security_alert@emc.com\",\"published\":\"2026-07-10T12:17:23.453\",\"lastModified\":\"2026-07-10T17:17:01.213\",\"vulnStatus\":\"Undergoing Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Dell PowerFlex Manager, Version prior to 5.1.0.1, contain(s) an Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability during OS Repository processing to achieve arbitrary command execution as root, potentially leading to full appliance compromise and lateral movement into managed infrastructure.\"}],\"affected\":[{\"source\":\"security_alert@emc.com\",\"affectedData\":[{\"vendor\":\"Dell\",\"product\":\"PowerFlex Manager\",\"defaultStatus\":\"unaffected\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"5.1.0.1 or later\",\"versionType\":\"semver\",\"status\":\"affected\"},{\"version\":\"0\",\"lessThan\":\"4.5.5.2 or later\",\"versionType\":\"semver\",\"status\":\"affected\"}]}]}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"security_alert@emc.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H\",\"baseScore\":9.1,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.3,\"impactScore\":6.0}],\"ssvcV203\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"ssvcData\":{\"timestamp\":\"2026-07-10T16:49:45.463721Z\",\"id\":\"CVE-2026-56688\",\"options\":[{\"exploitation\":\"none\"},{\"automatable\":\"no\"},{\"technicalImpact\":\"total\"}],\"role\":\"CISA Coordinator\",\"version\":\"2.0.3\"}}]},\"weaknesses\":[{\"source\":\"security_alert@emc.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-78\"}]}],\"references\":[{\"url\":\"https://www.dell.com/support/kbdoc/en-us/000477538/dsa-2026-066-security-update-for-powerflex-software-multiple-vulnerabilities\",\"source\":\"security_alert@emc.com\"}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2026-56688\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2026-07-10T16:49:45.463721Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2026-07-10T16:49:54.255Z\"}}], \"cna\": {\"source\": {\"discovery\": \"UNKNOWN\"}, \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"CHANGED\", \"version\": \"3.1\", \"baseScore\": 9.1, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"CRITICAL\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"HIGH\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Dell\", \"product\": \"PowerFlex Manager\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"5.1.0.1 or later\", \"versionType\": \"semver\"}, {\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"4.5.5.2 or later\", \"versionType\": \"semver\"}], \"defaultStatus\": \"unaffected\"}], \"datePublic\": \"2026-07-06T06:30:00.000Z\", \"references\": [{\"url\": \"https://www.dell.com/support/kbdoc/en-us/000477538/dsa-2026-066-security-update-for-powerflex-software-multiple-vulnerabilities\", \"tags\": [\"vendor-advisory\"]}], \"x_generator\": {\"engine\": \"Vulnogram 1.0.2\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"Dell PowerFlex Manager, Version prior to 5.1.0.1, contain(s) an Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability during OS Repository processing to achieve arbitrary command execution as root, potentially leading to full appliance compromise and lateral movement into managed infrastructure.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"Dell PowerFlex Manager, Version prior to 5.1.0.1, contain(s) an Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability during OS Repository processing to achieve arbitrary command execution as root, potentially leading to full appliance compromise and lateral movement into managed infrastructure.\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-78\", \"description\": \"CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\"}]}], \"providerMetadata\": {\"orgId\": \"c550e75a-17ff-4988-97f0-544cde3820fe\", \"shortName\": \"dell\", \"dateUpdated\": \"2026-07-10T11:57:41.752Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2026-56688\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2026-07-10T17:01:12.022Z\", \"dateReserved\": \"2026-06-22T17:04:26.238Z\", \"assignerOrgId\": \"c550e75a-17ff-4988-97f0-544cde3820fe\", \"datePublished\": \"2026-07-10T11:57:41.752Z\", \"assignerShortName\": \"dell\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
}
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…