CVE-2026-3560 (GCVE-0-2026-3560)
Vulnerability from cvelistv5 – Published: 2026-03-13 20:37 – Updated: 2026-03-16 20:20- CWE-122 - Heap-based Buffer Overflow
| URL | Tags |
|---|---|
| https://www.zerodayinitiative.com/advisories/ZDI-… | x_research-advisory |
| Vendor | Product | Version | CPE status | |
|---|---|---|---|---|
| Philips | Hue Bridge |
Affected:
1.73.1973146020
|
guessed |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-3560",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-03-16T20:20:11.397148Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-03-16T20:20:23.327Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Hue Bridge",
"vendor": "Philips",
"versions": [
{
"status": "affected",
"version": "1.73.1973146020"
}
]
}
],
"dateAssigned": "2026-03-04T19:42:49.535Z",
"datePublic": "2026-03-06T21:19:32.778Z",
"descriptions": [
{
"lang": "en",
"value": "Philips Hue Bridge HomeKit hk_hap_pair_storage_put Heap-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the hk_hap_pair_storage_put function of the HomeKit implementation, which listens on TCP port 8080 by default. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the device. Was ZDI-CAN-28469."
}
],
"metrics": [
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"format": "CVSS"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "CWE-122: Heap-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-03-13T20:37:01.412Z",
"orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"shortName": "zdi"
},
"references": [
{
"name": "ZDI-26-158",
"tags": [
"x_research-advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-26-158/"
}
],
"source": {
"lang": "en",
"value": "Xilokar (@xilokar@mamot.fr)"
},
"title": "Philips Hue Bridge HomeKit hk_hap_pair_storage_put Heap-based Buffer Overflow Remote Code Execution Vulnerability"
}
},
"cveMetadata": {
"assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"assignerShortName": "zdi",
"cveId": "CVE-2026-3560",
"datePublished": "2026-03-13T20:37:01.412Z",
"dateReserved": "2026-03-04T19:42:49.491Z",
"dateUpdated": "2026-03-16T20:20:23.327Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2026-3560",
"date": "2026-11-27",
"epss": "0.00729",
"percentile": "0.50215"
},
"nvd": {
"cve": {
"affected": [
{
"affectedData": [
{
"defaultStatus": "unknown",
"product": "Hue Bridge",
"vendor": "Philips",
"versions": [
{
"status": "affected",
"version": "1.73.1973146020"
}
]
}
],
"source": "zdi-disclosures@trendmicro.com"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:philips:hue_bridge_v2_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C4C925A5-D9FB-482D-A98D-F879B1BD21EC",
"versionEndExcluding": "1975170000",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:philips:hue_bridge_v2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "55B37D18-3A59-423E-9D73-F80DFDB14C4D",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Philips Hue Bridge HomeKit hk_hap_pair_storage_put Heap-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the hk_hap_pair_storage_put function of the HomeKit implementation, which listens on TCP port 8080 by default. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the device. Was ZDI-CAN-28469."
},
{
"lang": "es",
"value": "Vulnerabilidad de ejecuci\u00f3n remota de c\u00f3digo por desbordamiento de b\u00fafer basado en mont\u00edculo hk_hap_pair_storage_put de HomeKit en Philips Hue Bridge. Esta vulnerabilidad permite a atacantes adyacentes a la red ejecutar c\u00f3digo arbitrario en instalaciones afectadas de Philips Hue Bridge. La autenticaci\u00f3n no es necesaria para explotar esta vulnerabilidad.\n\nLa falla espec\u00edfica existe dentro de la funci\u00f3n hk_hap_pair_storage_put de la implementaci\u00f3n de HomeKit, que escucha en el puerto TCP 8080 por defecto. El problema resulta de la falta de validaci\u00f3n adecuada de la longitud de los datos proporcionados por el usuario antes de copiarlos a un b\u00fafer basado en mont\u00edculo. Un atacante puede aprovechar esta vulnerabilidad para ejecutar c\u00f3digo en el contexto del dispositivo. Fue ZDI-CAN-28469."
}
],
"id": "CVE-2026-3560",
"lastModified": "2026-06-17T10:43:47.333",
"metrics": {
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "zdi-disclosures@trendmicro.com",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2026-3560",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-03-16T20:20:11.397148Z",
"version": "2.0.3"
}
}
]
},
"published": "2026-03-16T14:19:52.050",
"references": [
{
"source": "zdi-disclosures@trendmicro.com",
"tags": [
"Third Party Advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-26-158/"
}
],
"sourceIdentifier": "zdi-disclosures@trendmicro.com",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-122"
}
],
"source": "zdi-disclosures@trendmicro.com",
"type": "Secondary"
}
]
}
},
"redhat_vex": {
"current_release_date": "2026-03-27T07:36:27+00:00",
"cve": "CVE-2026-3560",
"id": "CVE-2026-3560",
"initial_release_date": "2026-03-06T21:19:32.778000+00:00",
"product_status:known_not_affected": "1",
"source": "Red Hat CSAF VEX",
"status": "final",
"title": "Philips Hue Bridge HomeKit hk_hap_pair_storage_put Heap-based Buffer Overflow Remote Code Execution Vulnerability",
"url": "https://security.access.redhat.com/data/csaf/v2/vex/2026/cve-2026-3560.json",
"version": "3"
},
"vulnrichment": {
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-3560",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-03-16T20:20:11.397148Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-03-16T20:20:18.566Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Hue Bridge",
"vendor": "Philips",
"versions": [
{
"status": "affected",
"version": "1.73.1973146020"
}
]
}
],
"dateAssigned": "2026-03-04T19:42:49.535Z",
"datePublic": "2026-03-06T21:19:32.778Z",
"descriptions": [
{
"lang": "en",
"value": "Philips Hue Bridge HomeKit hk_hap_pair_storage_put Heap-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the hk_hap_pair_storage_put function of the HomeKit implementation, which listens on TCP port 8080 by default. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the device. Was ZDI-CAN-28469."
}
],
"metrics": [
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"format": "CVSS"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "CWE-122: Heap-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-03-13T20:37:01.412Z",
"orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"shortName": "zdi"
},
"references": [
{
"name": "ZDI-26-158",
"tags": [
"x_research-advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-26-158/"
}
],
"source": {
"lang": "en",
"value": "Xilokar (@xilokar@mamot.fr)"
},
"title": "Philips Hue Bridge HomeKit hk_hap_pair_storage_put Heap-based Buffer Overflow Remote Code Execution Vulnerability"
}
},
"cveMetadata": {
"assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"assignerShortName": "zdi",
"cveId": "CVE-2026-3560",
"datePublished": "2026-03-13T20:37:01.412Z",
"dateReserved": "2026-03-04T19:42:49.491Z",
"dateUpdated": "2026-03-16T20:20:23.327Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
}
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation. The method is described in a publication.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.