CVE-2026-27514 (GCVE-0-2026-27514)

Vulnerability from cvelistv5 – Published: 2026-02-23 16:27 – Updated: 2026-05-11 23:11
VLAI
Title
Tenda F3 Plaintext Credential Exposure in Configuration Download
Summary
Shenzhen Tenda F3 Wireless Router firmware V12.01.01.55_multi contains a sensitive information exposure vulnerability in the configuration download functionality. The configuration download response includes the router password and administrative password in plaintext. The endpoint also omits appropriate Cache-Control directives, which can allow the response to be stored in client-side caches and recovered by other local users or processes with access to cached browser data.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-02-23 18:29 UTC
CWE
  • CWE-201 - Insertion of Sensitive Information Into Sent Data
  • CWE-525 - Use of Web Browser Cache Containing Sensitive Information
Assigner
VulnCheck CNA under the mitre root
CNA scorecard B 84/100 over 7808 records in the last 180 days details
References
Impacted products
Vendor Product Version CPE status
Shenzhen Tenda Technology Co., Ltd. Tenda F3 Affected: 0 , ≤ 12.01.01.55_multi (custom)
    cpe:2.3:o:tenda:f3_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-27514",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-02-23T18:29:06.264210Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-02-23T18:31:35.987Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Tenda F3",
          "vendor": "Shenzhen Tenda Technology Co., Ltd.",
          "versions": [
            {
              "lessThanOrEqual": "12.01.01.55_multi",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "cpeApplicability": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:tenda:f3_firmware:*:*:*:*:*:*:*:*",
                  "versionEndIncluding": "12.01.01.55_multi",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Kazuma Matsumoto, a security researcher at GMO Cybersecurity by IERAE, Inc."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Shenzhen Tenda F3 \u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eWireless Router\u003c/span\u003e\u0026nbsp;firmware V12.01.01.55_multi contains a sensitive information exposure vulnerability in the configuration download functionality. The configuration download response includes the router password and administrative password in plaintext. The endpoint also omits appropriate Cache-Control directives, which can allow the response to be stored in client-side caches and recovered by other local users or processes with access to cached browser data."
            }
          ],
          "value": "Shenzhen Tenda F3 Wireless Router\u00a0firmware V12.01.01.55_multi contains a sensitive information exposure vulnerability in the configuration download functionality. The configuration download response includes the router password and administrative password in plaintext. The endpoint also omits appropriate Cache-Control directives, which can allow the response to be stored in client-side caches and recovered by other local users or processes with access to cached browser data."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-201",
              "description": "CWE-201: Insertion of Sensitive Information Into Sent Data",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-525",
              "description": "CWE-525: Use of Web Browser Cache Containing Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-05-11T23:11:27.235Z",
        "orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
        "shortName": "VulnCheck"
      },
      "references": [
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tendacn.com/product/F3"
        },
        {
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://www.vulncheck.com/advisories/tenda-f3-plaintext-credential-exposure-in-configuration-download"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Tenda F3 Plaintext Credential Exposure in Configuration Download",
      "x_generator": {
        "engine": "Vulnogram 0.5.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
    "assignerShortName": "VulnCheck",
    "cveId": "CVE-2026-27514",
    "datePublished": "2026-02-23T16:27:38.171Z",
    "dateReserved": "2026-02-19T19:51:07.328Z",
    "dateUpdated": "2026-05-11T23:11:27.235Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2026-27514",
      "date": "2026-11-10",
      "epss": "0.00251",
      "percentile": "0.1659"
    },
    "nvd": {
      "cve": {
        "affected": [
          {
            "affectedData": [
              {
                "defaultStatus": "unknown",
                "product": "Tenda F3",
                "vendor": "Shenzhen Tenda Technology Co., Ltd.",
                "versions": [
                  {
                    "lessThanOrEqual": "12.01.01.55_multi",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "source": "disclosure@vulncheck.com"
          }
        ],
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:tenda:f3_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "C94698A5-D2EE-45CD-AB06-4BD30F252920",
                    "versionEndIncluding": "12.01.01.55_multi",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:tenda:f3:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "EE9480BB-FC48-4614-A003-A991109FBCAF",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "Shenzhen Tenda F3 Wireless Router\u00a0firmware V12.01.01.55_multi contains a sensitive information exposure vulnerability in the configuration download functionality. The configuration download response includes the router password and administrative password in plaintext. The endpoint also omits appropriate Cache-Control directives, which can allow the response to be stored in client-side caches and recovered by other local users or processes with access to cached browser data."
          },
          {
            "lang": "es",
            "value": "El firmware V12.01.01.55_multi del Router inal\u00e1mbrico Shenzhen Tenda F3 contiene una vulnerabilidad de exposici\u00f3n de informaci\u00f3n sensible en la funcionalidad de descarga de configuraci\u00f3n. La respuesta de descarga de configuraci\u00f3n incluye la contrase\u00f1a del router y la contrase\u00f1a de administraci\u00f3n en texto plano. El endpoint tambi\u00e9n omite directivas Cache-Control apropiadas, lo que puede permitir que la respuesta sea almacenada en cach\u00e9s del lado del cliente y recuperada por otros usuarios locales o procesos con acceso a datos de navegador en cach\u00e9."
          }
        ],
        "id": "CVE-2026-27514",
        "lastModified": "2026-06-17T10:27:17.240",
        "metrics": {
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              },
              "exploitabilityScore": 2.8,
              "impactScore": 3.6,
              "source": "disclosure@vulncheck.com",
              "type": "Secondary"
            }
          ],
          "cvssMetricV40": [
            {
              "cvssData": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "availabilityRequirement": "NOT_DEFINED",
                "baseScore": 7.1,
                "baseSeverity": "HIGH",
                "confidentialityRequirement": "NOT_DEFINED",
                "exploitMaturity": "NOT_DEFINED",
                "integrityRequirement": "NOT_DEFINED",
                "modifiedAttackComplexity": "NOT_DEFINED",
                "modifiedAttackRequirements": "NOT_DEFINED",
                "modifiedAttackVector": "NOT_DEFINED",
                "modifiedPrivilegesRequired": "NOT_DEFINED",
                "modifiedSubAvailabilityImpact": "NOT_DEFINED",
                "modifiedSubConfidentialityImpact": "NOT_DEFINED",
                "modifiedSubIntegrityImpact": "NOT_DEFINED",
                "modifiedUserInteraction": "NOT_DEFINED",
                "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
                "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
                "modifiedVulnIntegrityImpact": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "source": "disclosure@vulncheck.com",
              "type": "Secondary"
            }
          ],
          "ssvcV203": [
            {
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "ssvcData": {
                "id": "CVE-2026-27514",
                "options": [
                  {
                    "exploitation": "none"
                  },
                  {
                    "automatable": "no"
                  },
                  {
                    "technicalImpact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-02-23T18:29:06.264210Z",
                "version": "2.0.3"
              }
            }
          ]
        },
        "published": "2026-02-23T17:23:30.087",
        "references": [
          {
            "source": "disclosure@vulncheck.com",
            "tags": [
              "Product"
            ],
            "url": "https://www.tendacn.com/product/F3"
          },
          {
            "source": "disclosure@vulncheck.com",
            "tags": [
              "Third Party Advisory"
            ],
            "url": "https://www.vulncheck.com/advisories/tenda-f3-plaintext-credential-exposure-in-configuration-download"
          }
        ],
        "sourceIdentifier": "disclosure@vulncheck.com",
        "vulnStatus": "Analyzed",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-201"
              },
              {
                "lang": "en",
                "value": "CWE-525"
              }
            ],
            "source": "disclosure@vulncheck.com",
            "type": "Secondary"
          }
        ]
      }
    },
    "redhat_vex": {
      "current_release_date": "2026-03-27T07:54:47+00:00",
      "cve": "CVE-2026-27514",
      "id": "CVE-2026-27514",
      "initial_release_date": "2026-01-01T00:00:00+00:00",
      "product_status:known_not_affected": "1",
      "source": "Red Hat CSAF VEX",
      "status": "final",
      "title": "Tenda F3 Plaintext Credential Exposure in Configuration Download",
      "url": "https://security.access.redhat.com/data/csaf/v2/vex/2026/cve-2026-27514.json",
      "version": "3"
    },
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-27514",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-02-23T18:29:06.264210Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-23T18:30:37.444Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Tenda F3",
              "vendor": "Shenzhen Tenda Technology Co., Ltd.",
              "versions": [
                {
                  "lessThanOrEqual": "12.01.01.55_multi",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Kazuma Matsumoto, a security researcher at GMO Cybersecurity by IERAE, Inc."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Shenzhen Tenda F3 \u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eWireless Router\u003c/span\u003e\u0026nbsp;firmware V12.01.01.55_multi contains a sensitive information exposure vulnerability in the configuration download functionality. The configuration download response includes the router password and administrative password in plaintext. The endpoint also omits appropriate Cache-Control directives, which can allow the response to be stored in client-side caches and recovered by other local users or processes with access to cached browser data."
                }
              ],
              "value": "Shenzhen Tenda F3 Wireless Router\u00a0firmware V12.01.01.55_multi contains a sensitive information exposure vulnerability in the configuration download functionality. The configuration download response includes the router password and administrative password in plaintext. The endpoint also omits appropriate Cache-Control directives, which can allow the response to be stored in client-side caches and recovered by other local users or processes with access to cached browser data."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 7.1,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-201",
                  "description": "CWE-201: Insertion of Sensitive Information Into Sent Data",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-525",
                  "description": "CWE-525: Use of Web Browser Cache Containing Sensitive Information",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-23T16:27:38.171Z",
            "orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
            "shortName": "VulnCheck"
          },
          "references": [
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tendacn.com/product/F3"
            },
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.vulncheck.com/advisories/tenda-f3-plaintext-credential-exposure-in-configuration-download"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Tenda F3 Plaintext Credential Exposure in Configuration Download",
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
        "assignerShortName": "VulnCheck",
        "cveId": "CVE-2026-27514",
        "datePublished": "2026-02-23T16:27:38.171Z",
        "dateReserved": "2026-02-19T19:51:07.328Z",
        "dateUpdated": "2026-02-23T18:31:35.987Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline

Sightings and recorded dates, grouped by day · UTC

JSON
How durations are calculated

Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.

Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.

Events included in the timeline

Loading timeline…


    Loading…

    Loading…

    Loading…

    Related by attack behaviour

    Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.