ELECOM wireless LAN access point devices use a hard-coded cryptographic key when creating backups of configuration files. An attacker who knows the encryption key can tamper the configuration file of the product, and a victim administrator may be tricked to use a crafted configuration file.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-05-13 18:26 UTC
CWE
  • CWE-321 - Use of hard-coded cryptographic key
Assigner
jpcert CNA under the jpcert root
CNA scorecard C 64/100 over 193 records in the last 180 days details
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-25107",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-05-13T18:26:16.594153Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-05-13T18:26:26.218Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "WRC-X1800GS-B",
          "vendor": "ELECOM CO.,LTD.",
          "versions": [
            {
              "status": "affected",
              "version": "v1.19 and earlier"
            }
          ]
        },
        {
          "product": "WRC-X3000GS2-B",
          "vendor": "ELECOM CO.,LTD.",
          "versions": [
            {
              "status": "affected",
              "version": "v1.09 and earlier"
            }
          ]
        },
        {
          "product": "WRC-X3000GS2-W",
          "vendor": "ELECOM CO.,LTD.",
          "versions": [
            {
              "status": "affected",
              "version": "v1.09 and earlier"
            }
          ]
        },
        {
          "product": "WRC-X3000GS2A-B",
          "vendor": "ELECOM CO.,LTD.",
          "versions": [
            {
              "status": "affected",
              "version": "v1.09 and earlier"
            }
          ]
        },
        {
          "product": "WRC-X3000GST2-B",
          "vendor": "ELECOM CO.,LTD.",
          "versions": [
            {
              "status": "affected",
              "version": "v1.06 and earlier"
            }
          ]
        },
        {
          "product": "WRC-X1800GSA-B",
          "vendor": "ELECOM CO.,LTD.",
          "versions": [
            {
              "status": "affected",
              "version": "v1.19 and earlier"
            }
          ]
        },
        {
          "product": "WRC-X1800GSH-B",
          "vendor": "ELECOM CO.,LTD.",
          "versions": [
            {
              "status": "affected",
              "version": "v1.19 and earlier"
            }
          ]
        },
        {
          "product": "WRC-X6000QS-G",
          "vendor": "ELECOM CO.,LTD.",
          "versions": [
            {
              "status": "affected",
              "version": "v1.14 and earlier"
            }
          ]
        },
        {
          "product": "WRC-X6000QSA-G",
          "vendor": "ELECOM CO.,LTD.",
          "versions": [
            {
              "status": "affected",
              "version": "v1.14 and earlier"
            }
          ]
        },
        {
          "product": "WRC-X6000XS-G",
          "vendor": "ELECOM CO.,LTD.",
          "versions": [
            {
              "status": "affected",
              "version": "v1.12 and earlier"
            }
          ]
        },
        {
          "product": "WRC-X6000XST-G",
          "vendor": "ELECOM CO.,LTD.",
          "versions": [
            {
              "status": "affected",
              "version": "v1.16 and earlier"
            }
          ]
        },
        {
          "product": "WRC-XE5400GS-G",
          "vendor": "ELECOM CO.,LTD.",
          "versions": [
            {
              "status": "affected",
              "version": "1.13 and earlier"
            }
          ]
        },
        {
          "product": "WRC-XE5400GSA-G",
          "vendor": "ELECOM CO.,LTD.",
          "versions": [
            {
              "status": "affected",
              "version": "v1.13 and earlier"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "ELECOM wireless LAN access point devices use a hard-coded cryptographic key when creating backups of configuration files. An attacker who knows the encryption key can tamper the configuration file of the product, and a victim administrator may be tricked to use a crafted configuration file."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:N",
            "version": "3.0"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en-US",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "baseScore": 6.9,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en-US",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-321",
              "description": "Use of hard-coded cryptographic key",
              "lang": "en-US",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-05-13T12:01:20.724Z",
        "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "shortName": "jpcert"
      },
      "references": [
        {
          "url": "https://www.elecom.co.jp/news/security/20260512-01/"
        },
        {
          "url": "https://jvn.jp/en/jp/JVN03037325/"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
    "assignerShortName": "jpcert",
    "cveId": "CVE-2026-25107",
    "datePublished": "2026-05-13T12:01:20.724Z",
    "dateReserved": "2026-05-07T05:47:06.075Z",
    "dateUpdated": "2026-05-13T18:26:26.218Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2026-25107",
      "date": "2026-11-06",
      "epss": "0.00124",
      "percentile": "0.02146"
    },
    "nvd": {
      "cve": {
        "affected": [
          {
            "affectedData": [
              {
                "product": "WRC-X1800GS-B",
                "vendor": "ELECOM CO.,LTD.",
                "versions": [
                  {
                    "status": "affected",
                    "version": "v1.19 and earlier"
                  }
                ]
              },
              {
                "product": "WRC-X3000GS2-B",
                "vendor": "ELECOM CO.,LTD.",
                "versions": [
                  {
                    "status": "affected",
                    "version": "v1.09 and earlier"
                  }
                ]
              },
              {
                "product": "WRC-X3000GS2-W",
                "vendor": "ELECOM CO.,LTD.",
                "versions": [
                  {
                    "status": "affected",
                    "version": "v1.09 and earlier"
                  }
                ]
              },
              {
                "product": "WRC-X3000GS2A-B",
                "vendor": "ELECOM CO.,LTD.",
                "versions": [
                  {
                    "status": "affected",
                    "version": "v1.09 and earlier"
                  }
                ]
              },
              {
                "product": "WRC-X3000GST2-B",
                "vendor": "ELECOM CO.,LTD.",
                "versions": [
                  {
                    "status": "affected",
                    "version": "v1.06 and earlier"
                  }
                ]
              },
              {
                "product": "WRC-X1800GSA-B",
                "vendor": "ELECOM CO.,LTD.",
                "versions": [
                  {
                    "status": "affected",
                    "version": "v1.19 and earlier"
                  }
                ]
              },
              {
                "product": "WRC-X1800GSH-B",
                "vendor": "ELECOM CO.,LTD.",
                "versions": [
                  {
                    "status": "affected",
                    "version": "v1.19 and earlier"
                  }
                ]
              },
              {
                "product": "WRC-X6000QS-G",
                "vendor": "ELECOM CO.,LTD.",
                "versions": [
                  {
                    "status": "affected",
                    "version": "v1.14 and earlier"
                  }
                ]
              },
              {
                "product": "WRC-X6000QSA-G",
                "vendor": "ELECOM CO.,LTD.",
                "versions": [
                  {
                    "status": "affected",
                    "version": "v1.14 and earlier"
                  }
                ]
              },
              {
                "product": "WRC-X6000XS-G",
                "vendor": "ELECOM CO.,LTD.",
                "versions": [
                  {
                    "status": "affected",
                    "version": "v1.12 and earlier"
                  }
                ]
              },
              {
                "product": "WRC-X6000XST-G",
                "vendor": "ELECOM CO.,LTD.",
                "versions": [
                  {
                    "status": "affected",
                    "version": "v1.16 and earlier"
                  }
                ]
              },
              {
                "product": "WRC-XE5400GS-G",
                "vendor": "ELECOM CO.,LTD.",
                "versions": [
                  {
                    "status": "affected",
                    "version": "1.13 and earlier"
                  }
                ]
              },
              {
                "product": "WRC-XE5400GSA-G",
                "vendor": "ELECOM CO.,LTD.",
                "versions": [
                  {
                    "status": "affected",
                    "version": "v1.13 and earlier"
                  }
                ]
              }
            ],
            "source": "vultures@jpcert.or.jp"
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "ELECOM wireless LAN access point devices use a hard-coded cryptographic key when creating backups of configuration files. An attacker who knows the encryption key can tamper the configuration file of the product, and a victim administrator may be tricked to use a crafted configuration file."
          },
          {
            "lang": "es",
            "value": "Los dispositivos de punto de acceso LAN inal\u00e1mbrica ELECOM utilizan una clave criptogr\u00e1fica codificada de forma r\u00edgida al crear copias de seguridad de archivos de configuraci\u00f3n. Un atacante que conoce la clave de cifrado puede manipular el archivo de configuraci\u00f3n del producto, y un administrador v\u00edctima puede ser enga\u00f1ado para usar un archivo de configuraci\u00f3n manipulado."
          }
        ],
        "id": "CVE-2026-25107",
        "lastModified": "2026-10-26T14:10:00.130",
        "metrics": {
          "cvssMetricV30": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:N",
                "version": "3.0"
              },
              "exploitabilityScore": 2.8,
              "impactScore": 3.6,
              "source": "vultures@jpcert.or.jp",
              "type": "Secondary"
            }
          ],
          "cvssMetricV40": [
            {
              "cvssData": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "availabilityRequirement": "NOT_DEFINED",
                "baseScore": 6.9,
                "baseSeverity": "MEDIUM",
                "confidentialityRequirement": "NOT_DEFINED",
                "exploitMaturity": "NOT_DEFINED",
                "integrityRequirement": "NOT_DEFINED",
                "modifiedAttackComplexity": "NOT_DEFINED",
                "modifiedAttackRequirements": "NOT_DEFINED",
                "modifiedAttackVector": "NOT_DEFINED",
                "modifiedPrivilegesRequired": "NOT_DEFINED",
                "modifiedSubAvailabilityImpact": "NOT_DEFINED",
                "modifiedSubConfidentialityImpact": "NOT_DEFINED",
                "modifiedSubIntegrityImpact": "NOT_DEFINED",
                "modifiedUserInteraction": "NOT_DEFINED",
                "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
                "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
                "modifiedVulnIntegrityImpact": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "ACTIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "source": "vultures@jpcert.or.jp",
              "type": "Secondary"
            }
          ],
          "ssvcV203": [
            {
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "ssvcData": {
                "id": "CVE-2026-25107",
                "options": [
                  {
                    "exploitation": "none"
                  },
                  {
                    "automatable": "no"
                  },
                  {
                    "technicalImpact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-05-13T18:26:16.594153Z",
                "version": "2.0.3"
              }
            }
          ]
        },
        "published": "2026-05-13T13:16:37.160",
        "references": [
          {
            "source": "vultures@jpcert.or.jp",
            "url": "https://jvn.jp/en/jp/JVN03037325/"
          },
          {
            "source": "vultures@jpcert.or.jp",
            "url": "https://www.elecom.co.jp/news/security/20260512-01/"
          }
        ],
        "sourceIdentifier": "vultures@jpcert.or.jp",
        "vulnStatus": "Deferred",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-321"
              }
            ],
            "source": "vultures@jpcert.or.jp",
            "type": "Secondary"
          }
        ]
      }
    },
    "redhat_vex": {
      "current_release_date": "2026-06-05T19:40:18+00:00",
      "cve": "CVE-2026-25107",
      "id": "CVE-2026-25107",
      "initial_release_date": "2026-01-01T00:00:00+00:00",
      "product_status:known_not_affected": "1",
      "source": "Red Hat CSAF VEX",
      "status": "final",
      "title": "CVE-2026-25107",
      "url": "https://security.access.redhat.com/data/csaf/v2/vex/2026/cve-2026-25107.json",
      "version": "3"
    },
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-25107",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-05-13T18:26:16.594153Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-05-13T18:26:22.969Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "WRC-X1800GS-B",
              "vendor": "ELECOM CO.,LTD.",
              "versions": [
                {
                  "status": "affected",
                  "version": "v1.19 and earlier"
                }
              ]
            },
            {
              "product": "WRC-X3000GS2-B",
              "vendor": "ELECOM CO.,LTD.",
              "versions": [
                {
                  "status": "affected",
                  "version": "v1.09 and earlier"
                }
              ]
            },
            {
              "product": "WRC-X3000GS2-W",
              "vendor": "ELECOM CO.,LTD.",
              "versions": [
                {
                  "status": "affected",
                  "version": "v1.09 and earlier"
                }
              ]
            },
            {
              "product": "WRC-X3000GS2A-B",
              "vendor": "ELECOM CO.,LTD.",
              "versions": [
                {
                  "status": "affected",
                  "version": "v1.09 and earlier"
                }
              ]
            },
            {
              "product": "WRC-X3000GST2-B",
              "vendor": "ELECOM CO.,LTD.",
              "versions": [
                {
                  "status": "affected",
                  "version": "v1.06 and earlier"
                }
              ]
            },
            {
              "product": "WRC-X1800GSA-B",
              "vendor": "ELECOM CO.,LTD.",
              "versions": [
                {
                  "status": "affected",
                  "version": "v1.19 and earlier"
                }
              ]
            },
            {
              "product": "WRC-X1800GSH-B",
              "vendor": "ELECOM CO.,LTD.",
              "versions": [
                {
                  "status": "affected",
                  "version": "v1.19 and earlier"
                }
              ]
            },
            {
              "product": "WRC-X6000QS-G",
              "vendor": "ELECOM CO.,LTD.",
              "versions": [
                {
                  "status": "affected",
                  "version": "v1.14 and earlier"
                }
              ]
            },
            {
              "product": "WRC-X6000QSA-G",
              "vendor": "ELECOM CO.,LTD.",
              "versions": [
                {
                  "status": "affected",
                  "version": "v1.14 and earlier"
                }
              ]
            },
            {
              "product": "WRC-X6000XS-G",
              "vendor": "ELECOM CO.,LTD.",
              "versions": [
                {
                  "status": "affected",
                  "version": "v1.12 and earlier"
                }
              ]
            },
            {
              "product": "WRC-X6000XST-G",
              "vendor": "ELECOM CO.,LTD.",
              "versions": [
                {
                  "status": "affected",
                  "version": "v1.16 and earlier"
                }
              ]
            },
            {
              "product": "WRC-XE5400GS-G",
              "vendor": "ELECOM CO.,LTD.",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.13 and earlier"
                }
              ]
            },
            {
              "product": "WRC-XE5400GSA-G",
              "vendor": "ELECOM CO.,LTD.",
              "versions": [
                {
                  "status": "affected",
                  "version": "v1.13 and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "ELECOM wireless LAN access point devices use a hard-coded cryptographic key when creating backups of configuration files. An attacker who knows the encryption key can tamper the configuration file of the product, and a victim administrator may be tricked to use a crafted configuration file."
            }
          ],
          "metrics": [
            {
              "cvssV3_0": {
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:N",
                "version": "3.0"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en-US",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "baseScore": 6.9,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en-US",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-321",
                  "description": "Use of hard-coded cryptographic key",
                  "lang": "en-US",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-05-13T12:01:20.724Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "url": "https://www.elecom.co.jp/news/security/20260512-01/"
            },
            {
              "url": "https://jvn.jp/en/jp/JVN03037325/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2026-25107",
        "datePublished": "2026-05-13T12:01:20.724Z",
        "dateReserved": "2026-05-07T05:47:06.075Z",
        "dateUpdated": "2026-05-13T18:26:26.218Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline

Sightings and recorded dates, grouped by day · UTC

JSON
Events included in the timeline

Loading timeline…


    Loading…

    Loading…

    Loading…

    Related by attack behaviour

    Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.