CVE-2026-22626 (GCVE-0-2026-22626)

Vulnerability from cvelistv5 – Published: 2026-01-30 11:03 – Updated: 2026-02-27 14:37
VLAI
Summary
Due to insufficient input parameter validation on the interface, authenticated users of certain HIKSEMI NAS products can cause abnormal device behavior by crafting specific messages.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
  • CWE-233 - Improper Handling of Parameters
Assigner
Impacted products
Vendor Product Version
HIKSEMI HS-AFS-S1H1 Affected: V5.10.10_Build_251126
Create a notification for this product.
Credits
Jincheng Wang
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-22626",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-01-30T12:40:22.043403Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-233",
                "description": "CWE-233 Improper Handling of Parameters",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-02-27T14:37:37.094Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "HS-AFS-S1H1",
          "vendor": "HIKSEMI",
          "versions": [
            {
              "status": "affected",
              "version": "V5.10.10_Build_251126"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Jincheng Wang"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Due to insufficient input parameter validation on the interface, authenticated users of certain HIKSEMI NAS products can cause abnormal device behavior by crafting specific messages."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 4.9,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-01-30T11:03:29.709Z",
        "orgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
        "shortName": "hikvision"
      },
      "references": [
        {
          "url": "https://www.hiksemitech.com/en/hiksemi/support/security-advisory.html"
        }
      ],
      "x_generator": {
        "engine": "cveClient/1.0.15"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
    "assignerShortName": "hikvision",
    "cveId": "CVE-2026-22626",
    "datePublished": "2026-01-30T11:03:29.709Z",
    "dateReserved": "2026-01-08T05:37:27.997Z",
    "dateUpdated": "2026-02-27T14:37:37.094Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2026-22626",
      "date": "2026-06-27",
      "epss": "0.00378",
      "percentile": "0.29719"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2026-22626\",\"sourceIdentifier\":\"hsrc@hikvision.com\",\"published\":\"2026-01-30T11:15:56.010\",\"lastModified\":\"2026-06-17T10:20:10.977\",\"vulnStatus\":\"Deferred\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Due to insufficient input parameter validation on the interface, authenticated users of certain HIKSEMI NAS products can cause abnormal device behavior by crafting specific messages.\"},{\"lang\":\"es\",\"value\":\"Debido a la validaci\u00f3n insuficiente de par\u00e1metros de entrada en la interfaz, los usuarios autenticados de ciertos productos NAS de HIKSEMI pueden causar un comportamiento an\u00f3malo del dispositivo mediante la elaboraci\u00f3n de mensajes espec\u00edficos.\"}],\"affected\":[{\"source\":\"hsrc@hikvision.com\",\"affectedData\":[{\"vendor\":\"HIKSEMI\",\"product\":\"HS-AFS-S1H1\",\"versions\":[{\"version\":\"V5.10.10_Build_251126\",\"status\":\"affected\"}]}]}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"hsrc@hikvision.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H\",\"baseScore\":4.9,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.2,\"impactScore\":3.6}],\"ssvcV203\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"ssvcData\":{\"timestamp\":\"2026-01-30T12:40:22.043403Z\",\"id\":\"CVE-2026-22626\",\"options\":[{\"exploitation\":\"none\"},{\"automatable\":\"no\"},{\"technicalImpact\":\"partial\"}],\"role\":\"CISA Coordinator\",\"version\":\"2.0.3\"}}]},\"weaknesses\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-233\"}]}],\"references\":[{\"url\":\"https://www.hiksemitech.com/en/hiksemi/support/security-advisory.html\",\"source\":\"hsrc@hikvision.com\"}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2026-22626\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2026-01-30T12:40:22.043403Z\"}}}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-233\", \"description\": \"CWE-233 Improper Handling of Parameters\"}]}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2026-01-30T12:40:39.075Z\"}}], \"cna\": {\"credits\": [{\"lang\": \"en\", \"type\": \"finder\", \"value\": \"Jincheng Wang\"}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 4.9, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H\", \"integrityImpact\": \"NONE\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"HIGH\", \"confidentialityImpact\": \"NONE\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"HIKSEMI\", \"product\": \"HS-AFS-S1H1\", \"versions\": [{\"status\": \"affected\", \"version\": \"V5.10.10_Build_251126\"}]}], \"references\": [{\"url\": \"https://www.hiksemitech.com/en/hiksemi/support/security-advisory.html\"}], \"x_generator\": {\"engine\": \"cveClient/1.0.15\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"Due to insufficient input parameter validation on the interface, authenticated users of certain HIKSEMI NAS products can cause abnormal device behavior by crafting specific messages.\"}], \"providerMetadata\": {\"orgId\": \"da451dce-859b-4e51-8b87-9c8b60d19b32\", \"shortName\": \"hikvision\", \"dateUpdated\": \"2026-01-30T11:03:29.709Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2026-22626\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2026-02-27T14:37:37.094Z\", \"dateReserved\": \"2026-01-08T05:37:27.997Z\", \"assignerOrgId\": \"da451dce-859b-4e51-8b87-9c8b60d19b32\", \"datePublished\": \"2026-01-30T11:03:29.709Z\", \"assignerShortName\": \"hikvision\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…