CVE-2026-1449 (GCVE-0-2026-1449)
Vulnerability from cvelistv5 – Published: 2026-01-26 23:32 – Updated: 2026-02-23 08:59| URL | Tags |
|---|---|
| https://vuldb.com/?id.342881 | vdb-entrytechnical-description |
| https://vuldb.com/?ctiid.342881 | signaturepermissions-required |
| https://vuldb.com/?submit.737032 | third-party-advisory |
| https://github.com/master-abc/cve/issues/15 | exploitissue-tracking |
| Vendor | Product | Version | CPE status | |
|---|---|---|---|---|
| Hisense TransTech | Smart Bus Management System |
Affected:
20260113
|
guessed |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-1449",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-01-27T21:27:17.405778Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-01-27T21:27:30.367Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Smart Bus Management System",
"vendor": "Hisense TransTech",
"versions": [
{
"status": "affected",
"version": "20260113"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "jiefengliang (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A flaw has been found in Hisense TransTech Smart Bus Management System up to 20260113. Affected is the function Page_Load of the file YZSoft/Forms/XForm/BM/BusComManagement/TireMng.aspx. Executing a manipulation of the argument key can lead to sql injection. It is possible to launch the attack remotely. The exploit has been published and may be used. The vendor was contacted early about this disclosure but did not respond in any way."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 7.5,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-89",
"description": "SQL Injection",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-74",
"description": "Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-02-23T08:59:17.016Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-342881 | Hisense TransTech Smart Bus Management System TireMng.aspx Page_Load sql injection",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.342881"
},
{
"name": "VDB-342881 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.342881"
},
{
"name": "Submit #737032 | Hisense TransTech Hisense Smart Bus Management System 1.0 SQL Injection",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.737032"
},
{
"tags": [
"exploit",
"issue-tracking"
],
"url": "https://github.com/master-abc/cve/issues/15"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-01-26T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-01-26T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-01-28T15:43:28.000Z",
"value": "VulDB entry last update"
}
],
"title": "Hisense TransTech Smart Bus Management System TireMng.aspx Page_Load sql injection"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-1449",
"datePublished": "2026-01-26T23:32:10.536Z",
"dateReserved": "2026-01-26T17:44:41.113Z",
"dateUpdated": "2026-02-23T08:59:17.016Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2026-1449",
"date": "2026-11-13",
"epss": "0.00382",
"percentile": "0.32708"
},
"nvd": {
"cve": {
"affected": [
{
"affectedData": [
{
"product": "Smart Bus Management System",
"vendor": "Hisense TransTech",
"versions": [
{
"status": "affected",
"version": "20260113"
}
]
}
],
"source": "cna@vuldb.com"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A flaw has been found in Hisense TransTech Smart Bus Management System up to 20260113. Affected is the function Page_Load of the file YZSoft/Forms/XForm/BM/BusComManagement/TireMng.aspx. Executing a manipulation of the argument key can lead to sql injection. It is possible to launch the attack remotely. The exploit has been published and may be used. The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "es",
"value": "Se ha encontrado una falla en el sistema de gesti\u00f3n de autobuses inteligentes Hisense TransTech hasta el 20260113. Afectada es la funci\u00f3n Page_Load del archivo YZSoft/Forms/XForm/BM/BusComManagement/TireMng.aspx. La ejecuci\u00f3n de una manipulaci\u00f3n del argumento key puede llevar a inyecci\u00f3n SQL. Es posible lanzar el ataque remotamente. El exploit ha sido publicado y puede ser utilizado. Se contact\u00f3 al proveedor con antelaci\u00f3n sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera."
}
],
"id": "CVE-2026-1449",
"lastModified": "2026-06-17T10:15:48.743",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "cna@vuldb.com",
"type": "Secondary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.4,
"source": "cna@vuldb.com",
"type": "Secondary"
}
],
"cvssMetricV40": [
{
"cvssData": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"availabilityRequirement": "NOT_DEFINED",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityRequirement": "NOT_DEFINED",
"exploitMaturity": "PROOF_OF_CONCEPT",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"version": "4.0",
"vulnAvailabilityImpact": "LOW",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "LOW",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"source": "cna@vuldb.com",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2026-1449",
"options": [
{
"exploitation": "poc"
},
{
"automatable": "yes"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-01-27T21:27:17.405778Z",
"version": "2.0.3"
}
}
]
},
"published": "2026-01-27T00:15:50.790",
"references": [
{
"source": "cna@vuldb.com",
"url": "https://github.com/master-abc/cve/issues/15"
},
{
"source": "cna@vuldb.com",
"url": "https://vuldb.com/?ctiid.342881"
},
{
"source": "cna@vuldb.com",
"url": "https://vuldb.com/?id.342881"
},
{
"source": "cna@vuldb.com",
"url": "https://vuldb.com/?submit.737032"
}
],
"sourceIdentifier": "cna@vuldb.com",
"vulnStatus": "Deferred",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-74"
},
{
"lang": "en",
"value": "CWE-89"
}
],
"source": "cna@vuldb.com",
"type": "Secondary"
}
]
}
},
"redhat_vex": {
"current_release_date": "2026-01-28T03:16:50+00:00",
"cve": "CVE-2026-1449",
"id": "CVE-2026-1449",
"initial_release_date": "2026-01-01T00:00:00+00:00",
"product_status:known_not_affected": "1",
"source": "Red Hat CSAF VEX",
"status": "final",
"title": "Hisense TransTech Smart Bus Management System TireMng.aspx Page_Load sql injection",
"url": "https://security.access.redhat.com/data/csaf/v2/vex/2026/cve-2026-1449.json",
"version": "3"
},
"vulnrichment": {
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-1449",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-01-27T21:27:17.405778Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-01-27T21:27:25.750Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Smart Bus Management System",
"vendor": "Hisense TransTech",
"versions": [
{
"status": "affected",
"version": "20260113"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "jiefengliang (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A flaw has been found in Hisense TransTech Smart Bus Management System up to 20260113. Affected is the function Page_Load of the file YZSoft/Forms/XForm/BM/BusComManagement/TireMng.aspx. Executing a manipulation of the argument key can lead to sql injection. It is possible to launch the attack remotely. The exploit has been published and may be used. The vendor was contacted early about this disclosure but did not respond in any way."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 7.3,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 7.5,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-89",
"description": "SQL Injection",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-74",
"description": "Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-02-23T08:59:17.016Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-342881 | Hisense TransTech Smart Bus Management System TireMng.aspx Page_Load sql injection",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.342881"
},
{
"name": "VDB-342881 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.342881"
},
{
"name": "Submit #737032 | Hisense TransTech Hisense Smart Bus Management System 1.0 SQL Injection",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.737032"
},
{
"tags": [
"exploit",
"issue-tracking"
],
"url": "https://github.com/master-abc/cve/issues/15"
}
],
"timeline": [
{
"lang": "en",
"time": "2026-01-26T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2026-01-26T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2026-01-28T15:43:28.000Z",
"value": "VulDB entry last update"
}
],
"title": "Hisense TransTech Smart Bus Management System TireMng.aspx Page_Load sql injection"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2026-1449",
"datePublished": "2026-01-26T23:32:10.536Z",
"dateReserved": "2026-01-26T17:44:41.113Z",
"dateUpdated": "2026-02-23T08:59:17.016Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
}
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.