CVE-2025-8870 (GCVE-0-2025-8870)
Vulnerability from cvelistv5 – Published: 2025-11-14 15:57 – Updated: 2025-11-14 16:29| Vendor | Product | Version | CPE status | |
|---|---|---|---|---|
| Arista Networks | EOS |
Affected:
4.34.2FX
(custom)
cpe:2.3:a:arista_networks:eos:4.34.2fx:*:710x_series:*:*:*:*:* |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-8870",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-11-14T16:28:58.202689Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-11-14T16:29:13.516Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"710X Series"
],
"product": "EOS",
"vendor": "Arista Networks",
"versions": [
{
"status": "affected",
"version": "4.34.2FX",
"versionType": "custom"
}
]
}
],
"configurations": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cb\u003e\u003cp\u003e\u003cspan style=\"background-color: transparent;\"\u003eIn order to be vulnerable to CVE-2025-8870, both of the following conditions must be met:\u003c/span\u003e\u003c/p\u003e\u003cbr\u003e\u003col\u003e\u003cli\u003e\u003cp\u003e\u003cspan style=\"background-color: transparent;\"\u003eAn attacker must have a serial interface connection to the device or access to remotely access the console via the console port. Network remote access does not cause this issue.\u003c/span\u003e\u003c/p\u003e\u003c/li\u003e\u003c/ol\u003e\u003cp\u003e\u003cspan style=\"background-color: transparent;\"\u003eAND\u003c/span\u003e\u003c/p\u003e\u003col\u003e\u003cli\u003e\u003cp\u003e\u003cspan style=\"background-color: transparent;\"\u003eDevice must be using the Synopsys Designware serial model:\u003c/span\u003e\u003c/p\u003e\u003c/li\u003e\u003c/ol\u003e\u003cbr\u003e\u003cdiv\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003e\u003cspan style=\"background-color: transparent;\"\u003e#bash dmesg | grep \"Synopsys DesignWare\"\u003c/span\u003e\u003c/p\u003e\u003cp\u003e\u003cspan style=\"background-color: transparent;\"\u003e[ \u0026nbsp; 1.287358] 10200000.serial: ttyS0 at MMIO 0x10200000 (irq = 15, base_baud = 15625000) is a \u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 0);\"\u003eSynopsys DesignWare\u003c/span\u003e\u003c/p\u003e\u003cp\u003e\u003cspan style=\"background-color: transparent;\"\u003e[ \u0026nbsp; 1.287845] 10201000.serial: ttyS1 at MMIO 0x10201000 (irq = 164, base_baud = 15625000) is a Synopsys DesignWare\u003c/span\u003e\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003c/tbody\u003e\u003c/table\u003e\u003c/div\u003e\u003c/b\u003e\u003cbr\u003e"
}
],
"value": "In order to be vulnerable to CVE-2025-8870, both of the following conditions must be met:\n\n\n * An attacker must have a serial interface connection to the device or access to remotely access the console via the console port. Network remote access does not cause this issue.\n\n\nAND\n\n * Device must be using the Synopsys Designware serial model:\n\n\n\n#bash dmesg | grep \"Synopsys DesignWare\"\n\n[ \u00a0 1.287358] 10200000.serial: ttyS0 at MMIO 0x10200000 (irq = 15, base_baud = 15625000) is a Synopsys DesignWare\n\n[ \u00a0 1.287845] 10201000.serial: ttyS1 at MMIO 0x10201000 (irq = 164, base_baud = 15625000) is a Synopsys DesignWare"
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:arista_networks:eos:4.34.2fx:*:710x_series:*:*:*:*:*",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
}
],
"datePublic": "2025-11-11T14:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cb\u003e\u003cspan style=\"background-color: transparent;\"\u003eOn affected platforms running Arista EOS, certain serial console input might result in an unexpected reload of the device.153\u003c/span\u003e\u003c/b\u003e\u003cbr\u003e"
}
],
"value": "On affected platforms running Arista EOS, certain serial console input might result in an unexpected reload of the device.153"
}
],
"impacts": [
{
"capecId": "CAPEC-153",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-153 Input Data Manipulation"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "PHYSICAL",
"availabilityImpact": "HIGH",
"baseScore": 4.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:P/AC:H/PR:N/UI:N/S:C/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"attackVector": "PHYSICAL",
"baseScore": 5.6,
"baseSeverity": "MEDIUM",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:P/AC:L/AT:P/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-248",
"description": "CWE-248",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-11-14T15:57:04.673Z",
"orgId": "c8b34d1a-69ae-45c3-88fe-f3b3d44f39b7",
"shortName": "Arista"
},
"references": [
{
"url": "https://www.arista.com/en/support/advisories-notices/security-advisory/22811-security-advisory-0125"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cb\u003e\u003cp\u003e\u003cspan style=\"background-color: transparent;\"\u003eThe recommended resolution is to upgrade to a remediated software version at your earliest convenience. Arista recommends customers move to the latest version of each release that contains all the fixes listed below. For more information about upgrading see \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.arista.com/en/um-eos/eos-upgrades-and-downgrades\"\u003e\u003cspan style=\"background-color: transparent;\"\u003eEOS User Manual: Upgrades and Downgrades\u003c/span\u003e\u003c/a\u003e\u003c/p\u003e\u003cbr\u003e\u003cp\u003e\u003cspan style=\"background-color: transparent;\"\u003eCVE-2025-8870 has been fixed in the following releases:\u003c/span\u003e\u003c/p\u003e\u003cul\u003e\u003cli\u003e\u003cp\u003e\u003cspan style=\"background-color: transparent;\"\u003e4.35.0F and later releases\u003c/span\u003e\u003c/p\u003e\u003c/li\u003e\u003c/ul\u003e\u003c/b\u003e\u003cbr\u003e"
}
],
"value": "The recommended resolution is to upgrade to a remediated software version at your earliest convenience. Arista recommends customers move to the latest version of each release that contains all the fixes listed below. For more information about upgrading see EOS User Manual: Upgrades and Downgrades https://www.arista.com/en/um-eos/eos-upgrades-and-downgrades \n\n\nCVE-2025-8870 has been fixed in the following releases:\n\n * 4.35.0F and later releases"
}
],
"source": {
"defect": [
"1206724"
],
"discovery": "INTERNAL"
},
"title": "On affected platforms running Arista EOS, certain serial console input might result in an unexpected reload of the device.",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cb\u003e\u003cspan style=\"background-color: transparent;\"\u003eThe mitigation is to limit access to the serial console.\u003c/span\u003e\u003c/b\u003e\u003cbr\u003e"
}
],
"value": "The mitigation is to limit access to the serial console."
}
],
"x_generator": {
"engine": "Vulnogram 0.5.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "c8b34d1a-69ae-45c3-88fe-f3b3d44f39b7",
"assignerShortName": "Arista",
"cveId": "CVE-2025-8870",
"datePublished": "2025-11-14T15:57:04.673Z",
"dateReserved": "2025-08-11T18:15:44.614Z",
"dateUpdated": "2025-11-14T16:29:13.516Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2025-8870",
"date": "2026-11-15",
"epss": "0.00178",
"percentile": "0.07394"
},
"nvd": {
"cve": {
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"platforms": [
"710X Series"
],
"product": "EOS",
"vendor": "Arista Networks",
"versions": [
{
"status": "affected",
"version": "4.34.2FX",
"versionType": "custom"
}
]
}
],
"source": "psirt@arista.com"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "On affected platforms running Arista EOS, certain serial console input might result in an unexpected reload of the device.153"
},
{
"lang": "es",
"value": "En plataformas afectadas ejecutando Arista EOS, cierta entrada de consola serie podr\u00eda resultar en una recarga inesperada del dispositivo."
}
],
"id": "CVE-2025-8870",
"lastModified": "2026-10-07T21:10:00.200",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "HIGH",
"attackVector": "PHYSICAL",
"availabilityImpact": "HIGH",
"baseScore": 4.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:P/AC:H/PR:N/UI:N/S:C/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 0.5,
"impactScore": 4.0,
"source": "psirt@arista.com",
"type": "Secondary"
}
],
"cvssMetricV40": [
{
"cvssData": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"attackVector": "PHYSICAL",
"availabilityRequirement": "NOT_DEFINED",
"baseScore": 5.6,
"baseSeverity": "MEDIUM",
"confidentialityRequirement": "NOT_DEFINED",
"exploitMaturity": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:P/AC:L/AT:P/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"source": "psirt@arista.com",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-8870",
"options": [
{
"exploitation": "poc"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-11-14T16:28:58.202689Z",
"version": "2.0.3"
}
}
]
},
"published": "2025-11-14T16:15:59.373",
"references": [
{
"source": "psirt@arista.com",
"url": "https://www.arista.com/en/support/advisories-notices/security-advisory/22811-security-advisory-0125"
}
],
"sourceIdentifier": "psirt@arista.com",
"vulnStatus": "Deferred",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-248"
}
],
"source": "psirt@arista.com",
"type": "Secondary"
}
]
}
},
"redhat_vex": {
"current_release_date": "2025-11-15T16:28:35+00:00",
"cve": "CVE-2025-8870",
"id": "CVE-2025-8870",
"initial_release_date": "2025-11-11T14:00:00+00:00",
"product_status:known_not_affected": "1",
"source": "Red Hat CSAF VEX",
"status": "final",
"title": "On affected platforms running Arista EOS, certain serial console input might result in an unexpected reload of the device.",
"url": "https://security.access.redhat.com/data/csaf/v2/vex/2025/cve-2025-8870.json",
"version": "3"
},
"vulnrichment": {
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-8870",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-11-14T16:28:58.202689Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-11-14T16:29:06.454Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"710X Series"
],
"product": "EOS",
"vendor": "Arista Networks",
"versions": [
{
"status": "affected",
"version": "4.34.2FX",
"versionType": "custom"
}
]
}
],
"configurations": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cb\u003e\u003cp\u003e\u003cspan style=\"background-color: transparent;\"\u003eIn order to be vulnerable to CVE-2025-8870, both of the following conditions must be met:\u003c/span\u003e\u003c/p\u003e\u003cbr\u003e\u003col\u003e\u003cli\u003e\u003cp\u003e\u003cspan style=\"background-color: transparent;\"\u003eAn attacker must have a serial interface connection to the device or access to remotely access the console via the console port. Network remote access does not cause this issue.\u003c/span\u003e\u003c/p\u003e\u003c/li\u003e\u003c/ol\u003e\u003cp\u003e\u003cspan style=\"background-color: transparent;\"\u003eAND\u003c/span\u003e\u003c/p\u003e\u003col\u003e\u003cli\u003e\u003cp\u003e\u003cspan style=\"background-color: transparent;\"\u003eDevice must be using the Synopsys Designware serial model:\u003c/span\u003e\u003c/p\u003e\u003c/li\u003e\u003c/ol\u003e\u003cbr\u003e\u003cdiv\u003e\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003e\u003cspan style=\"background-color: transparent;\"\u003e#bash dmesg | grep \"Synopsys DesignWare\"\u003c/span\u003e\u003c/p\u003e\u003cp\u003e\u003cspan style=\"background-color: transparent;\"\u003e[ \u0026nbsp; 1.287358] 10200000.serial: ttyS0 at MMIO 0x10200000 (irq = 15, base_baud = 15625000) is a \u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 0);\"\u003eSynopsys DesignWare\u003c/span\u003e\u003c/p\u003e\u003cp\u003e\u003cspan style=\"background-color: transparent;\"\u003e[ \u0026nbsp; 1.287845] 10201000.serial: ttyS1 at MMIO 0x10201000 (irq = 164, base_baud = 15625000) is a Synopsys DesignWare\u003c/span\u003e\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003c/tbody\u003e\u003c/table\u003e\u003c/div\u003e\u003c/b\u003e\u003cbr\u003e"
}
],
"value": "In order to be vulnerable to CVE-2025-8870, both of the following conditions must be met:\n\n\n * An attacker must have a serial interface connection to the device or access to remotely access the console via the console port. Network remote access does not cause this issue.\n\n\nAND\n\n * Device must be using the Synopsys Designware serial model:\n\n\n\n#bash dmesg | grep \"Synopsys DesignWare\"\n\n[ \u00a0 1.287358] 10200000.serial: ttyS0 at MMIO 0x10200000 (irq = 15, base_baud = 15625000) is a Synopsys DesignWare\n\n[ \u00a0 1.287845] 10201000.serial: ttyS1 at MMIO 0x10201000 (irq = 164, base_baud = 15625000) is a Synopsys DesignWare"
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:arista_networks:eos:4.34.2fx:*:710x_series:*:*:*:*:*",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
}
],
"datePublic": "2025-11-11T14:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cb\u003e\u003cspan style=\"background-color: transparent;\"\u003eOn affected platforms running Arista EOS, certain serial console input might result in an unexpected reload of the device.153\u003c/span\u003e\u003c/b\u003e\u003cbr\u003e"
}
],
"value": "On affected platforms running Arista EOS, certain serial console input might result in an unexpected reload of the device.153"
}
],
"impacts": [
{
"capecId": "CAPEC-153",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-153 Input Data Manipulation"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "PHYSICAL",
"availabilityImpact": "HIGH",
"baseScore": 4.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:P/AC:H/PR:N/UI:N/S:C/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"attackVector": "PHYSICAL",
"baseScore": 5.6,
"baseSeverity": "MEDIUM",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:P/AC:L/AT:P/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-248",
"description": "CWE-248",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-11-14T15:57:04.673Z",
"orgId": "c8b34d1a-69ae-45c3-88fe-f3b3d44f39b7",
"shortName": "Arista"
},
"references": [
{
"url": "https://www.arista.com/en/support/advisories-notices/security-advisory/22811-security-advisory-0125"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cb\u003e\u003cp\u003e\u003cspan style=\"background-color: transparent;\"\u003eThe recommended resolution is to upgrade to a remediated software version at your earliest convenience. Arista recommends customers move to the latest version of each release that contains all the fixes listed below. For more information about upgrading see \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.arista.com/en/um-eos/eos-upgrades-and-downgrades\"\u003e\u003cspan style=\"background-color: transparent;\"\u003eEOS User Manual: Upgrades and Downgrades\u003c/span\u003e\u003c/a\u003e\u003c/p\u003e\u003cbr\u003e\u003cp\u003e\u003cspan style=\"background-color: transparent;\"\u003eCVE-2025-8870 has been fixed in the following releases:\u003c/span\u003e\u003c/p\u003e\u003cul\u003e\u003cli\u003e\u003cp\u003e\u003cspan style=\"background-color: transparent;\"\u003e4.35.0F and later releases\u003c/span\u003e\u003c/p\u003e\u003c/li\u003e\u003c/ul\u003e\u003c/b\u003e\u003cbr\u003e"
}
],
"value": "The recommended resolution is to upgrade to a remediated software version at your earliest convenience. Arista recommends customers move to the latest version of each release that contains all the fixes listed below. For more information about upgrading see EOS User Manual: Upgrades and Downgrades https://www.arista.com/en/um-eos/eos-upgrades-and-downgrades \n\n\nCVE-2025-8870 has been fixed in the following releases:\n\n * 4.35.0F and later releases"
}
],
"source": {
"defect": [
"1206724"
],
"discovery": "INTERNAL"
},
"title": "On affected platforms running Arista EOS, certain serial console input might result in an unexpected reload of the device.",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cb\u003e\u003cspan style=\"background-color: transparent;\"\u003eThe mitigation is to limit access to the serial console.\u003c/span\u003e\u003c/b\u003e\u003cbr\u003e"
}
],
"value": "The mitigation is to limit access to the serial console."
}
],
"x_generator": {
"engine": "Vulnogram 0.5.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "c8b34d1a-69ae-45c3-88fe-f3b3d44f39b7",
"assignerShortName": "Arista",
"cveId": "CVE-2025-8870",
"datePublished": "2025-11-14T15:57:04.673Z",
"dateReserved": "2025-08-11T18:15:44.614Z",
"dateUpdated": "2025-11-14T16:29:13.516Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
}
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.