CVE-2025-7357 (GCVE-0-2025-7357)
Vulnerability from cvelistv5 – Published: 2025-07-16 15:56 – Updated: 2025-07-18 14:38
VLAI
EPSS
VEX
Title
Plaintext Storage of a Password in LITEON IC48A and IC80A EV Chargers
Summary
LITEON IC48A firmware versions prior to 01.00.19r and LITEON IC80A firmware versions prior to 01.01.12e store FTP-server-access-credentials in cleartext in their system logs.
Severity
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-07-18 14:38 UTC
CWE
- CWE-256 - Plaintext Storage of a Password
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.cisa.gov/news-events/ics-advisories/i… | government-resource |
Impacted products
2 products
| Vendor | Product | Version | CPE status | |
|---|---|---|---|---|
| LITEON | IC48A EV Charger |
Affected:
0 , < 01.00.19r
(custom)
|
guessed | |
| LITEON | IC80A EV Charger |
Affected:
0 , < 01.01.12e
(custom)
|
guessed |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-7357",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-18T14:38:46.980127Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-18T14:38:53.584Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "IC48A EV Charger",
"vendor": "LITEON",
"versions": [
{
"lessThan": "01.00.19r",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "IC80A EV Charger",
"vendor": "LITEON",
"versions": [
{
"lessThan": "01.01.12e",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Murat Sagdullaev of Electrada"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eLITEON IC48A firmware versions prior to 01.00.19r and LITEON IC80A firmware versions prior to 01.01.12e store FTP-server-access-credentials in cleartext in their system logs.\u003c/p\u003e\u003cbr\u003e"
}
],
"value": "LITEON IC48A firmware versions prior to 01.00.19r and LITEON IC80A firmware versions prior to 01.01.12e store FTP-server-access-credentials in cleartext in their system logs."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-256",
"description": "CWE-256 Plaintext Storage of a Password",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-16T15:56:33.623Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-196-03"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eLITEON has released the following firmware versions for the following EV chargers:\u003c/p\u003e\u003cul\u003e\u003cli\u003eLITEON IC48A: Firmware versions 01.00.20h\u003c/li\u003e\u003cli\u003eLITEON IC80A: Firmware versions 01.01.13m\u003c/li\u003e\u003c/ul\u003e\u003cp\u003eFor more information, contact \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.liteon.com/en/contact/contact-us\"\u003eLITEON\u003c/a\u003e.\u003c/p\u003e\n\n\u003cbr\u003e"
}
],
"value": "LITEON has released the following firmware versions for the following EV chargers:\n\n * LITEON IC48A: Firmware versions 01.00.20h\n * LITEON IC80A: Firmware versions 01.01.13m\n\n\nFor more information, contact LITEON https://www.liteon.com/en/contact/contact-us ."
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Plaintext Storage of a Password in LITEON IC48A and IC80A EV Chargers",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2025-7357",
"datePublished": "2025-07-16T15:56:33.623Z",
"dateReserved": "2025-07-08T14:32:29.576Z",
"dateUpdated": "2025-07-18T14:38:53.584Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2025-7357",
"date": "2026-10-18",
"epss": "0.00423",
"percentile": "0.35121"
},
"nvd": {
"cve": {
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "IC48A EV Charger",
"vendor": "LITEON",
"versions": [
{
"lessThan": "01.00.19r",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "IC80A EV Charger",
"vendor": "LITEON",
"versions": [
{
"lessThan": "01.01.12e",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"source": "ics-cert@hq.dhs.gov"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "LITEON IC48A firmware versions prior to 01.00.19r and LITEON IC80A firmware versions prior to 01.01.12e store FTP-server-access-credentials in cleartext in their system logs."
},
{
"lang": "es",
"value": "Las versiones de firmware de LITEON IC48A anteriores a 01.00.19r y las versiones de firmware de LITEON IC80A anteriores a 01.01.12e almacenan las credenciales de acceso al servidor FTP en texto sin formato en sus registros del sistema."
}
],
"id": "CVE-2025-7357",
"lastModified": "2026-06-17T10:04:46.660",
"metrics": {
"cvssMetricV40": [
{
"cvssData": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"availabilityRequirement": "NOT_DEFINED",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"exploitMaturity": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"source": "ics-cert@hq.dhs.gov",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-7357",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-18T14:38:46.980127Z",
"version": "2.0.3"
}
}
]
},
"published": "2025-07-16T16:15:29.627",
"references": [
{
"source": "ics-cert@hq.dhs.gov",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-196-03"
}
],
"sourceIdentifier": "ics-cert@hq.dhs.gov",
"vulnStatus": "Deferred",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-256"
}
],
"source": "ics-cert@hq.dhs.gov",
"type": "Secondary"
}
]
}
},
"redhat_vex": {
"current_release_date": "2025-07-18T17:58:15+00:00",
"cve": "CVE-2025-7357",
"id": "CVE-2025-7357",
"initial_release_date": "2025-01-01T00:00:00+00:00",
"product_status:known_not_affected": "1",
"source": "Red Hat CSAF VEX",
"status": "final",
"title": "Plaintext Storage of a Password in LITEON IC48A and IC80A EV Chargers",
"url": "https://security.access.redhat.com/data/csaf/v2/vex/2025/cve-2025-7357.json",
"version": "3"
},
"vulnrichment": {
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-7357",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-18T14:38:46.980127Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-18T14:38:50.433Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "IC48A EV Charger",
"vendor": "LITEON",
"versions": [
{
"lessThan": "01.00.19r",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "IC80A EV Charger",
"vendor": "LITEON",
"versions": [
{
"lessThan": "01.01.12e",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Murat Sagdullaev of Electrada"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eLITEON IC48A firmware versions prior to 01.00.19r and LITEON IC80A firmware versions prior to 01.01.12e store FTP-server-access-credentials in cleartext in their system logs.\u003c/p\u003e\u003cbr\u003e"
}
],
"value": "LITEON IC48A firmware versions prior to 01.00.19r and LITEON IC80A firmware versions prior to 01.01.12e store FTP-server-access-credentials in cleartext in their system logs."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-256",
"description": "CWE-256 Plaintext Storage of a Password",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-16T15:56:33.623Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-196-03"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eLITEON has released the following firmware versions for the following EV chargers:\u003c/p\u003e\u003cul\u003e\u003cli\u003eLITEON IC48A: Firmware versions 01.00.20h\u003c/li\u003e\u003cli\u003eLITEON IC80A: Firmware versions 01.01.13m\u003c/li\u003e\u003c/ul\u003e\u003cp\u003eFor more information, contact \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.liteon.com/en/contact/contact-us\"\u003eLITEON\u003c/a\u003e.\u003c/p\u003e\n\n\u003cbr\u003e"
}
],
"value": "LITEON has released the following firmware versions for the following EV chargers:\n\n * LITEON IC48A: Firmware versions 01.00.20h\n * LITEON IC80A: Firmware versions 01.01.13m\n\n\nFor more information, contact LITEON https://www.liteon.com/en/contact/contact-us ."
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Plaintext Storage of a Password in LITEON IC48A and IC80A EV Chargers",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2025-7357",
"datePublished": "2025-07-16T15:56:33.623Z",
"dateReserved": "2025-07-08T14:32:29.576Z",
"dateUpdated": "2025-07-18T14:38:53.584Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
Loading timeline…
Loading…
Loading…
The MITRE ATT&CK techniques below are AI-generated suggestions, inferred from the description of the
vulnerability by the CIRCL/vulnerability-attack-technique-classification-roberta-base
model, served locally by ML-Gateway.
They have not been verified by an analyst and are provided for guidance only.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Loading…
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.