CVE-2025-64090 (GCVE-0-2025-64090)
Vulnerability from cvelistv5 – Published: 2026-01-09 09:59 – Updated: 2026-01-09 18:01
VLAI
EPSS
VEX
Title
Authenticated Remote Code Execution in device hostname
Summary
This vulnerability allows authenticated attackers to execute commands via the hostname of the device.
Severity
10 (Critical)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.zenitel.com/sites/default/files/2025-… | vendor-advisory |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-64090",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-01-09T18:00:44.701618Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-01-09T18:01:00.742Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "TCIS-3+",
"vendor": "Zenitel",
"versions": [
{
"status": "affected",
"version": "\u003c9.2.3.3",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "This vulnerability allows authenticated attackers to execute commands via the hostname of the device."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"availabilityRequirement": "NOT_DEFINED",
"baseScore": 10,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"environmentalScore": 10,
"environmentalSeverity": "CRITICAL",
"exploitCodeMaturity": "NOT_DEFINED",
"integrityImpact": "HIGH",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackComplexity": "LOW",
"modifiedAttackVector": "NETWORK",
"modifiedAvailabilityImpact": "HIGH",
"modifiedConfidentialityImpact": "HIGH",
"modifiedIntegrityImpact": "HIGH",
"modifiedPrivilegesRequired": "NONE",
"modifiedScope": "CHANGED",
"modifiedUserInteraction": "NONE",
"privilegesRequired": "NONE",
"remediationLevel": "NOT_DEFINED",
"reportConfidence": "NOT_DEFINED",
"scope": "CHANGED",
"temporalScore": 10,
"temporalSeverity": "CRITICAL",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-01-09T09:59:58.839Z",
"orgId": "cf4a7ff5-dd38-4ede-a530-ffaa7ea59c39",
"shortName": "NCSC-NL"
},
"references": [
{
"name": "Zenitel Security Advisory",
"tags": [
"vendor-advisory"
],
"url": "https://www.zenitel.com/sites/default/files/2025-12/A100K12333%20Zenitel%20Security%20Advisory.pdf"
}
],
"title": "Authenticated Remote Code Execution in device hostname",
"x_generator": {
"engine": "cvelib 1.8.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "cf4a7ff5-dd38-4ede-a530-ffaa7ea59c39",
"assignerShortName": "NCSC-NL",
"cveId": "CVE-2025-64090",
"datePublished": "2026-01-09T09:59:58.839Z",
"dateReserved": "2025-10-27T09:43:10.200Z",
"dateUpdated": "2026-01-09T18:01:00.742Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2025-64090",
"date": "2026-07-11",
"epss": "0.00361",
"percentile": "0.28288"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2025-64090\",\"sourceIdentifier\":\"cert@ncsc.nl\",\"published\":\"2026-01-09T10:15:46.480\",\"lastModified\":\"2026-06-17T09:53:48.250\",\"vulnStatus\":\"Analyzed\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"This vulnerability allows authenticated attackers to execute commands via the hostname of the device.\"},{\"lang\":\"es\",\"value\":\"Esta vulnerabilidad permite a atacantes autenticados ejecutar comandos a trav\u00e9s del nombre de host del dispositivo.\"}],\"affected\":[{\"source\":\"cert@ncsc.nl\",\"affectedData\":[{\"vendor\":\"Zenitel\",\"product\":\"TCIS-3+\",\"defaultStatus\":\"unaffected\",\"versions\":[{\"version\":\"\u003c9.2.3.3\",\"versionType\":\"custom\",\"status\":\"affected\"}]}]}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"cert@ncsc.nl\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H\",\"baseScore\":10.0,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":6.0},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.9}],\"ssvcV203\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"ssvcData\":{\"timestamp\":\"2026-01-09T18:00:44.701618Z\",\"id\":\"CVE-2025-64090\",\"options\":[{\"exploitation\":\"none\"},{\"automatable\":\"yes\"},{\"technicalImpact\":\"total\"}],\"role\":\"CISA Coordinator\",\"version\":\"2.0.3\"}}]},\"weaknesses\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-77\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:zenitel:tcis-3_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"9.2.3.3\",\"matchCriteriaId\":\"1B689976-D6D7-4D27-907B-9866767A4045\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:zenitel:tcis-3:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E46C75FA-422D-4C09-80E3-D946D65F078E\"}]}]}],\"references\":[{\"url\":\"https://www.zenitel.com/sites/default/files/2025-12/A100K12333%20Zenitel%20Security%20Advisory.pdf\",\"source\":\"cert@ncsc.nl\",\"tags\":[\"Vendor Advisory\"]}]}}",
"redhat_vex": {
"current_release_date": "2026-01-13T22:52:22+00:00",
"cve": "CVE-2025-64090",
"id": "CVE-2025-64090",
"initial_release_date": "2025-01-01T00:00:00+00:00",
"product_status:known_not_affected": "1",
"source": "Red Hat CSAF VEX",
"status": "final",
"title": "Authenticated Remote Code Execution in device hostname",
"url": "https://security.access.redhat.com/data/csaf/v2/vex/2025/cve-2025-64090.json",
"version": "3"
},
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-64090\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2026-01-09T18:00:44.701618Z\"}}}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-77\", \"description\": \"CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)\"}]}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2026-01-09T18:00:38.167Z\"}}], \"cna\": {\"title\": \"Authenticated Remote Code Execution in device hostname\", \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"CHANGED\", \"version\": \"3.1\", \"baseScore\": 10, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"CRITICAL\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H\", \"modifiedScope\": \"CHANGED\", \"temporalScore\": 10, \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"remediationLevel\": \"NOT_DEFINED\", \"reportConfidence\": \"NOT_DEFINED\", \"temporalSeverity\": \"CRITICAL\", \"availabilityImpact\": \"HIGH\", \"environmentalScore\": 10, \"privilegesRequired\": \"NONE\", \"exploitCodeMaturity\": \"NOT_DEFINED\", \"integrityRequirement\": \"NOT_DEFINED\", \"modifiedAttackVector\": \"NETWORK\", \"confidentialityImpact\": \"HIGH\", \"environmentalSeverity\": \"CRITICAL\", \"availabilityRequirement\": \"NOT_DEFINED\", \"modifiedIntegrityImpact\": \"HIGH\", \"modifiedUserInteraction\": \"NONE\", \"modifiedAttackComplexity\": \"LOW\", \"confidentialityRequirement\": \"NOT_DEFINED\", \"modifiedAvailabilityImpact\": \"HIGH\", \"modifiedPrivilegesRequired\": \"NONE\", \"modifiedConfidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Zenitel\", \"product\": \"TCIS-3+\", \"versions\": [{\"status\": \"affected\", \"version\": \"\u003c9.2.3.3\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unaffected\"}], \"references\": [{\"url\": \"https://www.zenitel.com/sites/default/files/2025-12/A100K12333%20Zenitel%20Security%20Advisory.pdf\", \"name\": \"Zenitel Security Advisory\", \"tags\": [\"vendor-advisory\"]}], \"x_generator\": {\"engine\": \"cvelib 1.8.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"This vulnerability allows authenticated attackers to execute commands via the hostname of the device.\"}], \"providerMetadata\": {\"orgId\": \"cf4a7ff5-dd38-4ede-a530-ffaa7ea59c39\", \"shortName\": \"NCSC-NL\", \"dateUpdated\": \"2026-01-09T09:59:58.839Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2025-64090\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2026-01-09T18:01:00.742Z\", \"dateReserved\": \"2025-10-27T09:43:10.200Z\", \"assignerOrgId\": \"cf4a7ff5-dd38-4ede-a530-ffaa7ea59c39\", \"datePublished\": \"2026-01-09T09:59:58.839Z\", \"assignerShortName\": \"NCSC-NL\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
}
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…