CVE-2025-54849 (GCVE-0-2025-54849)
Vulnerability from cvelistv5 – Published: 2025-12-01 15:25 – Updated: 2025-12-01 20:16- CWE-306 - Missing Authentication for Critical Function
| Vendor | Product | Version | CPE status | |
|---|---|---|---|---|
| Socomec | DIRIS Digiware M-70 |
Affected:
1.6.9
|
guessed |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-54849",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-12-01T20:16:17.676904Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-12-01T20:16:27.906Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "DIRIS Digiware M-70",
"vendor": "Socomec",
"versions": [
{
"status": "affected",
"version": "1.6.9"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Discovered by Kelly Patterson of Cisco Talos."
}
],
"descriptions": [
{
"lang": "en",
"value": "A denial of service vulnerability exists in the Modbus TCP and Modbus RTU over TCP functionality of Socomec DIRIS Digiware M-70 1.6.9. A specially crafted series of network requests can lead to a denial of service. An attacker can send a sequence of unauthenticated packets to trigger this vulnerability.An attacker can trigger this denial-of-service condition by sending a single Modbus TCP message to port 502 using the Write Single Register function code (6) to write the value 1 to register 4352. This action changes the Modbus address to 15. After this message is sent, the device will be in a denial-of-service state."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306: Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-12-01T15:25:13.025Z",
"orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"shortName": "talos"
},
"references": [
{
"name": "https://talosintelligence.com/vulnerability_reports/TALOS-2025-2248",
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2025-2248"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"assignerShortName": "talos",
"cveId": "CVE-2025-54849",
"datePublished": "2025-12-01T15:25:13.025Z",
"dateReserved": "2025-07-31T15:17:58.545Z",
"dateUpdated": "2025-12-01T20:16:27.906Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2025-54849",
"date": "2026-11-18",
"epss": "0.00344",
"percentile": "0.28479"
},
"nvd": {
"cve": {
"affected": [
{
"affectedData": [
{
"product": "DIRIS Digiware M-70",
"vendor": "Socomec",
"versions": [
{
"status": "affected",
"version": "1.6.9"
}
]
}
],
"source": "talos-cna@cisco.com"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:socomec:diris_digiware_m-70_firmware:1.6.9:*:*:*:*:*:*:*",
"matchCriteriaId": "741E83B6-F217-46E7-9E3A-8E446250C785",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:socomec:diris_digiware_m-70:-:*:*:*:*:*:*:*",
"matchCriteriaId": "76CAA8C6-29FD-40F3-9702-790CD73F3052",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A denial of service vulnerability exists in the Modbus TCP and Modbus RTU over TCP functionality of Socomec DIRIS Digiware M-70 1.6.9. A specially crafted series of network requests can lead to a denial of service. An attacker can send a sequence of unauthenticated packets to trigger this vulnerability.An attacker can trigger this denial-of-service condition by sending a single Modbus TCP message to port 502 using the Write Single Register function code (6) to write the value 1 to register 4352. This action changes the Modbus address to 15. After this message is sent, the device will be in a denial-of-service state."
},
{
"lang": "es",
"value": "Una vulnerabilidad de denegaci\u00f3n de servicio existe en la funcionalidad Modbus TCP y Modbus RTU sobre TCP de Socomec DIRIS Digiware M-70 1.6.9. Una serie de solicitudes de red especialmente dise\u00f1adas puede conducir a una denegaci\u00f3n de servicio. Un atacante puede enviar una secuencia de paquetes no autenticados para activar esta vulnerabilidad. Un atacante puede activar esta condici\u00f3n de denegaci\u00f3n de servicio enviando un \u00fanico mensaje Modbus TCP al puerto 502 utilizando el c\u00f3digo de funci\u00f3n Write Single Register (6) para escribir el valor 1 en el registro 4352. Esta acci\u00f3n cambia la direcci\u00f3n Modbus a 15. Despu\u00e9s de que se env\u00eda este mensaje, el dispositivo estar\u00e1 en un estado de denegaci\u00f3n de servicio."
}
],
"id": "CVE-2025-54849",
"lastModified": "2026-09-26T00:10:00.127",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "talos-cna@cisco.com",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-54849",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-12-01T20:16:17.676904Z",
"version": "2.0.3"
}
}
]
},
"published": "2025-12-01T16:15:53.900",
"references": [
{
"source": "talos-cna@cisco.com",
"tags": [
"Vendor Advisory"
],
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2025-2248"
}
],
"sourceIdentifier": "talos-cna@cisco.com",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-306"
}
],
"source": "talos-cna@cisco.com",
"type": "Secondary"
}
]
}
},
"redhat_vex": {
"current_release_date": "2025-12-02T16:14:48+00:00",
"cve": "CVE-2025-54849",
"id": "CVE-2025-54849",
"initial_release_date": "2025-01-01T00:00:00+00:00",
"product_status:known_not_affected": "1",
"source": "Red Hat CSAF VEX",
"status": "final",
"title": "CVE-2025-54849",
"url": "https://security.access.redhat.com/data/csaf/v2/vex/2025/cve-2025-54849.json",
"version": "3"
},
"vulnrichment": {
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-54849",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-12-01T20:16:17.676904Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-12-01T20:16:23.762Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "DIRIS Digiware M-70",
"vendor": "Socomec",
"versions": [
{
"status": "affected",
"version": "1.6.9"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Discovered by Kelly Patterson of Cisco Talos."
}
],
"descriptions": [
{
"lang": "en",
"value": "A denial of service vulnerability exists in the Modbus TCP and Modbus RTU over TCP functionality of Socomec DIRIS Digiware M-70 1.6.9. A specially crafted series of network requests can lead to a denial of service. An attacker can send a sequence of unauthenticated packets to trigger this vulnerability.An attacker can trigger this denial-of-service condition by sending a single Modbus TCP message to port 502 using the Write Single Register function code (6) to write the value 1 to register 4352. This action changes the Modbus address to 15. After this message is sent, the device will be in a denial-of-service state."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306: Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-12-01T15:25:13.025Z",
"orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"shortName": "talos"
},
"references": [
{
"name": "https://talosintelligence.com/vulnerability_reports/TALOS-2025-2248",
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2025-2248"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"assignerShortName": "talos",
"cveId": "CVE-2025-54849",
"datePublished": "2025-12-01T15:25:13.025Z",
"dateReserved": "2025-07-31T15:17:58.545Z",
"dateUpdated": "2025-12-01T20:16:27.906Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
}
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour