CVE-2025-4384 (GCVE-0-2025-4384)
Vulnerability from cvelistv5 – Published: 2025-05-06 15:59 – Updated: 2025-09-05 16:38- CWE-298 - Improper Validation of Certificate Expiration
| URL | Tags |
|---|---|
| https://www.pcvue.com/security/#SB2025-3 | vendor-advisory |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-4384",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-06T19:28:43.088933Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-05-06T19:28:57.621Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"modules": [
"MQTT add-on"
],
"product": "PcVue",
"vendor": "arcinfo",
"versions": [
{
"status": "unaffected",
"version": "16.3.0",
"versionType": "cpe"
},
{
"lessThan": "16.2.5",
"status": "affected",
"version": "16.0",
"versionType": "cpe"
},
{
"lessThan": "15.2.12",
"status": "affected",
"version": "15.0",
"versionType": "cpe"
}
]
}
],
"datePublic": "2025-05-05T22:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The MQTT add-on of PcVue fails to verify that a remote device\u2019s certificate has not already expired or has not yet become valid. This allows malicious devices to present certificates that are not rejected properly.\u003cbr\u003e\u003cbr\u003eThe use of a client certificate reduces the risk for random devices to take advantage of this flaw.\u003cbr\u003e\u003cbr\u003e"
}
],
"value": "The MQTT add-on of PcVue fails to verify that a remote device\u2019s certificate has not already expired or has not yet become valid. This allows malicious devices to present certificates that are not rejected properly.\n\nThe use of a client certificate reduces the risk for random devices to take advantage of this flaw."
}
],
"exploits": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "No POC available."
}
],
"value": "No POC available."
},
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Not known to be exploited."
}
],
"value": "Not known to be exploited."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NO",
"Recovery": "USER",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"attackVector": "ADJACENT",
"baseScore": 6,
"baseSeverity": "MEDIUM",
"privilegesRequired": "NONE",
"providerUrgency": "GREEN",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N/AU:N/R:U/RE:M/U:Green",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "MODERATE"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-298",
"description": "CWE-298 Improper Validation of Certificate Expiration",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-09-05T16:38:07.518Z",
"orgId": "87c8e6ad-f0f5-4ca8-89e2-89f26d6ed932",
"shortName": "arcinfo"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.pcvue.com/security/#SB2025-3"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cb\u003e\u003cu\u003eHarden the configuration\u003c/u\u003e\u003c/b\u003e\u003cbr\u003eWho should apply this recommendation: All users\u003cbr\u003eThe system operators are highly recommended to take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:\u003cbr\u003e\u003cul\u003e\u003cli\u003eUse client certificate when configuring the MQTT add-on.\u003c/li\u003e\u003cli\u003eMinimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the Internet unless required.\u003c/li\u003e\u003cli\u003eLocate control system networks and remote devices behind firewalls and isolate them from business networks.\u003c/li\u003e\u003cli\u003eWhen remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as its connected devices.\u003c/li\u003e\u003c/ul\u003e\u003cbr\u003e\u003cb\u003e\u003cu\u003eUpdate PcVue\u003c/u\u003e\u003c/b\u003e\u003cbr\u003eWho should apply this recommendation: All users using the affected component\u003cbr\u003eApply the patch by installing a fixed PcVue version.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cu\u003e\u003cb\u003eAvailable patches:\u003c/b\u003e\u003c/u\u003e\u003cbr\u003eFixed in:\u003cbr\u003e\u003cul\u003e\u003cli\u003ePcVue 16.2.5 and PcVue 16.3.0\u003c/li\u003e\u003cli\u003ePcVue 15.2.12\u003c/li\u003e\u003c/ul\u003e\u003cbr\u003e"
}
],
"value": "Harden the configuration\nWho should apply this recommendation: All users\nThe system operators are highly recommended to take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:\n * Use client certificate when configuring the MQTT add-on.\n * Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the Internet unless required.\n * Locate control system networks and remote devices behind firewalls and isolate them from business networks.\n * When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as its connected devices.\n\n\n\nUpdate PcVue\nWho should apply this recommendation: All users using the affected component\nApply the patch by installing a fixed PcVue version.\n\n\nAvailable patches:\nFixed in:\n * PcVue 16.2.5 and PcVue 16.3.0\n * PcVue 15.2.12"
}
],
"source": {
"advisory": "SB2025-3",
"discovery": "INTERNAL"
},
"title": "Certificate validity not properly verified",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "87c8e6ad-f0f5-4ca8-89e2-89f26d6ed932",
"assignerShortName": "arcinfo",
"cveId": "CVE-2025-4384",
"datePublished": "2025-05-06T15:59:27.839Z",
"dateReserved": "2025-05-06T15:02:58.174Z",
"dateUpdated": "2025-09-05T16:38:07.518Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2025-4384",
"date": "2026-11-16",
"epss": "0.00133",
"percentile": "0.02871"
},
"nvd": {
"cve": {
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"modules": [
"MQTT add-on"
],
"product": "PcVue",
"vendor": "arcinfo",
"versions": [
{
"status": "unaffected",
"version": "16.3.0",
"versionType": "cpe"
},
{
"lessThan": "16.2.5",
"status": "affected",
"version": "16.0",
"versionType": "cpe"
},
{
"lessThan": "15.2.12",
"status": "affected",
"version": "15.0",
"versionType": "cpe"
}
]
}
],
"source": "87c8e6ad-f0f5-4ca8-89e2-89f26d6ed932"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "The MQTT add-on of PcVue fails to verify that a remote device\u2019s certificate has not already expired or has not yet become valid. This allows malicious devices to present certificates that are not rejected properly.\n\nThe use of a client certificate reduces the risk for random devices to take advantage of this flaw."
},
{
"lang": "es",
"value": "El complemento MQTT de PcVue no verifica que el certificado de un dispositivo remoto no haya caducado o no sea v\u00e1lido. Esto permite que dispositivos maliciosos presenten certificados que no se rechazan correctamente. El uso de un certificado de cliente reduce el riesgo de que dispositivos aleatorios se aprovechen de esta vulnerabilidad."
}
],
"id": "CVE-2025-4384",
"lastModified": "2026-06-17T09:33:09.820",
"metrics": {
"cvssMetricV40": [
{
"cvssData": {
"Automatable": "NO",
"Recovery": "USER",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"attackVector": "ADJACENT",
"availabilityRequirement": "NOT_DEFINED",
"baseScore": 6.0,
"baseSeverity": "MEDIUM",
"confidentialityRequirement": "NOT_DEFINED",
"exploitMaturity": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "GREEN",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:N/R:U/V:X/RE:M/U:Green",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "MODERATE"
},
"source": "87c8e6ad-f0f5-4ca8-89e2-89f26d6ed932",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-4384",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-06T19:28:43.088933Z",
"version": "2.0.3"
}
}
]
},
"published": "2025-05-06T16:15:32.340",
"references": [
{
"source": "87c8e6ad-f0f5-4ca8-89e2-89f26d6ed932",
"url": "https://www.pcvue.com/security/#SB2025-3"
}
],
"sourceIdentifier": "87c8e6ad-f0f5-4ca8-89e2-89f26d6ed932",
"vulnStatus": "Deferred",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-298"
}
],
"source": "87c8e6ad-f0f5-4ca8-89e2-89f26d6ed932",
"type": "Secondary"
}
]
}
},
"redhat_vex": {
"current_release_date": "2025-05-28T18:13:51+00:00",
"cve": "CVE-2025-4384",
"id": "CVE-2025-4384",
"initial_release_date": "2025-05-05T22:00:00+00:00",
"product_status:known_not_affected": "1",
"source": "Red Hat CSAF VEX",
"status": "final",
"title": "Certificate validity not properly verified",
"url": "https://security.access.redhat.com/data/csaf/v2/vex/2025/cve-2025-4384.json",
"version": "3"
},
"vulnrichment": {
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-4384",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-06T19:28:43.088933Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-05-06T19:25:46.615Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"modules": [
"MQTT add-on"
],
"product": "PcVue",
"vendor": "arcinfo",
"versions": [
{
"status": "unaffected",
"version": "16.3.0",
"versionType": "cpe"
},
{
"lessThan": "16.2.5",
"status": "affected",
"version": "16.0",
"versionType": "cpe"
},
{
"lessThan": "15.2.12",
"status": "affected",
"version": "15.0",
"versionType": "cpe"
}
]
}
],
"datePublic": "2025-05-05T22:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The MQTT add-on of PcVue fails to verify that a remote device\u2019s certificate has not already expired or has not yet become valid. This allows malicious devices to present certificates that are not rejected properly.\u003cbr\u003e\u003cbr\u003eThe use of a client certificate reduces the risk for random devices to take advantage of this flaw.\u003cbr\u003e\u003cbr\u003e"
}
],
"value": "The MQTT add-on of PcVue fails to verify that a remote device\u2019s certificate has not already expired or has not yet become valid. This allows malicious devices to present certificates that are not rejected properly.\n\nThe use of a client certificate reduces the risk for random devices to take advantage of this flaw."
}
],
"exploits": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "No POC available."
}
],
"value": "No POC available."
},
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Not known to be exploited."
}
],
"value": "Not known to be exploited."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NO",
"Recovery": "USER",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"attackVector": "ADJACENT",
"baseScore": 6,
"baseSeverity": "MEDIUM",
"privilegesRequired": "NONE",
"providerUrgency": "GREEN",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N/AU:N/R:U/RE:M/U:Green",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "MODERATE"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-298",
"description": "CWE-298 Improper Validation of Certificate Expiration",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-09-05T16:38:07.518Z",
"orgId": "87c8e6ad-f0f5-4ca8-89e2-89f26d6ed932",
"shortName": "arcinfo"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.pcvue.com/security/#SB2025-3"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cb\u003e\u003cu\u003eHarden the configuration\u003c/u\u003e\u003c/b\u003e\u003cbr\u003eWho should apply this recommendation: All users\u003cbr\u003eThe system operators are highly recommended to take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:\u003cbr\u003e\u003cul\u003e\u003cli\u003eUse client certificate when configuring the MQTT add-on.\u003c/li\u003e\u003cli\u003eMinimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the Internet unless required.\u003c/li\u003e\u003cli\u003eLocate control system networks and remote devices behind firewalls and isolate them from business networks.\u003c/li\u003e\u003cli\u003eWhen remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as its connected devices.\u003c/li\u003e\u003c/ul\u003e\u003cbr\u003e\u003cb\u003e\u003cu\u003eUpdate PcVue\u003c/u\u003e\u003c/b\u003e\u003cbr\u003eWho should apply this recommendation: All users using the affected component\u003cbr\u003eApply the patch by installing a fixed PcVue version.\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cu\u003e\u003cb\u003eAvailable patches:\u003c/b\u003e\u003c/u\u003e\u003cbr\u003eFixed in:\u003cbr\u003e\u003cul\u003e\u003cli\u003ePcVue 16.2.5 and PcVue 16.3.0\u003c/li\u003e\u003cli\u003ePcVue 15.2.12\u003c/li\u003e\u003c/ul\u003e\u003cbr\u003e"
}
],
"value": "Harden the configuration\nWho should apply this recommendation: All users\nThe system operators are highly recommended to take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:\n * Use client certificate when configuring the MQTT add-on.\n * Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the Internet unless required.\n * Locate control system networks and remote devices behind firewalls and isolate them from business networks.\n * When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as its connected devices.\n\n\n\nUpdate PcVue\nWho should apply this recommendation: All users using the affected component\nApply the patch by installing a fixed PcVue version.\n\n\nAvailable patches:\nFixed in:\n * PcVue 16.2.5 and PcVue 16.3.0\n * PcVue 15.2.12"
}
],
"source": {
"advisory": "SB2025-3",
"discovery": "INTERNAL"
},
"title": "Certificate validity not properly verified",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "87c8e6ad-f0f5-4ca8-89e2-89f26d6ed932",
"assignerShortName": "arcinfo",
"cveId": "CVE-2025-4384",
"datePublished": "2025-05-06T15:59:27.839Z",
"dateReserved": "2025-05-06T15:02:58.174Z",
"dateUpdated": "2025-09-05T16:38:07.518Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Solutions
Exploits
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.