CVE-2025-25037 (GCVE-0-2025-25037)
Vulnerability from cvelistv5 – Published: 2025-06-20 18:35 – Updated: 2026-07-28 01:47 X_Known Exploited Vulnerability- CWE-200 - Exposure of Sensitive Information to an Unauthorized Actor
| URL | Tags |
|---|---|
| https://www.zeroscience.mk/en/vulnerabilities/ZSL… | exploitthird-party-advisory |
| https://www.exploit-db.com/exploits/52028 | exploitthird-party-advisory |
| https://fortiguard.fortinet.com/encyclopedia/ips/56008 | third-party-advisory |
| https://www.aquatronica.com | product |
| https://vulncheck.com/advisories/aquatronica-cont… | third-party-advisory |
| Vendor | Product | Version | CPE status | |
|---|---|---|---|---|
| Aquatronica | Aquatronica Controller System |
Affected:
0 , ≤ 5.1.6
(semver)
cpe:2.3:a:aviatrix:controller:*:*:*:*:*:*:*:* |
Shadowserver
Known Exploited Vulnerability - GCVE BCP-07 Compliant
Exploited: Yes
Timestamps
Scope
Evidence
Type: Honeypot
Signal: In The Wild Attempts
Confidence: 70%
Source: shadowserver
Details
| 1D | 1 |
|---|---|
| Iot | no |
| Feed | Shadowserver Foundation honeypot/exploited-vulnerabilities |
| Type | http-scan |
| Class | other-software |
| 7D Avg | 0 |
| Vendor | Aquatronica |
| 30D Avg | 0 |
| 90D Avg | 0 |
| Product | Aquatronica Control System |
| Cisa Kev | no |
| Connections | 3 |
| Observation Date | 2026-11-04 |
| Vulnerability Class | None |
| Vulnerability Score | None |
| Vulnerability Severity | None |
References
Previdian
Known Exploited Vulnerability - GCVE BCP-07 Compliant
Exploited: Yes
Timestamps
Scope
Evidence
Type: Public Report
Signal: Successful Exploitation
Confidence: 70%
Source: kevintel
Details
| Feed | KEVIntel (kevintel.com) |
|---|---|
| Title | Aquatronica Controller System Complete Information Disclosure |
| Vendor | Aquatronica |
| Product | Aquatronica Controller System |
| Added Date | 2026-03-24T00:00:00.000Z |
| Cvss Score | 9.3 |
| Epss Score | None |
| Cvss Severity | CRITICAL |
| Epss Percentile | None |
| Used In Malware | unknown |
| Ahead Of Cisa Kev | None |
| Not Yet In Cisa Kev | True |
References
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-25037",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-06-23T20:32:57.296954Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-23T20:33:15.219Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"modules": [
"Web Management Interface (tcp.php endpoint)"
],
"product": "Aquatronica Controller System",
"vendor": "Aquatronica",
"versions": [
{
"lessThanOrEqual": "5.1.6",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:aviatrix:controller:*:*:*:*:*:*:*:*",
"versionEndIncluding": "5.1.6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Gjoko Krstic"
}
],
"datePublic": "2024-05-31T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An information disclosure vulnerability exists in Aquatronica Controller System firmware versions \u003c= 5.1.6 and web interface versions \u003c= 2.0. The tcp.php endpoint fails to restrict unauthenticated access, allowing remote attackers to issue crafted POST requests and retrieve sensitive configuration data, including plaintext administrative credentials. Exploitation of this flaw can lead to full compromise of the system, enabling unauthorized manipulation of connected devices and aquarium parameters."
}
],
"value": "An information disclosure vulnerability exists in Aquatronica Controller System firmware versions \u003c= 5.1.6 and web interface versions \u003c= 2.0. The tcp.php endpoint fails to restrict unauthenticated access, allowing remote attackers to issue crafted POST requests and retrieve sensitive configuration data, including plaintext administrative credentials. Exploitation of this flaw can lead to full compromise of the system, enabling unauthorized manipulation of connected devices and aquarium parameters."
}
],
"impacts": [
{
"capecId": "CAPEC-1",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-1 Accessing Functionality Not Properly Constrained by ACLs"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "HIGH",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:H/SI:H/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-200",
"description": "CWE-200 Exposure of Sensitive Information to an Unauthorized Actor",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-28T01:47:56.966Z",
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"shortName": "VulnCheck"
},
"references": [
{
"tags": [
"exploit",
"third-party-advisory"
],
"url": "https://www.zeroscience.mk/en/vulnerabilities/ZSL-2024-5824.php"
},
{
"tags": [
"exploit",
"third-party-advisory"
],
"url": "https://www.exploit-db.com/exploits/52028"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://fortiguard.fortinet.com/encyclopedia/ips/56008"
},
{
"tags": [
"product"
],
"url": "https://www.aquatronica.com"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://vulncheck.com/advisories/aquatronica-controller-system-credential-leak"
}
],
"source": {
"discovery": "UNKNOWN"
},
"tags": [
"x_known-exploited-vulnerability"
],
"title": "Aquatronica Controller System Complete Information Disclosure",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"assignerShortName": "VulnCheck",
"cveId": "CVE-2025-25037",
"datePublished": "2025-06-20T18:35:19.243Z",
"dateReserved": "2025-01-31T18:32:36.214Z",
"dateUpdated": "2026-07-28T01:47:56.966Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2025-25037",
"date": "2026-11-17",
"epss": "0.01538",
"percentile": "0.75315"
},
"nvd": {
"cve": {
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"modules": [
"Web Management Interface (tcp.php endpoint)"
],
"product": "Aquatronica Controller System",
"vendor": "Aquatronica",
"versions": [
{
"lessThanOrEqual": "5.1.6",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"source": "disclosure@vulncheck.com"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "An information disclosure vulnerability exists in Aquatronica Controller System firmware versions \u003c= 5.1.6 and web interface versions \u003c= 2.0. The tcp.php endpoint fails to restrict unauthenticated access, allowing remote attackers to issue crafted POST requests and retrieve sensitive configuration data, including plaintext administrative credentials. Exploitation of this flaw can lead to full compromise of the system, enabling unauthorized manipulation of connected devices and aquarium parameters."
},
{
"lang": "es",
"value": "Existe una vulnerabilidad de divulgaci\u00f3n de informaci\u00f3n en las versiones de firmware de Aquatronica Controller System anteriores a la 5.1.6 y anteriores a la 2.0 de la interfaz web. El endpoint tcp.php no restringe el acceso no autenticado, lo que permite a atacantes remotos emitir solicitudes POST manipuladas y recuperar datos de configuraci\u00f3n confidenciales, incluyendo credenciales administrativas en texto plano. La explotaci\u00f3n de esta vulnerabilidad puede comprometer por completo el sistema, lo que permite la manipulaci\u00f3n no autorizada de los dispositivos conectados y los par\u00e1metros del acuario."
}
],
"id": "CVE-2025-25037",
"lastModified": "2026-06-17T09:00:10.840",
"metrics": {
"cvssMetricV40": [
{
"cvssData": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"availabilityRequirement": "NOT_DEFINED",
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"confidentialityRequirement": "NOT_DEFINED",
"exploitMaturity": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "HIGH",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"source": "disclosure@vulncheck.com",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-25037",
"options": [
{
"exploitation": "poc"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-06-23T20:32:57.296954Z",
"version": "2.0.3"
}
}
]
},
"published": "2025-06-20T19:15:35.870",
"references": [
{
"source": "disclosure@vulncheck.com",
"url": "https://fortiguard.fortinet.com/encyclopedia/ips/56008"
},
{
"source": "disclosure@vulncheck.com",
"url": "https://vulncheck.com/advisories/aquatronica-controller-system-credential-leak"
},
{
"source": "disclosure@vulncheck.com",
"url": "https://www.aquatronica.com"
},
{
"source": "disclosure@vulncheck.com",
"url": "https://www.exploit-db.com/exploits/52028"
},
{
"source": "disclosure@vulncheck.com",
"url": "https://www.zeroscience.mk/en/vulnerabilities/ZSL-2024-5824.php"
}
],
"sourceIdentifier": "disclosure@vulncheck.com",
"vulnStatus": "Deferred",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-200"
}
],
"source": "disclosure@vulncheck.com",
"type": "Secondary"
}
]
}
},
"redhat_vex": {
"current_release_date": "2026-04-07T17:04:41+00:00",
"cve": "CVE-2025-25037",
"id": "CVE-2025-25037",
"initial_release_date": "2025-01-01T00:00:00+00:00",
"product_status:known_not_affected": "1",
"source": "Red Hat CSAF VEX",
"status": "final",
"title": "Aquatronica Controller System Complete Information Disclosure",
"url": "https://security.access.redhat.com/data/csaf/v2/vex/2025/cve-2025-25037.json",
"version": "3"
},
"vulnrichment": {
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-25037",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-06-23T20:32:57.296954Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-23T20:33:07.611Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"modules": [
"Web Management Interface (tcp.php endpoint)"
],
"product": "Aquatronica Controller System",
"vendor": "Aquatronica",
"versions": [
{
"lessThanOrEqual": "5.1.6",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:aviatrix:controller:*:*:*:*:*:*:*:*",
"versionEndIncluding": "5.1.6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Gjoko Krstic"
}
],
"datePublic": "2024-05-31T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An information disclosure vulnerability exists in Aquatronica Controller System firmware versions \u003c= 5.1.6 and web interface versions \u003c= 2.0. The tcp.php endpoint fails to restrict unauthenticated access, allowing remote attackers to issue crafted POST requests and retrieve sensitive configuration data, including plaintext administrative credentials. Exploitation of this flaw can lead to full compromise of the system, enabling unauthorized manipulation of connected devices and aquarium parameters."
}
],
"value": "An information disclosure vulnerability exists in Aquatronica Controller System firmware versions \u003c= 5.1.6 and web interface versions \u003c= 2.0. The tcp.php endpoint fails to restrict unauthenticated access, allowing remote attackers to issue crafted POST requests and retrieve sensitive configuration data, including plaintext administrative credentials. Exploitation of this flaw can lead to full compromise of the system, enabling unauthorized manipulation of connected devices and aquarium parameters."
}
],
"impacts": [
{
"capecId": "CAPEC-1",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-1 Accessing Functionality Not Properly Constrained by ACLs"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "HIGH",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:H/SI:H/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-200",
"description": "CWE-200 Exposure of Sensitive Information to an Unauthorized Actor",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-28T01:47:56.966Z",
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"shortName": "VulnCheck"
},
"references": [
{
"tags": [
"exploit",
"third-party-advisory"
],
"url": "https://www.zeroscience.mk/en/vulnerabilities/ZSL-2024-5824.php"
},
{
"tags": [
"exploit",
"third-party-advisory"
],
"url": "https://www.exploit-db.com/exploits/52028"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://fortiguard.fortinet.com/encyclopedia/ips/56008"
},
{
"tags": [
"product"
],
"url": "https://www.aquatronica.com"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://vulncheck.com/advisories/aquatronica-controller-system-credential-leak"
}
],
"source": {
"discovery": "UNKNOWN"
},
"tags": [
"x_known-exploited-vulnerability"
],
"title": "Aquatronica Controller System Complete Information Disclosure",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"assignerShortName": "VulnCheck",
"cveId": "CVE-2025-25037",
"datePublished": "2025-06-20T18:35:19.243Z",
"dateReserved": "2025-01-31T18:32:36.214Z",
"dateUpdated": "2026-07-28T01:47:56.966Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
}
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.