CVE-2025-20049 (GCVE-0-2025-20049)

Vulnerability from cvelistv5 – Published: 2025-02-28 17:04 – Updated: 2025-02-28 21:48
VLAI
Title
Dario Health USB-C Blood Glucose Monitoring System Starter Kit Android Application Cross-site Scripting
Summary
The Dario Health portal service application is vulnerable to XSS, which could allow an attacker to obtain sensitive information.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-02-28 21:48 UTC
CWE
  • CWE-79 - Cross-site Scripting
Assigner
icscert CNA under the icscert root
CNA scorecard B 75/100 over 336 records in the last 180 days details
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-20049",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-28T21:48:07.239321Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-28T21:48:28.315Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Dario Application Database and Internet-based Server Infrastructure",
          "vendor": "Dario Health",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Noah Cutler and Manuel Del Rio of Accenture reported these vulnerabilities to CISA."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eThe Dario Health portal service application is vulnerable to XSS, which could allow an attacker to obtain sensitive information.\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e"
            }
          ],
          "value": "The Dario Health portal service application is vulnerable to XSS, which could allow an attacker to obtain sensitive information."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:C/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "HIGH",
            "attackRequirements": "PRESENT",
            "attackVector": "NETWORK",
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "HIGH",
            "subConfidentialityImpact": "HIGH",
            "subIntegrityImpact": "HIGH",
            "userInteraction": "ACTIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:H/AT:P/PR:L/UI:A/VC:H/VI:N/VA:N/SC:H/SI:H/SA:H",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Cross-site Scripting",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-02-28T17:13:18.822Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-25-058-01"
        },
        {
          "url": "https://www.dariohealth.com/contact/"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDario Health recommends users update their Dario Health Android mobile application to the latest version. No other actions are required by users.\u003c/span\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "Dario Health recommends users update their Dario Health Android mobile application to the latest version. No other actions are required by users."
        }
      ],
      "source": {
        "advisory": "ICSMA-25-058-01",
        "discovery": "EXTERNAL"
      },
      "title": "Dario Health USB-C Blood Glucose Monitoring System Starter Kit Android Application Cross-site Scripting",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eDario Health recommends users perform the following mitigations:\u0026nbsp; \u003cbr\u003e\u003c/p\u003e\u003cul\u003e\u003cli\u003eUpdate the application from trusted sources.\u0026nbsp; \u003cbr\u003e\u003c/li\u003e\u003cli\u003eDon\u0027t use rooted/jailbroken devices.\u0026nbsp; \u003cbr\u003e\u003c/li\u003e\u003cli\u003eAvoid public untrusted network.\u0026nbsp; \u003cbr\u003e\u003c/li\u003e\u003cli\u003eFor more information \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.dariohealth.com/contact/\"\u003econtact Dario Health\u003c/a\u003e\u0026nbsp;directly.\u0026nbsp; \u003cbr\u003e\u003c/li\u003e\u003c/ul\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "Dario Health recommends users perform the following mitigations:\u00a0 \n\n\n  *  Update the application from trusted sources.\u00a0 \n\n  *  Don\u0027t use rooted/jailbroken devices.\u00a0 \n\n  *  Avoid public untrusted network.\u00a0 \n\n  *  For more information  contact Dario Health https://www.dariohealth.com/contact/ \u00a0directly."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2025-20049",
    "datePublished": "2025-02-28T17:04:11.352Z",
    "dateReserved": "2025-01-27T21:33:08.440Z",
    "dateUpdated": "2025-02-28T21:48:28.315Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2025-20049",
      "date": "2026-11-28",
      "epss": "0.00527",
      "percentile": "0.38074"
    },
    "nvd": {
      "cve": {
        "affected": [
          {
            "affectedData": [
              {
                "defaultStatus": "unaffected",
                "product": "Dario Application Database and Internet-based Server Infrastructure",
                "vendor": "Dario Health",
                "versions": [
                  {
                    "status": "affected",
                    "version": "All versions"
                  }
                ]
              }
            ],
            "source": "ics-cert@hq.dhs.gov"
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "The Dario Health portal service application is vulnerable to XSS, which could allow an attacker to obtain sensitive information."
          },
          {
            "lang": "es",
            "value": "La aplicaci\u00f3n de servicio del portal Dario Health es vulnerable a XSS, lo que podr\u00eda permitir a un atacante obtener informaci\u00f3n confidencial."
          }
        ],
        "id": "CVE-2025-20049",
        "lastModified": "2026-06-17T08:40:35.080",
        "metrics": {
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 5.8,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "LOW",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:C/C:H/I:N/A:N",
                "version": "3.1"
              },
              "exploitabilityScore": 1.3,
              "impactScore": 4.0,
              "source": "ics-cert@hq.dhs.gov",
              "type": "Secondary"
            }
          ],
          "cvssMetricV40": [
            {
              "cvssData": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "HIGH",
                "attackRequirements": "PRESENT",
                "attackVector": "NETWORK",
                "availabilityRequirement": "NOT_DEFINED",
                "baseScore": 7.1,
                "baseSeverity": "HIGH",
                "confidentialityRequirement": "NOT_DEFINED",
                "exploitMaturity": "NOT_DEFINED",
                "integrityRequirement": "NOT_DEFINED",
                "modifiedAttackComplexity": "NOT_DEFINED",
                "modifiedAttackRequirements": "NOT_DEFINED",
                "modifiedAttackVector": "NOT_DEFINED",
                "modifiedPrivilegesRequired": "NOT_DEFINED",
                "modifiedSubAvailabilityImpact": "NOT_DEFINED",
                "modifiedSubConfidentialityImpact": "NOT_DEFINED",
                "modifiedSubIntegrityImpact": "NOT_DEFINED",
                "modifiedUserInteraction": "NOT_DEFINED",
                "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
                "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
                "modifiedVulnIntegrityImpact": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "ACTIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:H/AT:P/PR:L/UI:A/VC:H/VI:N/VA:N/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "source": "ics-cert@hq.dhs.gov",
              "type": "Secondary"
            }
          ],
          "ssvcV203": [
            {
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "ssvcData": {
                "id": "CVE-2025-20049",
                "options": [
                  {
                    "exploitation": "none"
                  },
                  {
                    "automatable": "no"
                  },
                  {
                    "technicalImpact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-28T21:48:07.239321Z",
                "version": "2.0.3"
              }
            }
          ]
        },
        "published": "2025-02-28T17:15:16.277",
        "references": [
          {
            "source": "ics-cert@hq.dhs.gov",
            "url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-25-058-01"
          },
          {
            "source": "ics-cert@hq.dhs.gov",
            "url": "https://www.dariohealth.com/contact/"
          }
        ],
        "sourceIdentifier": "ics-cert@hq.dhs.gov",
        "vulnStatus": "Deferred",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-79"
              }
            ],
            "source": "ics-cert@hq.dhs.gov",
            "type": "Secondary"
          }
        ]
      }
    },
    "redhat_vex": {
      "current_release_date": "2025-05-28T16:49:20+00:00",
      "cve": "CVE-2025-20049",
      "id": "CVE-2025-20049",
      "initial_release_date": "2025-01-01T00:00:00+00:00",
      "product_status:known_not_affected": "1",
      "source": "Red Hat CSAF VEX",
      "status": "final",
      "title": "Dario Health USB-C Blood Glucose Monitoring System Starter Kit Android Application Cross-site Scripting",
      "url": "https://security.access.redhat.com/data/csaf/v2/vex/2025/cve-2025-20049.json",
      "version": "3"
    },
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-20049",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-02-28T21:48:07.239321Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-02-28T21:48:19.958Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Dario Application Database and Internet-based Server Infrastructure",
              "vendor": "Dario Health",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Noah Cutler and Manuel Del Rio of Accenture reported these vulnerabilities to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eThe Dario Health portal service application is vulnerable to XSS, which could allow an attacker to obtain sensitive information.\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e"
                }
              ],
              "value": "The Dario Health portal service application is vulnerable to XSS, which could allow an attacker to obtain sensitive information."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 5.8,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "LOW",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:C/C:H/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "HIGH",
                "attackRequirements": "PRESENT",
                "attackVector": "NETWORK",
                "baseScore": 7.1,
                "baseSeverity": "HIGH",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "ACTIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:H/AT:P/PR:L/UI:A/VC:H/VI:N/VA:N/SC:H/SI:H/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-79",
                  "description": "CWE-79 Cross-site Scripting",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-02-28T17:13:18.822Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-25-058-01"
            },
            {
              "url": "https://www.dariohealth.com/contact/"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDario Health recommends users update their Dario Health Android mobile application to the latest version. No other actions are required by users.\u003c/span\u003e\n\n\u003cbr\u003e"
                }
              ],
              "value": "Dario Health recommends users update their Dario Health Android mobile application to the latest version. No other actions are required by users."
            }
          ],
          "source": {
            "advisory": "ICSMA-25-058-01",
            "discovery": "EXTERNAL"
          },
          "title": "Dario Health USB-C Blood Glucose Monitoring System Starter Kit Android Application Cross-site Scripting",
          "workarounds": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eDario Health recommends users perform the following mitigations:\u0026nbsp; \u003cbr\u003e\u003c/p\u003e\u003cul\u003e\u003cli\u003eUpdate the application from trusted sources.\u0026nbsp; \u003cbr\u003e\u003c/li\u003e\u003cli\u003eDon\u0027t use rooted/jailbroken devices.\u0026nbsp; \u003cbr\u003e\u003c/li\u003e\u003cli\u003eAvoid public untrusted network.\u0026nbsp; \u003cbr\u003e\u003c/li\u003e\u003cli\u003eFor more information \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.dariohealth.com/contact/\"\u003econtact Dario Health\u003c/a\u003e\u0026nbsp;directly.\u0026nbsp; \u003cbr\u003e\u003c/li\u003e\u003c/ul\u003e\n\n\u003cbr\u003e"
                }
              ],
              "value": "Dario Health recommends users perform the following mitigations:\u00a0 \n\n\n  *  Update the application from trusted sources.\u00a0 \n\n  *  Don\u0027t use rooted/jailbroken devices.\u00a0 \n\n  *  Avoid public untrusted network.\u00a0 \n\n  *  For more information  contact Dario Health https://www.dariohealth.com/contact/ \u00a0directly."
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2025-20049",
        "datePublished": "2025-02-28T17:04:11.352Z",
        "dateReserved": "2025-01-27T21:33:08.440Z",
        "dateUpdated": "2025-02-28T21:48:28.315Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Solutions

CNA · icscert
Dario Health recommends users update their Dario Health Android mobile application to the latest version. No other actions are required by users.

Workarounds

CNA · icscert
Dario Health recommends users perform the following mitigations:  * Update the application from trusted sources.  * Don't use rooted/jailbroken devices.  * Avoid public untrusted network.  * For more information contact Dario Health https://www.dariohealth.com/contact/  directly.

Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline

Sightings and recorded dates, grouped by day · UTC

JSON
How durations are calculated

Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation. The method is described in a publication.

Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.

Events included in the timeline

Loading timeline…


    Loading…

    Loading…

    Loading…

    Related by attack behaviour

    Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.