CVE-2024-6077 (GCVE-0-2024-6077)

Vulnerability from cvelistv5 – Published: 2024-09-12 19:59 – Updated: 2024-09-12 21:01
VLAI
Title
Rockwell Automation ControlLogix/GuardLogix 5580 and CompactLogix/Compact GuardLogix® 5380 Vulnerable to DoS vulnerability via CIP
Summary
A denial-of-service vulnerability exists in the Rockwell Automation affected products when specially crafted packets are sent to the CIP Security Object. If exploited the device will become unavailable and require a factory reset to recover.
SSVC
Exploitation: none Automatable: yes Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-09-12 20:22 UTC
CWE
  • CWE-20 - Improper Input Validation
Assigner
Rockwell CNA under the icscert root
CNA scorecard C 74/100 over 47 records in the last 180 days details
Impacted products
Vendor Product Version CPE status
Rockwell Automation CompactLogix 5380 Affected: v.32 .011
guessed Create a notification for this product.
Rockwell Automation CompactLogix 5380 Process Affected: v.33.011
guessed Create a notification for this product.
Rockwell Automation Compact GuardLogix 5380 SIL 2 Affected: v.32.013
guessed Create a notification for this product.
Rockwell Automation Compact GuardLogix 5380 SIL 3 Affected: v.32.011
guessed Create a notification for this product.
Rockwell Automation CompactLogix 5480 Affected: v.32.011
guessed Create a notification for this product.
Rockwell Automation ControlLogix® 5580 Affected: v.32.011
guessed Create a notification for this product.
Rockwell Automation ControlLogix® 5580 Process Affected: v.33.011
guessed Create a notification for this product.
Rockwell Automation GuardLogix 5580 Affected: v.32.011
guessed Create a notification for this product.
Rockwell Automation 1756-EN4 Affected: v2.001
guessed Create a notification for this product.
rockwellautomation compactlogix_5480_firmware Affected: 32 .011 , < 33.017 (custom)
Affected: 34.0 , < 34.014 (custom)
Affected: 35.0 , < 35.013 (custom)
Affected: 36.0 , < 36.011 (custom)
    cpe:2.3:o:rockwellautomation:controllogix_5580_firmware:*:*:*:*:*:*:*:*
    cpe:2.3:o:rockwellautomation:guardlogix_5580_firmware:*:*:*:*:*:*:*:*
    cpe:2.3:o:rockwellautomation:compact_guardlogix_5380_sil3_firmware:*:*:*:*:*:*:*:*
    cpe:2.3:o:rockwellautomation:compactlogix_5380_firmware:*:*:*:*:*:*:*:*
    cpe:2.3:o:rockwellautomation:compactlogix_5480_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
rockwellautomation compactlogix_5380_process_firmware Affected: 33.011 , < 33.017 (custom)
Affected: 34.0 , < 34.014 (custom)
Affected: 35.0 , < 35.013 (custom)
Affected: 36.0 , < 36.011 (custom)
    cpe:2.3:o:rockwellautomation:controllogix_5580_process_firmware:*:*:*:*:*:*:*:*
    cpe:2.3:o:rockwellautomation:compactlogix_5380_process_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
rockwellautomation compact_guardlogix_5380_sil2_firmware Affected: 32.013 , < 33.017 (custom)
Affected: 34.0 , < 34.014 (custom)
Affected: 35.0 , < 35.013 (custom)
Affected: 36.0 , < 36.011 (custom)
    cpe:2.3:o:rockwellautomation:compact_guardlogix_5380_sil2_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
rockwellautomation 1756-en4_firmware Affected: 2.001 , < 6.001 (custom)
    cpe:2.3:o:rockwellautomation:1756-en4_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
Date Public
2024-09-12 13:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:rockwellautomation:controllogix_5580_firmware:*:*:*:*:*:*:*:*",
              "cpe:2.3:o:rockwellautomation:guardlogix_5580_firmware:*:*:*:*:*:*:*:*",
              "cpe:2.3:o:rockwellautomation:compact_guardlogix_5380_sil3_firmware:*:*:*:*:*:*:*:*",
              "cpe:2.3:o:rockwellautomation:compactlogix_5380_firmware:*:*:*:*:*:*:*:*",
              "cpe:2.3:o:rockwellautomation:compactlogix_5480_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unaffected",
            "product": "compactlogix_5480_firmware",
            "vendor": "rockwellautomation",
            "versions": [
              {
                "lessThan": "33.017",
                "status": "affected",
                "version": "32 .011",
                "versionType": "custom"
              },
              {
                "lessThan": "34.014",
                "status": "affected",
                "version": "34.0",
                "versionType": "custom"
              },
              {
                "lessThan": "35.013",
                "status": "affected",
                "version": "35.0",
                "versionType": "custom"
              },
              {
                "lessThan": "36.011",
                "status": "affected",
                "version": "36.0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:rockwellautomation:controllogix_5580_process_firmware:*:*:*:*:*:*:*:*",
              "cpe:2.3:o:rockwellautomation:compactlogix_5380_process_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unaffected",
            "product": "compactlogix_5380_process_firmware",
            "vendor": "rockwellautomation",
            "versions": [
              {
                "lessThan": "33.017",
                "status": "affected",
                "version": "33.011",
                "versionType": "custom"
              },
              {
                "lessThan": "34.014",
                "status": "affected",
                "version": "34.0",
                "versionType": "custom"
              },
              {
                "lessThan": "35.013",
                "status": "affected",
                "version": "35.0",
                "versionType": "custom"
              },
              {
                "lessThan": "36.011",
                "status": "affected",
                "version": "36.0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:rockwellautomation:compact_guardlogix_5380_sil2_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unaffected",
            "product": "compact_guardlogix_5380_sil2_firmware",
            "vendor": "rockwellautomation",
            "versions": [
              {
                "lessThan": "33.017",
                "status": "affected",
                "version": "32.013",
                "versionType": "custom"
              },
              {
                "lessThan": "34.014",
                "status": "affected",
                "version": "34.0",
                "versionType": "custom"
              },
              {
                "lessThan": "35.013",
                "status": "affected",
                "version": "35.0",
                "versionType": "custom"
              },
              {
                "lessThan": "36.011",
                "status": "affected",
                "version": "36.0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:rockwellautomation:1756-en4_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unaffected",
            "product": "1756-en4_firmware",
            "vendor": "rockwellautomation",
            "versions": [
              {
                "lessThan": "6.001",
                "status": "affected",
                "version": "2.001",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-6077",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-09-12T20:22:58.224200Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-09-12T21:01:50.254Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "CompactLogix 5380",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "v.32 .011"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CompactLogix 5380 Process",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "v.33.011"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Compact GuardLogix 5380 SIL 2",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "v.32.013"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Compact GuardLogix 5380 SIL 3",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "v.32.011"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CompactLogix 5480",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "v.32.011"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ControlLogix\u00ae 5580",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "v.32.011"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ControlLogix\u00ae 5580 Process",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "v.33.011"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "GuardLogix 5580",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "v.32.011"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "1756-EN4",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "v2.001"
            }
          ]
        }
      ],
      "datePublic": "2024-09-12T13:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA denial-of-service vulnerability exists in the Rockwell Automation affected products when specially crafted packets are sent to the CIP Security Object. If exploited the device will become unavailable and require a factory reset to recover. \u003c/span\u003e"
            }
          ],
          "value": "A denial-of-service vulnerability exists in the Rockwell Automation affected products when specially crafted packets are sent to the CIP Security Object. If exploited the device will become unavailable and require a factory reset to recover."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-153",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-153 Input Data Manipulation"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "NONE",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-20",
              "description": "CWE-20 Improper Input Validation",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-09-12T20:07:19.806Z",
        "orgId": "b73dd486-f505-4403-b634-40b078b177f0",
        "shortName": "Rockwell"
      },
      "references": [
        {
          "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1963.html"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003eAffected Family \u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003eFirst Known in Software/Firmware Version\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003eCorrected in Software/Firmware Version\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003eCompactLogix 5380\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003ev.32 .011\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003ev33.017, v34.014, v35.013, v36.011 and later\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003eCompactLogix 5380 Process \u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003ev.33.011\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003ev33.017, v34.014, v35.013, v36.011 and later\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003eCompact GuardLogix 5380 SIL 2 \u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003ev.32.013\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003ev33.017, v34.014, v35.013, v36.011 and later\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003eCompact GuardLogix 5380 SIL 3 \u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003ev.32.011\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003ev33.017, v34.014, v35.013, v36.011 and later\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003eCompactLogix 5480 \u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003ev.32.011\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003ev33.017, v34.014, v35.013, v36.011 and later\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003eControlLogix\u00ae 5580 \u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003ev.32.011\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003ev33.017, v34.014, v35.013, v36.011 and later\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003eControlLogix\u00ae 5580 Process \u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003ev.33.011\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003ev33.017, v34.014, v35.013, v36.011 and later\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003eGuardLogix 5580 \u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003ev.32.011\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003ev33.017, v34.014, v35.013, v36.011 and later\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e1756-EN4\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003ev2.001\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003ev6.001 and later\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003c/tbody\u003e\u003c/table\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\n\n\n\n\u003cp\u003eMitigations and Workarounds \u003cbr\u003eCustomers who are unable to upgrade to the corrected software versions are encouraged to apply the following risk mitigations. \u003c/p\u003e\u003cul\u003e\u003cli\u003e\u003cp\u003eUsers who do not wish to use CIP security can disable the feature per device. See \"Disable CIP Security\" in Chapter 2 of \"CIP Security with Rockwell Automation Products\" (publication SECURE-AT001)\u003c/p\u003e\u003c/li\u003e\u003c/ul\u003e\u003cp\u003eFor information on how to mitigate Security Risks on industrial automation control systems, we encourage customers to implement our suggested \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight\"\u003esecurity best practices\u003c/a\u003e\u0026nbsp;to minimize the risk of the vulnerability. Customers can use \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.cisa.gov/stakeholder-specific-vulnerability-categorization-ssvc\"\u003eStakeholder-Specific Vulnerability Categorization\u003c/a\u003e\u0026nbsp;to generate more environment-specific prioritization.\u003c/p\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "Affected Family \n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nFirst Known in Software/Firmware Version\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nCorrected in Software/Firmware Version\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nCompactLogix 5380\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nv.32 .011\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nv33.017, v34.014, v35.013, v36.011 and later\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nCompactLogix 5380 Process \n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nv.33.011\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nv33.017, v34.014, v35.013, v36.011 and later\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nCompact GuardLogix 5380 SIL 2 \n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nv.32.013\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nv33.017, v34.014, v35.013, v36.011 and later\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nCompact GuardLogix 5380 SIL 3 \n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nv.32.011\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nv33.017, v34.014, v35.013, v36.011 and later\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nCompactLogix 5480 \n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nv.32.011\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nv33.017, v34.014, v35.013, v36.011 and later\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nControlLogix\u00ae 5580 \n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nv.32.011\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nv33.017, v34.014, v35.013, v36.011 and later\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nControlLogix\u00ae 5580 Process \n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nv.33.011\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nv33.017, v34.014, v35.013, v36.011 and later\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nGuardLogix 5580 \n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nv.32.011\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nv33.017, v34.014, v35.013, v36.011 and later\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n1756-EN4\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nv2.001\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nv6.001 and later\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\n\n\n\nMitigations and Workarounds \nCustomers who are unable to upgrade to the corrected software versions are encouraged to apply the following risk mitigations. \n\n  *  Users who do not wish to use CIP security can disable the feature per device. See \"Disable CIP Security\" in Chapter 2 of \"CIP Security with Rockwell Automation Products\" (publication SECURE-AT001)\n\n\n\n\nFor information on how to mitigate Security Risks on industrial automation control systems, we encourage customers to implement our suggested  security best practices https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight \u00a0to minimize the risk of the vulnerability. Customers can use  Stakeholder-Specific Vulnerability Categorization https://www.cisa.gov/stakeholder-specific-vulnerability-categorization-ssvc \u00a0to generate more environment-specific prioritization."
        }
      ],
      "source": {
        "advisory": "SD1963",
        "discovery": "INTERNAL"
      },
      "title": "Rockwell Automation ControlLogix/GuardLogix 5580 and CompactLogix/Compact GuardLogix\u00ae 5380 Vulnerable to DoS vulnerability via CIP",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
    "assignerShortName": "Rockwell",
    "cveId": "CVE-2024-6077",
    "datePublished": "2024-09-12T19:59:40.368Z",
    "dateReserved": "2024-06-17T16:21:32.155Z",
    "dateUpdated": "2024-09-12T21:01:50.254Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2024-6077",
      "date": "2026-11-16",
      "epss": "0.00558",
      "percentile": "0.47056"
    },
    "nvd": {
      "cve": {
        "affected": [
          {
            "affectedData": [
              {
                "defaultStatus": "unaffected",
                "product": "CompactLogix 5380",
                "vendor": "Rockwell Automation",
                "versions": [
                  {
                    "status": "affected",
                    "version": "v.32 .011"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "product": "CompactLogix 5380 Process",
                "vendor": "Rockwell Automation",
                "versions": [
                  {
                    "status": "affected",
                    "version": "v.33.011"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "product": "Compact GuardLogix 5380 SIL 2",
                "vendor": "Rockwell Automation",
                "versions": [
                  {
                    "status": "affected",
                    "version": "v.32.013"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "product": "Compact GuardLogix 5380 SIL 3",
                "vendor": "Rockwell Automation",
                "versions": [
                  {
                    "status": "affected",
                    "version": "v.32.011"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "product": "CompactLogix 5480",
                "vendor": "Rockwell Automation",
                "versions": [
                  {
                    "status": "affected",
                    "version": "v.32.011"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "product": "ControlLogix\u00ae 5580",
                "vendor": "Rockwell Automation",
                "versions": [
                  {
                    "status": "affected",
                    "version": "v.32.011"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "product": "ControlLogix\u00ae 5580 Process",
                "vendor": "Rockwell Automation",
                "versions": [
                  {
                    "status": "affected",
                    "version": "v.33.011"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "product": "GuardLogix 5580",
                "vendor": "Rockwell Automation",
                "versions": [
                  {
                    "status": "affected",
                    "version": "v.32.011"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "product": "1756-EN4",
                "vendor": "Rockwell Automation",
                "versions": [
                  {
                    "status": "affected",
                    "version": "v2.001"
                  }
                ]
              }
            ],
            "source": "PSIRT@rockwellautomation.com"
          },
          {
            "affectedData": [
              {
                "cpes": [
                  "cpe:2.3:o:rockwellautomation:controllogix_5580_firmware:*:*:*:*:*:*:*:*",
                  "cpe:2.3:o:rockwellautomation:guardlogix_5580_firmware:*:*:*:*:*:*:*:*",
                  "cpe:2.3:o:rockwellautomation:compact_guardlogix_5380_sil3_firmware:*:*:*:*:*:*:*:*",
                  "cpe:2.3:o:rockwellautomation:compactlogix_5380_firmware:*:*:*:*:*:*:*:*",
                  "cpe:2.3:o:rockwellautomation:compactlogix_5480_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "compactlogix_5480_firmware",
                "vendor": "rockwellautomation",
                "versions": [
                  {
                    "lessThan": "33.017",
                    "status": "affected",
                    "version": "32 .011",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "34.014",
                    "status": "affected",
                    "version": "34.0",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "35.013",
                    "status": "affected",
                    "version": "35.0",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "36.011",
                    "status": "affected",
                    "version": "36.0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:rockwellautomation:controllogix_5580_process_firmware:*:*:*:*:*:*:*:*",
                  "cpe:2.3:o:rockwellautomation:compactlogix_5380_process_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "compactlogix_5380_process_firmware",
                "vendor": "rockwellautomation",
                "versions": [
                  {
                    "lessThan": "33.017",
                    "status": "affected",
                    "version": "33.011",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "34.014",
                    "status": "affected",
                    "version": "34.0",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "35.013",
                    "status": "affected",
                    "version": "35.0",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "36.011",
                    "status": "affected",
                    "version": "36.0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:rockwellautomation:compact_guardlogix_5380_sil2_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "compact_guardlogix_5380_sil2_firmware",
                "vendor": "rockwellautomation",
                "versions": [
                  {
                    "lessThan": "33.017",
                    "status": "affected",
                    "version": "32.013",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "34.014",
                    "status": "affected",
                    "version": "34.0",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "35.013",
                    "status": "affected",
                    "version": "35.0",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "36.011",
                    "status": "affected",
                    "version": "36.0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:rockwellautomation:1756-en4_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "1756-en4_firmware",
                "vendor": "rockwellautomation",
                "versions": [
                  {
                    "lessThan": "6.001",
                    "status": "affected",
                    "version": "2.001",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"
          }
        ],
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:rockwellautomation:compactlogix_5380_firmware:32.011:*:*:*:*:*:*:*",
                    "matchCriteriaId": "D389E07F-A04E-467A-8FE4-4DE8B69EF7EC",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:rockwellautomation:compactlogix_5380:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "EDD040ED-B44C-47D0-B4D4-729C378C4F68",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:rockwellautomation:compact_guardlogix_5380_sil_2_firmware:32.013:*:*:*:*:*:*:*",
                    "matchCriteriaId": "CCF40770-68D8-41E8-B0DC-61BEFD2DA987",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:rockwellautomation:compact_guardlogix_5380_sil_2:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "E594CDF6-0582-4D5C-B6AA-C8A2E752E29F",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:rockwellautomation:compact_guardlogix_5380_sil_3_firmware:32.011:*:*:*:*:*:*:*",
                    "matchCriteriaId": "7F2345A8-E3BD-45C2-AEE8-189C81D6C23F",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:rockwellautomation:compact_guardlogix_5380_sil_3:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "B82D842C-0930-41AA-83CD-5F235771AE4B",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:rockwellautomation:compactlogix_5480_firmware:32.011:*:*:*:*:*:*:*",
                    "matchCriteriaId": "D7EB2F5A-34D4-49C6-9B58-632DFA6B69E4",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:rockwellautomation:compactlogix_5480:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "80F4F5BE-07DF-402A-BF98-34FBA6A11968",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:rockwellautomation:controllogix_5580_firmware:33.011:*:*:*:*:*:*:*",
                    "matchCriteriaId": "F032C078-D896-47EC-8393-10803E832C18",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:rockwellautomation:controllogix_5580:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "51BB883B-B863-4D57-B1C0-FC7B3EBD1EA0",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:rockwellautomation:guardlogix_5580_firmware:32.011:*:*:*:*:*:*:*",
                    "matchCriteriaId": "BAE872BB-FC1F-4B70-92AD-B1213A347C89",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:rockwellautomation:guardlogix_5580:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "006B7683-9FDF-4748-BA28-2EA22613E092",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:rockwellautomation:1756-en4_firmware:2.001:*:*:*:*:*:*:*",
                    "matchCriteriaId": "B389BA8B-56CD-4614-BC77-02FC80981FA1",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:rockwellautomation:1756-en4:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "6935642C-4CBF-4B4F-A509-561B3E39A66B",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "A denial-of-service vulnerability exists in the Rockwell Automation affected products when specially crafted packets are sent to the CIP Security Object. If exploited the device will become unavailable and require a factory reset to recover."
          },
          {
            "lang": "es",
            "value": "Existe una vulnerabilidad de denegaci\u00f3n de servicio en los productos afectados de Rockwell Automation cuando se env\u00edan paquetes especialmente manipulados al objeto de seguridad CIP. Si se explota, el dispositivo dejar\u00e1 de estar disponible y ser\u00e1 necesario restablecer la configuraci\u00f3n de f\u00e1brica para recuperarse."
          }
        ],
        "id": "CVE-2024-6077",
        "lastModified": "2026-06-17T08:17:14.467",
        "metrics": {
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 3.9,
              "impactScore": 3.6,
              "source": "nvd@nist.gov",
              "type": "Primary"
            }
          ],
          "cvssMetricV40": [
            {
              "cvssData": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "availabilityRequirement": "NOT_DEFINED",
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "confidentialityRequirement": "NOT_DEFINED",
                "exploitMaturity": "NOT_DEFINED",
                "integrityRequirement": "NOT_DEFINED",
                "modifiedAttackComplexity": "NOT_DEFINED",
                "modifiedAttackRequirements": "NOT_DEFINED",
                "modifiedAttackVector": "NOT_DEFINED",
                "modifiedPrivilegesRequired": "NOT_DEFINED",
                "modifiedSubAvailabilityImpact": "NOT_DEFINED",
                "modifiedSubConfidentialityImpact": "NOT_DEFINED",
                "modifiedSubIntegrityImpact": "NOT_DEFINED",
                "modifiedUserInteraction": "NOT_DEFINED",
                "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
                "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
                "modifiedVulnIntegrityImpact": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "source": "PSIRT@rockwellautomation.com",
              "type": "Secondary"
            }
          ],
          "ssvcV203": [
            {
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "ssvcData": {
                "id": "CVE-2024-6077",
                "options": [
                  {
                    "exploitation": "none"
                  },
                  {
                    "automatable": "yes"
                  },
                  {
                    "technicalImpact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-09-12T20:22:58.224200Z",
                "version": "2.0.3"
              }
            }
          ]
        },
        "published": "2024-09-12T20:15:05.440",
        "references": [
          {
            "source": "PSIRT@rockwellautomation.com",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1963.html"
          }
        ],
        "sourceIdentifier": "PSIRT@rockwellautomation.com",
        "vulnStatus": "Analyzed",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-20"
              }
            ],
            "source": "PSIRT@rockwellautomation.com",
            "type": "Secondary"
          },
          {
            "description": [
              {
                "lang": "en",
                "value": "NVD-CWE-noinfo"
              }
            ],
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      }
    },
    "redhat_vex": {
      "current_release_date": "2025-05-28T22:02:44+00:00",
      "cve": "CVE-2024-6077",
      "id": "CVE-2024-6077",
      "initial_release_date": "2024-09-12T13:00:00+00:00",
      "product_status:known_not_affected": "1",
      "source": "Red Hat CSAF VEX",
      "status": "final",
      "title": "Rockwell Automation ControlLogix/GuardLogix 5580 and CompactLogix/Compact GuardLogix\u00ae 5380 Vulnerable to DoS vulnerability via CIP",
      "url": "https://security.access.redhat.com/data/csaf/v2/vex/2024/cve-2024-6077.json",
      "version": "3"
    },
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:o:rockwellautomation:controllogix_5580_firmware:*:*:*:*:*:*:*:*",
                  "cpe:2.3:o:rockwellautomation:guardlogix_5580_firmware:*:*:*:*:*:*:*:*",
                  "cpe:2.3:o:rockwellautomation:compact_guardlogix_5380_sil3_firmware:*:*:*:*:*:*:*:*",
                  "cpe:2.3:o:rockwellautomation:compactlogix_5380_firmware:*:*:*:*:*:*:*:*",
                  "cpe:2.3:o:rockwellautomation:compactlogix_5480_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "compactlogix_5480_firmware",
                "vendor": "rockwellautomation",
                "versions": [
                  {
                    "lessThan": "33.017",
                    "status": "affected",
                    "version": "32 .011",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "34.014",
                    "status": "affected",
                    "version": "34.0",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "35.013",
                    "status": "affected",
                    "version": "35.0",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "36.011",
                    "status": "affected",
                    "version": "36.0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:rockwellautomation:controllogix_5580_process_firmware:*:*:*:*:*:*:*:*",
                  "cpe:2.3:o:rockwellautomation:compactlogix_5380_process_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "compactlogix_5380_process_firmware",
                "vendor": "rockwellautomation",
                "versions": [
                  {
                    "lessThan": "33.017",
                    "status": "affected",
                    "version": "33.011",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "34.014",
                    "status": "affected",
                    "version": "34.0",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "35.013",
                    "status": "affected",
                    "version": "35.0",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "36.011",
                    "status": "affected",
                    "version": "36.0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:rockwellautomation:compact_guardlogix_5380_sil2_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "compact_guardlogix_5380_sil2_firmware",
                "vendor": "rockwellautomation",
                "versions": [
                  {
                    "lessThan": "33.017",
                    "status": "affected",
                    "version": "32.013",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "34.014",
                    "status": "affected",
                    "version": "34.0",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "35.013",
                    "status": "affected",
                    "version": "35.0",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "36.011",
                    "status": "affected",
                    "version": "36.0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:rockwellautomation:1756-en4_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "1756-en4_firmware",
                "vendor": "rockwellautomation",
                "versions": [
                  {
                    "lessThan": "6.001",
                    "status": "affected",
                    "version": "2.001",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-6077",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-09-12T20:22:58.224200Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-09-12T20:31:09.370Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "CompactLogix 5380",
              "vendor": "Rockwell Automation",
              "versions": [
                {
                  "status": "affected",
                  "version": "v.32 .011"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CompactLogix 5380 Process",
              "vendor": "Rockwell Automation",
              "versions": [
                {
                  "status": "affected",
                  "version": "v.33.011"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Compact GuardLogix 5380 SIL 2",
              "vendor": "Rockwell Automation",
              "versions": [
                {
                  "status": "affected",
                  "version": "v.32.013"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Compact GuardLogix 5380 SIL 3",
              "vendor": "Rockwell Automation",
              "versions": [
                {
                  "status": "affected",
                  "version": "v.32.011"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CompactLogix 5480",
              "vendor": "Rockwell Automation",
              "versions": [
                {
                  "status": "affected",
                  "version": "v.32.011"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "ControlLogix\u00ae 5580",
              "vendor": "Rockwell Automation",
              "versions": [
                {
                  "status": "affected",
                  "version": "v.32.011"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "ControlLogix\u00ae 5580 Process",
              "vendor": "Rockwell Automation",
              "versions": [
                {
                  "status": "affected",
                  "version": "v.33.011"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "GuardLogix 5580",
              "vendor": "Rockwell Automation",
              "versions": [
                {
                  "status": "affected",
                  "version": "v.32.011"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "1756-EN4",
              "vendor": "Rockwell Automation",
              "versions": [
                {
                  "status": "affected",
                  "version": "v2.001"
                }
              ]
            }
          ],
          "datePublic": "2024-09-12T13:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA denial-of-service vulnerability exists in the Rockwell Automation affected products when specially crafted packets are sent to the CIP Security Object. If exploited the device will become unavailable and require a factory reset to recover. \u003c/span\u003e"
                }
              ],
              "value": "A denial-of-service vulnerability exists in the Rockwell Automation affected products when specially crafted packets are sent to the CIP Security Object. If exploited the device will become unavailable and require a factory reset to recover."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-153",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-153 Input Data Manipulation"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-20",
                  "description": "CWE-20 Improper Input Validation",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-09-12T20:07:19.806Z",
            "orgId": "b73dd486-f505-4403-b634-40b078b177f0",
            "shortName": "Rockwell"
          },
          "references": [
            {
              "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1963.html"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003eAffected Family \u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003eFirst Known in Software/Firmware Version\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003eCorrected in Software/Firmware Version\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003eCompactLogix 5380\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003ev.32 .011\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003ev33.017, v34.014, v35.013, v36.011 and later\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003eCompactLogix 5380 Process \u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003ev.33.011\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003ev33.017, v34.014, v35.013, v36.011 and later\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003eCompact GuardLogix 5380 SIL 2 \u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003ev.32.013\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003ev33.017, v34.014, v35.013, v36.011 and later\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003eCompact GuardLogix 5380 SIL 3 \u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003ev.32.011\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003ev33.017, v34.014, v35.013, v36.011 and later\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003eCompactLogix 5480 \u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003ev.32.011\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003ev33.017, v34.014, v35.013, v36.011 and later\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003eControlLogix\u00ae 5580 \u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003ev.32.011\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003ev33.017, v34.014, v35.013, v36.011 and later\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003eControlLogix\u00ae 5580 Process \u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003ev.33.011\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003ev33.017, v34.014, v35.013, v36.011 and later\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003eGuardLogix 5580 \u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003ev.32.011\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003ev33.017, v34.014, v35.013, v36.011 and later\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e1756-EN4\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003ev2.001\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003ev6.001 and later\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003c/tbody\u003e\u003c/table\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\n\n\n\n\u003cp\u003eMitigations and Workarounds \u003cbr\u003eCustomers who are unable to upgrade to the corrected software versions are encouraged to apply the following risk mitigations. \u003c/p\u003e\u003cul\u003e\u003cli\u003e\u003cp\u003eUsers who do not wish to use CIP security can disable the feature per device. See \"Disable CIP Security\" in Chapter 2 of \"CIP Security with Rockwell Automation Products\" (publication SECURE-AT001)\u003c/p\u003e\u003c/li\u003e\u003c/ul\u003e\u003cp\u003eFor information on how to mitigate Security Risks on industrial automation control systems, we encourage customers to implement our suggested \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight\"\u003esecurity best practices\u003c/a\u003e\u0026nbsp;to minimize the risk of the vulnerability. Customers can use \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.cisa.gov/stakeholder-specific-vulnerability-categorization-ssvc\"\u003eStakeholder-Specific Vulnerability Categorization\u003c/a\u003e\u0026nbsp;to generate more environment-specific prioritization.\u003c/p\u003e\n\n\u003cbr\u003e"
                }
              ],
              "value": "Affected Family \n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nFirst Known in Software/Firmware Version\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nCorrected in Software/Firmware Version\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nCompactLogix 5380\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nv.32 .011\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nv33.017, v34.014, v35.013, v36.011 and later\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nCompactLogix 5380 Process \n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nv.33.011\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nv33.017, v34.014, v35.013, v36.011 and later\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nCompact GuardLogix 5380 SIL 2 \n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nv.32.013\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nv33.017, v34.014, v35.013, v36.011 and later\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nCompact GuardLogix 5380 SIL 3 \n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nv.32.011\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nv33.017, v34.014, v35.013, v36.011 and later\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nCompactLogix 5480 \n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nv.32.011\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nv33.017, v34.014, v35.013, v36.011 and later\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nControlLogix\u00ae 5580 \n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nv.32.011\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nv33.017, v34.014, v35.013, v36.011 and later\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nControlLogix\u00ae 5580 Process \n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nv.33.011\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nv33.017, v34.014, v35.013, v36.011 and later\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nGuardLogix 5580 \n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nv.32.011\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nv33.017, v34.014, v35.013, v36.011 and later\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n1756-EN4\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nv2.001\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nv6.001 and later\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\n\n\n\nMitigations and Workarounds \nCustomers who are unable to upgrade to the corrected software versions are encouraged to apply the following risk mitigations. \n\n  *  Users who do not wish to use CIP security can disable the feature per device. See \"Disable CIP Security\" in Chapter 2 of \"CIP Security with Rockwell Automation Products\" (publication SECURE-AT001)\n\n\n\n\nFor information on how to mitigate Security Risks on industrial automation control systems, we encourage customers to implement our suggested  security best practices https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight \u00a0to minimize the risk of the vulnerability. Customers can use  Stakeholder-Specific Vulnerability Categorization https://www.cisa.gov/stakeholder-specific-vulnerability-categorization-ssvc \u00a0to generate more environment-specific prioritization."
            }
          ],
          "source": {
            "advisory": "SD1963",
            "discovery": "INTERNAL"
          },
          "title": "Rockwell Automation ControlLogix/GuardLogix 5580 and CompactLogix/Compact GuardLogix\u00ae 5380 Vulnerable to DoS vulnerability via CIP",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
        "assignerShortName": "Rockwell",
        "cveId": "CVE-2024-6077",
        "datePublished": "2024-09-12T19:59:40.368Z",
        "dateReserved": "2024-06-17T16:21:32.155Z",
        "dateUpdated": "2024-09-12T21:01:50.254Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Solutions

CNA · Rockwell
Affected Family         First Known in Software/Firmware Version         Corrected in Software/Firmware Version         CompactLogix 5380               v.32 .011         v33.017, v34.014, v35.013, v36.011 and later         CompactLogix 5380 Process         v.33.011         v33.017, v34.014, v35.013, v36.011 and later         Compact GuardLogix 5380 SIL 2         v.32.013         v33.017, v34.014, v35.013, v36.011 and later         Compact GuardLogix 5380 SIL 3         v.32.011         v33.017, v34.014, v35.013, v36.011 and later         CompactLogix 5480         v.32.011         v33.017, v34.014, v35.013, v36.011 and later         ControlLogix® 5580         v.32.011         v33.017, v34.014, v35.013, v36.011 and later         ControlLogix® 5580 Process         v.33.011         v33.017, v34.014, v35.013, v36.011 and later         GuardLogix 5580         v.32.011         v33.017, v34.014, v35.013, v36.011 and later         1756-EN4         v2.001         v6.001 and later       Mitigations and Workarounds Customers who are unable to upgrade to the corrected software versions are encouraged to apply the following risk mitigations. * Users who do not wish to use CIP security can disable the feature per device. See "Disable CIP Security" in Chapter 2 of "CIP Security with Rockwell Automation Products" (publication SECURE-AT001) For information on how to mitigate Security Risks on industrial automation control systems, we encourage customers to implement our suggested security best practices https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight  to minimize the risk of the vulnerability. Customers can use Stakeholder-Specific Vulnerability Categorization https://www.cisa.gov/stakeholder-specific-vulnerability-categorization-ssvc  to generate more environment-specific prioritization.

Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline

Sightings and recorded dates, grouped by day · UTC

JSON
How durations are calculated

Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.

Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.

Events included in the timeline

Loading timeline…


    Loading…

    Loading…

    Loading…

    Related by attack behaviour

    Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.