CVE-2024-5659 (GCVE-0-2024-5659)
Vulnerability from cvelistv5 – Published: 2024-06-14 16:42 – Updated: 2024-08-01 21:18- CWE-670 - Always-Incorrect Control Flow Implementation
| Vendor | Product | Version | CPE status | |
|---|---|---|---|---|
| Rockwell Automation | ControlLogix® 5580 |
Affected:
34.011
|
guessed | |
| Rockwell Automation | GuardLogix 5580 |
Affected:
34.011
|
guessed | |
| Rockwell Automation | 1756-EN4 |
Affected:
4.001
|
guessed | |
| Rockwell Automation | CompactLogix 5380 |
Affected:
34.011
|
guessed | |
| Rockwell Automation | Compact GuardLogix 5380 |
Affected:
34.011
|
guessed | |
| Rockwell Automation | CompactLogix 5480 |
Affected:
34.011
|
guessed | |
| rockwellautomation | controllogix_5580 |
Affected:
34.011
cpe:2.3:h:rockwellautomation:controllogix_5580:-:*:*:*:*:*:*:* |
||
| rockwellautomation | guardlogix_5580 |
Affected:
34.011
cpe:2.3:h:rockwellautomation:guardlogix_5580:-:*:*:*:*:*:*:* |
||
| rockwellautomation | 1756_en4 |
Affected:
4.001
cpe:2.3:a:rockwellautomation:1756_en4:0:*:*:*:*:*:*:* |
||
| rockwellautomation | compact_logix_5480 |
Affected:
34.011
cpe:2.3:a:rockwellautomation:compact_logix_5480:34.011:*:*:*:*:*:*:* |
||
| rockwellautomation | compact_guardlogix_5480 |
Affected:
34.011
cpe:2.3:a:rockwellautomation:compact_guardlogix_5480:34.011:*:*:*:*:*:*:* |
||
| rockwellautomation | compactlogix |
Affected:
5480
cpe:2.3:h:rockwellautomation:compactlogix:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:h:rockwellautomation:controllogix_5580:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "controllogix_5580",
"vendor": "rockwellautomation",
"versions": [
{
"status": "affected",
"version": "34.011"
}
]
},
{
"cpes": [
"cpe:2.3:h:rockwellautomation:guardlogix_5580:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "guardlogix_5580",
"vendor": "rockwellautomation",
"versions": [
{
"status": "affected",
"version": "34.011"
}
]
},
{
"cpes": [
"cpe:2.3:a:rockwellautomation:1756_en4:0:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "1756_en4",
"vendor": "rockwellautomation",
"versions": [
{
"status": "affected",
"version": "4.001"
}
]
},
{
"cpes": [
"cpe:2.3:a:rockwellautomation:compact_logix_5480:34.011:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "compact_logix_5480",
"vendor": "rockwellautomation",
"versions": [
{
"status": "affected",
"version": "34.011"
}
]
},
{
"cpes": [
"cpe:2.3:a:rockwellautomation:compact_guardlogix_5480:34.011:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "compact_guardlogix_5480",
"vendor": "rockwellautomation",
"versions": [
{
"status": "affected",
"version": "34.011"
}
]
},
{
"cpes": [
"cpe:2.3:h:rockwellautomation:compactlogix:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "compactlogix",
"vendor": "rockwellautomation",
"versions": [
{
"status": "affected",
"version": "5480"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-5659",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-06-15T19:57:53.882617Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-15T20:23:20.243Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T21:18:06.865Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1673.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "ControlLogix\u00ae 5580",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "34.011"
}
]
},
{
"defaultStatus": "unaffected",
"product": "GuardLogix 5580",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "34.011"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN4",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "4.001"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CompactLogix 5380",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "34.011"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Compact GuardLogix 5380",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "34.011"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CompactLogix 5480",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "34.011"
}
]
}
],
"datePublic": "2024-06-13T13:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eRockwell Automation was made aware of a vulnerability that causes all affected controllers on the same network to result in a major nonrecoverable fault(MNRF/Assert). This vulnerability could be exploited by sending \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\"\u003e\u003c/a\u003e\u003ca target=\"_blank\" rel=\"nofollow\"\u003e\u003c/a\u003e\u003ca target=\"_blank\" rel=\"nofollow\"\u003e\u003c/a\u003e\u003ca target=\"_blank\" rel=\"nofollow\"\u003eabnormal packets to the \u003c/a\u003e\u003ca target=\"_blank\" rel=\"nofollow\"\u003emDNS port.\u0026nbsp;\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eIf exploited, the availability of the device would be compromised.\u003c/span\u003e\n\n"
}
],
"value": "Rockwell Automation was made aware of a vulnerability that causes all affected controllers on the same network to result in a major nonrecoverable fault(MNRF/Assert). This vulnerability could be exploited by sending abnormal packets to the mDNS port.\u00a0If exploited, the availability of the device would be compromised."
}
],
"impacts": [
{
"capecId": "CAPEC-624",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-624 Hardware Fault Injection"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "ADJACENT",
"baseScore": 8.3,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-670",
"description": "CWE-670 Always-Incorrect Control Flow Implementation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-14T16:42:20.699Z",
"orgId": "b73dd486-f505-4403-b634-40b078b177f0",
"shortName": "Rockwell"
},
"references": [
{
"url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1673.html"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003eAffected Product\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003eFirst Known in firmware revision\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003eCorrected in firmware revision\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003eControlLogix\u00ae 5580\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003eV34.011\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003eV34.014, V35.013, V36.011 and later\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003eGuardLogix 5580\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003eV34.011\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003eV34.014, V35.013, V36.011 and later \u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003e1756-EN4\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003eV4.001\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003eV6.001 and later\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003eCompactLogix 5380\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003eV34.011\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003eV34.014, V35.013, V36.011 and later \u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\"\u003e\u003c/a\u003e\u003ca target=\"_blank\" rel=\"nofollow\"\u003eCompact GuardLogix \u003c/a\u003e\u003cb\u003e\u0026nbsp;\u003c/b\u003e5380\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003eV34.011\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003eV34.014, V35.013, V36.011 and later \u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003eCompactLogix 5480\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003eV34.011\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003eV34.014, V35.013, V36.011 and later\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003c/tbody\u003e\u003c/table\u003e\u003cbr\u003e\n\n\u003cp\u003e\u003cb\u003eMitigations and Workarounds\u003c/b\u003e\u003c/p\u003e\u003cp\u003eUsers using the affected software and who are not able to upgrade to one of the corrected versions are encouraged to apply the risk mitigations, where possible.\u003c/p\u003e\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; Users who do not use \u003ca target=\"_blank\" rel=\"nofollow\"\u003e\u003c/a\u003e\u003ca target=\"_blank\" rel=\"nofollow\"\u003eAutomatic Policy Deployment (APD)\u003c/a\u003e\u0026nbsp;should block \u003ca target=\"_blank\" rel=\"nofollow\"\u003e\u003c/a\u003e\u003ca target=\"_blank\" rel=\"nofollow\"\u003e\u003c/a\u003e\u003ca target=\"_blank\" rel=\"nofollow\"\u003e\u003c/a\u003e\u003ca target=\"_blank\" rel=\"nofollow\"\u003emDNS port, 5353\u003c/a\u003e\u0026nbsp;to help prevent communication.\u003c/p\u003e\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; Enable CIP \u003ca target=\"_blank\" rel=\"nofollow\"\u003e\u003c/a\u003e\u003ca target=\"_blank\" rel=\"nofollow\"\u003e\u003c/a\u003e\u003ca target=\"_blank\" rel=\"nofollow\"\u003e\u003c/a\u003e\u003ca target=\"_blank\" rel=\"nofollow\"\u003e\u003c/a\u003e\u003ca target=\"_blank\" rel=\"nofollow\"\u003eSecurity. \u003c/a\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://literature.rockwellautomation.com/idc/groups/literature/documents/at/secure-at001_-en-p.pdf\"\u003eCIP Security with Rockwell Automation Products Application Technique\u003c/a\u003e\u003c/p\u003e\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight\"\u003eSecurity Best Practices\u003c/a\u003e\u003c/p\u003e\n\n\u003cbr\u003e"
}
],
"value": "Affected Product\n\nFirst Known in firmware revision\n\nCorrected in firmware revision\n\nControlLogix\u00ae 5580\n\nV34.011\n\nV34.014, V35.013, V36.011 and later\n\nGuardLogix 5580\n\nV34.011\n\nV34.014, V35.013, V36.011 and later \n\n1756-EN4\n\nV4.001\n\nV6.001 and later\n\nCompactLogix 5380\n\nV34.011\n\nV34.014, V35.013, V36.011 and later \n\nCompact GuardLogix \u00a05380\n\nV34.011\n\nV34.014, V35.013, V36.011 and later \n\nCompactLogix 5480\n\nV34.011\n\nV34.014, V35.013, V36.011 and later\n\n\n\n\nMitigations and Workarounds\n\nUsers using the affected software and who are not able to upgrade to one of the corrected versions are encouraged to apply the risk mitigations, where possible.\n\n\u00b7 \u00a0 \u00a0 \u00a0 Users who do not use CIP Security with Rockwell Automation Products Application Technique https://literature.rockwellautomation.com/idc/groups/literature/documents/at/secure-at001_-en-p.pdf \n\n\u00b7 \u00a0 \u00a0 \u00a0 Security Best Practices https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Rockwell Automation Multicast Request Causes major nonrecoverable fault on Select Controllers",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
"assignerShortName": "Rockwell",
"cveId": "CVE-2024-5659",
"datePublished": "2024-06-14T16:42:20.699Z",
"dateReserved": "2024-06-05T16:47:18.275Z",
"dateUpdated": "2024-08-01T21:18:06.865Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2024-5659",
"date": "2026-11-16",
"epss": "0.00311",
"percentile": "0.24367"
},
"nvd": {
"cve": {
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "ControlLogix\u00ae 5580",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "34.011"
}
]
},
{
"defaultStatus": "unaffected",
"product": "GuardLogix 5580",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "34.011"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN4",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "4.001"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CompactLogix 5380",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "34.011"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Compact GuardLogix 5380",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "34.011"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CompactLogix 5480",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "34.011"
}
]
}
],
"source": "PSIRT@rockwellautomation.com"
},
{
"affectedData": [
{
"cpes": [
"cpe:2.3:h:rockwellautomation:controllogix_5580:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "controllogix_5580",
"vendor": "rockwellautomation",
"versions": [
{
"status": "affected",
"version": "34.011"
}
]
},
{
"cpes": [
"cpe:2.3:h:rockwellautomation:guardlogix_5580:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "guardlogix_5580",
"vendor": "rockwellautomation",
"versions": [
{
"status": "affected",
"version": "34.011"
}
]
},
{
"cpes": [
"cpe:2.3:a:rockwellautomation:1756_en4:0:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "1756_en4",
"vendor": "rockwellautomation",
"versions": [
{
"status": "affected",
"version": "4.001"
}
]
},
{
"cpes": [
"cpe:2.3:a:rockwellautomation:compact_logix_5480:34.011:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "compact_logix_5480",
"vendor": "rockwellautomation",
"versions": [
{
"status": "affected",
"version": "34.011"
}
]
},
{
"cpes": [
"cpe:2.3:a:rockwellautomation:compact_guardlogix_5480:34.011:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "compact_guardlogix_5480",
"vendor": "rockwellautomation",
"versions": [
{
"status": "affected",
"version": "34.011"
}
]
},
{
"cpes": [
"cpe:2.3:h:rockwellautomation:compactlogix:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "compactlogix",
"vendor": "rockwellautomation",
"versions": [
{
"status": "affected",
"version": "5480"
}
]
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:rockwellautomation:controllogix_5580_firmware:34.011:*:*:*:*:*:*:*",
"matchCriteriaId": "02F74A5B-BE74-4F8B-B8D3-D1D48A6C5CA0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:rockwellautomation:controllogix_5580:-:*:*:*:*:*:*:*",
"matchCriteriaId": "51BB883B-B863-4D57-B1C0-FC7B3EBD1EA0",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:rockwellautomation:guardlogix_5580_firmware:34.011:*:*:*:*:*:*:*",
"matchCriteriaId": "D8B88DDE-9002-4EE8-BAA8-73330CB0BE50",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:rockwellautomation:guardlogix_5580:-:*:*:*:*:*:*:*",
"matchCriteriaId": "006B7683-9FDF-4748-BA28-2EA22613E092",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:rockwellautomation:1756-en4_firmware:4.001:*:*:*:*:*:*:*",
"matchCriteriaId": "3B050175-3923-4B1E-AE98-53AF028EE8AA",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:rockwellautomation:1756-en4:-:*:*:*:*:*:*:*",
"matchCriteriaId": "6935642C-4CBF-4B4F-A509-561B3E39A66B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:rockwellautomation:compactlogix_5380_firmware:34.011:*:*:*:*:*:*:*",
"matchCriteriaId": "EC388DFC-DA67-44B6-AE97-731B33F38992",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:rockwellautomation:compactlogix_5380:-:*:*:*:*:*:*:*",
"matchCriteriaId": "EDD040ED-B44C-47D0-B4D4-729C378C4F68",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:rockwellautomation:compact_guardlogix_5380_firmware:34.011:*:*:*:*:*:*:*",
"matchCriteriaId": "01EB5C9E-A10F-4D53-AF3D-38055F966BD6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:rockwellautomation:compact_guardlogix_5380:-:*:*:*:*:*:*:*",
"matchCriteriaId": "62414E65-73C7-4172-B7BF-F40A66AFBB90",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:rockwellautomation:compactlogix_5480_firmware:34.011:*:*:*:*:*:*:*",
"matchCriteriaId": "A913AF0F-DA08-4FE9-9E94-AA1D6227981B",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:rockwellautomation:compactlogix_5480:-:*:*:*:*:*:*:*",
"matchCriteriaId": "80F4F5BE-07DF-402A-BF98-34FBA6A11968",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Rockwell Automation was made aware of a vulnerability that causes all affected controllers on the same network to result in a major nonrecoverable fault(MNRF/Assert). This vulnerability could be exploited by sending abnormal packets to the mDNS port.\u00a0If exploited, the availability of the device would be compromised."
},
{
"lang": "es",
"value": "Rockwell Automation fue informado de una vulnerabilidad que hace que todos los controladores afectados en la misma red produzcan una falla importante no recuperable (MNRF/Assert). Esta vulnerabilidad podr\u00eda explotarse enviando paquetes anormales al puerto mDNS. Si se explota, la disponibilidad del dispositivo se ver\u00eda comprometida."
}
],
"id": "CVE-2024-5659",
"lastModified": "2026-06-17T08:16:22.800",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
],
"cvssMetricV40": [
{
"cvssData": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "ADJACENT",
"availabilityRequirement": "NOT_DEFINED",
"baseScore": 8.3,
"baseSeverity": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"exploitMaturity": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"source": "PSIRT@rockwellautomation.com",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2024-5659",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-06-15T19:57:53.882617Z",
"version": "2.0.3"
}
}
]
},
"published": "2024-06-14T17:15:51.600",
"references": [
{
"source": "PSIRT@rockwellautomation.com",
"tags": [
"Vendor Advisory"
],
"url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1673.html"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1673.html"
}
],
"sourceIdentifier": "PSIRT@rockwellautomation.com",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-670"
}
],
"source": "PSIRT@rockwellautomation.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-670"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
},
"redhat_vex": {
"current_release_date": "2025-05-28T20:23:16+00:00",
"cve": "CVE-2024-5659",
"id": "CVE-2024-5659",
"initial_release_date": "2024-06-13T13:00:00+00:00",
"product_status:known_not_affected": "1",
"source": "Red Hat CSAF VEX",
"status": "final",
"title": "Rockwell Automation Multicast Request Causes major nonrecoverable fault on Select Controllers",
"url": "https://security.access.redhat.com/data/csaf/v2/vex/2024/cve-2024-5659.json",
"version": "3"
},
"vulnrichment": {
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-01T21:18:06.865Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1673.html"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:h:rockwellautomation:controllogix_5580:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "controllogix_5580",
"vendor": "rockwellautomation",
"versions": [
{
"status": "affected",
"version": "34.011"
}
]
},
{
"cpes": [
"cpe:2.3:h:rockwellautomation:guardlogix_5580:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "guardlogix_5580",
"vendor": "rockwellautomation",
"versions": [
{
"status": "affected",
"version": "34.011"
}
]
},
{
"cpes": [
"cpe:2.3:a:rockwellautomation:1756_en4:0:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "1756_en4",
"vendor": "rockwellautomation",
"versions": [
{
"status": "affected",
"version": "4.001"
}
]
},
{
"cpes": [
"cpe:2.3:a:rockwellautomation:compact_logix_5480:34.011:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "compact_logix_5480",
"vendor": "rockwellautomation",
"versions": [
{
"status": "affected",
"version": "34.011"
}
]
},
{
"cpes": [
"cpe:2.3:a:rockwellautomation:compact_guardlogix_5480:34.011:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "compact_guardlogix_5480",
"vendor": "rockwellautomation",
"versions": [
{
"status": "affected",
"version": "34.011"
}
]
},
{
"cpes": [
"cpe:2.3:h:rockwellautomation:compactlogix:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "compactlogix",
"vendor": "rockwellautomation",
"versions": [
{
"status": "affected",
"version": "5480"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-5659",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-06-15T19:57:53.882617Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-15T20:01:15.688Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "ControlLogix\u00ae 5580",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "34.011"
}
]
},
{
"defaultStatus": "unaffected",
"product": "GuardLogix 5580",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "34.011"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN4",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "4.001"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CompactLogix 5380",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "34.011"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Compact GuardLogix 5380",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "34.011"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CompactLogix 5480",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "34.011"
}
]
}
],
"datePublic": "2024-06-13T13:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eRockwell Automation was made aware of a vulnerability that causes all affected controllers on the same network to result in a major nonrecoverable fault(MNRF/Assert). This vulnerability could be exploited by sending \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\"\u003e\u003c/a\u003e\u003ca target=\"_blank\" rel=\"nofollow\"\u003e\u003c/a\u003e\u003ca target=\"_blank\" rel=\"nofollow\"\u003e\u003c/a\u003e\u003ca target=\"_blank\" rel=\"nofollow\"\u003eabnormal packets to the \u003c/a\u003e\u003ca target=\"_blank\" rel=\"nofollow\"\u003emDNS port.\u0026nbsp;\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eIf exploited, the availability of the device would be compromised.\u003c/span\u003e\n\n"
}
],
"value": "Rockwell Automation was made aware of a vulnerability that causes all affected controllers on the same network to result in a major nonrecoverable fault(MNRF/Assert). This vulnerability could be exploited by sending abnormal packets to the mDNS port.\u00a0If exploited, the availability of the device would be compromised."
}
],
"impacts": [
{
"capecId": "CAPEC-624",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-624 Hardware Fault Injection"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "ADJACENT",
"baseScore": 8.3,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-670",
"description": "CWE-670 Always-Incorrect Control Flow Implementation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-14T16:42:20.699Z",
"orgId": "b73dd486-f505-4403-b634-40b078b177f0",
"shortName": "Rockwell"
},
"references": [
{
"url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1673.html"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003eAffected Product\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003eFirst Known in firmware revision\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003eCorrected in firmware revision\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003eControlLogix\u00ae 5580\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003eV34.011\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003eV34.014, V35.013, V36.011 and later\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003eGuardLogix 5580\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003eV34.011\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003eV34.014, V35.013, V36.011 and later \u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003e1756-EN4\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003eV4.001\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003eV6.001 and later\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003eCompactLogix 5380\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003eV34.011\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003eV34.014, V35.013, V36.011 and later \u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\"\u003e\u003c/a\u003e\u003ca target=\"_blank\" rel=\"nofollow\"\u003eCompact GuardLogix \u003c/a\u003e\u003cb\u003e\u0026nbsp;\u003c/b\u003e5380\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003eV34.011\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003eV34.014, V35.013, V36.011 and later \u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003eCompactLogix 5480\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003eV34.011\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003eV34.014, V35.013, V36.011 and later\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003c/tbody\u003e\u003c/table\u003e\u003cbr\u003e\n\n\u003cp\u003e\u003cb\u003eMitigations and Workarounds\u003c/b\u003e\u003c/p\u003e\u003cp\u003eUsers using the affected software and who are not able to upgrade to one of the corrected versions are encouraged to apply the risk mitigations, where possible.\u003c/p\u003e\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; Users who do not use \u003ca target=\"_blank\" rel=\"nofollow\"\u003e\u003c/a\u003e\u003ca target=\"_blank\" rel=\"nofollow\"\u003eAutomatic Policy Deployment (APD)\u003c/a\u003e\u0026nbsp;should block \u003ca target=\"_blank\" rel=\"nofollow\"\u003e\u003c/a\u003e\u003ca target=\"_blank\" rel=\"nofollow\"\u003e\u003c/a\u003e\u003ca target=\"_blank\" rel=\"nofollow\"\u003e\u003c/a\u003e\u003ca target=\"_blank\" rel=\"nofollow\"\u003emDNS port, 5353\u003c/a\u003e\u0026nbsp;to help prevent communication.\u003c/p\u003e\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; Enable CIP \u003ca target=\"_blank\" rel=\"nofollow\"\u003e\u003c/a\u003e\u003ca target=\"_blank\" rel=\"nofollow\"\u003e\u003c/a\u003e\u003ca target=\"_blank\" rel=\"nofollow\"\u003e\u003c/a\u003e\u003ca target=\"_blank\" rel=\"nofollow\"\u003e\u003c/a\u003e\u003ca target=\"_blank\" rel=\"nofollow\"\u003eSecurity. \u003c/a\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://literature.rockwellautomation.com/idc/groups/literature/documents/at/secure-at001_-en-p.pdf\"\u003eCIP Security with Rockwell Automation Products Application Technique\u003c/a\u003e\u003c/p\u003e\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight\"\u003eSecurity Best Practices\u003c/a\u003e\u003c/p\u003e\n\n\u003cbr\u003e"
}
],
"value": "Affected Product\n\nFirst Known in firmware revision\n\nCorrected in firmware revision\n\nControlLogix\u00ae 5580\n\nV34.011\n\nV34.014, V35.013, V36.011 and later\n\nGuardLogix 5580\n\nV34.011\n\nV34.014, V35.013, V36.011 and later \n\n1756-EN4\n\nV4.001\n\nV6.001 and later\n\nCompactLogix 5380\n\nV34.011\n\nV34.014, V35.013, V36.011 and later \n\nCompact GuardLogix \u00a05380\n\nV34.011\n\nV34.014, V35.013, V36.011 and later \n\nCompactLogix 5480\n\nV34.011\n\nV34.014, V35.013, V36.011 and later\n\n\n\n\nMitigations and Workarounds\n\nUsers using the affected software and who are not able to upgrade to one of the corrected versions are encouraged to apply the risk mitigations, where possible.\n\n\u00b7 \u00a0 \u00a0 \u00a0 Users who do not use CIP Security with Rockwell Automation Products Application Technique https://literature.rockwellautomation.com/idc/groups/literature/documents/at/secure-at001_-en-p.pdf \n\n\u00b7 \u00a0 \u00a0 \u00a0 Security Best Practices https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Rockwell Automation Multicast Request Causes major nonrecoverable fault on Select Controllers",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
"assignerShortName": "Rockwell",
"cveId": "CVE-2024-5659",
"datePublished": "2024-06-14T16:42:20.699Z",
"dateReserved": "2024-06-05T16:47:18.275Z",
"dateUpdated": "2024-08-01T21:18:06.865Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Solutions
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.