CVE-2024-48010 (GCVE-0-2024-48010)
Vulnerability from cvelistv5 – Published: 2024-11-08 03:01 – Updated: 2024-11-08 15:56
VLAI
EPSS
VEX
Summary
Dell PowerProtect DD, versions prior to 8.1.0.0, 7.13.1.10, 7.10.1.40, and 7.7.5.50, contains an access control vulnerability. A remote high privileged attacker could potentially exploit this vulnerability, leading to escalation of privilege on the application.
Severity
6.5 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-11-08 14:39 UTC
CWE
- CWE-284 - Improper Access Control
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00024536… | vendor-advisory |
Impacted products
2 products
| Vendor | Product | Version | CPE status | |
|---|---|---|---|---|
| Dell | PowerProtect DD |
Affected:
7.7.1 , ≤ 8.0.0.0
(semver)
Affected: N/A , < 7.13.1.10 (semver) Affected: N/A , < 7.10.1.40 (semver) Affected: N/A , < 7.7.5.50 (semver) |
guessed | |
| dell | powerprotect_data_domain_management_center |
Affected:
7.13 , < 7.13.1.10
(semver)
Affected: 7.10 , < 7.10.1.40 (semver) Affected: 7.7 , < 7.7.5.50 (semver) Affected: 7.7.1 , ≤ 8.0.0.0 (semver) cpe:2.3:o:dell:emc_data_domain_os:*:*:*:*:*:*:*:* cpe:2.3:a:dell:apex_protection_storage:*:*:*:*:*:*:*:* cpe:2.3:a:dell:powerprotect_data_domain:-:*:*:*:virtual:*:*:* cpe:2.3:a:dell:powerprotect_data_domain:*:*:*:*:*:*:*:* cpe:2.3:a:dell:powerprotect_data_domain_management_center:*:*:*:*:*:*:*:* |
Date Public
2024-11-06 06:30
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:dell:emc_data_domain_os:*:*:*:*:*:*:*:*",
"cpe:2.3:a:dell:apex_protection_storage:*:*:*:*:*:*:*:*",
"cpe:2.3:a:dell:powerprotect_data_domain:-:*:*:*:virtual:*:*:*",
"cpe:2.3:a:dell:powerprotect_data_domain:*:*:*:*:*:*:*:*",
"cpe:2.3:a:dell:powerprotect_data_domain_management_center:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "powerprotect_data_domain_management_center",
"vendor": "dell",
"versions": [
{
"lessThan": "7.13.1.10",
"status": "affected",
"version": "7.13",
"versionType": "semver"
},
{
"lessThan": "7.10.1.40",
"status": "affected",
"version": "7.10",
"versionType": "semver"
},
{
"lessThan": "7.7.5.50",
"status": "affected",
"version": "7.7",
"versionType": "semver"
},
{
"lessThanOrEqual": "8.0.0.0",
"status": "affected",
"version": "7.7.1",
"versionType": "semver"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-48010",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-08T14:39:27.260279Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-08T15:56:27.836Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerProtect DD",
"vendor": "Dell",
"versions": [
{
"lessThanOrEqual": "8.0.0.0",
"status": "affected",
"version": "7.7.1",
"versionType": "semver"
},
{
"lessThan": "7.13.1.10",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "7.10.1.40",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "7.7.5.50",
"status": "affected",
"version": "N/A",
"versionType": "semver"
}
]
}
],
"datePublic": "2024-11-06T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerProtect DD, versions prior to 8.1.0.0, 7.13.1.10, 7.10.1.40, and 7.7.5.50, contains an access control vulnerability. A remote high privileged attacker could potentially exploit this vulnerability, leading to escalation of privilege on the application."
}
],
"value": "Dell PowerProtect DD, versions prior to 8.1.0.0, 7.13.1.10, 7.10.1.40, and 7.7.5.50, contains an access control vulnerability. A remote high privileged attacker could potentially exploit this vulnerability, leading to escalation of privilege on the application."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284: Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-11-08T03:01:01.903Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000245360/dsa-2024-424-security-update-for-dell-pdsa-2024-424-security-update-for-dell-powerprotect-dd-vulnerabilityowerprotect-dd-vulnerability"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2024-48010",
"datePublished": "2024-11-08T03:01:01.903Z",
"dateReserved": "2024-10-08T05:40:53.868Z",
"dateUpdated": "2024-11-08T15:56:27.836Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2024-48010",
"date": "2026-09-20",
"epss": "0.00378",
"percentile": "0.31722"
},
"nvd": {
"cve": {
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "PowerProtect DD",
"vendor": "Dell",
"versions": [
{
"lessThanOrEqual": "8.0.0.0",
"status": "affected",
"version": "7.7.1",
"versionType": "semver"
},
{
"lessThan": "7.13.1.10",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "7.10.1.40",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "7.7.5.50",
"status": "affected",
"version": "N/A",
"versionType": "semver"
}
]
}
],
"source": "security_alert@emc.com"
},
{
"affectedData": [
{
"cpes": [
"cpe:2.3:o:dell:emc_data_domain_os:*:*:*:*:*:*:*:*",
"cpe:2.3:a:dell:apex_protection_storage:*:*:*:*:*:*:*:*",
"cpe:2.3:a:dell:powerprotect_data_domain:-:*:*:*:virtual:*:*:*",
"cpe:2.3:a:dell:powerprotect_data_domain:*:*:*:*:*:*:*:*",
"cpe:2.3:a:dell:powerprotect_data_domain_management_center:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "powerprotect_data_domain_management_center",
"vendor": "dell",
"versions": [
{
"lessThan": "7.13.1.10",
"status": "affected",
"version": "7.13",
"versionType": "semver"
},
{
"lessThan": "7.10.1.40",
"status": "affected",
"version": "7.10",
"versionType": "semver"
},
{
"lessThan": "7.7.5.50",
"status": "affected",
"version": "7.7",
"versionType": "semver"
},
{
"lessThanOrEqual": "8.0.0.0",
"status": "affected",
"version": "7.7.1",
"versionType": "semver"
}
]
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:dell:data_domain_operating_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F67B432D-426C-4155-B365-A08CE8AD29AC",
"versionEndExcluding": "7.7.5.50",
"versionStartIncluding": "7.7.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:dell:data_domain_operating_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "581408C7-9067-41F9-AA9C-E58ECA0EE006",
"versionEndExcluding": "7.10.1.40",
"versionStartIncluding": "7.10.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:dell:data_domain_operating_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D65074E3-083E-4010-8E66-2A256155311A",
"versionEndExcluding": "7.13.1.10",
"versionStartIncluding": "7.13.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:dell:data_domain_operating_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "45B0DE69-722F-4180-B4A7-24D002B3035C",
"versionEndExcluding": "8.1.0.0",
"versionStartIncluding": "8.0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Dell PowerProtect DD, versions prior to 8.1.0.0, 7.13.1.10, 7.10.1.40, and 7.7.5.50, contains an access control vulnerability. A remote high privileged attacker could potentially exploit this vulnerability, leading to escalation of privilege on the application."
},
{
"lang": "es",
"value": "Dell PowerProtect DD, versiones anteriores a 8.1.0.0, 7.13.1.10, 7.10.1.40 y 7.7.5.50, contiene una vulnerabilidad de control de acceso. Un atacante remoto con privilegios elevados podr\u00eda aprovechar esta vulnerabilidad, lo que provocar\u00eda una escalada de privilegios en la aplicaci\u00f3n."
}
],
"id": "CVE-2024-48010",
"lastModified": "2026-06-17T07:58:05.823",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.2,
"impactScore": 5.2,
"source": "security_alert@emc.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.2,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2024-48010",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-08T14:39:27.260279Z",
"version": "2.0.3"
}
}
]
},
"published": "2024-11-08T03:15:03.933",
"references": [
{
"source": "security_alert@emc.com",
"tags": [
"Vendor Advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000245360/dsa-2024-424-security-update-for-dell-pdsa-2024-424-security-update-for-dell-powerprotect-dd-vulnerabilityowerprotect-dd-vulnerability"
}
],
"sourceIdentifier": "security_alert@emc.com",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-284"
}
],
"source": "security_alert@emc.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
},
"redhat_vex": {
"current_release_date": "2025-05-28T19:19:50+00:00",
"cve": "CVE-2024-48010",
"id": "CVE-2024-48010",
"initial_release_date": "2024-11-06T06:30:00+00:00",
"product_status:known_not_affected": "1",
"source": "Red Hat CSAF VEX",
"status": "final",
"title": "CVE-2024-48010",
"url": "https://security.access.redhat.com/data/csaf/v2/vex/2024/cve-2024-48010.json",
"version": "3"
},
"vulnrichment": {
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:dell:emc_data_domain_os:*:*:*:*:*:*:*:*",
"cpe:2.3:a:dell:apex_protection_storage:*:*:*:*:*:*:*:*",
"cpe:2.3:a:dell:powerprotect_data_domain:-:*:*:*:virtual:*:*:*",
"cpe:2.3:a:dell:powerprotect_data_domain:*:*:*:*:*:*:*:*",
"cpe:2.3:a:dell:powerprotect_data_domain_management_center:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "powerprotect_data_domain_management_center",
"vendor": "dell",
"versions": [
{
"lessThan": "7.13.1.10",
"status": "affected",
"version": "7.13",
"versionType": "semver"
},
{
"lessThan": "7.10.1.40",
"status": "affected",
"version": "7.10",
"versionType": "semver"
},
{
"lessThan": "7.7.5.50",
"status": "affected",
"version": "7.7",
"versionType": "semver"
},
{
"lessThanOrEqual": "8.0.0.0",
"status": "affected",
"version": "7.7.1",
"versionType": "semver"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-48010",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-08T14:39:27.260279Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-08T15:56:15.389Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerProtect DD",
"vendor": "Dell",
"versions": [
{
"lessThanOrEqual": "8.0.0.0",
"status": "affected",
"version": "7.7.1",
"versionType": "semver"
},
{
"lessThan": "7.13.1.10",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "7.10.1.40",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "7.7.5.50",
"status": "affected",
"version": "N/A",
"versionType": "semver"
}
]
}
],
"datePublic": "2024-11-06T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerProtect DD, versions prior to 8.1.0.0, 7.13.1.10, 7.10.1.40, and 7.7.5.50, contains an access control vulnerability. A remote high privileged attacker could potentially exploit this vulnerability, leading to escalation of privilege on the application."
}
],
"value": "Dell PowerProtect DD, versions prior to 8.1.0.0, 7.13.1.10, 7.10.1.40, and 7.7.5.50, contains an access control vulnerability. A remote high privileged attacker could potentially exploit this vulnerability, leading to escalation of privilege on the application."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284: Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-11-08T03:01:01.903Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000245360/dsa-2024-424-security-update-for-dell-pdsa-2024-424-security-update-for-dell-powerprotect-dd-vulnerabilityowerprotect-dd-vulnerability"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2024-48010",
"datePublished": "2024-11-08T03:01:01.903Z",
"dateReserved": "2024-10-08T05:40:53.868Z",
"dateUpdated": "2024-11-08T15:56:27.836Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
The MITRE ATT&CK techniques below are AI-generated suggestions, inferred from the description of the
vulnerability by the CIRCL/vulnerability-attack-technique-classification-roberta-base
model, served locally by ML-Gateway.
They have not been verified by an analyst and are provided for guidance only.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Loading…
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.
Loading…