CVE-2024-43653 (GCVE-0-2024-43653)
Vulnerability from cvelistv5 – Published: 2025-01-09 07:56 – Updated: 2025-03-11 13:07| URL | Tags |
|---|---|
| https://csirt.divd.nl/DIVD-2024-00035/ | third-party-advisory |
| https://csirt.divd.nl/CVE-2024-43653/ | third-party-advisory |
| https://iocharger.com | product |
| Vendor | Product | Version | CPE status | |
|---|---|---|---|---|
| Iocharger | Iocharger firmware for AC models |
Affected:
0 , < 24120701
(custom)
|
guessed |
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-43653",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-09T14:39:24.235683Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-01-09T14:40:21.083Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Iocharger firmware for AC models",
"vendor": "Iocharger",
"versions": [
{
"lessThan": "24120701",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Wilco van Beijnum"
},
{
"lang": "en",
"type": "analyst",
"value": "Harm van den Brink (DIVD)"
},
{
"lang": "en",
"type": "analyst",
"value": "Frank Breedijk (DIVD)"
}
],
"datePublic": "2025-01-09T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027) vulnerability\u0026nbsp; allows OS Command Injection as root\u003cbr\u003eThis issue affects Iocharger firmware for AC model chargers before version 24120701.\u003cbr\u003e\u003cbr\u003eLikelihood: Moderate \u2013 The \u0026lt;redacted\u0026gt; binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the \u0026lt;redacted\u0026gt; binary, or convince a user with such access to execute a crafted HTTP request.\u003cbr\u003e\u003cbr\u003eImpact: Critical \u2013 The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete\u003cbr\u003efiles and services.\u003cbr\u003e\u003cbr\u003eCVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).\u003cbr\u003e"
}
],
"value": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027) vulnerability\u00a0 allows OS Command Injection as root\nThis issue affects Iocharger firmware for AC model chargers before version 24120701.\n\nLikelihood: Moderate \u2013 The \u003credacted\u003e binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the \u003credacted\u003e binary, or convince a user with such access to execute a crafted HTTP request.\n\nImpact: Critical \u2013 The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete\nfiles and services.\n\nCVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y)."
}
],
"impacts": [
{
"capecId": "CAPEC-88",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-88 OS Command Injection"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "YES",
"Recovery": "NOT_DEFINED",
"Safety": "PRESENT",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "LOW",
"subIntegrityImpact": "LOW",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:H/S:P/AU:Y",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-250",
"description": "CWE-250: Execution with Unnecessary Privileges",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"description": "OWASP-A03: Injection",
"lang": "en"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-11T13:07:21.123Z",
"orgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
"shortName": "DIVD"
},
"references": [
{
"tags": [
"third-party-advisory"
],
"url": "https://csirt.divd.nl/DIVD-2024-00035/"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://csirt.divd.nl/CVE-2024-43653/"
},
{
"tags": [
"product"
],
"url": "https://iocharger.com"
}
],
"source": {
"advisory": "DIVD-2024-00035",
"discovery": "EXTERNAL"
},
"title": "Authenticated command injection in the \u003credacted\u003e action leads to full remote code execution as root on the charging station",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
"assignerShortName": "DIVD",
"cveId": "CVE-2024-43653",
"datePublished": "2025-01-09T07:56:46.647Z",
"dateReserved": "2024-08-14T09:27:41.767Z",
"dateUpdated": "2025-03-11T13:07:21.123Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2024-43653",
"date": "2026-11-15",
"epss": "0.02158",
"percentile": "0.82483"
},
"nvd": {
"cve": {
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "Iocharger firmware for AC models",
"vendor": "Iocharger",
"versions": [
{
"lessThan": "24120701",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"source": "csirt@divd.nl"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027) vulnerability\u00a0 allows OS Command Injection as root\nThis issue affects Iocharger firmware for AC model chargers before version 24120701.\n\nLikelihood: Moderate \u2013 The \u003credacted\u003e binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the \u003credacted\u003e binary, or convince a user with such access to execute a crafted HTTP request.\n\nImpact: Critical \u2013 The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete\nfiles and services.\n\nCVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y)."
},
{
"lang": "es",
"value": "Vulnerabilidad de neutralizaci\u00f3n incorrecta de elementos especiales utilizados en un comando (\u0027Inyecci\u00f3n de comando\u0027) permite la inyecci\u00f3n de comandos del sistema operativo como root Este problema afecta al firmware de Iocharger para cargadores modelo AC anteriores a la versi\u00f3n 24120701. Probabilidad: moderada: el binario no parece ser utilizado por la interfaz web, por lo que podr\u00eda ser m\u00e1s dif\u00edcil de encontrar. Sin embargo, parece ser en gran medida el mismo binario que utiliza la estaci\u00f3n de carga Pedestal de Iocharger. El atacante tambi\u00e9n necesitar\u00e1 una cuenta (con privilegios bajos) para obtener acceso al binario o convencer a un usuario con dicho acceso para que ejecute una solicitud HTTP manipulada. Impacto: cr\u00edtico: el atacante tiene control total sobre la estaci\u00f3n de carga como usuario superusuario y puede agregar, modificar y eliminar archivos y servicios de forma arbitraria. Aclaraci\u00f3n de CVSS: cualquier interfaz de red que sirva a la interfaz de usuario web es vulnerable (AV:N) y no hay medidas de seguridad adicionales para eludir (AC:L), ni el ataque requiere condiciones previas existentes (AT:N). El ataque est\u00e1 autenticado, pero el nivel de autenticaci\u00f3n no importa (PR:L), ni se requiere interacci\u00f3n del usuario (UI:N). El ataque lleva a una vulnerabilidad total (VC:H/VI:H/VA:H), y los dispositivos afectados pueden usarse para ingresar a redes que potencialmente no deber\u00edan ser accesibles (SC:L/SI:L/SA:H). Debido a que se trata de un cargador de veh\u00edculos el\u00e9ctricos que gestiona una cantidad significativa de energ\u00eda, existe un posible impacto en la seguridad (S:P). Este ataque puede automatizarse (AU:Y)."
}
],
"id": "CVE-2024-43653",
"lastModified": "2026-06-17T07:51:29.990",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
],
"cvssMetricV40": [
{
"cvssData": {
"Automatable": "YES",
"Recovery": "NOT_DEFINED",
"Safety": "PRESENT",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"availabilityRequirement": "NOT_DEFINED",
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"confidentialityRequirement": "NOT_DEFINED",
"exploitMaturity": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "LOW",
"subIntegrityImpact": "LOW",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:P/AU:Y/R:X/V:X/RE:X/U:X",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"source": "csirt@divd.nl",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2024-43653",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-09T14:39:24.235683Z",
"version": "2.0.3"
}
}
]
},
"published": "2025-01-09T08:15:27.950",
"references": [
{
"source": "csirt@divd.nl",
"url": "https://csirt.divd.nl/CVE-2024-43653/"
},
{
"source": "csirt@divd.nl",
"url": "https://csirt.divd.nl/DIVD-2024-00035/"
},
{
"source": "csirt@divd.nl",
"url": "https://iocharger.com"
}
],
"sourceIdentifier": "csirt@divd.nl",
"vulnStatus": "Deferred",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-78"
},
{
"lang": "en",
"value": "CWE-250"
}
],
"source": "csirt@divd.nl",
"type": "Secondary"
}
]
}
},
"redhat_vex": {
"current_release_date": "2025-05-28T22:05:25+00:00",
"cve": "CVE-2024-43653",
"id": "CVE-2024-43653",
"initial_release_date": "2024-01-01T00:00:00+00:00",
"product_status:known_not_affected": "1",
"source": "Red Hat CSAF VEX",
"status": "final",
"title": "Authenticated command injection in the \u003credacted\u003e action leads to full remote code execution as root on the charging station",
"url": "https://security.access.redhat.com/data/csaf/v2/vex/2024/cve-2024-43653.json",
"version": "3"
},
"vulnrichment": {
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-43653",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-09T14:39:24.235683Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-01-09T14:39:55.875Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Iocharger firmware for AC models",
"vendor": "Iocharger",
"versions": [
{
"lessThan": "24120701",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Wilco van Beijnum"
},
{
"lang": "en",
"type": "analyst",
"value": "Harm van den Brink (DIVD)"
},
{
"lang": "en",
"type": "analyst",
"value": "Frank Breedijk (DIVD)"
}
],
"datePublic": "2025-01-09T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027) vulnerability\u0026nbsp; allows OS Command Injection as root\u003cbr\u003eThis issue affects Iocharger firmware for AC model chargers before version 24120701.\u003cbr\u003e\u003cbr\u003eLikelihood: Moderate \u2013 The \u0026lt;redacted\u0026gt; binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the \u0026lt;redacted\u0026gt; binary, or convince a user with such access to execute a crafted HTTP request.\u003cbr\u003e\u003cbr\u003eImpact: Critical \u2013 The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete\u003cbr\u003efiles and services.\u003cbr\u003e\u003cbr\u003eCVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).\u003cbr\u003e"
}
],
"value": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027) vulnerability\u00a0 allows OS Command Injection as root\nThis issue affects Iocharger firmware for AC model chargers before version 24120701.\n\nLikelihood: Moderate \u2013 The \u003credacted\u003e binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the \u003credacted\u003e binary, or convince a user with such access to execute a crafted HTTP request.\n\nImpact: Critical \u2013 The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete\nfiles and services.\n\nCVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y)."
}
],
"impacts": [
{
"capecId": "CAPEC-88",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-88 OS Command Injection"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "YES",
"Recovery": "NOT_DEFINED",
"Safety": "PRESENT",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "LOW",
"subIntegrityImpact": "LOW",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:H/S:P/AU:Y",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-250",
"description": "CWE-250: Execution with Unnecessary Privileges",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"description": "OWASP-A03: Injection",
"lang": "en"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-11T13:07:21.123Z",
"orgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
"shortName": "DIVD"
},
"references": [
{
"tags": [
"third-party-advisory"
],
"url": "https://csirt.divd.nl/DIVD-2024-00035/"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://csirt.divd.nl/CVE-2024-43653/"
},
{
"tags": [
"product"
],
"url": "https://iocharger.com"
}
],
"source": {
"advisory": "DIVD-2024-00035",
"discovery": "EXTERNAL"
},
"title": "Authenticated command injection in the \u003credacted\u003e action leads to full remote code execution as root on the charging station",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "b87402ff-ae37-4194-9dae-31abdbd6f217",
"assignerShortName": "DIVD",
"cveId": "CVE-2024-43653",
"datePublished": "2025-01-09T07:56:46.647Z",
"dateReserved": "2024-08-14T09:27:41.767Z",
"dateUpdated": "2025-03-11T13:07:21.123Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.