CVE-2024-39815 (GCVE-0-2024-39815)

Vulnerability from cvelistv5 – Published: 2024-08-08 19:33 – Updated: 2024-08-21 20:04
VLAI
Title
Vonets WiFi Bridges Improper Check or Handling of Exceptional Conditions
Summary
Improper check or handling of exceptional conditions vulnerability affecting Vonets industrial wifi bridge relays and wifi bridge repeaters, software versions 3.3.23.6.9 and prior, enable an unauthenticated remote attacker to cause a denial of service. A specially-crafted HTTP request to pre-authentication resources can crash the service.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-08-09 14:41 UTC
CWE
Assigner
icscert CNA under the icscert root
CNA scorecard B 75/100 over 337 records in the last 180 days details
Impacted products
Vendor Product Version CPE status
Vonets VAR1200-H Affected: 0 , ≤ 3.3.23.6.9 (custom)
guessed Create a notification for this product.
Vonets VAR1200-L Affected: 0 , ≤ 3.3.23.6.9 (custom)
guessed Create a notification for this product.
Vonets VAR600-H Affected: 0 , ≤ 3.3.23.6.9 (custom)
guessed Create a notification for this product.
Vonets VAP11AC Affected: 0 , ≤ 3.3.23.6.9 (custom)
guessed Create a notification for this product.
Vonets VAP11G-500S Affected: 0 , ≤ 3.3.23.6.9 (custom)
guessed Create a notification for this product.
Vonets VBG1200 Affected: 0 , ≤ 3.3.23.6.9 (custom)
guessed Create a notification for this product.
Vonets VAP11S-5G Affected: 0 , ≤ 3.3.23.6.9 (custom)
guessed Create a notification for this product.
Vonets VAP11S Affected: 0 , ≤ 3.3.23.6.9 (custom)
guessed Create a notification for this product.
Vonets VAR11N-300 Affected: 0 , ≤ 3.3.23.6.9 (custom)
guessed Create a notification for this product.
Vonets VAP11G-300 Affected: 0 , ≤ 3.3.23.6.9 (custom)
guessed Create a notification for this product.
Vonets VAP11N-300 Affected: 0 , ≤ 3.3.23.6.9 (custom)
guessed Create a notification for this product.
Vonets VAP11G Affected: 0 , ≤ 3.3.23.6.9 (custom)
guessed Create a notification for this product.
Vonets VAP11G-500 Affected: 0 , ≤ 3.3.23.6.9 (custom)
guessed Create a notification for this product.
Vonets VGA-1000 Affected: 0 , ≤ 3.3.23.6.9 (custom)
guessed Create a notification for this product.
vonets var1200-h_firmware Affected: 0 , ≤ 3.3.23.6.9 (custom)
    cpe:2.3:o:vonets:var1200-h_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
vonets var1200-l_firmware Affected: 0 , ≤ 3.3.23.6.9 (custom)
    cpe:2.3:o:vonets:var1200-l_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
vonets var600-h_firmware Affected: 0 , ≤ 3.3.23.6.9 (custom)
    cpe:2.3:o:vonets:var600-h_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
vonets vap11ac_firmware Affected: 0 , ≤ 3.3.23.6.9 (custom)
    cpe:2.3:o:vonets:vap11ac_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
vonets vap11g-500s_firmware Affected: 0 , ≤ 3.3.23.6.9 (custom)
    cpe:2.3:o:vonets:vap11g-500s_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
vonets vbg1200_firmware Affected: 0 , ≤ 3.3.23.6.9 (custom)
    cpe:2.3:o:vonets:vbg1200_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
vonets vap11s-5g_firmware Affected: 0 , ≤ 3.3.23.6.9 (custom)
    cpe:2.3:o:vonets:vap11s-5g_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
vonets vap11s_firmware Affected: 0 , ≤ 3.3.23.6.9 (custom)
    cpe:2.3:o:vonets:vap11s_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
vonets var11n-300_firmware Affected: 0 , ≤ 3.3.23.6.9 (custom)
    cpe:2.3:o:vonets:var11n-300_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
vonets vap11n-300_firmware Affected: 0 , ≤ 3.3.23.6.9 (custom)
    cpe:2.3:o:vonets:vap11n-300_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
vonets vap11g_firmware Affected: 0 , ≤ 3.3.23.6.9 (custom)
    cpe:2.3:o:vonets:vap11g_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
vonets vga-1000_firmware Affected: 0 , ≤ 3.3.23.6.9 (custom)
    cpe:2.3:o:vonets:vga-1000_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
vonets vap11g-300_firmware Affected: 0 , ≤ 3.3.23.6.9 (custom)
    cpe:2.3:o:vonets:vap11g-300_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:vonets:var1200-h_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "var1200-h_firmware",
            "vendor": "vonets",
            "versions": [
              {
                "lessThanOrEqual": "3.3.23.6.9",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:vonets:var1200-l_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "var1200-l_firmware",
            "vendor": "vonets",
            "versions": [
              {
                "lessThanOrEqual": "3.3.23.6.9",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:vonets:var600-h_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "var600-h_firmware",
            "vendor": "vonets",
            "versions": [
              {
                "lessThanOrEqual": "3.3.23.6.9",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:vonets:vap11ac_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "vap11ac_firmware",
            "vendor": "vonets",
            "versions": [
              {
                "lessThanOrEqual": "3.3.23.6.9",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:vonets:vap11g-500s_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "vap11g-500s_firmware",
            "vendor": "vonets",
            "versions": [
              {
                "lessThanOrEqual": "3.3.23.6.9",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:vonets:vbg1200_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "vbg1200_firmware",
            "vendor": "vonets",
            "versions": [
              {
                "lessThanOrEqual": "3.3.23.6.9",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:vonets:vap11s-5g_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "vap11s-5g_firmware",
            "vendor": "vonets",
            "versions": [
              {
                "lessThanOrEqual": "3.3.23.6.9",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:vonets:vap11s_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "vap11s_firmware",
            "vendor": "vonets",
            "versions": [
              {
                "lessThanOrEqual": "3.3.23.6.9",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:vonets:var11n-300_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "var11n-300_firmware",
            "vendor": "vonets",
            "versions": [
              {
                "lessThanOrEqual": "3.3.23.6.9",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:vonets:vap11n-300_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "vap11n-300_firmware",
            "vendor": "vonets",
            "versions": [
              {
                "lessThanOrEqual": "3.3.23.6.9",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:vonets:vap11g_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "vap11g_firmware",
            "vendor": "vonets",
            "versions": [
              {
                "lessThanOrEqual": "3.3.23.6.9",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:vonets:vga-1000_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "vga-1000_firmware",
            "vendor": "vonets",
            "versions": [
              {
                "lessThanOrEqual": "3.3.23.6.9",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:vonets:vap11g-300_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "vap11g-300_firmware",
            "vendor": "vonets",
            "versions": [
              {
                "lessThanOrEqual": "3.3.23.6.9",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:vonets:vap11n-300_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "vap11n-300_firmware",
            "vendor": "vonets",
            "versions": [
              {
                "lessThanOrEqual": "3.3.23.6.9",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-39815",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-09T14:41:59.876924Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-21T20:04:38.205Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "VAR1200-H",
          "vendor": "Vonets",
          "versions": [
            {
              "lessThanOrEqual": "3.3.23.6.9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "VAR1200-L",
          "vendor": "Vonets",
          "versions": [
            {
              "lessThanOrEqual": "3.3.23.6.9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "VAR600-H",
          "vendor": "Vonets",
          "versions": [
            {
              "lessThanOrEqual": "3.3.23.6.9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "VAP11AC",
          "vendor": "Vonets",
          "versions": [
            {
              "lessThanOrEqual": "3.3.23.6.9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "VAP11G-500S",
          "vendor": "Vonets",
          "versions": [
            {
              "lessThanOrEqual": "3.3.23.6.9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "VBG1200",
          "vendor": "Vonets",
          "versions": [
            {
              "lessThanOrEqual": "3.3.23.6.9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "VAP11S-5G",
          "vendor": "Vonets",
          "versions": [
            {
              "lessThanOrEqual": "3.3.23.6.9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "VAP11S",
          "vendor": "Vonets",
          "versions": [
            {
              "lessThanOrEqual": "3.3.23.6.9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "VAR11N-300",
          "vendor": "Vonets",
          "versions": [
            {
              "lessThanOrEqual": "3.3.23.6.9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "VAP11G-300",
          "vendor": "Vonets",
          "versions": [
            {
              "lessThanOrEqual": "3.3.23.6.9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "VAP11N-300",
          "vendor": "Vonets",
          "versions": [
            {
              "lessThanOrEqual": "3.3.23.6.9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "VAP11G",
          "vendor": "Vonets",
          "versions": [
            {
              "lessThanOrEqual": "3.3.23.6.9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "VAP11G-500",
          "vendor": "Vonets",
          "versions": [
            {
              "lessThanOrEqual": "3.3.23.6.9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "VBG1200",
          "vendor": "Vonets",
          "versions": [
            {
              "lessThanOrEqual": "3.3.23.6.9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "VAP11AC",
          "vendor": "Vonets",
          "versions": [
            {
              "lessThanOrEqual": "3.3.23.6.9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "VGA-1000",
          "vendor": "Vonets",
          "versions": [
            {
              "lessThanOrEqual": "3.3.23.6.9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Wodzen reported these vulnerabilities to CISA."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Improper check or handling of exceptional conditions vulnerability \naffecting Vonets\n\n \n\n industrial wifi bridge relays and wifi bridge repeaters, software versions 3.3.23.6.9 and prior, enable an unauthenticated \nremote attacker to cause a denial of service. A specially-crafted \nHTTP request to pre-authentication resources can crash the service."
            }
          ],
          "value": "Improper check or handling of exceptional conditions vulnerability \naffecting Vonets\n\n \n\n industrial wifi bridge relays and wifi bridge repeaters, software versions 3.3.23.6.9 and prior, enable an unauthenticated \nremote attacker to cause a denial of service. A specially-crafted \nHTTP request to pre-authentication resources can crash the service."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.1,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 9.4,
            "baseSeverity": "CRITICAL",
            "privilegesRequired": "HIGH",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "HIGH",
            "subConfidentialityImpact": "HIGH",
            "subIntegrityImpact": "HIGH",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-703",
              "description": "CWE-703",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-08-08T19:43:20.731Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-214-08"
        }
      ],
      "source": {
        "advisory": "ICSA-24-214-08",
        "discovery": "EXTERNAL"
      },
      "title": "Vonets WiFi Bridges Improper Check or Handling of Exceptional Conditions",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Vonets has not responded to requests to work with CISA to mitigate these\n vulnerabilities. Users of the affected products are encouraged to \ncontact \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://usdhs-my.sharepoint.com/personal/grayson_gaylor_associates_cisa_dhs_gov1/_layouts/15/support@vonets.com\"\u003eVonets support\u003c/a\u003e for additional information.\n\n\u003cbr\u003e"
            }
          ],
          "value": "Vonets has not responded to requests to work with CISA to mitigate these\n vulnerabilities. Users of the affected products are encouraged to \ncontact  Vonets support https://usdhs-my.sharepoint.com/personal/grayson_gaylor_associates_cisa_dhs_gov1/_layouts/15/support@vonets.com  for additional information."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2024-39815",
    "datePublished": "2024-08-08T19:33:35.137Z",
    "dateReserved": "2024-07-30T16:15:10.109Z",
    "dateUpdated": "2024-08-21T20:04:38.205Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2024-39815",
      "date": "2026-11-17",
      "epss": "0.00771",
      "percentile": "0.56257"
    },
    "nvd": {
      "cve": {
        "affected": [
          {
            "affectedData": [
              {
                "defaultStatus": "unaffected",
                "product": "VAR1200-H",
                "vendor": "Vonets",
                "versions": [
                  {
                    "lessThanOrEqual": "3.3.23.6.9",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "product": "VAR1200-L",
                "vendor": "Vonets",
                "versions": [
                  {
                    "lessThanOrEqual": "3.3.23.6.9",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "product": "VAR600-H",
                "vendor": "Vonets",
                "versions": [
                  {
                    "lessThanOrEqual": "3.3.23.6.9",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "product": "VAP11AC",
                "vendor": "Vonets",
                "versions": [
                  {
                    "lessThanOrEqual": "3.3.23.6.9",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "product": "VAP11G-500S",
                "vendor": "Vonets",
                "versions": [
                  {
                    "lessThanOrEqual": "3.3.23.6.9",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "product": "VBG1200",
                "vendor": "Vonets",
                "versions": [
                  {
                    "lessThanOrEqual": "3.3.23.6.9",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "product": "VAP11S-5G",
                "vendor": "Vonets",
                "versions": [
                  {
                    "lessThanOrEqual": "3.3.23.6.9",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "product": "VAP11S",
                "vendor": "Vonets",
                "versions": [
                  {
                    "lessThanOrEqual": "3.3.23.6.9",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "product": "VAR11N-300",
                "vendor": "Vonets",
                "versions": [
                  {
                    "lessThanOrEqual": "3.3.23.6.9",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "product": "VAP11G-300",
                "vendor": "Vonets",
                "versions": [
                  {
                    "lessThanOrEqual": "3.3.23.6.9",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "product": "VAP11N-300",
                "vendor": "Vonets",
                "versions": [
                  {
                    "lessThanOrEqual": "3.3.23.6.9",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "product": "VAP11G",
                "vendor": "Vonets",
                "versions": [
                  {
                    "lessThanOrEqual": "3.3.23.6.9",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "product": "VAP11G-500",
                "vendor": "Vonets",
                "versions": [
                  {
                    "lessThanOrEqual": "3.3.23.6.9",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "product": "VBG1200",
                "vendor": "Vonets",
                "versions": [
                  {
                    "lessThanOrEqual": "3.3.23.6.9",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "product": "VAP11AC",
                "vendor": "Vonets",
                "versions": [
                  {
                    "lessThanOrEqual": "3.3.23.6.9",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "product": "VGA-1000",
                "vendor": "Vonets",
                "versions": [
                  {
                    "lessThanOrEqual": "3.3.23.6.9",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "source": "ics-cert@hq.dhs.gov"
          },
          {
            "affectedData": [
              {
                "cpes": [
                  "cpe:2.3:o:vonets:var1200-h_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "var1200-h_firmware",
                "vendor": "vonets",
                "versions": [
                  {
                    "lessThanOrEqual": "3.3.23.6.9",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:vonets:var1200-l_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "var1200-l_firmware",
                "vendor": "vonets",
                "versions": [
                  {
                    "lessThanOrEqual": "3.3.23.6.9",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:vonets:var600-h_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "var600-h_firmware",
                "vendor": "vonets",
                "versions": [
                  {
                    "lessThanOrEqual": "3.3.23.6.9",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:vonets:vap11ac_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "vap11ac_firmware",
                "vendor": "vonets",
                "versions": [
                  {
                    "lessThanOrEqual": "3.3.23.6.9",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:vonets:vap11g-500s_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "vap11g-500s_firmware",
                "vendor": "vonets",
                "versions": [
                  {
                    "lessThanOrEqual": "3.3.23.6.9",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:vonets:vbg1200_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "vbg1200_firmware",
                "vendor": "vonets",
                "versions": [
                  {
                    "lessThanOrEqual": "3.3.23.6.9",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:vonets:vap11s-5g_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "vap11s-5g_firmware",
                "vendor": "vonets",
                "versions": [
                  {
                    "lessThanOrEqual": "3.3.23.6.9",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:vonets:vap11s_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "vap11s_firmware",
                "vendor": "vonets",
                "versions": [
                  {
                    "lessThanOrEqual": "3.3.23.6.9",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:vonets:var11n-300_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "var11n-300_firmware",
                "vendor": "vonets",
                "versions": [
                  {
                    "lessThanOrEqual": "3.3.23.6.9",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:vonets:vap11n-300_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "vap11n-300_firmware",
                "vendor": "vonets",
                "versions": [
                  {
                    "lessThanOrEqual": "3.3.23.6.9",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:vonets:vap11g_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "vap11g_firmware",
                "vendor": "vonets",
                "versions": [
                  {
                    "lessThanOrEqual": "3.3.23.6.9",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:vonets:vga-1000_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "vga-1000_firmware",
                "vendor": "vonets",
                "versions": [
                  {
                    "lessThanOrEqual": "3.3.23.6.9",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:vonets:vap11g-300_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "vap11g-300_firmware",
                "vendor": "vonets",
                "versions": [
                  {
                    "lessThanOrEqual": "3.3.23.6.9",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:vonets:vap11n-300_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "vap11n-300_firmware",
                "vendor": "vonets",
                "versions": [
                  {
                    "lessThanOrEqual": "3.3.23.6.9",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"
          }
        ],
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:vonets:var1200-h_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "94DAF720-5399-46A2-A9AB-3831045B86D2",
                    "versionEndIncluding": "3.3.23.6.9",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:vonets:var1200-h:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "6D2E3C6A-6CC6-4954-B06C-3F023C964426",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:vonets:var1200-l_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "273874D4-43E0-44D4-AB4E-D66DE1F1B824",
                    "versionEndIncluding": "3.3.23.6.9",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:vonets:var1200-l:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "2C4B65A1-D625-4712-8311-685CA0A6438B",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:vonets:var600-h_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "ADCC4730-7801-485C-994F-DB7B942AA9F4",
                    "versionEndIncluding": "3.3.23.6.9",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:vonets:var600-h:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "DB22B21B-526A-4119-9278-E84138D523E4",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:vonets:vap11ac_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "C007C620-CAF2-436E-AAA9-C012CEFCEA3B",
                    "versionEndIncluding": "3.3.23.6.9",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:vonets:vap11ac:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "21B9AA55-A333-4D10-A9D8-19558465F56E",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:vonets:vap11g-500s_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "FDC4DF91-B718-4CFE-BEE7-4E9CFF121C01",
                    "versionEndIncluding": "3.3.23.6.9",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:vonets:vap11g-500s:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "C9EC2642-6A5B-4DA8-A675-B9F3CAD9B35E",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:vonets:vbg1200_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "5BFA8106-50EE-428D-9297-930CE9CC99C1",
                    "versionEndIncluding": "3.3.23.6.9",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:vonets:vbg1200:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "AE4D6B12-50A8-4314-AEDA-E3C669F772C9",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:vonets:vap11s-5g_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "D95A2EE8-B22F-4671-8DF8-3757A335B006",
                    "versionEndIncluding": "3.3.23.6.9",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:vonets:vap11s-5g:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "66E94FE6-235A-46F0-81B0-DFF88C454BB1",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:vonets:vap11s_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "060B7C85-806D-45B3-8268-10AC5E475171",
                    "versionEndIncluding": "3.3.23.6.9",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:vonets:vap11s:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "C434D025-8361-4C2D-AC7D-4E4A44237C27",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:vonets:var11n-300_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "3DFA50C3-2B3E-4755-98FB-63CED2CA7B8F",
                    "versionEndIncluding": "3.3.23.6.9",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:vonets:var11n-300:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "95D5A3C0-8303-4E77-9DE1-75FD9DAED295",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:vonets:vap11g-300_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "42E71F95-814C-4EDA-8647-B03CA6AAFDEB",
                    "versionEndIncluding": "3.3.23.6.9",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:vonets:vap11g-300:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "2B23375E-0E77-4423-AEDA-9A9F26052834",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:vonets:vap11n-300_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "7018E246-D211-4366-8664-90B00E68AA74",
                    "versionEndIncluding": "3.3.23.6.9",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:vonets:vap11n-300:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "ADE0116E-37B8-4E0A-8874-A59989712743",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:vonets:vap11g_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "C9C1B20A-8F03-4C6E-8715-B68DBBBAFB97",
                    "versionEndIncluding": "3.3.23.6.9",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:vonets:vap11g:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "F510F0DC-C170-45A3-989B-2FA8791B4FC1",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:vonets:vap11g-500_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "52909496-4BEB-43DB-80E3-F710BCA0CAA5",
                    "versionEndIncluding": "3.3.23.6.9",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:vonets:vap11g-500:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "B61E3489-034E-4DD2-8699-477647462CF7",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:vonets:vga-1000_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "1FAF11BE-F3F4-4D40-9156-DDB2FFBF9470",
                    "versionEndIncluding": "3.3.23.6.9",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:vonets:vga-1000:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "DA90833B-D40E-42F0-8ECF-86C90E4511C4",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "Improper check or handling of exceptional conditions vulnerability \naffecting Vonets\n\n \n\n industrial wifi bridge relays and wifi bridge repeaters, software versions 3.3.23.6.9 and prior, enable an unauthenticated \nremote attacker to cause a denial of service. A specially-crafted \nHTTP request to pre-authentication resources can crash the service."
          },
          {
            "lang": "es",
            "value": "La verificaci\u00f3n o el manejo inadecuados de la vulnerabilidad de condiciones excepcionales que afectan a los rel\u00e9s de puente wifi industriales y a los repetidores de puente wifi de Vonets, versiones de software 3.3.23.6.9 y anteriores, permiten que un atacante remoto no autenticado provoque una denegaci\u00f3n de servicio. Una solicitud HTTP especialmente manipulada para recursos de autenticaci\u00f3n previa puede bloquear el servicio."
          }
        ],
        "id": "CVE-2024-39815",
        "lastModified": "2026-06-17T07:42:51.210",
        "metrics": {
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 2.3,
              "impactScore": 6.0,
              "source": "ics-cert@hq.dhs.gov",
              "type": "Secondary"
            },
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 3.9,
              "impactScore": 3.6,
              "source": "nvd@nist.gov",
              "type": "Primary"
            }
          ],
          "cvssMetricV40": [
            {
              "cvssData": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "availabilityRequirement": "NOT_DEFINED",
                "baseScore": 9.4,
                "baseSeverity": "CRITICAL",
                "confidentialityRequirement": "NOT_DEFINED",
                "exploitMaturity": "NOT_DEFINED",
                "integrityRequirement": "NOT_DEFINED",
                "modifiedAttackComplexity": "NOT_DEFINED",
                "modifiedAttackRequirements": "NOT_DEFINED",
                "modifiedAttackVector": "NOT_DEFINED",
                "modifiedPrivilegesRequired": "NOT_DEFINED",
                "modifiedSubAvailabilityImpact": "NOT_DEFINED",
                "modifiedSubConfidentialityImpact": "NOT_DEFINED",
                "modifiedSubIntegrityImpact": "NOT_DEFINED",
                "modifiedUserInteraction": "NOT_DEFINED",
                "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
                "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
                "modifiedVulnIntegrityImpact": "NOT_DEFINED",
                "privilegesRequired": "HIGH",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "source": "ics-cert@hq.dhs.gov",
              "type": "Secondary"
            }
          ],
          "ssvcV203": [
            {
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "ssvcData": {
                "id": "CVE-2024-39815",
                "options": [
                  {
                    "exploitation": "none"
                  },
                  {
                    "automatable": "no"
                  },
                  {
                    "technicalImpact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-09T14:41:59.876924Z",
                "version": "2.0.3"
              }
            }
          ]
        },
        "published": "2024-08-12T13:38:25.150",
        "references": [
          {
            "source": "ics-cert@hq.dhs.gov",
            "tags": [
              "Third Party Advisory",
              "US Government Resource"
            ],
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-214-08"
          }
        ],
        "sourceIdentifier": "ics-cert@hq.dhs.gov",
        "vulnStatus": "Analyzed",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-703"
              }
            ],
            "source": "ics-cert@hq.dhs.gov",
            "type": "Secondary"
          },
          {
            "description": [
              {
                "lang": "en",
                "value": "NVD-CWE-noinfo"
              }
            ],
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      }
    },
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:o:vonets:var1200-h_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "var1200-h_firmware",
                "vendor": "vonets",
                "versions": [
                  {
                    "lessThanOrEqual": "3.3.23.6.9",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:vonets:var1200-l_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "var1200-l_firmware",
                "vendor": "vonets",
                "versions": [
                  {
                    "lessThanOrEqual": "3.3.23.6.9",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:vonets:var600-h_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "var600-h_firmware",
                "vendor": "vonets",
                "versions": [
                  {
                    "lessThanOrEqual": "3.3.23.6.9",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:vonets:vap11ac_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "vap11ac_firmware",
                "vendor": "vonets",
                "versions": [
                  {
                    "lessThanOrEqual": "3.3.23.6.9",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:vonets:vap11g-500s_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "vap11g-500s_firmware",
                "vendor": "vonets",
                "versions": [
                  {
                    "lessThanOrEqual": "3.3.23.6.9",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:vonets:vbg1200_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "vbg1200_firmware",
                "vendor": "vonets",
                "versions": [
                  {
                    "lessThanOrEqual": "3.3.23.6.9",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:vonets:vap11s-5g_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "vap11s-5g_firmware",
                "vendor": "vonets",
                "versions": [
                  {
                    "lessThanOrEqual": "3.3.23.6.9",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:vonets:vap11s_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "vap11s_firmware",
                "vendor": "vonets",
                "versions": [
                  {
                    "lessThanOrEqual": "3.3.23.6.9",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:vonets:var11n-300_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "var11n-300_firmware",
                "vendor": "vonets",
                "versions": [
                  {
                    "lessThanOrEqual": "3.3.23.6.9",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:vonets:vap11n-300_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "vap11n-300_firmware",
                "vendor": "vonets",
                "versions": [
                  {
                    "lessThanOrEqual": "3.3.23.6.9",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:vonets:vap11g_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "vap11g_firmware",
                "vendor": "vonets",
                "versions": [
                  {
                    "lessThanOrEqual": "3.3.23.6.9",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:vonets:vga-1000_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "vga-1000_firmware",
                "vendor": "vonets",
                "versions": [
                  {
                    "lessThanOrEqual": "3.3.23.6.9",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:vonets:vap11g-300_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "vap11g-300_firmware",
                "vendor": "vonets",
                "versions": [
                  {
                    "lessThanOrEqual": "3.3.23.6.9",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:vonets:vap11n-300_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "vap11n-300_firmware",
                "vendor": "vonets",
                "versions": [
                  {
                    "lessThanOrEqual": "3.3.23.6.9",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-39815",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-08-09T14:41:59.876924Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-08-09T14:41:53.861Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "VAR1200-H",
              "vendor": "Vonets",
              "versions": [
                {
                  "lessThanOrEqual": "3.3.23.6.9",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "VAR1200-L",
              "vendor": "Vonets",
              "versions": [
                {
                  "lessThanOrEqual": "3.3.23.6.9",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "VAR600-H",
              "vendor": "Vonets",
              "versions": [
                {
                  "lessThanOrEqual": "3.3.23.6.9",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "VAP11AC",
              "vendor": "Vonets",
              "versions": [
                {
                  "lessThanOrEqual": "3.3.23.6.9",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "VAP11G-500S",
              "vendor": "Vonets",
              "versions": [
                {
                  "lessThanOrEqual": "3.3.23.6.9",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "VBG1200",
              "vendor": "Vonets",
              "versions": [
                {
                  "lessThanOrEqual": "3.3.23.6.9",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "VAP11S-5G",
              "vendor": "Vonets",
              "versions": [
                {
                  "lessThanOrEqual": "3.3.23.6.9",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "VAP11S",
              "vendor": "Vonets",
              "versions": [
                {
                  "lessThanOrEqual": "3.3.23.6.9",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "VAR11N-300",
              "vendor": "Vonets",
              "versions": [
                {
                  "lessThanOrEqual": "3.3.23.6.9",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "VAP11G-300",
              "vendor": "Vonets",
              "versions": [
                {
                  "lessThanOrEqual": "3.3.23.6.9",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "VAP11N-300",
              "vendor": "Vonets",
              "versions": [
                {
                  "lessThanOrEqual": "3.3.23.6.9",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "VAP11G",
              "vendor": "Vonets",
              "versions": [
                {
                  "lessThanOrEqual": "3.3.23.6.9",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "VAP11G-500",
              "vendor": "Vonets",
              "versions": [
                {
                  "lessThanOrEqual": "3.3.23.6.9",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "VBG1200",
              "vendor": "Vonets",
              "versions": [
                {
                  "lessThanOrEqual": "3.3.23.6.9",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "VAP11AC",
              "vendor": "Vonets",
              "versions": [
                {
                  "lessThanOrEqual": "3.3.23.6.9",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "VGA-1000",
              "vendor": "Vonets",
              "versions": [
                {
                  "lessThanOrEqual": "3.3.23.6.9",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Wodzen reported these vulnerabilities to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Improper check or handling of exceptional conditions vulnerability \naffecting Vonets\n\n \n\n industrial wifi bridge relays and wifi bridge repeaters, software versions 3.3.23.6.9 and prior, enable an unauthenticated \nremote attacker to cause a denial of service. A specially-crafted \nHTTP request to pre-authentication resources can crash the service."
                }
              ],
              "value": "Improper check or handling of exceptional conditions vulnerability \naffecting Vonets\n\n \n\n industrial wifi bridge relays and wifi bridge repeaters, software versions 3.3.23.6.9 and prior, enable an unauthenticated \nremote attacker to cause a denial of service. A specially-crafted \nHTTP request to pre-authentication resources can crash the service."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 9.4,
                "baseSeverity": "CRITICAL",
                "privilegesRequired": "HIGH",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-703",
                  "description": "CWE-703",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-08-08T19:43:20.731Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-214-08"
            }
          ],
          "source": {
            "advisory": "ICSA-24-214-08",
            "discovery": "EXTERNAL"
          },
          "title": "Vonets WiFi Bridges Improper Check or Handling of Exceptional Conditions",
          "workarounds": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Vonets has not responded to requests to work with CISA to mitigate these\n vulnerabilities. Users of the affected products are encouraged to \ncontact \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://usdhs-my.sharepoint.com/personal/grayson_gaylor_associates_cisa_dhs_gov1/_layouts/15/support@vonets.com\"\u003eVonets support\u003c/a\u003e for additional information.\n\n\u003cbr\u003e"
                }
              ],
              "value": "Vonets has not responded to requests to work with CISA to mitigate these\n vulnerabilities. Users of the affected products are encouraged to \ncontact  Vonets support https://usdhs-my.sharepoint.com/personal/grayson_gaylor_associates_cisa_dhs_gov1/_layouts/15/support@vonets.com  for additional information."
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2024-39815",
        "datePublished": "2024-08-08T19:33:35.137Z",
        "dateReserved": "2024-07-30T16:15:10.109Z",
        "dateUpdated": "2024-08-21T20:04:38.205Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Workarounds

CNA · icscert
Vonets has not responded to requests to work with CISA to mitigate these vulnerabilities. Users of the affected products are encouraged to contact Vonets support https://usdhs-my.sharepoint.com/personal/grayson_gaylor_associates_cisa_dhs_gov1/_layouts/15/support@vonets.com for additional information.

Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline

Sightings and recorded dates, grouped by day · UTC

JSON
How durations are calculated

Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.

Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.

Events included in the timeline

Loading timeline…


    Loading…

    Loading…

    Loading…

    Related by attack behaviour

    Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.