CVE-2024-37143 (GCVE-0-2024-37143)
Vulnerability from cvelistv5 – Published: 2024-12-10 02:25 – Updated: 2024-12-11 17:16- CWE-59 - Improper Link Resolution Before File Access ('Link Following')
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00025834… | vendor-advisory |
| Vendor | Product | Version | CPE status | |
|---|---|---|---|---|
| Dell | Dell PowerFlex appliance |
Affected:
N/A , < 46.381.00
(semver)
Affected: N/A , < 46.376.00 (semver) |
guessed | |
| Dell | Dell PowerFlex rack |
Affected:
N/A , < 3.8.1.0
(semver)
Affected: N/A , < 3.7.6.0 (semver) |
guessed | |
| Dell | Dell PowerFlex custom node |
Affected:
N/A , < 4.6.1.0
(semver)
|
guessed | |
| Dell | Dell InsightIQ |
Affected:
N/A , < 5.1.1
(semver)
|
guessed | |
| Dell | Dell Data Lakehouse |
Affected:
N/A , < 1.2.0.0
(semver)
|
guessed |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-37143",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-12-11T17:15:39.353490Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-12-11T17:16:29.723Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Dell PowerFlex appliance",
"vendor": "Dell",
"versions": [
{
"lessThan": "46.381.00",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "46.376.00",
"status": "affected",
"version": "N/A",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Dell PowerFlex rack",
"vendor": "Dell",
"versions": [
{
"lessThan": "3.8.1.0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "3.7.6.0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Dell PowerFlex custom node",
"vendor": "Dell",
"versions": [
{
"lessThan": "4.6.1.0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Dell InsightIQ",
"vendor": "Dell",
"versions": [
{
"lessThan": "5.1.1",
"status": "affected",
"version": "N/A",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Dell Data Lakehouse",
"vendor": "Dell",
"versions": [
{
"lessThan": "1.2.0.0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
}
]
}
],
"datePublic": "2024-12-09T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerFlex appliance versions prior to IC 46.381.00 and IC 46.376.00, Dell PowerFlex rack versions prior to RCM 3.8.1.0 (for RCM 3.8.x train) and prior to RCM 3.7.6.0 (for RCM 3.7.x train), Dell PowerFlex custom node using PowerFlex Manager versions prior to 4.6.1.0, Dell InsightIQ versions prior to 5.1.1, and Dell Data Lakehouse versions prior to 1.2.0.0 contain an Improper Link Resolution Before File Access vulnerability. An unauthenticated attacker with remote access could potentially exploit this vulnerability to execute arbitrary code on the system."
}
],
"value": "Dell PowerFlex appliance versions prior to IC 46.381.00 and IC 46.376.00, Dell PowerFlex rack versions prior to RCM 3.8.1.0 (for RCM 3.8.x train) and prior to RCM 3.7.6.0 (for RCM 3.7.x train), Dell PowerFlex custom node using PowerFlex Manager versions prior to 4.6.1.0, Dell InsightIQ versions prior to 5.1.1, and Dell Data Lakehouse versions prior to 1.2.0.0 contain an Improper Link Resolution Before File Access vulnerability. An unauthenticated attacker with remote access could potentially exploit this vulnerability to execute arbitrary code on the system."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 10,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-59",
"description": "CWE-59: Improper Link Resolution Before File Access (\u0027Link Following\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-12-10T02:25:33.225Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000258342/dsa-2024-405-security-update-for-dell-products-for-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eFor remediation for PowerFlex Manager versions prior to 4.6.1 (RCMs prior to 3.7.6.0/3.8.1.0 or ICs prior to 46.376.00/46.381.00), reference \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.dell.com/support/kbdoc/en-us/000231116\"\u003eKB Article 000231116 Mitigation for Powerflex Manager CVE-2024-37143\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;(customer login required).\u003c/span\u003e\n\n\u003cbr\u003e"
}
],
"value": "For remediation for PowerFlex Manager versions prior to 4.6.1 (RCMs prior to 3.7.6.0/3.8.1.0 or ICs prior to 46.376.00/46.381.00), reference KB Article 000231116 Mitigation for Powerflex Manager CVE-2024-37143 https://www.dell.com/support/kbdoc/en-us/000231116 \u00a0(customer login required)."
}
],
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2024-37143",
"datePublished": "2024-12-10T02:25:33.225Z",
"dateReserved": "2024-06-03T12:10:32.206Z",
"dateUpdated": "2024-12-11T17:16:29.723Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2024-37143",
"date": "2026-11-28",
"epss": "0.01361",
"percentile": "0.71915"
},
"nvd": {
"cve": {
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "Dell PowerFlex appliance",
"vendor": "Dell",
"versions": [
{
"lessThan": "46.381.00",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "46.376.00",
"status": "affected",
"version": "N/A",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Dell PowerFlex rack",
"vendor": "Dell",
"versions": [
{
"lessThan": "3.8.1.0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "3.7.6.0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Dell PowerFlex custom node",
"vendor": "Dell",
"versions": [
{
"lessThan": "4.6.1.0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Dell InsightIQ",
"vendor": "Dell",
"versions": [
{
"lessThan": "5.1.1",
"status": "affected",
"version": "N/A",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Dell Data Lakehouse",
"vendor": "Dell",
"versions": [
{
"lessThan": "1.2.0.0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
}
]
}
],
"source": "security_alert@emc.com"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:dell:data_lakehouse:*:*:*:*:*:*:*:*",
"matchCriteriaId": "80278A58-A1BB-4CD1-93B7-2BEC2D227FCC",
"versionEndExcluding": "1.2.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:dell:insightiq:*:*:*:*:*:*:*:*",
"matchCriteriaId": "0544C44D-29E4-45AB-A12B-B05F0A2ECC14",
"versionEndExcluding": "5.1.1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:dell:powerflex_appliance_intelligent_catalog:*:*:*:*:*:*:*:*",
"matchCriteriaId": "680FAFDC-0CF1-4B01-B0AF-6775389B33A4",
"versionEndExcluding": "46.376.00",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:dell:powerflex_manager:*:*:*:*:*:*:*:*",
"matchCriteriaId": "44B7F933-3F65-4B22-9EC6-323B4ED600A1",
"versionEndExcluding": "4.6.1.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:dell:powerflex_rack_release_certification_matrix:*:*:*:*:*:*:*:*",
"matchCriteriaId": "427C3C57-3812-4951-A6F6-2D598391B633",
"versionEndExcluding": "3.7.6.0",
"versionStartIncluding": "3.7.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:dell:powerflex_rack_release_certification_matrix:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BF3A561D-15B4-47E4-B578-F21DA37D3830",
"versionEndExcluding": "3.8.1.0",
"versionStartIncluding": "3.8.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Dell PowerFlex appliance versions prior to IC 46.381.00 and IC 46.376.00, Dell PowerFlex rack versions prior to RCM 3.8.1.0 (for RCM 3.8.x train) and prior to RCM 3.7.6.0 (for RCM 3.7.x train), Dell PowerFlex custom node using PowerFlex Manager versions prior to 4.6.1.0, Dell InsightIQ versions prior to 5.1.1, and Dell Data Lakehouse versions prior to 1.2.0.0 contain an Improper Link Resolution Before File Access vulnerability. An unauthenticated attacker with remote access could potentially exploit this vulnerability to execute arbitrary code on the system."
},
{
"lang": "es",
"value": "Las versiones del dispositivo Dell PowerFlex anteriores a IC 46.381.00 e IC 46.376.00, las versiones de bastidor de Dell PowerFlex anteriores a RCM 3.8.1.0 (para el tren RCM 3.8.x) y anteriores a RCM 3.7.6.0 (para el tren RCM 3.7.x), el nodo personalizado de Dell PowerFlex que utiliza versiones de PowerFlex Manager anteriores a 4.6.1.0, las versiones de Dell InsightIQ anteriores a 5.1.1 y las versiones de Dell Data Lakehouse anteriores a 1.2.0.0 contienen una vulnerabilidad de resoluci\u00f3n de v\u00ednculo incorrecta antes del acceso a archivos. Un atacante no autenticado con acceso remoto podr\u00eda aprovechar esta vulnerabilidad para ejecutar c\u00f3digo arbitrario en el sistema."
}
],
"id": "CVE-2024-37143",
"lastModified": "2026-06-17T07:37:50.063",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 10.0,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 6.0,
"source": "security_alert@emc.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2024-37143",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-12-11T17:15:39.353490Z",
"version": "2.0.3"
}
}
]
},
"published": "2024-12-10T03:15:05.573",
"references": [
{
"source": "security_alert@emc.com",
"tags": [
"Vendor Advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000258342/dsa-2024-405-security-update-for-dell-products-for-multiple-vulnerabilities"
}
],
"sourceIdentifier": "security_alert@emc.com",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-59"
}
],
"source": "security_alert@emc.com",
"type": "Secondary"
}
]
}
},
"redhat_vex": {
"current_release_date": "2025-05-28T22:08:03+00:00",
"cve": "CVE-2024-37143",
"id": "CVE-2024-37143",
"initial_release_date": "2024-12-09T06:30:00+00:00",
"product_status:known_not_affected": "1",
"source": "Red Hat CSAF VEX",
"status": "final",
"title": "CVE-2024-37143",
"url": "https://security.access.redhat.com/data/csaf/v2/vex/2024/cve-2024-37143.json",
"version": "3"
},
"vulnrichment": {
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-37143",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-12-11T17:15:39.353490Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-12-11T17:15:52.562Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Dell PowerFlex appliance",
"vendor": "Dell",
"versions": [
{
"lessThan": "46.381.00",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "46.376.00",
"status": "affected",
"version": "N/A",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Dell PowerFlex rack",
"vendor": "Dell",
"versions": [
{
"lessThan": "3.8.1.0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "3.7.6.0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Dell PowerFlex custom node",
"vendor": "Dell",
"versions": [
{
"lessThan": "4.6.1.0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Dell InsightIQ",
"vendor": "Dell",
"versions": [
{
"lessThan": "5.1.1",
"status": "affected",
"version": "N/A",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Dell Data Lakehouse",
"vendor": "Dell",
"versions": [
{
"lessThan": "1.2.0.0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
}
]
}
],
"datePublic": "2024-12-09T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerFlex appliance versions prior to IC 46.381.00 and IC 46.376.00, Dell PowerFlex rack versions prior to RCM 3.8.1.0 (for RCM 3.8.x train) and prior to RCM 3.7.6.0 (for RCM 3.7.x train), Dell PowerFlex custom node using PowerFlex Manager versions prior to 4.6.1.0, Dell InsightIQ versions prior to 5.1.1, and Dell Data Lakehouse versions prior to 1.2.0.0 contain an Improper Link Resolution Before File Access vulnerability. An unauthenticated attacker with remote access could potentially exploit this vulnerability to execute arbitrary code on the system."
}
],
"value": "Dell PowerFlex appliance versions prior to IC 46.381.00 and IC 46.376.00, Dell PowerFlex rack versions prior to RCM 3.8.1.0 (for RCM 3.8.x train) and prior to RCM 3.7.6.0 (for RCM 3.7.x train), Dell PowerFlex custom node using PowerFlex Manager versions prior to 4.6.1.0, Dell InsightIQ versions prior to 5.1.1, and Dell Data Lakehouse versions prior to 1.2.0.0 contain an Improper Link Resolution Before File Access vulnerability. An unauthenticated attacker with remote access could potentially exploit this vulnerability to execute arbitrary code on the system."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 10,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-59",
"description": "CWE-59: Improper Link Resolution Before File Access (\u0027Link Following\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-12-10T02:25:33.225Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000258342/dsa-2024-405-security-update-for-dell-products-for-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eFor remediation for PowerFlex Manager versions prior to 4.6.1 (RCMs prior to 3.7.6.0/3.8.1.0 or ICs prior to 46.376.00/46.381.00), reference \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.dell.com/support/kbdoc/en-us/000231116\"\u003eKB Article 000231116 Mitigation for Powerflex Manager CVE-2024-37143\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;(customer login required).\u003c/span\u003e\n\n\u003cbr\u003e"
}
],
"value": "For remediation for PowerFlex Manager versions prior to 4.6.1 (RCMs prior to 3.7.6.0/3.8.1.0 or ICs prior to 46.376.00/46.381.00), reference KB Article 000231116 Mitigation for Powerflex Manager CVE-2024-37143 https://www.dell.com/support/kbdoc/en-us/000231116 \u00a0(customer login required)."
}
],
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2024-37143",
"datePublished": "2024-12-10T02:25:33.225Z",
"dateReserved": "2024-06-03T12:10:32.206Z",
"dateUpdated": "2024-12-11T17:16:29.723Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Workarounds
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation. The method is described in a publication.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.