CVE-2024-29207 (GCVE-0-2024-29207)
Vulnerability from cvelistv5 – Published: 2024-05-07 16:40 – Updated: 2024-08-02 01:10- CWE-284 - Improper Access Control
| Vendor | Product | Version | CPE status | |
|---|---|---|---|---|
| Ubiquiti Inc | UniFi Connect Application |
Affected:
3.10.7 , < 3.10.7
(semver)
|
guessed | |
| Ubiquiti Inc | UniFi Connect EV Station |
Affected:
1.2.15 , < 1.2.15
(semver)
|
guessed | |
| Ubiquiti Inc | UniFi Connect EV Station Pro |
Affected:
1.2.15 , < 1.2.15
(semver)
|
guessed | |
| Ubiquiti Inc | UniFi Connect Display |
Affected:
1.11.348 , < 1.11.348
(semver)
|
guessed | |
| Ubiquiti Inc | UniFi Connect Display Cast |
Affected:
1.8.255 , < 1.8.255
(semver)
|
guessed | |
| ubiquiti | unifi_connect_display_cast |
Affected:
1.8.255
cpe:2.3:a:ubiquiti:unifi_connect_display_cast:1.8.255:*:*:*:*:*:*:* |
||
| ubiquiti | unifi_connect_display |
Affected:
1.11.348
cpe:2.3:a:ubiquiti:unifi_connect_display:1.11.348:*:*:*:*:*:*:* |
||
| ubiquiti | unifi_connect_application |
Affected:
3.10.7
cpe:2.3:a:ubiquiti:unifi_connect_application:3.10.7:*:*:*:*:*:*:* |
||
| ubiquiti | unifi_connect_ev_station |
Affected:
1.2.15
cpe:2.3:a:ubiquiti:unifi_connect_ev_station:1.2.15:*:*:*:*:*:*:* |
||
| ubiquiti | unifi_connect_ev_station_pro |
Affected:
1.2.15.0
cpe:2.3:a:ubiquiti:unifi_connect_ev_station_pro:1.2.15.0:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:ubiquiti:unifi_connect_display_cast:1.8.255:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "unifi_connect_display_cast",
"vendor": "ubiquiti",
"versions": [
{
"status": "affected",
"version": "1.8.255"
}
]
},
{
"cpes": [
"cpe:2.3:a:ubiquiti:unifi_connect_display:1.11.348:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "unifi_connect_display",
"vendor": "ubiquiti",
"versions": [
{
"status": "affected",
"version": "1.11.348"
}
]
},
{
"cpes": [
"cpe:2.3:a:ubiquiti:unifi_connect_application:3.10.7:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "unifi_connect_application",
"vendor": "ubiquiti",
"versions": [
{
"status": "affected",
"version": "3.10.7"
}
]
},
{
"cpes": [
"cpe:2.3:a:ubiquiti:unifi_connect_ev_station:1.2.15:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "unifi_connect_ev_station",
"vendor": "ubiquiti",
"versions": [
{
"status": "affected",
"version": "1.2.15 "
}
]
},
{
"cpes": [
"cpe:2.3:a:ubiquiti:unifi_connect_ev_station_pro:1.2.15.0:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "unifi_connect_ev_station_pro",
"vendor": "ubiquiti",
"versions": [
{
"status": "affected",
"version": "1.2.15.0"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-29207",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-07T19:34:11.302957Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284 Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-04T17:56:46.353Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T01:10:55.406Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://community.ui.com/releases/Security-Advisory-bulletin-039-039/44e24007-2c2c-4ac0-bebf-3f19b9b24f09"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "UniFi Connect Application",
"vendor": "Ubiquiti Inc",
"versions": [
{
"lessThan": "3.10.7",
"status": "affected",
"version": "3.10.7",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "UniFi Connect EV Station",
"vendor": "Ubiquiti Inc",
"versions": [
{
"lessThan": "1.2.15",
"status": "affected",
"version": "1.2.15",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "UniFi Connect EV Station Pro ",
"vendor": "Ubiquiti Inc",
"versions": [
{
"lessThan": "1.2.15",
"status": "affected",
"version": "1.2.15",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "UniFi Connect Display",
"vendor": "Ubiquiti Inc",
"versions": [
{
"lessThan": "1.11.348",
"status": "affected",
"version": "1.11.348",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "UniFi Connect Display Cast",
"vendor": "Ubiquiti Inc",
"versions": [
{
"lessThan": "1.8.255",
"status": "affected",
"version": "1.8.255",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An Improper Certificate Validation could allow a malicious actor with access to an adjacent network to take control of the system. \n\n \n\nAffected Products:\n\nUniFi Connect Application (Version 3.7.9 and earlier) \n\nUniFi Connect EV Station (Version 1.1.18 and earlier) \n\nUniFi Connect EV Station Pro (Version 1.1.18 and earlier)\n\nUniFi Connect Display (Version 1.9.324 and earlier)\n\nUniFi Connect Display Cast (Version 1.6.225 and earlier)\n\n \n\nMitigation:\n\nUpdate UniFi Connect Application to Version 3.10.7 or later.\n\nUpdate UniFi Connect EV Station to Version 1.2.15 or later.\n\nUpdate UniFi Connect EV Station Pro to Version 1.2.15 or later.\n\nUpdate UniFi Connect Display to Version 1.11.348 or later.\n\nUpdate UniFi Connect Display Cast to Version 1.8.255 or later.\n\n"
}
],
"metrics": [
{
"cvssV3_0": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-05-07T16:40:02.502Z",
"orgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
"shortName": "hackerone"
},
"references": [
{
"url": "https://community.ui.com/releases/Security-Advisory-bulletin-039-039/44e24007-2c2c-4ac0-bebf-3f19b9b24f09"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
"assignerShortName": "hackerone",
"cveId": "CVE-2024-29207",
"datePublished": "2024-05-07T16:40:02.502Z",
"dateReserved": "2024-03-19T01:04:06.323Z",
"dateUpdated": "2024-08-02T01:10:55.406Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2024-29207",
"date": "2026-11-11",
"epss": "0.00325",
"percentile": "0.25907"
},
"nvd": {
"cve": {
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "UniFi Connect Application",
"vendor": "Ubiquiti Inc",
"versions": [
{
"lessThan": "3.10.7",
"status": "affected",
"version": "3.10.7",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "UniFi Connect EV Station",
"vendor": "Ubiquiti Inc",
"versions": [
{
"lessThan": "1.2.15",
"status": "affected",
"version": "1.2.15",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "UniFi Connect EV Station Pro ",
"vendor": "Ubiquiti Inc",
"versions": [
{
"lessThan": "1.2.15",
"status": "affected",
"version": "1.2.15",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "UniFi Connect Display",
"vendor": "Ubiquiti Inc",
"versions": [
{
"lessThan": "1.11.348",
"status": "affected",
"version": "1.11.348",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "UniFi Connect Display Cast",
"vendor": "Ubiquiti Inc",
"versions": [
{
"lessThan": "1.8.255",
"status": "affected",
"version": "1.8.255",
"versionType": "semver"
}
]
}
],
"source": "support@hackerone.com"
},
{
"affectedData": [
{
"cpes": [
"cpe:2.3:a:ubiquiti:unifi_connect_display_cast:1.8.255:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "unifi_connect_display_cast",
"vendor": "ubiquiti",
"versions": [
{
"status": "affected",
"version": "1.8.255"
}
]
},
{
"cpes": [
"cpe:2.3:a:ubiquiti:unifi_connect_display:1.11.348:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "unifi_connect_display",
"vendor": "ubiquiti",
"versions": [
{
"status": "affected",
"version": "1.11.348"
}
]
},
{
"cpes": [
"cpe:2.3:a:ubiquiti:unifi_connect_application:3.10.7:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "unifi_connect_application",
"vendor": "ubiquiti",
"versions": [
{
"status": "affected",
"version": "3.10.7"
}
]
},
{
"cpes": [
"cpe:2.3:a:ubiquiti:unifi_connect_ev_station:1.2.15:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "unifi_connect_ev_station",
"vendor": "ubiquiti",
"versions": [
{
"status": "affected",
"version": "1.2.15 "
}
]
},
{
"cpes": [
"cpe:2.3:a:ubiquiti:unifi_connect_ev_station_pro:1.2.15.0:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "unifi_connect_ev_station_pro",
"vendor": "ubiquiti",
"versions": [
{
"status": "affected",
"version": "1.2.15.0"
}
]
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "An Improper Certificate Validation could allow a malicious actor with access to an adjacent network to take control of the system. \n\n \n\nAffected Products:\n\nUniFi Connect Application (Version 3.7.9 and earlier) \n\nUniFi Connect EV Station (Version 1.1.18 and earlier) \n\nUniFi Connect EV Station Pro (Version 1.1.18 and earlier)\n\nUniFi Connect Display (Version 1.9.324 and earlier)\n\nUniFi Connect Display Cast (Version 1.6.225 and earlier)\n\n \n\nMitigation:\n\nUpdate UniFi Connect Application to Version 3.10.7 or later.\n\nUpdate UniFi Connect EV Station to Version 1.2.15 or later.\n\nUpdate UniFi Connect EV Station Pro to Version 1.2.15 or later.\n\nUpdate UniFi Connect Display to Version 1.11.348 or later.\n\nUpdate UniFi Connect Display Cast to Version 1.8.255 or later.\n\n"
},
{
"lang": "es",
"value": "Una validaci\u00f3n de certificado incorrecta podr\u00eda permitir que un actor malintencionado con acceso a una red adyacente tome el control del sistema. Productos afectados: Aplicaci\u00f3n UniFi Connect (Versi\u00f3n 3.7.9 y anteriores) UniFi Connect EV Station (Versi\u00f3n 1.1.18 y anteriores) UniFi Connect EV Station Pro (Versi\u00f3n 1.1.18 y anteriores) UniFi Connect Display (Versi\u00f3n 1.9.324 y anteriores) UniFi Connect Display Cast (versi\u00f3n 1.6.225 y anteriores) Mitigaci\u00f3n: actualice la aplicaci\u00f3n UniFi Connect a la versi\u00f3n 3.10.7 o posterior. Actualice UniFi Connect EV Station a la versi\u00f3n 1.2.15 o posterior. Actualice UniFi Connect EV Station Pro a la versi\u00f3n 1.2.15 o posterior. Actualice UniFi Connect Display a la versi\u00f3n 1.11.348 o posterior. Actualice UniFi Connect Display Cast a la versi\u00f3n 1.8.255 o posterior."
}
],
"id": "CVE-2024-29207",
"lastModified": "2026-06-17T07:22:37.817",
"metrics": {
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"exploitabilityScore": 1.6,
"impactScore": 5.9,
"source": "support@hackerone.com",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2024-29207",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-07T19:34:11.302957Z",
"version": "2.0.3"
}
}
]
},
"published": "2024-05-07T17:15:08.183",
"references": [
{
"source": "support@hackerone.com",
"url": "https://community.ui.com/releases/Security-Advisory-bulletin-039-039/44e24007-2c2c-4ac0-bebf-3f19b9b24f09"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "https://community.ui.com/releases/Security-Advisory-bulletin-039-039/44e24007-2c2c-4ac0-bebf-3f19b9b24f09"
}
],
"sourceIdentifier": "support@hackerone.com",
"vulnStatus": "Deferred",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-284"
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
}
},
"redhat_vex": {
"current_release_date": "2025-05-28T22:14:48+00:00",
"cve": "CVE-2024-29207",
"id": "CVE-2024-29207",
"initial_release_date": "2024-01-01T00:00:00+00:00",
"product_status:known_not_affected": "1",
"source": "Red Hat CSAF VEX",
"status": "final",
"title": "CVE-2024-29207",
"url": "https://security.access.redhat.com/data/csaf/v2/vex/2024/cve-2024-29207.json",
"version": "3"
},
"vulnrichment": {
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T01:10:55.406Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://community.ui.com/releases/Security-Advisory-bulletin-039-039/44e24007-2c2c-4ac0-bebf-3f19b9b24f09"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:a:ubiquiti:unifi_connect_display_cast:1.8.255:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "unifi_connect_display_cast",
"vendor": "ubiquiti",
"versions": [
{
"status": "affected",
"version": "1.8.255"
}
]
},
{
"cpes": [
"cpe:2.3:a:ubiquiti:unifi_connect_display:1.11.348:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "unifi_connect_display",
"vendor": "ubiquiti",
"versions": [
{
"status": "affected",
"version": "1.11.348"
}
]
},
{
"cpes": [
"cpe:2.3:a:ubiquiti:unifi_connect_application:3.10.7:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "unifi_connect_application",
"vendor": "ubiquiti",
"versions": [
{
"status": "affected",
"version": "3.10.7"
}
]
},
{
"cpes": [
"cpe:2.3:a:ubiquiti:unifi_connect_ev_station:1.2.15:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "unifi_connect_ev_station",
"vendor": "ubiquiti",
"versions": [
{
"status": "affected",
"version": "1.2.15 "
}
]
},
{
"cpes": [
"cpe:2.3:a:ubiquiti:unifi_connect_ev_station_pro:1.2.15.0:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "unifi_connect_ev_station_pro",
"vendor": "ubiquiti",
"versions": [
{
"status": "affected",
"version": "1.2.15.0"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-29207",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-07T19:34:11.302957Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284 Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-05-07T19:40:49.698Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "UniFi Connect Application",
"vendor": "Ubiquiti Inc",
"versions": [
{
"lessThan": "3.10.7",
"status": "affected",
"version": "3.10.7",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "UniFi Connect EV Station",
"vendor": "Ubiquiti Inc",
"versions": [
{
"lessThan": "1.2.15",
"status": "affected",
"version": "1.2.15",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "UniFi Connect EV Station Pro ",
"vendor": "Ubiquiti Inc",
"versions": [
{
"lessThan": "1.2.15",
"status": "affected",
"version": "1.2.15",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "UniFi Connect Display",
"vendor": "Ubiquiti Inc",
"versions": [
{
"lessThan": "1.11.348",
"status": "affected",
"version": "1.11.348",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "UniFi Connect Display Cast",
"vendor": "Ubiquiti Inc",
"versions": [
{
"lessThan": "1.8.255",
"status": "affected",
"version": "1.8.255",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An Improper Certificate Validation could allow a malicious actor with access to an adjacent network to take control of the system. \n\n \n\nAffected Products:\n\nUniFi Connect Application (Version 3.7.9 and earlier) \n\nUniFi Connect EV Station (Version 1.1.18 and earlier) \n\nUniFi Connect EV Station Pro (Version 1.1.18 and earlier)\n\nUniFi Connect Display (Version 1.9.324 and earlier)\n\nUniFi Connect Display Cast (Version 1.6.225 and earlier)\n\n \n\nMitigation:\n\nUpdate UniFi Connect Application to Version 3.10.7 or later.\n\nUpdate UniFi Connect EV Station to Version 1.2.15 or later.\n\nUpdate UniFi Connect EV Station Pro to Version 1.2.15 or later.\n\nUpdate UniFi Connect Display to Version 1.11.348 or later.\n\nUpdate UniFi Connect Display Cast to Version 1.8.255 or later.\n\n"
}
],
"metrics": [
{
"cvssV3_0": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-05-07T16:40:02.502Z",
"orgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
"shortName": "hackerone"
},
"references": [
{
"url": "https://community.ui.com/releases/Security-Advisory-bulletin-039-039/44e24007-2c2c-4ac0-bebf-3f19b9b24f09"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
"assignerShortName": "hackerone",
"cveId": "CVE-2024-29207",
"datePublished": "2024-05-07T16:40:02.502Z",
"dateReserved": "2024-03-19T01:04:06.323Z",
"dateUpdated": "2024-08-02T01:10:55.406Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.