CVE-2024-0840 (GCVE-0-2024-0840)

Vulnerability from cvelistv5 – Published: 2024-04-29 18:42 – Updated: 2024-08-01 18:18
VLAI
Title
Grandstream UCM Series IP PBX HTTP Parameter Injection
Summary
The Grandstream UCM Series IP PBX before firmware version 1.0.20.52 is affected by a parameter injection vulnerability in the HTTP interface. A remote and authenticated attacker can execute arbitrary code by sending a crafted HTTP request. Authentication may be possible using a default user and password. Affected models are the UCM6202, UCM6204, UCM6208, and UCM6510.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-05-01 19:17 UTC
CWE
  • CWE-141 - Improper Neutralization of Parameter/Argument Delimiters
Impacted products
Vendor Product Version CPE status
Grandstream UCM Series Affected: 0 , < <1.0.20.52 (custom)
guessed Create a notification for this product.
grandstream ucm6202_firmware Affected: 0 , < 1.0.20.52 (custom)
    cpe:2.3:a:grandstream:ucm6202_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
grandstream ucm6204_firmware Affected: 0 , < 1.0.20.52 (custom)
    cpe:2.3:a:grandstream:ucm6204_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
grandstream ucm6208_firmware Affected: 0 , < 1.0.20.52 (custom)
    cpe:2.3:a:grandstream:ucm6208_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
grandstream ucm6510_firmware Affected: 0 , < 1.0.20.52 (custom)
    cpe:2.3:a:grandstream:ucm6510_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:grandstream:ucm6202_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ucm6202_firmware",
            "vendor": "grandstream",
            "versions": [
              {
                "lessThan": "1.0.20.52",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:grandstream:ucm6204_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ucm6204_firmware",
            "vendor": "grandstream",
            "versions": [
              {
                "lessThan": "1.0.20.52",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:grandstream:ucm6208_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ucm6208_firmware",
            "vendor": "grandstream",
            "versions": [
              {
                "lessThan": "1.0.20.52",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:grandstream:ucm6510_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ucm6510_firmware",
            "vendor": "grandstream",
            "versions": [
              {
                "lessThan": "1.0.20.52",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-0840",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-05-01T19:17:53.854809Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-06T13:09:24.386Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T18:18:18.719Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://vulncheck.com/advisories/grand-stream-param-injection"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "UCM Series",
          "vendor": "Grandstream",
          "versions": [
            {
              "lessThan": "\u003c1.0.20.52",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Jacob Baines (VulnCheck)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "The Grandstream UCM Series IP PBX before firmware version 1.0.20.52 is affected by a parameter injection vulnerability in the HTTP interface. A remote and authenticated attacker can execute arbitrary code by sending a crafted HTTP request. Authentication may be possible using a default user and password. Affected models are the UCM6202, UCM6204, UCM6208, and UCM6510.\u003cbr\u003e"
            }
          ],
          "value": "The Grandstream UCM Series IP PBX before firmware version 1.0.20.52 is affected by a parameter injection vulnerability in the HTTP interface. A remote and authenticated attacker can execute arbitrary code by sending a crafted HTTP request. Authentication may be possible using a default user and password. Affected models are the UCM6202, UCM6204, UCM6208, and UCM6510.\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-137",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-137 Parameter Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-141",
              "description": "CWE-141 Improper Neutralization of Parameter/Argument Delimiters",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-29T18:42:57.112Z",
        "orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
        "shortName": "VulnCheck"
      },
      "references": [
        {
          "url": "https://vulncheck.com/advisories/grand-stream-param-injection"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Upgrade to firmware version 1.0.20.52 or later. Ensure the web interface is not exposed to the internet.\u003cbr\u003e"
            }
          ],
          "value": "Upgrade to firmware version 1.0.20.52 or later. Ensure the web interface is not exposed to the internet.\n"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "timeline": [
        {
          "lang": "en",
          "time": "2024-01-25T17:00:00.000Z",
          "value": "VulnCheck reports the vulnerability to Grandstream"
        },
        {
          "lang": "en",
          "time": "2024-01-26T02:00:00.000Z",
          "value": "Grandstream acknowledges receipt"
        },
        {
          "lang": "en",
          "time": "2024-02-08T04:42:00.000Z",
          "value": "Grandstream shares a patch build"
        },
        {
          "lang": "en",
          "time": "2024-04-26T04:11:00.000Z",
          "value": "Grandstream releases 1.0.20.52"
        }
      ],
      "title": "Grandstream UCM Series IP PBX HTTP Parameter Injection",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
    "assignerShortName": "VulnCheck",
    "cveId": "CVE-2024-0840",
    "datePublished": "2024-04-29T18:42:57.112Z",
    "dateReserved": "2024-01-23T21:10:19.364Z",
    "dateUpdated": "2024-08-01T18:18:18.719Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2024-0840",
      "date": "2026-09-22",
      "epss": "0.0088",
      "percentile": "0.57559"
    },
    "nvd": {
      "cve": {
        "affected": [
          {
            "affectedData": [
              {
                "defaultStatus": "unaffected",
                "product": "UCM Series",
                "vendor": "Grandstream",
                "versions": [
                  {
                    "lessThan": "\u003c1.0.20.52",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "source": "disclosure@vulncheck.com"
          },
          {
            "affectedData": [
              {
                "cpes": [
                  "cpe:2.3:a:grandstream:ucm6202_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "ucm6202_firmware",
                "vendor": "grandstream",
                "versions": [
                  {
                    "lessThan": "1.0.20.52",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:grandstream:ucm6204_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "ucm6204_firmware",
                "vendor": "grandstream",
                "versions": [
                  {
                    "lessThan": "1.0.20.52",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:grandstream:ucm6208_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "ucm6208_firmware",
                "vendor": "grandstream",
                "versions": [
                  {
                    "lessThan": "1.0.20.52",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:grandstream:ucm6510_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "ucm6510_firmware",
                "vendor": "grandstream",
                "versions": [
                  {
                    "lessThan": "1.0.20.52",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "The Grandstream UCM Series IP PBX before firmware version 1.0.20.52 is affected by a parameter injection vulnerability in the HTTP interface. A remote and authenticated attacker can execute arbitrary code by sending a crafted HTTP request. Authentication may be possible using a default user and password. Affected models are the UCM6202, UCM6204, UCM6208, and UCM6510.\n"
          },
          {
            "lang": "es",
            "value": "La central IP Grandstream UCM Series anterior a la versi\u00f3n de firmware 1.0.20.52 se ve afectada por una vulnerabilidad de inyecci\u00f3n de par\u00e1metros en la interfaz HTTP. Un atacante remoto y autenticado puede ejecutar c\u00f3digo arbitrario enviando una solicitud HTTP manipulada. La autenticaci\u00f3n puede ser posible utilizando un usuario y una contrase\u00f1a predeterminados. Los modelos afectados son UCM6202, UCM6204, UCM6208 y UCM6510."
          }
        ],
        "id": "CVE-2024-0840",
        "lastModified": "2026-06-17T06:54:24.887",
        "metrics": {
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 2.8,
              "impactScore": 5.9,
              "source": "disclosure@vulncheck.com",
              "type": "Secondary"
            }
          ],
          "ssvcV203": [
            {
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "ssvcData": {
                "id": "CVE-2024-0840",
                "options": [
                  {
                    "exploitation": "none"
                  },
                  {
                    "automatable": "no"
                  },
                  {
                    "technicalImpact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-05-01T19:17:53.854809Z",
                "version": "2.0.3"
              }
            }
          ]
        },
        "published": "2024-04-29T19:15:19.730",
        "references": [
          {
            "source": "disclosure@vulncheck.com",
            "url": "https://vulncheck.com/advisories/grand-stream-param-injection"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "url": "https://vulncheck.com/advisories/grand-stream-param-injection"
          }
        ],
        "sourceIdentifier": "disclosure@vulncheck.com",
        "vulnStatus": "Deferred",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-141"
              }
            ],
            "source": "disclosure@vulncheck.com",
            "type": "Secondary"
          }
        ]
      }
    },
    "redhat_vex": {
      "current_release_date": "2025-05-28T18:43:58+00:00",
      "cve": "CVE-2024-0840",
      "id": "CVE-2024-0840",
      "initial_release_date": "2024-01-01T00:00:00+00:00",
      "product_status:known_not_affected": "1",
      "source": "Red Hat CSAF VEX",
      "status": "final",
      "title": "Grandstream UCM Series IP PBX HTTP Parameter Injection",
      "url": "https://security.access.redhat.com/data/csaf/v2/vex/2024/cve-2024-0840.json",
      "version": "3"
    },
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-01T18:18:18.719Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://vulncheck.com/advisories/grand-stream-param-injection"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:grandstream:ucm6202_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "ucm6202_firmware",
                "vendor": "grandstream",
                "versions": [
                  {
                    "lessThan": "1.0.20.52",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:grandstream:ucm6204_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "ucm6204_firmware",
                "vendor": "grandstream",
                "versions": [
                  {
                    "lessThan": "1.0.20.52",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:grandstream:ucm6208_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "ucm6208_firmware",
                "vendor": "grandstream",
                "versions": [
                  {
                    "lessThan": "1.0.20.52",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:a:grandstream:ucm6510_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "ucm6510_firmware",
                "vendor": "grandstream",
                "versions": [
                  {
                    "lessThan": "1.0.20.52",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-0840",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-05-01T19:17:53.854809Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-05-01T19:13:22.175Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "UCM Series",
              "vendor": "Grandstream",
              "versions": [
                {
                  "lessThan": "\u003c1.0.20.52",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Jacob Baines (VulnCheck)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "The Grandstream UCM Series IP PBX before firmware version 1.0.20.52 is affected by a parameter injection vulnerability in the HTTP interface. A remote and authenticated attacker can execute arbitrary code by sending a crafted HTTP request. Authentication may be possible using a default user and password. Affected models are the UCM6202, UCM6204, UCM6208, and UCM6510.\u003cbr\u003e"
                }
              ],
              "value": "The Grandstream UCM Series IP PBX before firmware version 1.0.20.52 is affected by a parameter injection vulnerability in the HTTP interface. A remote and authenticated attacker can execute arbitrary code by sending a crafted HTTP request. Authentication may be possible using a default user and password. Affected models are the UCM6202, UCM6204, UCM6208, and UCM6510.\n"
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-137",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-137 Parameter Injection"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-141",
                  "description": "CWE-141 Improper Neutralization of Parameter/Argument Delimiters",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-04-29T18:42:57.112Z",
            "orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
            "shortName": "VulnCheck"
          },
          "references": [
            {
              "url": "https://vulncheck.com/advisories/grand-stream-param-injection"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Upgrade to firmware version 1.0.20.52 or later. Ensure the web interface is not exposed to the internet.\u003cbr\u003e"
                }
              ],
              "value": "Upgrade to firmware version 1.0.20.52 or later. Ensure the web interface is not exposed to the internet.\n"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "timeline": [
            {
              "lang": "en",
              "time": "2024-01-25T17:00:00.000Z",
              "value": "VulnCheck reports the vulnerability to Grandstream"
            },
            {
              "lang": "en",
              "time": "2024-01-26T02:00:00.000Z",
              "value": "Grandstream acknowledges receipt"
            },
            {
              "lang": "en",
              "time": "2024-02-08T04:42:00.000Z",
              "value": "Grandstream shares a patch build"
            },
            {
              "lang": "en",
              "time": "2024-04-26T04:11:00.000Z",
              "value": "Grandstream releases 1.0.20.52"
            }
          ],
          "title": "Grandstream UCM Series IP PBX HTTP Parameter Injection",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
        "assignerShortName": "VulnCheck",
        "cveId": "CVE-2024-0840",
        "datePublished": "2024-04-29T18:42:57.112Z",
        "dateReserved": "2024-01-23T21:10:19.364Z",
        "dateUpdated": "2024-08-01T18:18:18.719Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…