CVE-2023-43744 (GCVE-0-2023-43744)
Vulnerability from cvelistv5 – Published: 2023-12-08 00:00 – Updated: 2024-08-02 19:52
VLAI?
Summary
An OS command injection vulnerability in Zultys MX-SE, MX-SE II, MX-E, MX-Virtual, MX250, and MX30 with firmware versions prior to 17.0.10 patch 17161 and 16.04 patch 16109 allows an administrator to execute arbitrary OS commands via a file name parameter in a patch application function. The Zultys MX Administrator client has a "Patch Manager" section that allows administrators to apply patches to the device. The user supplied filename for the patch file is passed to a shell script without validation. Including bash command substitution characters in a patch file name results in execution of the provided command.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
2 references
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T19:52:10.930Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://mxvirtual.com"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/atredispartners/advisories/blob/master/ATREDIS-2023-0002.md"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An OS command injection vulnerability in Zultys MX-SE, MX-SE II, MX-E, MX-Virtual, MX250, and MX30 with firmware versions prior to 17.0.10 patch 17161 and 16.04 patch 16109 allows an administrator to execute arbitrary OS commands via a file name parameter in a patch application function. The Zultys MX Administrator client has a \"Patch Manager\" section that allows administrators to apply patches to the device. The user supplied filename for the patch file is passed to a shell script without validation. Including bash command substitution characters in a patch file name results in execution of the provided command."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-12-08T01:08:19.524Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://mxvirtual.com"
},
{
"url": "https://github.com/atredispartners/advisories/blob/master/ATREDIS-2023-0002.md"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2023-43744",
"datePublished": "2023-12-08T00:00:00.000Z",
"dateReserved": "2023-09-22T00:00:00.000Z",
"dateUpdated": "2024-08-02T19:52:10.930Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2023-43744",
"date": "2026-05-15",
"epss": "0.00186",
"percentile": "0.40139"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2023-43744\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2023-12-08T01:15:07.337\",\"lastModified\":\"2024-11-21T08:24:42.310\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"An OS command injection vulnerability in Zultys MX-SE, MX-SE II, MX-E, MX-Virtual, MX250, and MX30 with firmware versions prior to 17.0.10 patch 17161 and 16.04 patch 16109 allows an administrator to execute arbitrary OS commands via a file name parameter in a patch application function. The Zultys MX Administrator client has a \\\"Patch Manager\\\" section that allows administrators to apply patches to the device. The user supplied filename for the patch file is passed to a shell script without validation. Including bash command substitution characters in a patch file name results in execution of the provided command.\"},{\"lang\":\"es\",\"value\":\"Una vulnerabilidad de inyecci\u00f3n de comandos del sistema operativo en Zultys MX-SE, MX-SE II, MX-E, MX-Virtual, MX250 y MX30 con versiones de firmware anteriores al parche 17.0.10 17161 y al parche 16.04 16109 permite a un administrador ejecutar comandos arbitrarios del sistema operativo. a trav\u00e9s de un par\u00e1metro de nombre de archivo en una funci\u00f3n de aplicaci\u00f3n de parche. El cliente Zultys MX Administrator tiene una secci\u00f3n \\\"Administrador de parches\\\" que permite a los administradores aplicar parches al dispositivo. El nombre de archivo proporcionado por el usuario para el archivo de parche se pasa a un script de shell sin validaci\u00f3n. Incluir caracteres de sustituci\u00f3n de comandos bash en el nombre de un archivo de parche da como resultado la ejecuci\u00f3n del comando proporcionado.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.2,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.2,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-78\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:zultys:mx-se_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"16.0.4\",\"matchCriteriaId\":\"09D39AC9-ACBA-4CF9-B9F0-D04F6B392905\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:zultys:mx-se_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"17.0.6\",\"versionEndExcluding\":\"17.0.10\",\"matchCriteriaId\":\"4D290A1E-9CF3-42C3-B099-9A0D5FFE2FDC\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:zultys:mx-se:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B8E4DCA4-D3CB-46DC-B20F-205F18FE6FA4\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:zultys:mx-se_ii_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"16.0.4\",\"matchCriteriaId\":\"E2CE4D4C-0CB5-4AB9-936B-E275E4A6E1A1\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:zultys:mx-se_ii_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"17.0.6\",\"versionEndExcluding\":\"17.0.10\",\"matchCriteriaId\":\"9B040E08-BAF8-475B-BF5C-DC3D6D5FBBB1\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:zultys:mx-se_ii:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6DD550DD-C5C0-4ABC-9C29-016FC0587E97\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:zultys:mx-e_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"16.0.4\",\"matchCriteriaId\":\"3907F8B7-CB24-4BE4-8B8D-18F3D965EE7C\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:zultys:mx-e_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"17.0.6\",\"versionEndExcluding\":\"17.0.10\",\"matchCriteriaId\":\"2257C4EE-4C6F-4EC2-A88D-6048FFE28EC2\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:zultys:mx-e:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2E12E140-C7D8-4875-9AF7-4EF1A77D9CF1\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:zultys:mx-virtual_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"16.0.4\",\"matchCriteriaId\":\"BCCC65F2-DAC8-4A47-A712-95D7E2579A3B\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:zultys:mx-virtual_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"17.0.6\",\"versionEndExcluding\":\"17.0.10\",\"matchCriteriaId\":\"7657BBD9-09D8-4EEA-AC0B-5098C4369874\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:zultys:mx-virtual:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"3B765CFE-8D05-430C-9725-6FBC8C9D1484\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:zultys:mx250_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"16.0.4\",\"matchCriteriaId\":\"9D49E46A-4BA6-4563-9786-D2BC5E05F1CE\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:zultys:mx250_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"17.0.6\",\"versionEndExcluding\":\"17.0.10\",\"matchCriteriaId\":\"B9572474-24A5-47C5-9A95-E8F4E0AB56C8\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:zultys:mx250:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"44FBBEC0-96AF-42D1-B27C-91E6F3E67F7D\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:zultys:mx30_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"16.0.4\",\"matchCriteriaId\":\"AF02FDBD-C0B9-4E6D-AEDD-3BB28D9EF059\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:zultys:mx30_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"17.0.6\",\"versionEndExcluding\":\"17.0.10\",\"matchCriteriaId\":\"6EC94AF4-0D2B-4045-98DF-53E2014C139D\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:zultys:mx30:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"45765B6E-39CE-4CD2-A20C-7DB96FDDEBF0\"}]}]}],\"references\":[{\"url\":\"https://github.com/atredispartners/advisories/blob/master/ATREDIS-2023-0002.md\",\"source\":\"cve@mitre.org\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://mxvirtual.com\",\"source\":\"cve@mitre.org\",\"tags\":[\"Product\"]},{\"url\":\"https://github.com/atredispartners/advisories/blob/master/ATREDIS-2023-0002.md\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://mxvirtual.com\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Product\"]}]}}"
}
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…