CVE-2023-41960 (GCVE-0-2023-41960)

Vulnerability from cvelistv5 – Published: 2023-10-25 14:12 – Updated: 2024-09-12 14:29
VLAI
Summary
The vulnerability allows an unprivileged(untrusted) third-party application to interact with a content-provider unsafely exposed by the Android Agent application, potentially modifying sensitive settings of the Android Client application itself.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-09-10 19:00 UTC
CWE
  • CWE-926 - Improper Export of Android Application Components
Assigner
bosch CNA under the icscert root
CNA scorecard – unranked: 8 records in the last 180 days, 10 needed details
References
Impacted products
Vendor Product Version CPE status
Rexroth ctrlX HMI Web Panel - WR21 (WR2107) Affected: all
guessed Create a notification for this product.
Rexroth ctrlX HMI Web Panel - WR21 (WR2110) Affected: all
guessed Create a notification for this product.
Rexroth ctrlX HMI Web Panel - WR21 (WR2115) Affected: all
guessed Create a notification for this product.
boschrexroth ctrlx_hmi_web_panel_wr2107 Affected: 0 , < * (custom)
    cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2107:-:*:*:*:*:*:*:*
Create a notification for this product.
boschrexroth ctrlx_hmi_web_panel_wr2110 Affected: 0 , < * (custom)
    cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2110:-:*:*:*:*:*:*:*
Create a notification for this product.
boschrexroth ctrlx_hmi_web_panel_wr2115 Affected: 0 , < * (custom)
    cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2115:-:*:*:*:*:*:*:*
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T19:09:49.389Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html",
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2107:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ctrlx_hmi_web_panel_wr2107",
            "vendor": "boschrexroth",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2110:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ctrlx_hmi_web_panel_wr2110",
            "vendor": "boschrexroth",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2115:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ctrlx_hmi_web_panel_wr2115",
            "vendor": "boschrexroth",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-41960",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-09-10T19:00:56.501041Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-09-12T14:29:20.687Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "ctrlX HMI Web Panel - WR21 (WR2107)",
          "vendor": "Rexroth",
          "versions": [
            {
              "status": "affected",
              "version": "all"
            }
          ]
        },
        {
          "product": "ctrlX HMI Web Panel - WR21 (WR2110)",
          "vendor": "Rexroth",
          "versions": [
            {
              "status": "affected",
              "version": "all"
            }
          ]
        },
        {
          "product": "ctrlX HMI Web Panel - WR21 (WR2115)",
          "vendor": "Rexroth",
          "versions": [
            {
              "status": "affected",
              "version": "all"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "The vulnerability allows an unprivileged(untrusted) third-party application to interact with a content-provider unsafely exposed by the Android Agent application, potentially modifying sensitive settings of the Android Client application itself."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-926",
              "description": "CWE-926 Improper Export of Android Application Components",
              "lang": "en-US"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-10-25T14:12:08.722Z",
        "orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
        "shortName": "bosch"
      },
      "references": [
        {
          "name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html",
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
    "assignerShortName": "bosch",
    "cveId": "CVE-2023-41960",
    "datePublished": "2023-10-25T14:12:08.722Z",
    "dateReserved": "2023-10-18T09:35:22.502Z",
    "dateUpdated": "2024-09-12T14:29:20.687Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2023-41960",
      "date": "2026-11-14",
      "epss": "0.00205",
      "percentile": "0.10637"
    },
    "nvd": {
      "cve": {
        "affected": [
          {
            "affectedData": [
              {
                "product": "ctrlX HMI Web Panel - WR21 (WR2107)",
                "vendor": "Rexroth",
                "versions": [
                  {
                    "status": "affected",
                    "version": "all"
                  }
                ]
              },
              {
                "product": "ctrlX HMI Web Panel - WR21 (WR2110)",
                "vendor": "Rexroth",
                "versions": [
                  {
                    "status": "affected",
                    "version": "all"
                  }
                ]
              },
              {
                "product": "ctrlX HMI Web Panel - WR21 (WR2115)",
                "vendor": "Rexroth",
                "versions": [
                  {
                    "status": "affected",
                    "version": "all"
                  }
                ]
              }
            ],
            "source": "psirt@bosch.com"
          },
          {
            "affectedData": [
              {
                "cpes": [
                  "cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2107:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "ctrlx_hmi_web_panel_wr2107",
                "vendor": "boschrexroth",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2110:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "ctrlx_hmi_web_panel_wr2110",
                "vendor": "boschrexroth",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2115:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "ctrlx_hmi_web_panel_wr2115",
                "vendor": "boschrexroth",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"
          }
        ],
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:boschrexroth:ctrlx_hmi_web_panel_wr2107_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "7FFA1309-DBEE-46F1-B6FD-DAE896180411",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2107:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "87C129B8-F100-4D3A-97BC-BAD9A4129F9D",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:boschrexroth:ctrlx_hmi_web_panel_wr2110_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "FD47D2E3-F53F-4CE8-BEF7-76F78AEBAF5C",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2110:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "326E80AA-C9B4-4BF1-AA2B-98A3802A72C9",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:boschrexroth:ctrlx_hmi_web_panel_wr2115_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "4CA92486-EEBE-42FD-9755-006B7F2DF361",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2115:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "167C9BC4-FCC5-4FAF-8F75-F967C77400A7",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "The vulnerability allows an unprivileged(untrusted) third-party application to interact with a content-provider unsafely exposed by the Android Agent application, potentially modifying sensitive settings of the Android Client application itself."
          },
          {
            "lang": "es",
            "value": "La vulnerabilidad permite que una aplicaci\u00f3n de terceros sin privilegios (no confiable) interact\u00fae con un proveedor de contenido expuesto de manera insegura por la aplicaci\u00f3n del Agente de Android, modificando potencialmente configuraciones confidenciales de la propia aplicaci\u00f3n del Cliente de Android."
          }
        ],
        "id": "CVE-2023-41960",
        "lastModified": "2026-06-17T06:23:08.933",
        "metrics": {
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.1,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 1.8,
              "impactScore": 5.2,
              "source": "psirt@bosch.com",
              "type": "Secondary"
            },
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "NONE",
                "baseScore": 3.3,
                "baseSeverity": "LOW",
                "confidentialityImpact": "NONE",
                "integrityImpact": "LOW",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N",
                "version": "3.1"
              },
              "exploitabilityScore": 1.8,
              "impactScore": 1.4,
              "source": "nvd@nist.gov",
              "type": "Primary"
            }
          ],
          "ssvcV203": [
            {
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "ssvcData": {
                "id": "CVE-2023-41960",
                "options": [
                  {
                    "exploitation": "none"
                  },
                  {
                    "automatable": "no"
                  },
                  {
                    "technicalImpact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-09-10T19:00:56.501041Z",
                "version": "2.0.3"
              }
            }
          ]
        },
        "published": "2023-10-25T18:17:31.037",
        "references": [
          {
            "source": "psirt@bosch.com",
            "tags": [
              "Mitigation",
              "Vendor Advisory"
            ],
            "url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Mitigation",
              "Vendor Advisory"
            ],
            "url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html"
          }
        ],
        "sourceIdentifier": "psirt@bosch.com",
        "vulnStatus": "Modified",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-926"
              }
            ],
            "source": "psirt@bosch.com",
            "type": "Secondary"
          },
          {
            "description": [
              {
                "lang": "en",
                "value": "NVD-CWE-Other"
              }
            ],
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      }
    },
    "redhat_vex": {
      "current_release_date": "2025-05-29T00:20:56+00:00",
      "cve": "CVE-2023-41960",
      "id": "CVE-2023-41960",
      "initial_release_date": "2023-01-01T00:00:00+00:00",
      "product_status:known_not_affected": "1",
      "source": "Red Hat CSAF VEX",
      "status": "final",
      "title": "CVE-2023-41960",
      "url": "https://security.access.redhat.com/data/csaf/v2/vex/2023/cve-2023-41960.json",
      "version": "3"
    },
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T19:09:49.389Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html",
                "tags": [
                  "vendor-advisory",
                  "x_transferred"
                ],
                "url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2107:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "ctrlx_hmi_web_panel_wr2107",
                "vendor": "boschrexroth",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2110:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "ctrlx_hmi_web_panel_wr2110",
                "vendor": "boschrexroth",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2115:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "ctrlx_hmi_web_panel_wr2115",
                "vendor": "boschrexroth",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-41960",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-09-10T19:00:56.501041Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-09-10T19:03:04.325Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "ctrlX HMI Web Panel - WR21 (WR2107)",
              "vendor": "Rexroth",
              "versions": [
                {
                  "status": "affected",
                  "version": "all"
                }
              ]
            },
            {
              "product": "ctrlX HMI Web Panel - WR21 (WR2110)",
              "vendor": "Rexroth",
              "versions": [
                {
                  "status": "affected",
                  "version": "all"
                }
              ]
            },
            {
              "product": "ctrlX HMI Web Panel - WR21 (WR2115)",
              "vendor": "Rexroth",
              "versions": [
                {
                  "status": "affected",
                  "version": "all"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "The vulnerability allows an unprivileged(untrusted) third-party application to interact with a content-provider unsafely exposed by the Android Agent application, potentially modifying sensitive settings of the Android Client application itself."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.1,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-926",
                  "description": "CWE-926 Improper Export of Android Application Components",
                  "lang": "en-US"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-10-25T14:12:08.722Z",
            "orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
            "shortName": "bosch"
          },
          "references": [
            {
              "name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html",
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
        "assignerShortName": "bosch",
        "cveId": "CVE-2023-41960",
        "datePublished": "2023-10-25T14:12:08.722Z",
        "dateReserved": "2023-10-18T09:35:22.502Z",
        "dateUpdated": "2024-09-12T14:29:20.687Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline

Sightings and recorded dates, grouped by day · UTC

JSON
How durations are calculated

Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.

Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.

Events included in the timeline

Loading timeline…


    Loading…

    Loading…

    Loading…

    Related by attack behaviour

    Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.