CVE-2023-28062 (GCVE-0-2023-28062)
Vulnerability from cvelistv5 – Published: 2023-04-11 13:55 – Updated: 2025-02-07 16:30
VLAI?
Summary
Dell PPDM versions 19.12, 19.11 and 19.10, contain an improper access control vulnerability. A remote authenticated malicious user with low privileges could potentially exploit this vulnerability to bypass intended access restrictions and perform unauthorized actions.
Severity ?
8.8 (High)
CWE
- CWE-648 - Incorrect Use of Privileged APIs
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | PPDM Reporting (PowerProtect Data Manager) |
Affected:
19.10, 19.11 and 19.12
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T12:30:23.628Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000212242/dsa-2023-137-dell-powerprotect-data-manager-security-update-for-proprietary-code-vulnerability"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-28062",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-07T16:30:28.845773Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-07T16:30:36.177Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PPDM Reporting (PowerProtect Data Manager)",
"vendor": "Dell",
"versions": [
{
"status": "affected",
"version": "19.10, 19.11 and 19.12"
}
]
}
],
"datePublic": "2023-04-11T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDell PPDM versions 19.12, 19.11 and 19.10, contain an improper access control vulnerability. A remote authenticated malicious user with low privileges could potentially exploit this vulnerability to bypass intended access restrictions and perform unauthorized actions.\u003c/span\u003e\n\n"
}
],
"value": "\nDell PPDM versions 19.12, 19.11 and 19.10, contain an improper access control vulnerability. A remote authenticated malicious user with low privileges could potentially exploit this vulnerability to bypass intended access restrictions and perform unauthorized actions.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-648",
"description": "CWE-648: Incorrect Use of Privileged APIs",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-04-11T13:55:40.618Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000212242/dsa-2023-137-dell-powerprotect-data-manager-security-update-for-proprietary-code-vulnerability"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2023-28062",
"datePublished": "2023-04-11T13:55:40.618Z",
"dateReserved": "2023-03-10T05:06:06.441Z",
"dateUpdated": "2025-02-07T16:30:36.177Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"nvd": "{\"cve\":{\"id\":\"CVE-2023-28062\",\"sourceIdentifier\":\"security_alert@emc.com\",\"published\":\"2023-04-11T14:15:07.710\",\"lastModified\":\"2024-11-21T07:54:18.940\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"\\nDell PPDM versions 19.12, 19.11 and 19.10, contain an improper access control vulnerability. A remote authenticated malicious user with low privileges could potentially exploit this vulnerability to bypass intended access restrictions and perform unauthorized actions.\\n\\n\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"security_alert@emc.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.9},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"security_alert@emc.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-648\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-Other\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:dell:powerprotect_data_manager:19.10:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"34130ADE-3AE2-4361-AB55-804AB1345670\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:dell:powerprotect_data_manager:19.11:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"9359611A-8438-4D2E-AEC3-9F1C747755A4\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:dell:powerprotect_data_manager:19.12:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6561482F-D852-4D74-8680-F55CF841E4F8\"}]}]}],\"references\":[{\"url\":\"https://www.dell.com/support/kbdoc/en-us/000212242/dsa-2023-137-dell-powerprotect-data-manager-security-update-for-proprietary-code-vulnerability\",\"source\":\"security_alert@emc.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.dell.com/support/kbdoc/en-us/000212242/dsa-2023-137-dell-powerprotect-data-manager-security-update-for-proprietary-code-vulnerability\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://www.dell.com/support/kbdoc/en-us/000212242/dsa-2023-137-dell-powerprotect-data-manager-security-update-for-proprietary-code-vulnerability\", \"tags\": [\"vendor-advisory\", \"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-02T12:30:23.628Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2023-28062\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-02-07T16:30:28.845773Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-02-07T16:30:14.556Z\"}}], \"cna\": {\"source\": {\"discovery\": \"UNKNOWN\"}, \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 8.8, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"LOW\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Dell\", \"product\": \"PPDM Reporting (PowerProtect Data Manager)\", \"versions\": [{\"status\": \"affected\", \"version\": \"19.10, 19.11 and 19.12\"}], \"defaultStatus\": \"unaffected\"}], \"datePublic\": \"2023-04-11T06:30:00.000Z\", \"references\": [{\"url\": \"https://www.dell.com/support/kbdoc/en-us/000212242/dsa-2023-137-dell-powerprotect-data-manager-security-update-for-proprietary-code-vulnerability\", \"tags\": [\"vendor-advisory\"]}], \"x_generator\": {\"engine\": \"Vulnogram 0.1.0-dev\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"\\nDell PPDM versions 19.12, 19.11 and 19.10, contain an improper access control vulnerability. A remote authenticated malicious user with low privileges could potentially exploit this vulnerability to bypass intended access restrictions and perform unauthorized actions.\\n\\n\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\\n\\n\u003cspan style=\\\"background-color: rgb(255, 255, 255);\\\"\u003eDell PPDM versions 19.12, 19.11 and 19.10, contain an improper access control vulnerability. A remote authenticated malicious user with low privileges could potentially exploit this vulnerability to bypass intended access restrictions and perform unauthorized actions.\u003c/span\u003e\\n\\n\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-648\", \"description\": \"CWE-648: Incorrect Use of Privileged APIs\"}]}], \"providerMetadata\": {\"orgId\": \"c550e75a-17ff-4988-97f0-544cde3820fe\", \"shortName\": \"dell\", \"dateUpdated\": \"2023-04-11T13:55:40.618Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2023-28062\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-02-07T16:30:36.177Z\", \"dateReserved\": \"2023-03-10T05:06:06.441Z\", \"assignerOrgId\": \"c550e75a-17ff-4988-97f0-544cde3820fe\", \"datePublished\": \"2023-04-11T13:55:40.618Z\", \"assignerShortName\": \"dell\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…