CVE-2023-2310 (GCVE-0-2023-2310)

Vulnerability from cvelistv5 – Published: 2023-05-10 19:18 – Updated: 2025-01-27 18:20
VLAI
Title
Channel Accessible by Non-Endpoint
Summary
A Channel Accessible by Non-Endpoint vulnerability in the Schweitzer Engineering Laboratories SEL Real-Time Automation Controller (RTAC) could allow a remote attacker to perform a man-in-the-middle (MiTM) that could result in denial of service. See the ACSELERATOR RTAC SEL-5033 Software instruction manual date code 20210915 for more details.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-01-27 18:20 UTC
CWE
  • CWE-300 - Channel Accessible by Non-Endpoint
Impacted products
Vendor Product Version CPE status
Schweitzer Engineering Laboratories SEL-3505 Affected: R119-V0 , < R150-V2 (custom)
Affected: R119-V0 , < R149-V4 (custom)
Affected: R119-V0 , < R148-V7 (custom)
Affected: R119-V0 , < R147-V6 (custom)
guessed Create a notification for this product.
Schweitzer Engineering Laboratories, Inc. SEL-3505-3 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
guessed Create a notification for this product.
Schweitzer Engineering Laboratories SEL-3530 Affected: R100-V0 , < R150-V2 (custom)
Affected: R100-V0 , < R149-V4 (custom)
Affected: R100-V0 , < R148-V7 (custom)
Affected: R100-V0 , < R147-V6 (custom)
guessed Create a notification for this product.
Schweitzer Engineering Laboratories, Inc. SEL-3530-4 Affected: R108-V0 , < R150-V2 (custom)
Affected: R108-V0 , < R149-V4 (custom)
Affected: R108-V0 , < R148-V7 (custom)
Affected: R108-V0 , < R147-V6 (custom)
guessed Create a notification for this product.
Schweitzer Engineering Laboratories, Inc. SEL-3532 Affected: R132-V0 , < R150-V2 (custom)
Affected: R132-V0 , < R149-V4 (custom)
Affected: R132-V0 , < R148-V7 (custom)
Affected: R132-V0 , < R147-V6 (custom)
guessed Create a notification for this product.
Schweitzer Engineering Laboratories, Inc. SEL-3555 Affected: R134-V0 , < R150-V2 (custom)
Affected: R134-V0 , < R149-V4 (custom)
Affected: R134-V0 , < R148-V7 (custom)
Affected: R134-V0 , < R147-V6 (custom)
guessed Create a notification for this product.
Schweitzer Engineering Laboratories, Inc. SEL-3560S Affected: R144-V2 , < R150-V2 (custom)
Affected: R144-V2 , < R149-V4 (custom)
Affected: R144-V2 , < R148-V7 (custom)
Affected: R144-V2 , < R147-V6 (custom)
guessed Create a notification for this product.
Schweitzer Engineering Laboratories, Inc. SEL-3560E Affected: R144-V2 , < R150-V2 (custom)
Affected: R144-V2 , < R149-V4 (custom)
Affected: R144-V2 , < R148-V7 (custom)
Affected: R144-V2 , < R147-V6 (custom)
guessed Create a notification for this product.
Schweitzer Engineering Laboratories, Inc. SEL-2241 RTAC module Affected: R113-V0 , < R150-V2 (custom)
Affected: R113-V0 , < R149-V4 (custom)
Affected: R113-V0 , < R148-V7 (custom)
Affected: R113-V0 , < R147-V6 (custom)
guessed Create a notification for this product.
Schweitzer Engineering Laboratories, Inc. SEL-3350 Affected: R148-V0 , < R150-V2 (custom)
Affected: R148-V0 , < R149-V4 (custom)
Affected: R148-V0 , < R148-V7 (custom)
guessed Create a notification for this product.
Date Public
2023-05-10 07:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T06:19:14.854Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://selinc.com/support/security-notifications/external-reports/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-2310",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-27T18:20:24.063475Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-27T18:20:35.192Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3505",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R119-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R119-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R119-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R119-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3505-3",
          "vendor": "Schweitzer Engineering Laboratories, Inc.",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3530",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R100-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R100-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R100-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R100-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3530-4",
          "vendor": "Schweitzer Engineering Laboratories, Inc.",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R108-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R108-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R108-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R108-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3532",
          "vendor": "Schweitzer Engineering Laboratories, Inc.",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R132-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3555",
          "vendor": "Schweitzer Engineering Laboratories, Inc.",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R134-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3560S",
          "vendor": "Schweitzer Engineering Laboratories, Inc.",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3560E",
          "vendor": "Schweitzer Engineering Laboratories, Inc.",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R144-V2",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "Linux"
          ],
          "product": "SEL-2241 RTAC module",
          "vendor": "Schweitzer Engineering Laboratories, Inc.",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R113-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R113-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R113-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R147-V6",
              "status": "affected",
              "version": "R113-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "Linux"
          ],
          "product": "SEL-3350",
          "vendor": "Schweitzer Engineering Laboratories, Inc.",
          "versions": [
            {
              "lessThan": "R150-V2",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R149-V4",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R148-V7",
              "status": "affected",
              "version": "R148-V0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Adeen Ayub, Syed Ali Qasim, Irfan Ahmed, Virginia Commonwealth University"
        }
      ],
      "datePublic": "2023-05-10T07:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A Channel Accessible by Non-Endpoint vulnerability in the Schweitzer Engineering Laboratories SEL Real-Time Automation Controller (RTAC) could allow a remote attacker to perform a man-in-the-middle (MiTM) that could result in denial of service.\u003cbr\u003e\u003cbr\u003eSee the ACSELERATOR RTAC SEL-5033 Software instruction manual date code 20210915 for more details."
            }
          ],
          "value": "A Channel Accessible by Non-Endpoint vulnerability in the Schweitzer Engineering Laboratories SEL Real-Time Automation Controller (RTAC) could allow a remote attacker to perform a man-in-the-middle (MiTM) that could result in denial of service.\n\nSee the ACSELERATOR RTAC SEL-5033 Software instruction manual date code 20210915 for more details."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-469",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-469 DoS"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:N/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-300",
              "description": "CWE-300 Channel Accessible by Non-Endpoint",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-05-10T19:18:43.806Z",
        "orgId": "5804bb70-792c-43e0-8596-486cc0efe699",
        "shortName": "SEL"
      },
      "references": [
        {
          "url": "https://selinc.com/support/security-notifications/external-reports/"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Channel Accessible by Non-Endpoint",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "5804bb70-792c-43e0-8596-486cc0efe699",
    "assignerShortName": "SEL",
    "cveId": "CVE-2023-2310",
    "datePublished": "2023-05-10T19:18:43.806Z",
    "dateReserved": "2023-04-26T18:25:33.932Z",
    "dateUpdated": "2025-01-27T18:20:35.192Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2023-2310",
      "date": "2026-09-26",
      "epss": "0.005",
      "percentile": "0.40354"
    },
    "nvd": {
      "cve": {
        "affected": [
          {
            "affectedData": [
              {
                "defaultStatus": "unaffected",
                "platforms": [
                  "Linux"
                ],
                "product": "SEL-3505",
                "vendor": "Schweitzer Engineering Laboratories",
                "versions": [
                  {
                    "lessThan": "R150-V2",
                    "status": "affected",
                    "version": "R119-V0",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "R149-V4",
                    "status": "affected",
                    "version": "R119-V0",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "R148-V7",
                    "status": "affected",
                    "version": "R119-V0",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "R147-V6",
                    "status": "affected",
                    "version": "R119-V0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "platforms": [
                  "Linux"
                ],
                "product": "SEL-3505-3",
                "vendor": "Schweitzer Engineering Laboratories, Inc.",
                "versions": [
                  {
                    "lessThan": "R150-V2",
                    "status": "affected",
                    "version": "R132-V0",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "R149-V4",
                    "status": "affected",
                    "version": "R132-V0",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "R148-V7",
                    "status": "affected",
                    "version": "R132-V0",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "R147-V6",
                    "status": "affected",
                    "version": "R132-V0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "platforms": [
                  "Linux"
                ],
                "product": "SEL-3530",
                "vendor": "Schweitzer Engineering Laboratories",
                "versions": [
                  {
                    "lessThan": "R150-V2",
                    "status": "affected",
                    "version": "R100-V0",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "R149-V4",
                    "status": "affected",
                    "version": "R100-V0",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "R148-V7",
                    "status": "affected",
                    "version": "R100-V0",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "R147-V6",
                    "status": "affected",
                    "version": "R100-V0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "platforms": [
                  "Linux"
                ],
                "product": "SEL-3530-4",
                "vendor": "Schweitzer Engineering Laboratories, Inc.",
                "versions": [
                  {
                    "lessThan": "R150-V2",
                    "status": "affected",
                    "version": "R108-V0",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "R149-V4",
                    "status": "affected",
                    "version": "R108-V0",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "R148-V7",
                    "status": "affected",
                    "version": "R108-V0",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "R147-V6",
                    "status": "affected",
                    "version": "R108-V0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "platforms": [
                  "Linux"
                ],
                "product": "SEL-3532",
                "vendor": "Schweitzer Engineering Laboratories, Inc.",
                "versions": [
                  {
                    "lessThan": "R150-V2",
                    "status": "affected",
                    "version": "R132-V0",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "R149-V4",
                    "status": "affected",
                    "version": "R132-V0",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "R148-V7",
                    "status": "affected",
                    "version": "R132-V0",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "R147-V6",
                    "status": "affected",
                    "version": "R132-V0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "platforms": [
                  "Linux"
                ],
                "product": "SEL-3555",
                "vendor": "Schweitzer Engineering Laboratories, Inc.",
                "versions": [
                  {
                    "lessThan": "R150-V2",
                    "status": "affected",
                    "version": "R134-V0",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "R149-V4",
                    "status": "affected",
                    "version": "R134-V0",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "R148-V7",
                    "status": "affected",
                    "version": "R134-V0",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "R147-V6",
                    "status": "affected",
                    "version": "R134-V0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "platforms": [
                  "Linux"
                ],
                "product": "SEL-3560S",
                "vendor": "Schweitzer Engineering Laboratories, Inc.",
                "versions": [
                  {
                    "lessThan": "R150-V2",
                    "status": "affected",
                    "version": "R144-V2",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "R149-V4",
                    "status": "affected",
                    "version": "R144-V2",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "R148-V7",
                    "status": "affected",
                    "version": "R144-V2",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "R147-V6",
                    "status": "affected",
                    "version": "R144-V2",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "platforms": [
                  "Linux"
                ],
                "product": "SEL-3560E",
                "vendor": "Schweitzer Engineering Laboratories, Inc.",
                "versions": [
                  {
                    "lessThan": "R150-V2",
                    "status": "affected",
                    "version": "R144-V2",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "R149-V4",
                    "status": "affected",
                    "version": "R144-V2",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "R148-V7",
                    "status": "affected",
                    "version": "R144-V2",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "R147-V6",
                    "status": "affected",
                    "version": "R144-V2",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "platforms": [
                  "Linux"
                ],
                "product": "SEL-2241 RTAC module",
                "vendor": "Schweitzer Engineering Laboratories, Inc.",
                "versions": [
                  {
                    "lessThan": "R150-V2",
                    "status": "affected",
                    "version": "R113-V0",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "R149-V4",
                    "status": "affected",
                    "version": "R113-V0",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "R148-V7",
                    "status": "affected",
                    "version": "R113-V0",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "R147-V6",
                    "status": "affected",
                    "version": "R113-V0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "platforms": [
                  "Linux"
                ],
                "product": "SEL-3350",
                "vendor": "Schweitzer Engineering Laboratories, Inc.",
                "versions": [
                  {
                    "lessThan": "R150-V2",
                    "status": "affected",
                    "version": "R148-V0",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "R149-V4",
                    "status": "affected",
                    "version": "R148-V0",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "R148-V7",
                    "status": "affected",
                    "version": "R148-V0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "source": "security@selinc.com"
          }
        ],
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:selinc:sel-2241_rtac_module_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "92EC2190-5E06-429E-A06A-76571E7ED430",
                    "versionEndExcluding": "r150-v2",
                    "versionStartIncluding": "r113-v0",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:selinc:sel-2241_rtac_module:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "FE4A1AB9-1190-4620-BF97-4A5569E74310",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:selinc:sel-3350_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "490EC90A-C8C4-4AEA-90E8-DA1C6D11932C",
                    "versionEndExcluding": "r150-v2",
                    "versionStartIncluding": "r148-v0",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:selinc:sel-3350:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "FCA7F410-7F74-4EF1-913E-7B34674716DC",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:selinc:sel-3505_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "2161BCBC-6892-47E6-9A9F-0A82F0AA6A92",
                    "versionEndExcluding": "r150-v2",
                    "versionStartIncluding": "r119-v0",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:selinc:sel-3505:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "14D78E73-46F2-4D00-A75B-909752E36EB4",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:selinc:sel-3505-3_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "39E788ED-56DC-455E-B907-9DA7ED359CB9",
                    "versionEndExcluding": "r150-v2",
                    "versionStartIncluding": "r132-v0",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:selinc:sel-3505-3:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "8A479C2B-F691-4E04-B551-9F631E5A2A0F",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:selinc:sel-3530_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "4A438B8C-AD18-47F5-94BF-2484D778EA75",
                    "versionEndExcluding": "r150-v2",
                    "versionStartIncluding": "r100-v0",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:selinc:sel-3530:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "8E56BC08-9C49-4614-8F52-3413B804A128",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:selinc:sel-3530-4_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "C48D1C36-0F34-4A95-88E2-B69DE8803AF7",
                    "versionEndExcluding": "r150-v2",
                    "versionStartIncluding": "r108-v0",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:selinc:sel-3530-4:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "BB424E1B-2AE3-449E-9AA1-2AF48C1920FB",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:selinc:sel-3532_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "A9982B6A-2CED-4EF4-946D-E4B8A8CE3935",
                    "versionEndExcluding": "r150-v2",
                    "versionStartIncluding": "r132-v0",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:selinc:sel-3532:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "E573857F-C6DC-4E59-8F5B-4C51ED4D69DB",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:selinc:sel-3555_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "9333068D-CE59-4644-879F-A1B29D07C26B",
                    "versionEndExcluding": "r150-v2",
                    "versionStartIncluding": "r134-v0",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:selinc:sel-3555:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "282F6DB1-4B0F-424F-B5E4-0827F1E7EE6F",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:selinc:sel-3560e_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "9BF86940-89E4-4D3C-B51D-CF189B8B20A3",
                    "versionEndExcluding": "r150-v2",
                    "versionStartIncluding": "r144-v2",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:selinc:sel-3560e:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "A3EB8694-DC56-4E35-9659-B2787F872E08",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:selinc:sel-3560s_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "28EAFD3D-1697-42BA-941E-2970A1177302",
                    "versionEndExcluding": "r150-v2",
                    "versionStartIncluding": "r144-v2",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:selinc:sel-3560s:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "F9D2A4A4-B81E-4034-863D-900D95166543",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "A Channel Accessible by Non-Endpoint vulnerability in the Schweitzer Engineering Laboratories SEL Real-Time Automation Controller (RTAC) could allow a remote attacker to perform a man-in-the-middle (MiTM) that could result in denial of service.\n\nSee the ACSELERATOR RTAC SEL-5033 Software instruction manual date code 20210915 for more details."
          }
        ],
        "id": "CVE-2023-2310",
        "lastModified": "2026-06-17T05:52:15.170",
        "metrics": {
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 6.8,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:N/I:H/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 1.6,
              "impactScore": 5.2,
              "source": "security@selinc.com",
              "type": "Secondary"
            },
            {
              "cvssData": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 1.6,
              "impactScore": 3.6,
              "source": "nvd@nist.gov",
              "type": "Primary"
            }
          ],
          "ssvcV203": [
            {
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "ssvcData": {
                "id": "CVE-2023-2310",
                "options": [
                  {
                    "exploitation": "none"
                  },
                  {
                    "automatable": "no"
                  },
                  {
                    "technicalImpact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-27T18:20:24.063475Z",
                "version": "2.0.3"
              }
            }
          ]
        },
        "published": "2023-05-10T20:15:09.637",
        "references": [
          {
            "source": "security@selinc.com",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "https://selinc.com/support/security-notifications/external-reports/"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "https://selinc.com/support/security-notifications/external-reports/"
          }
        ],
        "sourceIdentifier": "security@selinc.com",
        "vulnStatus": "Modified",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-300"
              }
            ],
            "source": "security@selinc.com",
            "type": "Secondary"
          },
          {
            "description": [
              {
                "lang": "en",
                "value": "NVD-CWE-Other"
              }
            ],
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      }
    },
    "redhat_vex": {
      "current_release_date": "2025-05-28T23:30:32+00:00",
      "cve": "CVE-2023-2310",
      "id": "CVE-2023-2310",
      "initial_release_date": "2023-05-10T07:00:00+00:00",
      "product_status:known_not_affected": "1",
      "source": "Red Hat CSAF VEX",
      "status": "final",
      "title": "Channel Accessible by Non-Endpoint",
      "url": "https://security.access.redhat.com/data/csaf/v2/vex/2023/cve-2023-2310.json",
      "version": "3"
    },
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T06:19:14.854Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://selinc.com/support/security-notifications/external-reports/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-2310",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-01-27T18:20:24.063475Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-01-27T18:20:30.416Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Linux"
              ],
              "product": "SEL-3505",
              "vendor": "Schweitzer Engineering Laboratories",
              "versions": [
                {
                  "lessThan": "R150-V2",
                  "status": "affected",
                  "version": "R119-V0",
                  "versionType": "custom"
                },
                {
                  "lessThan": "R149-V4",
                  "status": "affected",
                  "version": "R119-V0",
                  "versionType": "custom"
                },
                {
                  "lessThan": "R148-V7",
                  "status": "affected",
                  "version": "R119-V0",
                  "versionType": "custom"
                },
                {
                  "lessThan": "R147-V6",
                  "status": "affected",
                  "version": "R119-V0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Linux"
              ],
              "product": "SEL-3505-3",
              "vendor": "Schweitzer Engineering Laboratories, Inc.",
              "versions": [
                {
                  "lessThan": "R150-V2",
                  "status": "affected",
                  "version": "R132-V0",
                  "versionType": "custom"
                },
                {
                  "lessThan": "R149-V4",
                  "status": "affected",
                  "version": "R132-V0",
                  "versionType": "custom"
                },
                {
                  "lessThan": "R148-V7",
                  "status": "affected",
                  "version": "R132-V0",
                  "versionType": "custom"
                },
                {
                  "lessThan": "R147-V6",
                  "status": "affected",
                  "version": "R132-V0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Linux"
              ],
              "product": "SEL-3530",
              "vendor": "Schweitzer Engineering Laboratories",
              "versions": [
                {
                  "lessThan": "R150-V2",
                  "status": "affected",
                  "version": "R100-V0",
                  "versionType": "custom"
                },
                {
                  "lessThan": "R149-V4",
                  "status": "affected",
                  "version": "R100-V0",
                  "versionType": "custom"
                },
                {
                  "lessThan": "R148-V7",
                  "status": "affected",
                  "version": "R100-V0",
                  "versionType": "custom"
                },
                {
                  "lessThan": "R147-V6",
                  "status": "affected",
                  "version": "R100-V0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Linux"
              ],
              "product": "SEL-3530-4",
              "vendor": "Schweitzer Engineering Laboratories, Inc.",
              "versions": [
                {
                  "lessThan": "R150-V2",
                  "status": "affected",
                  "version": "R108-V0",
                  "versionType": "custom"
                },
                {
                  "lessThan": "R149-V4",
                  "status": "affected",
                  "version": "R108-V0",
                  "versionType": "custom"
                },
                {
                  "lessThan": "R148-V7",
                  "status": "affected",
                  "version": "R108-V0",
                  "versionType": "custom"
                },
                {
                  "lessThan": "R147-V6",
                  "status": "affected",
                  "version": "R108-V0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Linux"
              ],
              "product": "SEL-3532",
              "vendor": "Schweitzer Engineering Laboratories, Inc.",
              "versions": [
                {
                  "lessThan": "R150-V2",
                  "status": "affected",
                  "version": "R132-V0",
                  "versionType": "custom"
                },
                {
                  "lessThan": "R149-V4",
                  "status": "affected",
                  "version": "R132-V0",
                  "versionType": "custom"
                },
                {
                  "lessThan": "R148-V7",
                  "status": "affected",
                  "version": "R132-V0",
                  "versionType": "custom"
                },
                {
                  "lessThan": "R147-V6",
                  "status": "affected",
                  "version": "R132-V0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Linux"
              ],
              "product": "SEL-3555",
              "vendor": "Schweitzer Engineering Laboratories, Inc.",
              "versions": [
                {
                  "lessThan": "R150-V2",
                  "status": "affected",
                  "version": "R134-V0",
                  "versionType": "custom"
                },
                {
                  "lessThan": "R149-V4",
                  "status": "affected",
                  "version": "R134-V0",
                  "versionType": "custom"
                },
                {
                  "lessThan": "R148-V7",
                  "status": "affected",
                  "version": "R134-V0",
                  "versionType": "custom"
                },
                {
                  "lessThan": "R147-V6",
                  "status": "affected",
                  "version": "R134-V0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Linux"
              ],
              "product": "SEL-3560S",
              "vendor": "Schweitzer Engineering Laboratories, Inc.",
              "versions": [
                {
                  "lessThan": "R150-V2",
                  "status": "affected",
                  "version": "R144-V2",
                  "versionType": "custom"
                },
                {
                  "lessThan": "R149-V4",
                  "status": "affected",
                  "version": "R144-V2",
                  "versionType": "custom"
                },
                {
                  "lessThan": "R148-V7",
                  "status": "affected",
                  "version": "R144-V2",
                  "versionType": "custom"
                },
                {
                  "lessThan": "R147-V6",
                  "status": "affected",
                  "version": "R144-V2",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Linux"
              ],
              "product": "SEL-3560E",
              "vendor": "Schweitzer Engineering Laboratories, Inc.",
              "versions": [
                {
                  "lessThan": "R150-V2",
                  "status": "affected",
                  "version": "R144-V2",
                  "versionType": "custom"
                },
                {
                  "lessThan": "R149-V4",
                  "status": "affected",
                  "version": "R144-V2",
                  "versionType": "custom"
                },
                {
                  "lessThan": "R148-V7",
                  "status": "affected",
                  "version": "R144-V2",
                  "versionType": "custom"
                },
                {
                  "lessThan": "R147-V6",
                  "status": "affected",
                  "version": "R144-V2",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Linux"
              ],
              "product": "SEL-2241 RTAC module",
              "vendor": "Schweitzer Engineering Laboratories, Inc.",
              "versions": [
                {
                  "lessThan": "R150-V2",
                  "status": "affected",
                  "version": "R113-V0",
                  "versionType": "custom"
                },
                {
                  "lessThan": "R149-V4",
                  "status": "affected",
                  "version": "R113-V0",
                  "versionType": "custom"
                },
                {
                  "lessThan": "R148-V7",
                  "status": "affected",
                  "version": "R113-V0",
                  "versionType": "custom"
                },
                {
                  "lessThan": "R147-V6",
                  "status": "affected",
                  "version": "R113-V0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Linux"
              ],
              "product": "SEL-3350",
              "vendor": "Schweitzer Engineering Laboratories, Inc.",
              "versions": [
                {
                  "lessThan": "R150-V2",
                  "status": "affected",
                  "version": "R148-V0",
                  "versionType": "custom"
                },
                {
                  "lessThan": "R149-V4",
                  "status": "affected",
                  "version": "R148-V0",
                  "versionType": "custom"
                },
                {
                  "lessThan": "R148-V7",
                  "status": "affected",
                  "version": "R148-V0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Adeen Ayub, Syed Ali Qasim, Irfan Ahmed, Virginia Commonwealth University"
            }
          ],
          "datePublic": "2023-05-10T07:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A Channel Accessible by Non-Endpoint vulnerability in the Schweitzer Engineering Laboratories SEL Real-Time Automation Controller (RTAC) could allow a remote attacker to perform a man-in-the-middle (MiTM) that could result in denial of service.\u003cbr\u003e\u003cbr\u003eSee the ACSELERATOR RTAC SEL-5033 Software instruction manual date code 20210915 for more details."
                }
              ],
              "value": "A Channel Accessible by Non-Endpoint vulnerability in the Schweitzer Engineering Laboratories SEL Real-Time Automation Controller (RTAC) could allow a remote attacker to perform a man-in-the-middle (MiTM) that could result in denial of service.\n\nSee the ACSELERATOR RTAC SEL-5033 Software instruction manual date code 20210915 for more details."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-469",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-469 DoS"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 6.8,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:N/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-300",
                  "description": "CWE-300 Channel Accessible by Non-Endpoint",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-05-10T19:18:43.806Z",
            "orgId": "5804bb70-792c-43e0-8596-486cc0efe699",
            "shortName": "SEL"
          },
          "references": [
            {
              "url": "https://selinc.com/support/security-notifications/external-reports/"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Channel Accessible by Non-Endpoint",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "5804bb70-792c-43e0-8596-486cc0efe699",
        "assignerShortName": "SEL",
        "cveId": "CVE-2023-2310",
        "datePublished": "2023-05-10T19:18:43.806Z",
        "dateReserved": "2023-04-26T18:25:33.932Z",
        "dateUpdated": "2025-01-27T18:20:35.192Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…