CVE-2022-44793 (GCVE-0-2022-44793)
Vulnerability from cvelistv5 – Published: 2022-11-07 00:00 – Updated: 2025-05-05 16:12- n/a
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T14:01:31.174Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://github.com/net-snmp/net-snmp/issues/475"
},
{
"tags": [
"x_transferred"
],
"url": "https://gist.github.com/menglong2234/d07a65b5028145c9f4e1d1db8c4c202f"
},
{
"name": "[debian-lts-announce] 20230115 [SECURITY] [DLA 3270-1] net-snmp security update",
"tags": [
"mailing-list",
"x_transferred"
],
"url": "https://lists.debian.org/debian-lts-announce/2023/01/msg00010.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://security.netapp.com/advisory/ntap-20230223-0011/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2022-44793",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-23T13:30:38.475099Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-476",
"description": "CWE-476 NULL Pointer Dereference",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-05-05T16:12:07.945Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "handle_ipv6IpForwarding in agent/mibgroup/ip-mib/ip_scalars.c in Net-SNMP 5.4.3 through 5.9.3 has a NULL Pointer Exception bug that can be used by a remote attacker to cause the instance to crash via a crafted UDP packet, resulting in Denial of Service."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-02-23T00:00:00.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://github.com/net-snmp/net-snmp/issues/475"
},
{
"url": "https://gist.github.com/menglong2234/d07a65b5028145c9f4e1d1db8c4c202f"
},
{
"name": "[debian-lts-announce] 20230115 [SECURITY] [DLA 3270-1] net-snmp security update",
"tags": [
"mailing-list"
],
"url": "https://lists.debian.org/debian-lts-announce/2023/01/msg00010.html"
},
{
"url": "https://security.netapp.com/advisory/ntap-20230223-0011/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2022-44793",
"datePublished": "2022-11-07T00:00:00.000Z",
"dateReserved": "2022-11-07T00:00:00.000Z",
"dateUpdated": "2025-05-05T16:12:07.945Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2022-44793",
"date": "2026-05-27",
"epss": "0.01438",
"percentile": "0.80962"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2022-44793\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2022-11-07T03:15:09.363\",\"lastModified\":\"2025-05-05T16:15:22.427\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"handle_ipv6IpForwarding in agent/mibgroup/ip-mib/ip_scalars.c in Net-SNMP 5.4.3 through 5.9.3 has a NULL Pointer Exception bug that can be used by a remote attacker to cause the instance to crash via a crafted UDP packet, resulting in Denial of Service.\"},{\"lang\":\"es\",\"value\":\"handle_ipv6IpForwarding en agent/mibgroup/ip-mib/ip_scalars.c en Net-SNMP 5.4.3 a 5.9.3 tiene un error de excepci\u00f3n de puntero NULL que puede ser utilizado por un atacante remoto para provocar que la instancia se bloquee a trav\u00e9s de un paquete UDP manipulado. resultando en Denegaci\u00f3n de Servicio.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H\",\"baseScore\":6.5,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":3.6},{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H\",\"baseScore\":6.5,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-476\"}]},{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-476\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:net-snmp:net-snmp:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"5.4.3\",\"versionEndIncluding\":\"5.9.3\",\"matchCriteriaId\":\"97E267EC-2F41-4233-8647-3BE21B487713\"}]}]},{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:debian:debian_linux:10.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"07B237A9-69A3-4A9C-9DA0-4E06BD37AE73\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netapp:h300s_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6770B6C3-732E-4E22-BF1C-2D2FD610061C\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netapp:h300s:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"9F9C8C20-42EB-4AB5-BD97-212DEB070C43\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netapp:h500s_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7FFF7106-ED78-49BA-9EC5-B889E3685D53\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netapp:h500s:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E63D8B0F-006E-4801-BF9D-1C001BBFB4F9\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netapp:h700s_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"56409CEC-5A1E-4450-AA42-641E459CC2AF\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netapp:h700s:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B06F4839-D16A-4A61-9BB5-55B13F41E47F\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netapp:h410s_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D0B4AD8A-F172-4558-AEC6-FF424BA2D912\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netapp:h410s:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8497A4C9-8474-4A62-8331-3FE862ED4098\"}]}]}],\"references\":[{\"url\":\"https://gist.github.com/menglong2234/d07a65b5028145c9f4e1d1db8c4c202f\",\"source\":\"cve@mitre.org\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"https://github.com/net-snmp/net-snmp/issues/475\",\"source\":\"cve@mitre.org\",\"tags\":[\"Exploit\",\"Issue Tracking\",\"Third Party Advisory\"]},{\"url\":\"https://lists.debian.org/debian-lts-announce/2023/01/msg00010.html\",\"source\":\"cve@mitre.org\",\"tags\":[\"Mailing List\",\"Third Party Advisory\"]},{\"url\":\"https://security.netapp.com/advisory/ntap-20230223-0011/\",\"source\":\"cve@mitre.org\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://gist.github.com/menglong2234/d07a65b5028145c9f4e1d1db8c4c202f\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"https://github.com/net-snmp/net-snmp/issues/475\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Exploit\",\"Issue Tracking\",\"Third Party Advisory\"]},{\"url\":\"https://lists.debian.org/debian-lts-announce/2023/01/msg00010.html\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Mailing List\",\"Third Party Advisory\"]},{\"url\":\"https://security.netapp.com/advisory/ntap-20230223-0011/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://github.com/net-snmp/net-snmp/issues/475\", \"tags\": [\"x_transferred\"]}, {\"url\": \"https://gist.github.com/menglong2234/d07a65b5028145c9f4e1d1db8c4c202f\", \"tags\": [\"x_transferred\"]}, {\"url\": \"https://lists.debian.org/debian-lts-announce/2023/01/msg00010.html\", \"name\": \"[debian-lts-announce] 20230115 [SECURITY] [DLA 3270-1] net-snmp security update\", \"tags\": [\"mailing-list\", \"x_transferred\"]}, {\"url\": \"https://security.netapp.com/advisory/ntap-20230223-0011/\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-03T14:01:31.174Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 6.5, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H\", \"integrityImpact\": \"NONE\", \"userInteraction\": \"REQUIRED\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"NONE\"}}, {\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2022-44793\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"poc\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-04-23T13:30:38.475099Z\"}}}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-476\", \"description\": \"CWE-476 NULL Pointer Dereference\"}]}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-05-05T13:07:50.714Z\"}}], \"cna\": {\"affected\": [{\"vendor\": \"n/a\", \"product\": \"n/a\", \"versions\": [{\"status\": \"affected\", \"version\": \"n/a\"}]}], \"references\": [{\"url\": \"https://github.com/net-snmp/net-snmp/issues/475\"}, {\"url\": \"https://gist.github.com/menglong2234/d07a65b5028145c9f4e1d1db8c4c202f\"}, {\"url\": \"https://lists.debian.org/debian-lts-announce/2023/01/msg00010.html\", \"name\": \"[debian-lts-announce] 20230115 [SECURITY] [DLA 3270-1] net-snmp security update\", \"tags\": [\"mailing-list\"]}, {\"url\": \"https://security.netapp.com/advisory/ntap-20230223-0011/\"}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"handle_ipv6IpForwarding in agent/mibgroup/ip-mib/ip_scalars.c in Net-SNMP 5.4.3 through 5.9.3 has a NULL Pointer Exception bug that can be used by a remote attacker to cause the instance to crash via a crafted UDP packet, resulting in Denial of Service.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"text\", \"description\": \"n/a\"}]}], \"providerMetadata\": {\"orgId\": \"8254265b-2729-46b6-b9e3-3dfca2d5bfca\", \"shortName\": \"mitre\", \"dateUpdated\": \"2023-02-23T00:00:00.000Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2022-44793\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-05-05T16:12:07.945Z\", \"dateReserved\": \"2022-11-07T00:00:00.000Z\", \"assignerOrgId\": \"8254265b-2729-46b6-b9e3-3dfca2d5bfca\", \"datePublished\": \"2022-11-07T00:00:00.000Z\", \"assignerShortName\": \"mitre\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
alsa-2023:2444
Vulnerability from osv_almalinux
The net-snmp packages provide various libraries and tools for the Simple Network Management Protocol (SNMP), including an SNMP library, an extensible agent, tools for requesting or setting information from SNMP agents, tools for generating and handling SNMP traps, a version of the netstat command which uses SNMP, and a Tk/Perl Management Information Base (MIB) browser.
Security Fix(es):
- net-snmp: NULL Pointer Exception when handling ipDefaultTTL (CVE-2022-44792)
- net-snmp: NULL Pointer Exception when handling pv6IpForwarding (CVE-2022-44793)
For more details about the security issue(s), including the impact, a CVSS score, acknowledgments, and other related information, refer to the CVE page(s) listed in the References section.
Additional Changes:
For detailed information on changes in this release, see the AlmaLinux Release Notes linked from the References section.
{
"affected": [
{
"package": {
"ecosystem": "AlmaLinux:9",
"name": "net-snmp"
},
"ranges": [
{
"events": [
{
"introduced": "0"
},
{
"fixed": "1:5.9.1-9.el9"
}
],
"type": "ECOSYSTEM"
}
]
},
{
"package": {
"ecosystem": "AlmaLinux:9",
"name": "net-snmp-agent-libs"
},
"ranges": [
{
"events": [
{
"introduced": "0"
},
{
"fixed": "1:5.9.1-9.el9"
}
],
"type": "ECOSYSTEM"
}
]
},
{
"package": {
"ecosystem": "AlmaLinux:9",
"name": "net-snmp-devel"
},
"ranges": [
{
"events": [
{
"introduced": "0"
},
{
"fixed": "1:5.9.1-9.el9"
}
],
"type": "ECOSYSTEM"
}
]
},
{
"package": {
"ecosystem": "AlmaLinux:9",
"name": "net-snmp-libs"
},
"ranges": [
{
"events": [
{
"introduced": "0"
},
{
"fixed": "1:5.9.1-9.el9"
}
],
"type": "ECOSYSTEM"
}
]
},
{
"package": {
"ecosystem": "AlmaLinux:9",
"name": "net-snmp-perl"
},
"ranges": [
{
"events": [
{
"introduced": "0"
},
{
"fixed": "1:5.9.1-9.el9"
}
],
"type": "ECOSYSTEM"
}
]
},
{
"package": {
"ecosystem": "AlmaLinux:9",
"name": "net-snmp-utils"
},
"ranges": [
{
"events": [
{
"introduced": "0"
},
{
"fixed": "1:5.9.1-9.el9"
}
],
"type": "ECOSYSTEM"
}
]
},
{
"package": {
"ecosystem": "AlmaLinux:9",
"name": "python3-net-snmp"
},
"ranges": [
{
"events": [
{
"introduced": "0"
},
{
"fixed": "1:5.9.1-9.el9"
}
],
"type": "ECOSYSTEM"
}
]
}
],
"details": "The net-snmp packages provide various libraries and tools for the Simple Network Management Protocol (SNMP), including an SNMP library, an extensible agent, tools for requesting or setting information from SNMP agents, tools for generating and handling SNMP traps, a version of the netstat command which uses SNMP, and a Tk/Perl Management Information Base (MIB) browser.\n\nSecurity Fix(es):\n\n* net-snmp: NULL Pointer Exception when handling ipDefaultTTL (CVE-2022-44792)\n* net-snmp: NULL Pointer Exception when handling pv6IpForwarding (CVE-2022-44793)\n\nFor more details about the security issue(s), including the impact, a CVSS score, acknowledgments, and other related information, refer to the CVE page(s) listed in the References section.\n\nAdditional Changes:\n\nFor detailed information on changes in this release, see the AlmaLinux Release Notes linked from the References section.",
"id": "ALSA-2023:2444",
"modified": "2023-05-12T04:11:46Z",
"published": "2023-05-09T00:00:00Z",
"references": [
{
"type": "ADVISORY",
"url": "https://access.redhat.com/errata/RHSA-2023:2444"
},
{
"type": "REPORT",
"url": "https://access.redhat.com/security/cve/CVE-2022-44792"
},
{
"type": "REPORT",
"url": "https://access.redhat.com/security/cve/CVE-2022-44793"
},
{
"type": "REPORT",
"url": "https://bugzilla.redhat.com/2141897"
},
{
"type": "REPORT",
"url": "https://bugzilla.redhat.com/2141898"
},
{
"type": "ADVISORY",
"url": "https://errata.almalinux.org/9/ALSA-2023-2444.html"
}
],
"related": [
"CVE-2022-44792",
"CVE-2022-44793"
],
"summary": "Moderate: net-snmp security and bug fix update"
}
alsa-2023:2969
Vulnerability from osv_almalinux
The net-snmp packages provide various libraries and tools for the Simple Network Management Protocol (SNMP), including an SNMP library, an extensible agent, tools for requesting or setting information from SNMP agents, tools for generating and handling SNMP traps, a version of the netstat command which uses SNMP, and a Tk/Perl Management Information Base (MIB) browser.
Security Fix(es):
- net-snmp: NULL Pointer Exception when handling ipDefaultTTL (CVE-2022-44792)
- net-snmp: NULL Pointer Exception when handling pv6IpForwarding (CVE-2022-44793)
For more details about the security issue(s), including the impact, a CVSS score, acknowledgments, and other related information, refer to the CVE page(s) listed in the References section.
Additional Changes:
For detailed information on changes in this release, see the AlmaLinux Release Notes linked from the References section.
| URL | Type | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||
{
"affected": [
{
"package": {
"ecosystem": "AlmaLinux:8",
"name": "net-snmp"
},
"ranges": [
{
"events": [
{
"introduced": "0"
},
{
"fixed": "1:5.8-27.el8"
}
],
"type": "ECOSYSTEM"
}
]
},
{
"package": {
"ecosystem": "AlmaLinux:8",
"name": "net-snmp-agent-libs"
},
"ranges": [
{
"events": [
{
"introduced": "0"
},
{
"fixed": "1:5.8-27.el8"
}
],
"type": "ECOSYSTEM"
}
]
},
{
"package": {
"ecosystem": "AlmaLinux:8",
"name": "net-snmp-devel"
},
"ranges": [
{
"events": [
{
"introduced": "0"
},
{
"fixed": "1:5.8-27.el8"
}
],
"type": "ECOSYSTEM"
}
]
},
{
"package": {
"ecosystem": "AlmaLinux:8",
"name": "net-snmp-libs"
},
"ranges": [
{
"events": [
{
"introduced": "0"
},
{
"fixed": "1:5.8-27.el8"
}
],
"type": "ECOSYSTEM"
}
]
},
{
"package": {
"ecosystem": "AlmaLinux:8",
"name": "net-snmp-perl"
},
"ranges": [
{
"events": [
{
"introduced": "0"
},
{
"fixed": "1:5.8-27.el8"
}
],
"type": "ECOSYSTEM"
}
]
},
{
"package": {
"ecosystem": "AlmaLinux:8",
"name": "net-snmp-utils"
},
"ranges": [
{
"events": [
{
"introduced": "0"
},
{
"fixed": "1:5.8-27.el8"
}
],
"type": "ECOSYSTEM"
}
]
}
],
"details": "The net-snmp packages provide various libraries and tools for the Simple Network Management Protocol (SNMP), including an SNMP library, an extensible agent, tools for requesting or setting information from SNMP agents, tools for generating and handling SNMP traps, a version of the netstat command which uses SNMP, and a Tk/Perl Management Information Base (MIB) browser.\n\nSecurity Fix(es):\n\n* net-snmp: NULL Pointer Exception when handling ipDefaultTTL (CVE-2022-44792)\n* net-snmp: NULL Pointer Exception when handling pv6IpForwarding (CVE-2022-44793)\n\nFor more details about the security issue(s), including the impact, a CVSS score, acknowledgments, and other related information, refer to the CVE page(s) listed in the References section.\n\nAdditional Changes:\n\nFor detailed information on changes in this release, see the AlmaLinux Release Notes linked from the References section.",
"id": "ALSA-2023:2969",
"modified": "2023-05-19T22:02:48Z",
"published": "2023-05-16T00:00:00Z",
"references": [
{
"type": "ADVISORY",
"url": "https://access.redhat.com/errata/RHSA-2023:2969"
},
{
"type": "REPORT",
"url": "https://access.redhat.com/security/cve/CVE-2022-44792"
},
{
"type": "REPORT",
"url": "https://access.redhat.com/security/cve/CVE-2022-44793"
},
{
"type": "REPORT",
"url": "https://bugzilla.redhat.com/2141897"
},
{
"type": "REPORT",
"url": "https://bugzilla.redhat.com/2141898"
},
{
"type": "ADVISORY",
"url": "https://errata.almalinux.org/8/ALSA-2023-2969.html"
}
],
"related": [
"CVE-2022-44792",
"CVE-2022-44793"
],
"summary": "Moderate: net-snmp security and bug fix update"
}
BDU:2024-06511
Vulnerability from fstec - Published: 06.11.2022{
"CVSS 2.0": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"CVSS 3.0": "AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H",
"CVSS 4.0": null,
"remediation_\u0418\u0434\u0435\u043d\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u043e\u0440": null,
"remediation_\u041d\u0430\u0438\u043c\u0435\u043d\u043e\u0432\u0430\u043d\u0438\u0435": null,
"\u0412\u0435\u043d\u0434\u043e\u0440 \u041f\u041e": "Red Hat Inc., \u0421\u043e\u043e\u0431\u0449\u0435\u0441\u0442\u0432\u043e \u0441\u0432\u043e\u0431\u043e\u0434\u043d\u043e\u0433\u043e \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e\u0433\u043e \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f, \u041e\u041e\u041e \u00ab\u0420\u0435\u0434 \u0421\u043e\u0444\u0442\u00bb, \u0410\u041e \"\u041d\u041f\u041f\u041a\u0422\", \u0410\u041e \u00ab\u041d\u0422\u0426 \u0418\u0422 \u0420\u041e\u0421\u0410\u00bb",
"\u0412\u0435\u0440\u0441\u0438\u044f \u041f\u041e": "8 (Red Hat Enterprise Linux), 10 (Debian GNU/Linux), 11 (Debian GNU/Linux), 12 (Debian GNU/Linux), 7.3 (\u0420\u0415\u0414 \u041e\u0421), 9 (Red Hat Enterprise Linux), \u0434\u043e 2.7 (\u041e\u0421\u041e\u041d \u041e\u0421\u043d\u043e\u0432\u0430 \u041enyx), 12.4 (\u0420\u041e\u0421\u0410 \u0425\u0420\u041e\u041c), \u043e\u0442 5.8 \u0434\u043e 5.9.3 \u0432\u043a\u043b\u044e\u0447\u0438\u0442\u0435\u043b\u044c\u043d\u043e (Net-SNMP)",
"\u0412\u043e\u0437\u043c\u043e\u0436\u043d\u044b\u0435 \u043c\u0435\u0440\u044b \u043f\u043e \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u044e": "\u0414\u043b\u044f Net-SNMP:\nhttps://github.com/net-snmp/net-snmp/issues/475\nhttps://gist.github.com/menglong2234/d07a65b5028145c9f4e1d1db8c4c202f\nhttps://github.com/net-snmp/net-snmp/commit/be804106fd0771a7d05236cff36e199af077af57\n\n\u0414\u043b\u044f \u0420\u0435\u0434\u041e\u0421: http://repo.red-soft.ru/redos/7.3c/x86_64/updates/\n\n\u0414\u043b\u044f Debian GNU/Linux:\nhttps://security-tracker.debian.org/tracker/CVE-2022-44793\n\n\u0414\u043b\u044f \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u044b\u0445 \u043f\u0440\u043e\u0434\u0443\u043a\u0442\u043e\u0432 Red Hat Inc.:\nhttps://access.redhat.com/security/cve/CVE-2022-44793\n\n\u0414\u043b\u044f \u041e\u0421\u041e\u041d \u041e\u0421\u043d\u043e\u0432\u0430 \u041enyx: \u041e\u0431\u043d\u043e\u0432\u043b\u0435\u043d\u0438\u0435 \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e\u0433\u043e \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f net-snmp \u0434\u043e \u0432\u0435\u0440\u0441\u0438\u0438 5.7.3+dfsg-5+deb10u4\n\n\u0414\u043b\u044f \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u043e\u043d\u043d\u043e\u0439 \u0441\u0438\u0441\u0442\u0435\u043c\u044b \u0420\u041e\u0421\u0410 \u0425\u0420\u041e\u041c: https://abf.rosa.ru/advisories/ROSA-SA-2024-2473",
"\u0414\u0430\u0442\u0430 \u0432\u044b\u044f\u0432\u043b\u0435\u043d\u0438\u044f": "06.11.2022",
"\u0414\u0430\u0442\u0430 \u043f\u043e\u0441\u043b\u0435\u0434\u043d\u0435\u0433\u043e \u043e\u0431\u043d\u043e\u0432\u043b\u0435\u043d\u0438\u044f": "05.03.2025",
"\u0414\u0430\u0442\u0430 \u043f\u0443\u0431\u043b\u0438\u043a\u0430\u0446\u0438\u0438": "27.08.2024",
"\u0418\u0434\u0435\u043d\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u043e\u0440": "BDU:2024-06511",
"\u0418\u0434\u0435\u043d\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u043e\u0440\u044b \u0434\u0440\u0443\u0433\u0438\u0445 \u0441\u0438\u0441\u0442\u0435\u043c \u043e\u043f\u0438\u0441\u0430\u043d\u0438\u0439 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "CVE-2022-44793",
"\u0418\u043d\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u044f \u043e\u0431 \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0430",
"\u041a\u043b\u0430\u0441\u0441 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u043a\u043e\u0434\u0430",
"\u041d\u0430\u0437\u0432\u0430\u043d\u0438\u0435 \u041f\u041e": "Red Hat Enterprise Linux, Debian GNU/Linux, \u0420\u0415\u0414 \u041e\u0421 (\u0437\u0430\u043f\u0438\u0441\u044c \u0432 \u0435\u0434\u0438\u043d\u043e\u043c \u0440\u0435\u0435\u0441\u0442\u0440\u0435 \u0440\u043e\u0441\u0441\u0438\u0439\u0441\u043a\u0438\u0445 \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c \u21163751), \u041e\u0421\u041e\u041d \u041e\u0421\u043d\u043e\u0432\u0430 \u041enyx (\u0437\u0430\u043f\u0438\u0441\u044c \u0432 \u0435\u0434\u0438\u043d\u043e\u043c \u0440\u0435\u0435\u0441\u0442\u0440\u0435 \u0440\u043e\u0441\u0441\u0438\u0439\u0441\u043a\u0438\u0445 \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c \u21165913), \u0420\u041e\u0421\u0410 \u0425\u0420\u041e\u041c (\u0437\u0430\u043f\u0438\u0441\u044c \u0432 \u0435\u0434\u0438\u043d\u043e\u043c \u0440\u0435\u0435\u0441\u0442\u0440\u0435 \u0440\u043e\u0441\u0441\u0438\u0439\u0441\u043a\u0438\u0445 \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c \u21161607), Net-SNMP",
"\u041d\u0430\u0438\u043c\u0435\u043d\u043e\u0432\u0430\u043d\u0438\u0435 \u041e\u0421 \u0438 \u0442\u0438\u043f \u0430\u043f\u043f\u0430\u0440\u0430\u0442\u043d\u043e\u0439 \u043f\u043b\u0430\u0442\u0444\u043e\u0440\u043c\u044b": "Red Hat Inc. Red Hat Enterprise Linux 8 , \u0421\u043e\u043e\u0431\u0449\u0435\u0441\u0442\u0432\u043e \u0441\u0432\u043e\u0431\u043e\u0434\u043d\u043e\u0433\u043e \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e\u0433\u043e \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f Debian GNU/Linux 10 , \u0421\u043e\u043e\u0431\u0449\u0435\u0441\u0442\u0432\u043e \u0441\u0432\u043e\u0431\u043e\u0434\u043d\u043e\u0433\u043e \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e\u0433\u043e \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f Debian GNU/Linux 11 , \u0421\u043e\u043e\u0431\u0449\u0435\u0441\u0442\u0432\u043e \u0441\u0432\u043e\u0431\u043e\u0434\u043d\u043e\u0433\u043e \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e\u0433\u043e \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f Debian GNU/Linux 12 , \u041e\u041e\u041e \u00ab\u0420\u0435\u0434 \u0421\u043e\u0444\u0442\u00bb \u0420\u0415\u0414 \u041e\u0421 7.3 (\u0437\u0430\u043f\u0438\u0441\u044c \u0432 \u0435\u0434\u0438\u043d\u043e\u043c \u0440\u0435\u0435\u0441\u0442\u0440\u0435 \u0440\u043e\u0441\u0441\u0438\u0439\u0441\u043a\u0438\u0445 \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c \u21163751), Red Hat Inc. Red Hat Enterprise Linux 9 , \u0410\u041e \"\u041d\u041f\u041f\u041a\u0422\" \u041e\u0421\u041e\u041d \u041e\u0421\u043d\u043e\u0432\u0430 \u041enyx \u0434\u043e 2.7 (\u0437\u0430\u043f\u0438\u0441\u044c \u0432 \u0435\u0434\u0438\u043d\u043e\u043c \u0440\u0435\u0435\u0441\u0442\u0440\u0435 \u0440\u043e\u0441\u0441\u0438\u0439\u0441\u043a\u0438\u0445 \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c \u21165913), \u0410\u041e \u00ab\u041d\u0422\u0426 \u0418\u0422 \u0420\u041e\u0421\u0410\u00bb \u0420\u041e\u0421\u0410 \u0425\u0420\u041e\u041c 12.4 (\u0437\u0430\u043f\u0438\u0441\u044c \u0432 \u0435\u0434\u0438\u043d\u043e\u043c \u0440\u0435\u0435\u0441\u0442\u0440\u0435 \u0440\u043e\u0441\u0441\u0438\u0439\u0441\u043a\u0438\u0445 \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c \u21161607)",
"\u041d\u0430\u0438\u043c\u0435\u043d\u043e\u0432\u0430\u043d\u0438\u0435 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u0444\u0443\u043d\u043a\u0446\u0438\u0438 handle_ipv6IpForwarding() \u043d\u0430\u0431\u043e\u0440\u0430 \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e\u0433\u043e \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f Net-SNMP \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u043e\u043d\u043d\u043e\u0439 \u0441\u0438\u0441\u0442\u0435\u043c\u044b Linux, \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u044e\u0449\u0430\u044f \u043d\u0430\u0440\u0443\u0448\u0438\u0442\u0435\u043b\u044e \u0432\u044b\u0437\u0432\u0430\u0442\u044c \u043e\u0442\u043a\u0430\u0437 \u0432 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0438",
"\u041d\u0430\u043b\u0438\u0447\u0438\u0435 \u044d\u043a\u0441\u043f\u043b\u043e\u0439\u0442\u0430": "\u0421\u0443\u0449\u0435\u0441\u0442\u0432\u0443\u0435\u0442 \u0432 \u043e\u0442\u043a\u0440\u044b\u0442\u043e\u043c \u0434\u043e\u0441\u0442\u0443\u043f\u0435",
"\u041e\u043f\u0438\u0441\u0430\u043d\u0438\u0435 \u043e\u0448\u0438\u0431\u043a\u0438 CWE": "\u0420\u0430\u0437\u044b\u043c\u0435\u043d\u043e\u0432\u0430\u043d\u0438\u0435 \u0443\u043a\u0430\u0437\u0430\u0442\u0435\u043b\u044f NULL (CWE-476)",
"\u041e\u043f\u0438\u0441\u0430\u043d\u0438\u0435 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u0444\u0443\u043d\u043a\u0446\u0438\u0438 handle_ipv6IpForwarding() \u043d\u0430\u0431\u043e\u0440\u0430 \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e\u0433\u043e \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f Net-SNMP \u043e\u043f\u0435\u0440\u0430\u0446\u0438\u043e\u043d\u043d\u043e\u0439 \u0441\u0438\u0441\u0442\u0435\u043c\u044b Linux \u0441\u0432\u044f\u0437\u0430\u043d\u0430 \u0441 \u043e\u0448\u0438\u0431\u043a\u043e\u0439 NULL Pointer Exception, \u043a\u043e\u0442\u043e\u0440\u0443\u044e \u043c\u043e\u0436\u0435\u0442 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u0442\u044c \u0434\u043b\u044f \u0441\u0431\u043e\u044f \u044d\u043a\u0437\u0435\u043c\u043f\u043b\u044f\u0440\u0430 \u0441 \u043f\u043e\u043c\u043e\u0449\u044c\u044e \u0441\u043f\u0435\u0446\u0438\u0430\u043b\u044c\u043d\u043e \u0441\u043e\u0437\u0434\u0430\u043d\u043d\u043e\u0433\u043e UDP-\u043f\u0430\u043a\u0435\u0442\u0430. \u042d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u044f \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438 \u043c\u043e\u0436\u0435\u0442 \u043f\u043e\u0437\u0432\u043e\u043b\u0438\u0442\u044c \u043d\u0430\u0440\u0443\u0448\u0438\u0442\u0435\u043b\u044e, \u0434\u0435\u0439\u0441\u0442\u0432\u0443\u044e\u0449\u0435\u043c\u0443 \u0443\u0434\u0430\u043b\u0435\u043d\u043d\u043e, \u0432\u044b\u0437\u0432\u0430\u0442\u044c \u043e\u0442\u043a\u0430\u0437 \u0432 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0438",
"\u041f\u043e\u0441\u043b\u0435\u0434\u0441\u0442\u0432\u0438\u044f \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": null,
"\u041f\u0440\u043e\u0447\u0430\u044f \u0438\u043d\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u044f": null,
"\u0421\u0432\u044f\u0437\u044c \u0441 \u0438\u043d\u0446\u0438\u0434\u0435\u043d\u0442\u0430\u043c\u0438 \u0418\u0411": "\u0414\u0430\u043d\u043d\u044b\u0435 \u0443\u0442\u043e\u0447\u043d\u044f\u044e\u0442\u0441\u044f",
"\u0421\u043e\u0441\u0442\u043e\u044f\u043d\u0438\u0435 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u041e\u043f\u0443\u0431\u043b\u0438\u043a\u043e\u0432\u0430\u043d\u0430",
"\u0421\u043f\u043e\u0441\u043e\u0431 \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u044f": "\u041e\u0431\u043d\u043e\u0432\u043b\u0435\u043d\u0438\u0435 \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e\u0433\u043e \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f",
"\u0421\u043f\u043e\u0441\u043e\u0431 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438": "\u041c\u0430\u043d\u0438\u043f\u0443\u043b\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0435 \u0441\u0442\u0440\u0443\u043a\u0442\u0443\u0440\u0430\u043c\u0438 \u0434\u0430\u043d\u043d\u044b\u0445",
"\u0421\u0441\u044b\u043b\u043a\u0438 \u043d\u0430 \u0438\u0441\u0442\u043e\u0447\u043d\u0438\u043a\u0438": "https://gist.github.com/menglong2234/d07a65b5028145c9f4e1d1db8c4c202f\nhttps://github.com/net-snmp/net-snmp/commit/be804106fd0771a7d05236cff36e199af077af57\nhttps://github.com/net-snmp/net-snmp/issues/475\nhttps://redos.red-soft.ru/support/secure/\nhttps://security-tracker.debian.org/tracker/CVE-2022-44793\nhttps://access.redhat.com/security/cve/CVE-2022-44793\nhttps://\u043f\u043e\u0434\u0434\u0435\u0440\u0436\u043a\u0430.\u043d\u043f\u043f\u043a\u0442.\u0440\u0444/bin/view/\u041e\u0421\u043d\u043e\u0432\u0430/\u041e\u0431\u043d\u043e\u0432\u043b\u0435\u043d\u0438\u044f/2.7/\nhttps://abf.rosa.ru/advisories/ROSA-SA-2024-2473",
"\u0421\u0442\u0430\u0442\u0443\u0441 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u041f\u043e\u0434\u0442\u0432\u0435\u0440\u0436\u0434\u0435\u043d\u0430 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0435\u043c",
"\u0422\u0438\u043f \u041f\u041e": "\u041e\u043f\u0435\u0440\u0430\u0446\u0438\u043e\u043d\u043d\u0430\u044f \u0441\u0438\u0441\u0442\u0435\u043c\u0430, \u0421\u0435\u0442\u0435\u0432\u043e\u0435 \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e\u0435 \u0441\u0440\u0435\u0434\u0441\u0442\u0432\u043e",
"\u0422\u0438\u043f \u043e\u0448\u0438\u0431\u043a\u0438 CWE": "CWE-476",
"\u0423\u0440\u043e\u0432\u0435\u043d\u044c \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0412\u044b\u0441\u043e\u043a\u0438\u0439 \u0443\u0440\u043e\u0432\u0435\u043d\u044c \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 (\u0431\u0430\u0437\u043e\u0432\u0430\u044f \u043e\u0446\u0435\u043d\u043a\u0430 CVSS 2.0 \u0441\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u0435\u0442 7,8)\n\u0421\u0440\u0435\u0434\u043d\u0438\u0439 \u0443\u0440\u043e\u0432\u0435\u043d\u044c \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 (\u0431\u0430\u0437\u043e\u0432\u0430\u044f \u043e\u0446\u0435\u043d\u043a\u0430 CVSS 3.0 \u0441\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u0435\u0442 6,5)"
}
CERTFR-2023-AVI-0318
Vulnerability from certfr_avis - Published: 2023-04-17 - Updated: 2023-04-17
De multiples vulnérabilités ont été découvertes dans VMware. Elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, une élévation de privilèges, un déni de service à distance et une atteinte à la confidentialité des données.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| VMware | N/A | Isolation Segment versions 2.12.x antérieures à 2.12.19 | ||
| VMware | Tanzu | VMware Tanzu Application Service for VMs versions 2.12.x antérieures à 2.12.24 | ||
| VMware | N/A | Canonical Ubuntu 18.04 | ||
| VMware | Tanzu | VMware Tanzu Application Service for VMs versions 2.13.x antérieures à 2.13.17 | ||
| VMware | N/A | Platform Automation Toolkit versions 4.0.x antérieures à to 4.0.13 | ||
| VMware | Tanzu | VMware Tanzu Application Service for VMs versions 2.11.x antérieures à 2.11.35 | ||
| VMware | N/A | Platform Automation Toolkit versions 4.3.x versions antérieures à 4.3.5 | ||
| VMware | N/A | Platform Automation Toolkit versions 5.1.x versions antérieures à 5.1.0 | ||
| VMware | N/A | Operations Manager versions 3.0.x antérieures à 3.0.4 | ||
| VMware | N/A | Operations Manager versions 2.10.x antérieures à 2.10.51 | ||
| VMware | N/A | Isolation Segment versions 3.0.x antérieures à 3.0.7 (avec Jammy Stemcells versions antérieures à 1.80) | ||
| VMware | N/A | Isolation Segment versions 2.11.x antérieures à 2.11.29 | ||
| VMware | N/A | Platform Automation Toolkit versions 4.2.x antérieures à 4.2.8 | ||
| VMware | N/A | Canonical Ubuntu 16.04 | ||
| VMware | N/A | Platform Automation Toolkit versions 4.4.x versions antérieures à 4.4.30 | ||
| VMware | N/A | Canonical Ubuntu 22.04 | ||
| VMware | Tanzu | VMware Tanzu Application Service for VMs versions 3.0.x antérieures à 3.0.7 (avec Jammy Stemcells versions 1.80) | ||
| VMware | N/A | Platform Automation Toolkit versions 5.0.x versions antérieures à 5.0.23 | ||
| VMware | N/A | Isolation Segment versions 2.13.x antérieures à 2.13.14 | ||
| VMware | Tanzu | Tanzu Greenplum for Kubernetes versions antérieures à 1.4.0 | ||
| VMware | N/A | Platform Automation Toolkit versions 4.1.x antérieures à 4.1.13 |
| Title | Publication Time | Tags | ||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||||||||||||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "Isolation Segment versions 2.12.x ant\u00e9rieures \u00e0 2.12.19",
"product": {
"name": "N/A",
"vendor": {
"name": "VMware",
"scada": false
}
}
},
{
"description": "VMware Tanzu Application Service for VMs versions 2.12.x ant\u00e9rieures \u00e0 2.12.24",
"product": {
"name": "Tanzu",
"vendor": {
"name": "VMware",
"scada": false
}
}
},
{
"description": "Canonical Ubuntu 18.04",
"product": {
"name": "N/A",
"vendor": {
"name": "VMware",
"scada": false
}
}
},
{
"description": "VMware Tanzu Application Service for VMs versions 2.13.x ant\u00e9rieures \u00e0 2.13.17",
"product": {
"name": "Tanzu",
"vendor": {
"name": "VMware",
"scada": false
}
}
},
{
"description": "Platform Automation Toolkit versions 4.0.x ant\u00e9rieures \u00e0 to 4.0.13",
"product": {
"name": "N/A",
"vendor": {
"name": "VMware",
"scada": false
}
}
},
{
"description": "VMware Tanzu Application Service for VMs versions 2.11.x ant\u00e9rieures \u00e0 2.11.35",
"product": {
"name": "Tanzu",
"vendor": {
"name": "VMware",
"scada": false
}
}
},
{
"description": "Platform Automation Toolkit versions 4.3.x versions ant\u00e9rieures \u00e0 4.3.5",
"product": {
"name": "N/A",
"vendor": {
"name": "VMware",
"scada": false
}
}
},
{
"description": "Platform Automation Toolkit versions 5.1.x versions ant\u00e9rieures \u00e0 5.1.0",
"product": {
"name": "N/A",
"vendor": {
"name": "VMware",
"scada": false
}
}
},
{
"description": "Operations Manager versions 3.0.x ant\u00e9rieures \u00e0 3.0.4",
"product": {
"name": "N/A",
"vendor": {
"name": "VMware",
"scada": false
}
}
},
{
"description": "Operations Manager versions 2.10.x ant\u00e9rieures \u00e0 2.10.51",
"product": {
"name": "N/A",
"vendor": {
"name": "VMware",
"scada": false
}
}
},
{
"description": "Isolation Segment versions 3.0.x ant\u00e9rieures \u00e0 3.0.7 (avec Jammy Stemcells versions ant\u00e9rieures \u00e0 1.80)",
"product": {
"name": "N/A",
"vendor": {
"name": "VMware",
"scada": false
}
}
},
{
"description": "Isolation Segment versions 2.11.x ant\u00e9rieures \u00e0 2.11.29",
"product": {
"name": "N/A",
"vendor": {
"name": "VMware",
"scada": false
}
}
},
{
"description": "Platform Automation Toolkit versions 4.2.x ant\u00e9rieures \u00e0 4.2.8",
"product": {
"name": "N/A",
"vendor": {
"name": "VMware",
"scada": false
}
}
},
{
"description": "Canonical Ubuntu 16.04",
"product": {
"name": "N/A",
"vendor": {
"name": "VMware",
"scada": false
}
}
},
{
"description": "Platform Automation Toolkit versions 4.4.x versions ant\u00e9rieures \u00e0 4.4.30",
"product": {
"name": "N/A",
"vendor": {
"name": "VMware",
"scada": false
}
}
},
{
"description": "Canonical Ubuntu 22.04",
"product": {
"name": "N/A",
"vendor": {
"name": "VMware",
"scada": false
}
}
},
{
"description": "VMware Tanzu Application Service for VMs versions 3.0.x ant\u00e9rieures \u00e0 3.0.7 (avec Jammy Stemcells versions 1.80)",
"product": {
"name": "Tanzu",
"vendor": {
"name": "VMware",
"scada": false
}
}
},
{
"description": "Platform Automation Toolkit versions 5.0.x versions ant\u00e9rieures \u00e0 5.0.23",
"product": {
"name": "N/A",
"vendor": {
"name": "VMware",
"scada": false
}
}
},
{
"description": "Isolation Segment versions 2.13.x ant\u00e9rieures \u00e0 2.13.14",
"product": {
"name": "N/A",
"vendor": {
"name": "VMware",
"scada": false
}
}
},
{
"description": "Tanzu Greenplum for Kubernetes versions ant\u00e9rieures \u00e0 1.4.0",
"product": {
"name": "Tanzu",
"vendor": {
"name": "VMware",
"scada": false
}
}
},
{
"description": "Platform Automation Toolkit versions 4.1.x ant\u00e9rieures \u00e0 4.1.13",
"product": {
"name": "N/A",
"vendor": {
"name": "VMware",
"scada": false
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2022-24809",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24809"
},
{
"name": "CVE-2022-47629",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-47629"
},
{
"name": "CVE-2022-24805",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24805"
},
{
"name": "CVE-2022-44792",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-44792"
},
{
"name": "CVE-2022-45061",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-45061"
},
{
"name": "CVE-2022-4883",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-4883"
},
{
"name": "CVE-2022-44793",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-44793"
},
{
"name": "CVE-2022-3165",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-3165"
},
{
"name": "CVE-2022-0417",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-0417"
},
{
"name": "CVE-2022-24807",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24807"
},
{
"name": "CVE-2022-24810",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24810"
},
{
"name": "CVE-2022-37454",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-37454"
},
{
"name": "CVE-2022-44617",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-44617"
},
{
"name": "CVE-2021-3682",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-3682"
},
{
"name": "CVE-2021-23222",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-23222"
},
{
"name": "CVE-2022-2962",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-2962"
},
{
"name": "CVE-2023-22809",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-22809"
},
{
"name": "CVE-2022-0392",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-0392"
},
{
"name": "CVE-2022-33070",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-33070"
},
{
"name": "CVE-2022-0216",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-0216"
},
{
"name": "CVE-2022-40898",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-40898"
},
{
"name": "CVE-2022-24806",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24806"
},
{
"name": "CVE-2022-46285",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-46285"
},
{
"name": "CVE-2021-3930",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-3930"
},
{
"name": "CVE-2021-33621",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-33621"
},
{
"name": "CVE-2022-24808",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24808"
},
{
"name": "CVE-2021-3750",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-3750"
}
],
"initial_release_date": "2023-04-17T00:00:00",
"last_revision_date": "2023-04-17T00:00:00",
"links": [],
"reference": "CERTFR-2023-AVI-0318",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2023-04-17T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
},
{
"description": "\u00c9l\u00e9vation de privil\u00e8ges"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans \u003cspan\nclass=\"textit\"\u003eVMware\u003c/span\u003e. Elles permettent \u00e0 un attaquant de\nprovoquer une ex\u00e9cution de code arbitraire \u00e0 distance, une \u00e9l\u00e9vation de\nprivil\u00e8ges, un d\u00e9ni de service \u00e0 distance et une atteinte \u00e0 la\nconfidentialit\u00e9 des donn\u00e9es.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits VMware",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 VMware USN-5795-1 du 13 avril 2023",
"url": "https://tanzu.vmware.com/security/usn-5787-1"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 VMware USN-5795-2 du 13 avril 2023",
"url": "https://tanzu.vmware.com/security/usn-5787-2"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 VMware USN-5787-2 du 13 avril 2023",
"url": "https://tanzu.vmware.com/security/usn-5772-1"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 VMware USN-5765-1 du 13 avril 2023",
"url": null
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 VMware USN-5821-1 du 13 avril 2023",
"url": "https://tanzu.vmware.com/security/usn-5821-1"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 VMware USN-5801-1 du 13 avril 2023",
"url": "https://tanzu.vmware.com/security/usn-5795-2"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 VMware USN-5811-1 du 13 avril 2023",
"url": "https://tanzu.vmware.com/security/usn-5811-1"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 VMware USN-5787-1 du 13 avril 2023",
"url": "https://tanzu.vmware.com/security/usn-5767-1"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 VMware USN-5806-1 du 13 avril 2023",
"url": "https://tanzu.vmware.com/security/usn-5801-1"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 VMware USN-5807-1 du 13 avril 2023",
"url": "https://tanzu.vmware.com/security/usn-5807-1"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 VMware USN-5787-1 du 12 avril 2023",
"url": "https://tanzu.vmware.com/security/usn-5765-1"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 VMware USN-5806-2 du 13 avril 2023",
"url": "https://tanzu.vmware.com/security/usn-5806-2"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 VMware USN-5772-1 du 13 avril 2023",
"url": null
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 VMware USN-5767-1 du 13 avril 2023",
"url": null
}
]
}
CERTFR-2023-AVI-0935
Vulnerability from certfr_avis - Published: 2023-11-14 - Updated: 2023-11-14
De multiples vulnérabilités ont été découvertes dans les produits Siemens. Certaines d'entre elles permettent à un attaquant de provoquer une élévation de privilèges, un déni de service à distance et une exécution de code arbitraire à distance.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| Siemens | N/A | RUGGEDCOM RSG920P V4.X versions antérieures à V4.3.8 | ||
| Siemens | N/A | SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0) toutes les versions | ||
| Siemens | N/A | SCALANCE XC208G (6GK5208-0GA00-2AC2) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0) toutes les versions | ||
| Siemens | N/A | SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0) toutes les versions | ||
| Siemens | N/A | SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0) toutes les versions | ||
| Siemens | N/A | SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0) toutes les versions | ||
| Siemens | N/A | Applications Mendix basées sur Mendix 10 versions antérieures à V10.4.0 | ||
| Siemens | N/A | RUGGEDCOM RS416PNC toutes les versions | ||
| Siemens | N/A | SCALANCE XB205-3LD (SC, E/IP) (6GK5205-3BF00-2TB2) versions antérieures à V4.5 | ||
| Siemens | N/A | SIPLUS NET SCALANCE XC206-2SFP (6AG1206-2BS00-7AC2) versions antérieures à V4.5 | ||
| Siemens | N/A | RUGGEDCOM RSG2200NC toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RS8000NC toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RSG2300PF toutes les versions | ||
| Siemens | N/A | SCALANCE XC206-2SFP EEC (6GK5206-2BS00-2FC2) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE XB205-3 (SC, PN) (6GK5205-3BB00-2AB2) versions antérieures à V4.5 | ||
| Siemens | N/A | RUGGEDCOM RS416Pv2 V4.X versions antérieures à V4.3.8 | ||
| Siemens | N/A | RUGGEDCOM RST2228P versions antérieures à V5.6.0 | ||
| Siemens | N/A | SCALANCE XC216-4C G EEC (6GK5216-4GS00-2FC2) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE XR328-4C WG (28xGE, AC 230V) (6GK5328-4SS00-3AR3) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE XC208EEC (6GK5208-0BA00-2FC2) versions antérieures à V4.5 | ||
| Siemens | N/A | RUGGEDCOM RSG2300P V5.X versions antérieures à V5.6.0 | ||
| Siemens | N/A | RUGGEDCOM RS969 versions antérieures à V4.3.8 | ||
| Siemens | N/A | SCALANCE W1788-2 M12 (6GK5788-2GY01-0AA0) toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RS940GNC toutes les versions | ||
| Siemens | N/A | SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0) toutes les versions | ||
| Siemens | N/A | Mendix Studio Pro 8 versions antérieures à V8.18.27 | ||
| Siemens | N/A | RUGGEDCOM RS900GNC toutes les versions | ||
| Siemens | N/A | RUGGEDCOM M2200F toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RSG2200F toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RS900LNC toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RS416PNCv2 V5.X toutes les versions | ||
| Siemens | N/A | SCALANCE XC216-4C G (EIP Def.) (6GK5216-4GS00-2TC2) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE XB205-3 (ST, PN) (6GK5205-3BD00-2AB2) versions antérieures à V4.5 | ||
| Siemens | N/A | Siemens OPC UA Modelling Editor (SiOME) versions antérieures à V2.8 | ||
| Siemens | N/A | SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0) toutes les versions | ||
| Siemens | N/A | SCALANCE XB205-3 (ST, E/IP) (6GK5205-3BD00-2TB2) versions antérieures à V4.5 | ||
| Siemens | N/A | RUGGEDCOM RSG2488NC V5.X toutes les versions | ||
| Siemens | N/A | SCALANCE XB205-3 (ST, E/IP) (6GK5205-3BB00-2TB2) versions antérieures à V4.5 | ||
| Siemens | N/A | RUGGEDCOM RS1600TNC toutes les versions | ||
| Siemens | N/A | SCALANCE XB213-3LD (SC, PN) (6GK5213-3BF00-2AB2) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0) toutes les versions | ||
| Siemens | N/A | SCALANCE XC216-3G PoE (6GK5216-3RS00-2AC2) versions antérieures à V4.5 | ||
| Siemens | N/A | RUGGEDCOM M2100 versions antérieures à V4.3.8 | ||
| Siemens | N/A | SCALANCE XC208 (6GK5208-0BA00-2AC2) versions antérieures à V4.5 | ||
| Siemens | N/A | RUGGEDCOM RSG2288NC V4.X toutes les versions | ||
| Siemens | N/A | SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0) toutes les versions | ||
| Siemens | N/A | SCALANCE XP216EEC (6GK5216-0HA00-2ES6) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE XC216-4C G (6GK5216-4GS00-2AC2) versions antérieures à V4.5 | ||
| Siemens | N/A | RUGGEDCOM RS900M-GETS-XX versions antérieures à V4.3.8 | ||
| Siemens | N/A | Mendix Studio Pro 10 versions antérieures à V10.3.1 | ||
| Siemens | N/A | SCALANCE XP216 (Ethernet/IP) (6GK5216-0HA00-2TS6) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE XP208EEC (6GK5208-0HA00-2ES6) versions antérieures à V4.5 | ||
| Siemens | N/A | RUGGEDCOM RS900MNC-GETS-C01 toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RS900NC(32M) V4.X toutes les versions | ||
| Siemens | N/A | RUGGEDCOM M2200 versions antérieures à V4.3.8 | ||
| Siemens | N/A | SCALANCE XP216 (6GK5216-0HA00-2AS6) versions antérieures à V4.5 | ||
| Siemens | N/A | RUGGEDCOM i801NC toutes les versions | ||
| Siemens | N/A | SCALANCE XR326-2C PoE WG (6GK5326-2QS00-3AR3) versions antérieures à V4.5 | ||
| Siemens | N/A | RUGGEDCOM RST916C versions antérieures à V5.6.0 | ||
| Siemens | N/A | RUGGEDCOM i800 versions antérieures à V4.3.8 | ||
| Siemens | N/A | RUGGEDCOM RSG2300NC V4.X toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RS910LNC toutes les versions | ||
| Siemens | N/A | Tecnomatix Plant Simulation V2302 versions antérieures à V2302.0004 | ||
| Siemens | N/A | RUGGEDCOM RS900GP versions antérieures à V4.3.8 | ||
| Siemens | N/A | RUGGEDCOM RS400 versions antérieures à V4.3.8 | ||
| Siemens | N/A | RUGGEDCOM RS900M-STND-C01 versions antérieures à V4.3.8 | ||
| Siemens | N/A | RUGGEDCOM RS940GF toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RS416F toutes les versions | ||
| Siemens | N/A | SCALANCE WUM766-1 (US) (6GK5766-1GE00-3DB0) toutes les versions | ||
| Siemens | N/A | SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0) toutes les versions | ||
| Siemens | N/A | SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0) toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RSG2100 (32M) V4.X versions antérieures à V4.3.8 | ||
| Siemens | N/A | RUGGEDCOM RSG2300 V4.X versions antérieures à V4.3.8 | ||
| Siemens | N/A | RUGGEDCOM RS900 (32M) V5.X versions antérieures à V5.6.0 | ||
| Siemens | N/A | SCALANCE XC206-2 (ST/BFOC) (6GK5206-2BB00-2AC2) versions antérieures à V4.5 | ||
| Siemens | N/A | RUGGEDCOM RS900G versions antérieures à V4.3.8 | ||
| Siemens | N/A | SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0) toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RMC8388NC V5.X toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RMC8388NC V4.X toutes les versions | ||
| Siemens | N/A | SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0) toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RS900GF toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RSG2288 V4.X versions antérieures à V4.3.8 | ||
| Siemens | N/A | SINEC PNI versions antérieures à V2.0 | ||
| Siemens | N/A | SCALANCE XC206-2G PoE EEC (54 V DC) (6GK5206-2RS00-5FC2) versions antérieures à V4.5 | ||
| Siemens | N/A | RUGGEDCOM RSG2488NC V4.X toutes les versions | ||
| Siemens | N/A | Desigo CC product family V7 toutes les versions sans le dernier correctif de sécurité | ||
| Siemens | N/A | SCALANCE XC206-2SFP G (EIP DEF.) (6GK5206-2GS00-2TC2) versions antérieures à V4.5 | ||
| Siemens | N/A | RUGGEDCOM RS8000TNC toutes les versions | ||
| Siemens | N/A | SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0) toutes les versions | ||
| Siemens | N/A | SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0) toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RS400NC toutes les versions | ||
| Siemens | N/A | SCALANCE XF204 DNA (6GK5204-0BA00-2YF2) versions antérieures à V4.5 | ||
| Siemens | N/A | RUGGEDCOM i803NC toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RS910W versions antérieures à V4.3.8 | ||
| Siemens | N/A | SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) (6GK5328-4FS00-3RR3) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE XC216-4C (6GK5216-4BS00-2AC2) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE XC224-4C G (6GK5224-4GS00-2AC2) versions antérieures à V4.5 | ||
| Siemens | N/A | RUGGEDCOM RS416NCv2 V4.X toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RSG2100F toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RSG2100PF toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RS1600T versions antérieures à V4.3.8 | ||
| Siemens | N/A | SCALANCE XC206-2G PoE (6GK5206-2RS00-2AC2) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE XC208G EEC (6GK5208-0GA00-2FC2) versions antérieures à V4.5 | ||
| Siemens | N/A | Desigo CC product family V5.0 toutes les versions sans le dernier correctif de sécurité | ||
| Siemens | N/A | SCALANCE XC206-2SFP (6GK5206-2BS00-2AC2) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0) toutes les versions | ||
| Siemens | N/A | SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0) toutes les versions | ||
| Siemens | N/A | SCALANCE XB205-3LD (SC, PN) (6GK5205-3BF00-2AB2) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE XR328-4C WG (24XFE, 4XGE, 24V) (6GK5328-4FS00-2AR3) versions antérieures à V4.5 | ||
| Siemens | N/A | RUGGEDCOM RSG2300PNC V4.X toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RSG2300P V4.X versions antérieures à V4.3.8 | ||
| Siemens | N/A | RUGGEDCOM RMC30 versions antérieures à V4.3.8 | ||
| Siemens | N/A | RUGGEDCOM RS920W versions antérieures à V4.3.8 | ||
| Siemens | N/A | RUGGEDCOM RS416PF toutes les versions | ||
| Siemens | N/A | RUGGEDCOM i803 versions antérieures à V4.3.8 | ||
| Siemens | N/A | RUGGEDCOM APE1808 toutes versions utilisées avec Nozomi Guardian / CMC versions V22.6.3 à 23.1.0sans le dernier correctif de sécurité | ||
| Siemens | N/A | Applications Mendix basées sur Mendix 7.x versions antérieures à V7.23.37 | ||
| Siemens | N/A | RUGGEDCOM RSG908C versions antérieures à V5.6.0 | ||
| Siemens | N/A | Applications Mendix basées sur Mendix 9.x versions antérieures à V9.24.10 | ||
| Siemens | N/A | RUGGEDCOM RSG920P V5.X versions antérieures à V5.6.0 | ||
| Siemens | N/A | RUGGEDCOM RS900W versions antérieures à V4.3.8 | ||
| Siemens | N/A | SCALANCE XF204-2BA (6GK5204-2AA00-2GF2) versions antérieures à V4.5 | ||
| Siemens | N/A | RUGGEDCOM RS401NC toutes les versions | ||
| Siemens | N/A | SCALANCE XC216-3G PoE (54 V DC) (6GK5216-3RS00-5AC2) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0) toutes les versions | ||
| Siemens | N/A | SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0) toutes les versions | ||
| Siemens | N/A | SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0) toutes les versions | ||
| Siemens | N/A | SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0) toutes les versions | ||
| Siemens | N/A | SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0) toutes les versions | ||
| Siemens | N/A | Desigo CC product family V5.1 toutes les versions sans le dernier correctif de sécurité | ||
| Siemens | N/A | SCALANCE XC224 (6GK5224-0BA00-2AC2) versions antérieures à V4.5 | ||
| Siemens | N/A | RUGGEDCOM RS900MNC-STND-XX toutes les versions | ||
| Siemens | N/A | SIMATIC MV500 family versions antérieures à V3.3.5 | ||
| Siemens | N/A | RUGGEDCOM RST916P versions antérieures à V5.6.0 | ||
| Siemens | N/A | RUGGEDCOM RS401 versions antérieures à V4.3.8 | ||
| Siemens | N/A | SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V) (6GK5328-4FS00-2RR3) versions antérieures à V4.5 | ||
| Siemens | N/A | RUGGEDCOM RSG2488 V4.X versions antérieures à V4.3.8 | ||
| Siemens | N/A | RUGGEDCOM RS910 versions antérieures à V4.3.8 | ||
| Siemens | N/A | SCALANCE XC224-4C G EEC (6GK5224-4GS00-2FC2) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE WUM763-1 (6GK5763-1AL00-3DA0) toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RS416v2 V4.X versions antérieures à V4.3.8 | ||
| Siemens | N/A | RUGGEDCOM RSG2488F toutes les versions | ||
| Siemens | N/A | SCALANCE XC216EEC (6GK5216-0BA00-2FC2) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) (6GK5328-4FS00-3AR3) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE XB213-3LD (SC, E/IP) (6GK5213-3BF00-2TB2) versions antérieures à V4.5 | ||
| Siemens | N/A | RUGGEDCOM RS900GNC(32M) V4.X toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RST2228 versions antérieures à V5.6.0 | ||
| Siemens | N/A | RUGGEDCOM RS416P versions antérieures à V4.3.8 | ||
| Siemens | N/A | RUGGEDCOM RSG2288NC V5.X toutes les versions | ||
| Siemens | N/A | SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0) toutes les versions | ||
| Siemens | N/A | RUGGEDCOM M2100F toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RS8000 versions antérieures à V4.3.8 | ||
| Siemens | N/A | Applications Mendix basées sur Mendix 8.x versions antérieures à V8.18.27 | ||
| Siemens | N/A | SCALANCE XC206-2SFP G (6GK5206-2GS00-2AC2) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE W1748-1 M12 (6GK5748-1GY01-0TA0) toutes les versions | ||
| Siemens | N/A | SCALANCE XB213-3 (SC, E/IP) (6GK5213-3BD00-2TB2) versions antérieures à V4.5 | ||
| Siemens | N/A | RUGGEDCOM RS900NC toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RP110NC toutes les versions | ||
| Siemens | N/A | SCALANCE XR324WG (24 x FE, AC 230V) (6GK5324-0BA00-3AR3) versions antérieures à V4.5 | ||
| Siemens | N/A | RUGGEDCOM RSG2100P versions antérieures à V4.3.8 | ||
| Siemens | N/A | SIPLUS NET SCALANCE XC206-2 (6AG1206-2BB00-7AC2) versions antérieures à V4.5 | ||
| Siemens | N/A | RUGGEDCOM M969F toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RS900GPF toutes les versions | ||
| Siemens | N/A | SCALANCE XR324WG (24 X FE, DC 24V) (6GK5324-0BA00-2AR3) versions antérieures à V4.5 | ||
| Siemens | N/A | RUGGEDCOM RSG907R versions antérieures à V5.6.0 | ||
| Siemens | N/A | RUGGEDCOM i802 versions antérieures à V4.3.8 | ||
| Siemens | N/A | RUGGEDCOM M969 versions antérieures à V4.3.8 | ||
| Siemens | N/A | RUGGEDCOM RSG920PNC V5.X toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RS920L versions antérieures à V4.3.8 | ||
| Siemens | N/A | RUGGEDCOM RS900MNC-STND-XX-C01 toutes les versions | ||
| Siemens | N/A | SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0) toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RS900F toutes les versions | ||
| Siemens | N/A | SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6) toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RS900G (32M) V5.X versions antérieures à V5.6.0 | ||
| Siemens | N/A | SCALANCE W1788-2 EEC M12 (6GK5788-2GY01-0TA0) toutes les versions | ||
| Siemens | N/A | SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0) toutes les versions | ||
| Siemens | N/A | Simcenter Femap V2301 versions antérieures à V2301.0003 | ||
| Siemens | N/A | RUGGEDCOM RSG2100NC(32M) V4.X toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RSG2288 V5.X versions antérieures à V5.6.0 | ||
| Siemens | N/A | RUGGEDCOM RSG920PNC V4.X toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RS8000H versions antérieures à V4.3.8 | ||
| Siemens | N/A | SCALANCE WUM763-1 (6GK5763-1AL00-3AA0) toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RMC8388 V5.X versions antérieures à V5.6.0 | ||
| Siemens | N/A | RUGGEDCOM RSG910C versions antérieures à V5.6.0 | ||
| Siemens | N/A | SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0) toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RSG909R versions antérieures à V5.6.0 | ||
| Siemens | N/A | SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0) toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RS416PNCv2 V4.X toutes les versions | ||
| Siemens | N/A | SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0) toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RS910NC toutes les versions | ||
| Siemens | N/A | SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6) toutes les versions | ||
| Siemens | N/A | SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0) toutes les versions | ||
| Siemens | N/A | SCALANCE XB216 (PN) (6GK5216-0BA00-2AB2) versions antérieures à V4.5 | ||
| Siemens | N/A | Desigo CC product family V6 toutes les versions sans le dernier correctif de sécurité | ||
| Siemens | N/A | RUGGEDCOM RS416Pv2 V5.X versions antérieures à V5.6.0 | ||
| Siemens | N/A | SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6) toutes les versions | ||
| Siemens | N/A | RUGGEDCOM i800NC toutes les versions | ||
| Siemens | N/A | SCALANCE XC206-2G PoE (54 V DC) (6GK5206-2RS00-5AC2) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0) toutes les versions | ||
| Siemens | N/A | SCALANCE XB213-3 (ST, E/IP) (6GK5213-3BB00-2TB2) versions antérieures à V4.5 | ||
| Siemens | N/A | RUGGEDCOM RS930LNC toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RMC8388 V4.X versions antérieures à V4.3.8 | ||
| Siemens | N/A | SIMATIC PCS neo versions antérieures à V4.1 | ||
| Siemens | N/A | RUGGEDCOM RS900M-STND-XX versions antérieures à V4.3.8 | ||
| Siemens | N/A | RUGGEDCOM RS910L versions antérieures à V4.3.8 | ||
| Siemens | N/A | SCALANCE XC206-2SFP G EEC (6GK5206-2GS00-2FC2) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE XB208 (PN) (6GK5208-0BA00-2AB2) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6) toutes les versions | ||
| Siemens | N/A | RUGGEDCOM i802NC toutes les versions | ||
| Siemens | N/A | SIPLUS NET SCALANCE XC208 (6AG1208-0BA00-7AC2) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0) toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RS1600FNC toutes les versions | ||
| Siemens | N/A | SCALANCE W1748-1 M12 (6GK5748-1GY01-0AA0) toutes les versions | ||
| Siemens | N/A | SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0) toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RSG2100PNC toutes les versions | ||
| Siemens | N/A | SCALANCE XP208 (Ethernet/IP) (6GK5208-0HA00-2TS6) versions antérieures à V4.5 | ||
| Siemens | N/A | RUGGEDCOM RS400F toutes les versions | ||
| Siemens | N/A | Mendix Studio Pro 7 versions antérieures à V7.23.37 | ||
| Siemens | N/A | RUGGEDCOM RSG2100 versions antérieures à V4.3.8 | ||
| Siemens | N/A | RUGGEDCOM RS8000A versions antérieures à V4.3.8 | ||
| Siemens | N/A | RUGGEDCOM RS900L versions antérieures à V4.3.8 | ||
| Siemens | N/A | SCALANCE XB208 (E/IP) (6GK5208-0BA00-2TB2) versions antérieures à V4.5 | ||
| Siemens | N/A | RUGGEDCOM RS920LNC toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RS8000T versions antérieures à V4.3.8 | ||
| Siemens | N/A | SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0) toutes les versions | ||
| Siemens | N/A | SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0) toutes les versions | ||
| Siemens | N/A | SIPLUS NET SCALANCE XC216-4C (6AG1216-4BS00-7AC2) versions antérieures à V4.5 | ||
| Siemens | N/A | RUGGEDCOM RMC30NC toutes les versions | ||
| Siemens | N/A | COMOS versions antérieures à V10.4.4, les vulnérabilités CVE-2023-43505, CVE-2023-46601 ne seront pas corrigées par l'éditeur | ||
| Siemens | N/A | RUGGEDCOM RS900GNC(32M) V5.X toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RSG2488 V5.X versions antérieures à V5.6.0 | ||
| Siemens | N/A | RUGGEDCOM RS8000ANC toutes les versions | ||
| Siemens | N/A | SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0) toutes les versions | ||
| Siemens | N/A | SCALANCE XC216 (6GK5216-0BA00-2AC2) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0) toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RS930L versions antérieures à V4.3.8 | ||
| Siemens | N/A | SCALANCE XB216 (E/IP) (6GK5216-0BA00-2TB2) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0) toutes les versions | ||
| Siemens | N/A | SCALANCE WUM766-1 (EU) (6GK5766-1GE00-3DA0) toutes les versions | ||
| Siemens | N/A | SCALANCE WAM766-1 EEC (EU) (6GK5766-1GE00-7TA0) toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RSL910NC toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RSG2300 V5.X versions antérieures à V5.6.0 | ||
| Siemens | N/A | RUGGEDCOM RSG2300PNC V5.X toutes les versions | ||
| Siemens | N/A | RUGGEDCOM i801 versions antérieures à V4.3.8 | ||
| Siemens | N/A | Mendix Studio Pro 9 versions antérieures à V9.24.0 | ||
| Siemens | N/A | RUGGEDCOM M2100NC toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RS416NCv2 V5.X toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RSG2100NC toutes les versions | ||
| Siemens | N/A | SCALANCE XR326-2C PoE WG (without UL) (6GK5326-2QS00-3RR3) versions antérieures à V4.5 | ||
| Siemens | N/A | RUGGEDCOM RS900M-GETS-C01 versions antérieures à V4.3.8 | ||
| Siemens | N/A | RUGGEDCOM RS969NC toutes les versions | ||
| Siemens | N/A | SCALANCE XP208 (6GK5208-0HA00-2AS6) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0) toutes les versions | ||
| Siemens | N/A | SCALANCE XR328-4C WG (28xGE, DC 24V) (6GK5328-4SS00-2AR3) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE XC208G PoE (6GK5208-0RA00-2AC2) versions antérieures à V4.5 | ||
| Siemens | N/A | RUGGEDCOM RS900G (32M) V4.X versions antérieures à V4.3.8 | ||
| Siemens | N/A | Tecnomatix Plant Simulation V2201 versions antérieures à V2201.0010 | ||
| Siemens | N/A | SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0) toutes les versions | ||
| Siemens | N/A | SCALANCE W1788-2IA M12 (6GK5788-2HY01-0AA0) toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RS900 versions antérieures à V4.3.8 | ||
| Siemens | N/A | SCALANCE XP216POE EEC (6GK5216-0UA00-5ES6) versions antérieures à V4.5 | ||
| Siemens | N/A | RUGGEDCOM RS8000HNC toutes les versions | ||
| Siemens | N/A | SCALANCE XB213-3 (SC, PN) (6GK5213-3BD00-2AB2) versions antérieures à V4.5 | ||
| Siemens | N/A | Simcenter Femap V2306 versions antérieures à V2306.0001 | ||
| Siemens | N/A | RUGGEDCOM RP110 versions antérieures à V4.3.8 | ||
| Siemens | N/A | RUGGEDCOM RS900 (32M) V4.X versions antérieures à V4.3.8 | ||
| Siemens | N/A | RUGGEDCOM RSG2100 (32M) V5.X versions antérieures à V5.6.0 | ||
| Siemens | N/A | SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0) toutes les versions | ||
| Siemens | N/A | SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0) toutes les versions | ||
| Siemens | N/A | RUGGEDCOM M969NC toutes les versions | ||
| Siemens | N/A | SCALANCE XC208G PoE (54 V DC) (6GK5208-0RA00-5AC2) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE XC224-4C G (EIP Def.) (6GK5224-4GS00-2TC2) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE XC206-2 (SC) (6GK5206-2BD00-2AC2) versions antérieures à V4.5 | ||
| Siemens | N/A | RUGGEDCOM RSL910 versions antérieures à V5.6.0 | ||
| Siemens | N/A | RUGGEDCOM RS1600F versions antérieures à V4.3.8 | ||
| Siemens | N/A | RUGGEDCOM RS900NC(32M) V5.X toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RS416 versions antérieures à V4.3.8 | ||
| Siemens | N/A | SCALANCE W1788-1 M12 (6GK5788-1GY01-0AA0) toutes les versions | ||
| Siemens | N/A | SCALANCE WAM763-1 (6GK5763-1AL00-7DA0) toutes les versions | ||
| Siemens | N/A | SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0) toutes les versions | ||
| Siemens | N/A | SCALANCE XF204 (6GK5204-0BA00-2GF2) versions antérieures à V4.5 | ||
| Siemens | N/A | RUGGEDCOM RSG2300NC V5.X toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RS900MNC-GETS-XX toutes les versions | ||
| Siemens | N/A | SCALANCE XB213-3 (ST, PN) (6GK5213-3BB00-2AB2) versions antérieures à V4.5 | ||
| Siemens | N/A | RUGGEDCOM RS930W versions antérieures à V4.3.8 | ||
| Siemens | N/A | RUGGEDCOM M2200NC toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RS416v2 V5.X versions antérieures à V5.6.0 | ||
| Siemens | N/A | RUGGEDCOM RS900GPNC toutes les versions | ||
| Siemens | N/A | SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0) toutes les versions | ||
| Siemens | N/A | SCALANCE XP208PoE EEC (6GK5208-0UA00-5ES6) versions antérieures à V4.5 | ||
| Siemens | N/A | RUGGEDCOM RS1600 versions antérieures à V4.3.8 | ||
| Siemens | N/A | RUGGEDCOM RS940G versions antérieures à V4.3.8 | ||
| Siemens | N/A | SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0) toutes les versions | ||
| Siemens | N/A | SIPROTEC 4 7SJ66 versions antérieures à V4.41 | ||
| Siemens | N/A | RUGGEDCOM RSG2300F toutes les versions | ||
| Siemens | N/A | SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0) toutes les versions | ||
| Siemens | N/A | SCALANCE XC208G (EIP def.) (6GK5208-0GA00-2TC2) versions antérieures à V4.5 | ||
| Siemens | N/A | RUGGEDCOM RS1600NC toutes les versions | ||
| Siemens | N/A | SCALANCE XF204-2BA DNA (6GK5204-2AA00-2YF2) versions antérieures à V4.5 | ||
| Siemens | N/A | RUGGEDCOM RSG2100NC(32M) V5.X toutes les versions | ||
| Siemens | N/A | SCALANCE WAM766-1 (EU) (6GK5766-1GE00-7DA0) toutes les versions | ||
| Siemens | N/A | SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0) toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RS416NC toutes les versions | ||
| Siemens | N/A | SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0) toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RSG2200 versions antérieures à V4.3.8 |
| Title | Publication Time | Tags | |||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||||||||||||||||||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "RUGGEDCOM RSG920P V4.X versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XC208G (6GK5208-0GA00-2AC2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Applications Mendix bas\u00e9es sur Mendix 10 versions ant\u00e9rieures \u00e0 V10.4.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS416PNC toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XB205-3LD (SC, E/IP) (6GK5205-3BF00-2TB2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS NET SCALANCE XC206-2SFP (6AG1206-2BS00-7AC2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RSG2200NC toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS8000NC toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RSG2300PF toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XC206-2SFP EEC (6GK5206-2BS00-2FC2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XB205-3 (SC, PN) (6GK5205-3BB00-2AB2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS416Pv2 V4.X versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RST2228P versions ant\u00e9rieures \u00e0 V5.6.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XC216-4C G EEC (6GK5216-4GS00-2FC2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XR328-4C WG (28xGE, AC 230V) (6GK5328-4SS00-3AR3) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XC208EEC (6GK5208-0BA00-2FC2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RSG2300P V5.X versions ant\u00e9rieures \u00e0 V5.6.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS969 versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W1788-2 M12 (6GK5788-2GY01-0AA0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS940GNC toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Mendix Studio Pro 8 versions ant\u00e9rieures \u00e0 V8.18.27",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS900GNC toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM M2200F toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RSG2200F toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS900LNC toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS416PNCv2 V5.X toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XC216-4C G (EIP Def.) (6GK5216-4GS00-2TC2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XB205-3 (ST, PN) (6GK5205-3BD00-2AB2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Siemens OPC UA Modelling Editor (SiOME) versions ant\u00e9rieures \u00e0 V2.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XB205-3 (ST, E/IP) (6GK5205-3BD00-2TB2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RSG2488NC V5.X toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XB205-3 (ST, E/IP) (6GK5205-3BB00-2TB2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS1600TNC toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XB213-3LD (SC, PN) (6GK5213-3BF00-2AB2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XC216-3G PoE (6GK5216-3RS00-2AC2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM M2100 versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XC208 (6GK5208-0BA00-2AC2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RSG2288NC V4.X toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XP216EEC (6GK5216-0HA00-2ES6) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XC216-4C G (6GK5216-4GS00-2AC2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS900M-GETS-XX versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Mendix Studio Pro 10 versions ant\u00e9rieures \u00e0 V10.3.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XP216 (Ethernet/IP) (6GK5216-0HA00-2TS6) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XP208EEC (6GK5208-0HA00-2ES6) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS900MNC-GETS-C01 toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS900NC(32M) V4.X toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM M2200 versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XP216 (6GK5216-0HA00-2AS6) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM i801NC toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XR326-2C PoE WG (6GK5326-2QS00-3AR3) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RST916C versions ant\u00e9rieures \u00e0 V5.6.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM i800 versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RSG2300NC V4.X toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS910LNC toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Tecnomatix Plant Simulation V2302 versions ant\u00e9rieures \u00e0 V2302.0004",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS900GP versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS400 versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS900M-STND-C01 versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS940GF toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS416F toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE WUM766-1 (US) (6GK5766-1GE00-3DB0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RSG2100 (32M) V4.X versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RSG2300 V4.X versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS900 (32M) V5.X versions ant\u00e9rieures \u00e0 V5.6.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XC206-2 (ST/BFOC) (6GK5206-2BB00-2AC2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS900G versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RMC8388NC V5.X toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RMC8388NC V4.X toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS900GF toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RSG2288 V4.X versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINEC PNI versions ant\u00e9rieures \u00e0 V2.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XC206-2G PoE EEC (54 V DC) (6GK5206-2RS00-5FC2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RSG2488NC V4.X toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Desigo CC product family V7 toutes les versions sans le dernier correctif de s\u00e9curit\u00e9",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XC206-2SFP G (EIP DEF.) (6GK5206-2GS00-2TC2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS8000TNC toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS400NC toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XF204 DNA (6GK5204-0BA00-2YF2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM i803NC toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS910W versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) (6GK5328-4FS00-3RR3) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XC216-4C (6GK5216-4BS00-2AC2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XC224-4C G (6GK5224-4GS00-2AC2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS416NCv2 V4.X toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RSG2100F toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RSG2100PF toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS1600T versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XC206-2G PoE (6GK5206-2RS00-2AC2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XC208G EEC (6GK5208-0GA00-2FC2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Desigo CC product family V5.0 toutes les versions sans le dernier correctif de s\u00e9curit\u00e9",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XC206-2SFP (6GK5206-2BS00-2AC2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XB205-3LD (SC, PN) (6GK5205-3BF00-2AB2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XR328-4C WG (24XFE, 4XGE, 24V) (6GK5328-4FS00-2AR3) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RSG2300PNC V4.X toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RSG2300P V4.X versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RMC30 versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS920W versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS416PF toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM i803 versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM APE1808 toutes versions utilis\u00e9es avec Nozomi Guardian / CMC versions V22.6.3 \u00e0 23.1.0sans le dernier correctif de s\u00e9curit\u00e9",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Applications Mendix bas\u00e9es sur Mendix 7.x versions ant\u00e9rieures \u00e0 V7.23.37",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RSG908C versions ant\u00e9rieures \u00e0 V5.6.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Applications Mendix bas\u00e9es sur Mendix 9.x versions ant\u00e9rieures \u00e0 V9.24.10",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RSG920P V5.X versions ant\u00e9rieures \u00e0 V5.6.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS900W versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XF204-2BA (6GK5204-2AA00-2GF2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS401NC toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XC216-3G PoE (54 V DC) (6GK5216-3RS00-5AC2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Desigo CC product family V5.1 toutes les versions sans le dernier correctif de s\u00e9curit\u00e9",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XC224 (6GK5224-0BA00-2AC2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS900MNC-STND-XX toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC MV500 family versions ant\u00e9rieures \u00e0 V3.3.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RST916P versions ant\u00e9rieures \u00e0 V5.6.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS401 versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V) (6GK5328-4FS00-2RR3) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RSG2488 V4.X versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS910 versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XC224-4C G EEC (6GK5224-4GS00-2FC2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE WUM763-1 (6GK5763-1AL00-3DA0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS416v2 V4.X versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RSG2488F toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XC216EEC (6GK5216-0BA00-2FC2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) (6GK5328-4FS00-3AR3) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XB213-3LD (SC, E/IP) (6GK5213-3BF00-2TB2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS900GNC(32M) V4.X toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RST2228 versions ant\u00e9rieures \u00e0 V5.6.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS416P versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RSG2288NC V5.X toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM M2100F toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS8000 versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Applications Mendix bas\u00e9es sur Mendix 8.x versions ant\u00e9rieures \u00e0 V8.18.27",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XC206-2SFP G (6GK5206-2GS00-2AC2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W1748-1 M12 (6GK5748-1GY01-0TA0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XB213-3 (SC, E/IP) (6GK5213-3BD00-2TB2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS900NC toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RP110NC toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XR324WG (24 x FE, AC 230V) (6GK5324-0BA00-3AR3) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RSG2100P versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS NET SCALANCE XC206-2 (6AG1206-2BB00-7AC2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM M969F toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS900GPF toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XR324WG (24 X FE, DC 24V) (6GK5324-0BA00-2AR3) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RSG907R versions ant\u00e9rieures \u00e0 V5.6.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM i802 versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM M969 versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RSG920PNC V5.X toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS920L versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS900MNC-STND-XX-C01 toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS900F toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS900G (32M) V5.X versions ant\u00e9rieures \u00e0 V5.6.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W1788-2 EEC M12 (6GK5788-2GY01-0TA0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Simcenter Femap V2301 versions ant\u00e9rieures \u00e0 V2301.0003",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RSG2100NC(32M) V4.X toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RSG2288 V5.X versions ant\u00e9rieures \u00e0 V5.6.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RSG920PNC V4.X toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS8000H versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE WUM763-1 (6GK5763-1AL00-3AA0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RMC8388 V5.X versions ant\u00e9rieures \u00e0 V5.6.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RSG910C versions ant\u00e9rieures \u00e0 V5.6.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RSG909R versions ant\u00e9rieures \u00e0 V5.6.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS416PNCv2 V4.X toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS910NC toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XB216 (PN) (6GK5216-0BA00-2AB2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Desigo CC product family V6 toutes les versions sans le dernier correctif de s\u00e9curit\u00e9",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS416Pv2 V5.X versions ant\u00e9rieures \u00e0 V5.6.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM i800NC toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XC206-2G PoE (54 V DC) (6GK5206-2RS00-5AC2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XB213-3 (ST, E/IP) (6GK5213-3BB00-2TB2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS930LNC toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RMC8388 V4.X versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC PCS neo versions ant\u00e9rieures \u00e0 V4.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS900M-STND-XX versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS910L versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XC206-2SFP G EEC (6GK5206-2GS00-2FC2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XB208 (PN) (6GK5208-0BA00-2AB2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM i802NC toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS NET SCALANCE XC208 (6AG1208-0BA00-7AC2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS1600FNC toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W1748-1 M12 (6GK5748-1GY01-0AA0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RSG2100PNC toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XP208 (Ethernet/IP) (6GK5208-0HA00-2TS6) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS400F toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Mendix Studio Pro 7 versions ant\u00e9rieures \u00e0 V7.23.37",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RSG2100 versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS8000A versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS900L versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XB208 (E/IP) (6GK5208-0BA00-2TB2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS920LNC toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS8000T versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS NET SCALANCE XC216-4C (6AG1216-4BS00-7AC2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RMC30NC toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "COMOS versions ant\u00e9rieures \u00e0 V10.4.4, les vuln\u00e9rabilit\u00e9s CVE-2023-43505, CVE-2023-46601 ne seront pas corrig\u00e9es par l\u0027\u00e9diteur",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS900GNC(32M) V5.X toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RSG2488 V5.X versions ant\u00e9rieures \u00e0 V5.6.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS8000ANC toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XC216 (6GK5216-0BA00-2AC2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS930L versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XB216 (E/IP) (6GK5216-0BA00-2TB2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE WUM766-1 (EU) (6GK5766-1GE00-3DA0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE WAM766-1 EEC (EU) (6GK5766-1GE00-7TA0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RSL910NC toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RSG2300 V5.X versions ant\u00e9rieures \u00e0 V5.6.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RSG2300PNC V5.X toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM i801 versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Mendix Studio Pro 9 versions ant\u00e9rieures \u00e0 V9.24.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM M2100NC toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS416NCv2 V5.X toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RSG2100NC toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XR326-2C PoE WG (without UL) (6GK5326-2QS00-3RR3) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS900M-GETS-C01 versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS969NC toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XP208 (6GK5208-0HA00-2AS6) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XR328-4C WG (28xGE, DC 24V) (6GK5328-4SS00-2AR3) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XC208G PoE (6GK5208-0RA00-2AC2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS900G (32M) V4.X versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Tecnomatix Plant Simulation V2201 versions ant\u00e9rieures \u00e0 V2201.0010",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W1788-2IA M12 (6GK5788-2HY01-0AA0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS900 versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XP216POE EEC (6GK5216-0UA00-5ES6) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS8000HNC toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XB213-3 (SC, PN) (6GK5213-3BD00-2AB2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Simcenter Femap V2306 versions ant\u00e9rieures \u00e0 V2306.0001",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RP110 versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS900 (32M) V4.X versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RSG2100 (32M) V5.X versions ant\u00e9rieures \u00e0 V5.6.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM M969NC toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XC208G PoE (54 V DC) (6GK5208-0RA00-5AC2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XC224-4C G (EIP Def.) (6GK5224-4GS00-2TC2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XC206-2 (SC) (6GK5206-2BD00-2AC2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RSL910 versions ant\u00e9rieures \u00e0 V5.6.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS1600F versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS900NC(32M) V5.X toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS416 versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W1788-1 M12 (6GK5788-1GY01-0AA0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE WAM763-1 (6GK5763-1AL00-7DA0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XF204 (6GK5204-0BA00-2GF2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RSG2300NC V5.X toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS900MNC-GETS-XX toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XB213-3 (ST, PN) (6GK5213-3BB00-2AB2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS930W versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM M2200NC toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS416v2 V5.X versions ant\u00e9rieures \u00e0 V5.6.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS900GPNC toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XP208PoE EEC (6GK5208-0UA00-5ES6) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS1600 versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS940G versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPROTEC 4 7SJ66 versions ant\u00e9rieures \u00e0 V4.41",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RSG2300F toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XC208G (EIP def.) (6GK5208-0GA00-2TC2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS1600NC toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XF204-2BA DNA (6GK5204-2AA00-2YF2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RSG2100NC(32M) V5.X toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE WAM766-1 (EU) (6GK5766-1GE00-7DA0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS416NC toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RSG2200 versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2023-24895",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-24895"
},
{
"name": "CVE-2023-0216",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-0216"
},
{
"name": "CVE-2020-35460",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-35460"
},
{
"name": "CVE-2023-0401",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-0401"
},
{
"name": "CVE-2023-33135",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-33135"
},
{
"name": "CVE-2023-1530",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-1530"
},
{
"name": "CVE-2023-22669",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-22669"
},
{
"name": "CVE-2023-44321",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-44321"
},
{
"name": "CVE-2023-3935",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-3935"
},
{
"name": "CVE-2023-46096",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-46096"
},
{
"name": "CVE-2023-44317",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-44317"
},
{
"name": "CVE-2022-4304",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-4304"
},
{
"name": "CVE-2023-38072",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-38072"
},
{
"name": "CVE-2023-24897",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-24897"
},
{
"name": "CVE-2022-44792",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-44792"
},
{
"name": "CVE-2023-3817",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-3817"
},
{
"name": "CVE-2023-38075",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-38075"
},
{
"name": "CVE-2019-12256",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-12256"
},
{
"name": "CVE-2023-35788",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-35788"
},
{
"name": "CVE-2022-28809",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-28809"
},
{
"name": "CVE-2023-24936",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-24936"
},
{
"name": "CVE-2023-38073",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-38073"
},
{
"name": "CVE-2023-46097",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-46097"
},
{
"name": "CVE-2019-12258",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-12258"
},
{
"name": "CVE-2020-25020",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-25020"
},
{
"name": "CVE-2022-4203",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-4203"
},
{
"name": "CVE-2022-44793",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-44793"
},
{
"name": "CVE-2023-33128",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-33128"
},
{
"name": "CVE-2019-12259",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-12259"
},
{
"name": "CVE-2023-0217",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-0217"
},
{
"name": "CVE-2023-44320",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-44320"
},
{
"name": "CVE-2022-39158",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-39158"
},
{
"name": "CVE-2022-28808",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-28808"
},
{
"name": "CVE-2019-12261",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-12261"
},
{
"name": "CVE-2023-46099",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-46099"
},
{
"name": "CVE-2023-46590",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-46590"
},
{
"name": "CVE-2023-2932",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-2932"
},
{
"name": "CVE-2023-41033",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-41033"
},
{
"name": "CVE-2023-46098",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-46098"
},
{
"name": "CVE-2022-37434",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-37434"
},
{
"name": "CVE-2021-20094",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-20094"
},
{
"name": "CVE-2022-28807",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-28807"
},
{
"name": "CVE-2023-38071",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-38071"
},
{
"name": "CVE-2023-45794",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-45794"
},
{
"name": "CVE-2019-12263",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-12263"
},
{
"name": "CVE-2021-20093",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-20093"
},
{
"name": "CVE-2023-44319",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-44319"
},
{
"name": "CVE-2023-46601",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-46601"
},
{
"name": "CVE-2023-32032",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-32032"
},
{
"name": "CVE-2022-4450",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-4450"
},
{
"name": "CVE-2023-2650",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-2650"
},
{
"name": "CVE-2022-47522",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-47522"
},
{
"name": "CVE-2023-38070",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-38070"
},
{
"name": "CVE-2022-23095",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-23095"
},
{
"name": "CVE-2023-44322",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-44322"
},
{
"name": "CVE-2023-29245",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-29245"
},
{
"name": "CVE-2023-43503",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-43503"
},
{
"name": "CVE-2019-12260",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-12260"
},
{
"name": "CVE-2022-23218",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-23218"
},
{
"name": "CVE-2023-28260",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-28260"
},
{
"name": "CVE-2023-43505",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-43505"
},
{
"name": "CVE-2023-38074",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-38074"
},
{
"name": "CVE-2019-12262",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-12262"
},
{
"name": "CVE-2023-29331",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-29331"
},
{
"name": "CVE-2019-12255",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-12255"
},
{
"name": "CVE-2023-44374",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-44374"
},
{
"name": "CVE-2023-43504",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-43504"
},
{
"name": "CVE-2023-0933",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-0933"
},
{
"name": "CVE-2023-2567",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-2567"
},
{
"name": "CVE-2023-32649",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-32649"
},
{
"name": "CVE-2022-41032",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-41032"
},
{
"name": "CVE-2023-4863",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-4863"
},
{
"name": "CVE-2023-21808",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-21808"
},
{
"name": "CVE-2023-2931",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-2931"
},
{
"name": "CVE-2023-2975",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-2975"
},
{
"name": "CVE-2022-30184",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-30184"
},
{
"name": "CVE-2019-12265",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-12265"
},
{
"name": "CVE-2023-44373",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-44373"
},
{
"name": "CVE-2023-3446",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-3446"
},
{
"name": "CVE-2022-23219",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-23219"
},
{
"name": "CVE-2023-38076",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-38076"
},
{
"name": "CVE-2023-41032",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-41032"
},
{
"name": "CVE-2023-33126",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-33126"
},
{
"name": "CVE-2023-44318",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-44318"
},
{
"name": "CVE-2023-22670",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-22670"
}
],
"initial_release_date": "2023-11-14T00:00:00",
"last_revision_date": "2023-11-14T00:00:00",
"links": [],
"reference": "CERTFR-2023-AVI-0935",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2023-11-14T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Injection de code indirecte \u00e0 distance (XSS)"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
},
{
"description": "\u00c9l\u00e9vation de privil\u00e8ges"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans \u003cspan\nclass=\"textit\"\u003eles produits Siemens\u003c/span\u003e. Certaines d\u0027entre elles\npermettent \u00e0 un attaquant de provoquer une \u00e9l\u00e9vation de privil\u00e8ges, un\nd\u00e9ni de service \u00e0 distance et une ex\u00e9cution de code arbitraire \u00e0\ndistance.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Siemens",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-617233 du 14 novembre 2023",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-292063.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-268517 du 14 novembre 2023",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-084182.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-197270 du 14 novembre 2023",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-787941.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-099606 du 14 novembre 2023",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-625850.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-137900 du 14 novembre 2023",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-137900.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-456933 du 14 novembre 2023",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-456933.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-787941 du 14 novembre 2023",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-457702.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-084182 du 14 novembre 2023",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-887122.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-887122 du 08 novembre 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-150063.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-150063 du 14 novembre 2023",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-268517.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-699386 du 14 novembre 2023",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-197270.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-292063 du 14 novembre 2023",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-617233.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-625850 du 14 novembre 2023",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-699386.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-457702 du 14 novembre 2023",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-099606.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-478780 du 14 novembre 2023",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-478780.html"
}
]
}
CERTFR-2024-AVI-0478
Vulnerability from certfr_avis - Published: 2024-06-11 - Updated: 2024-06-11
De multiples vulnérabilités ont été découvertes dans les produits Siemens. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, une élévation de privilèges et un déni de service à distance.
Solutions
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
| Vendor | Product | Description | ||
|---|---|---|---|---|
| Siemens | N/A | SINEC Traffic Analyzer versions antérieures à 1.2 | ||
| Siemens | N/A | SIPLUS ET 200SP CP 1543SP-1 ISEC versions antérieures à 2.3 | ||
| Siemens | N/A | SITOP UPS1600 EX 20 A Ethernet PROFINET versions antérieures à 2.5.4 | ||
| Siemens | N/A | Teamcenter Visualization 14.3 versions antérieures à 14.3.0.9 | ||
| Siemens | N/A | SITOP UPS1600 40 A Ethernet/ PROFINET versions antérieures à 2.5.4 | ||
| Siemens | N/A | PCCX26 Ax 1703 PE, Contr, Communication Element versions antérieures à 06.05 | ||
| Siemens | N/A | Tecnomatix Plant Simulation 2404 versions antérieures à 2404.0001 | ||
| Siemens | N/A | TIM 1531 IRC versions antérieures à 2.4.8 | ||
| Siemens | N/A | CPCX26 Central Processing/Communication versions antérieures à 06.02 | ||
| Siemens | N/A | SITOP UPS1600 20 A Ethernet/ PROFINET versions antérieures à 2.5.4 | ||
| Siemens | N/A | Teamcenter Visualization 2312 versions antérieures à 2312.0004 | ||
| Siemens | N/A | JT2Go versions antérieures à 2312.0004 | ||
| Siemens | N/A | les applications Mendix utilisant Mendix 10 versions antérieures à 10.11.0 | ||
| Siemens | N/A | Tecnomatix Plant Simulation 2302 versions antérieures à 2302.0012 | ||
| Siemens | N/A | SIPLUS TIM 1531 IRC versions antérieures à 2.4.8 | ||
| Siemens | N/A | ETA5 Ethernet Int. 1x100TX IEC61850 Ed.2 versions antérieures à 03.27 | ||
| Siemens | N/A | SITOP UPS1600 10 A Ethernet/ PROFINET versions antérieures à 2.5.4 | ||
| Siemens | N/A | PowerSys versions antérieures à 3.11 | ||
| Siemens | N/A | ETA4 Ethernet Interface IEC60870-5-104 versions antérieures à 10.46 | ||
| Siemens | N/A | TIA Administrator versions antérieures à 3 SP2 | ||
| Siemens | N/A | les applications Mendix utilisant Mendix 9 versions antérieures à 9.24.22 | ||
| Siemens | N/A | ST7 ScadaConnect versions antérieures à 1.1 | ||
| Siemens | N/A | SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL versions antérieures à 2.3 | ||
| Siemens | N/A | Teamcenter Visualization 14.2 toutes versions, aucun correctif n'est disponible | ||
| Siemens | N/A | les produits SCALANCE, se référer au bulletin de sécurité de l'éditeur (cf. section Documentation) | ||
| Siemens | N/A | SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL versions antérieures à 2.3 | ||
| Siemens | N/A | les applications Mendix utilisant Mendix 10.6 versions antérieures à 10.6.9 |
| Title | Publication Time | Tags | ||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||||||||||||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "SINEC Traffic Analyzer versions ant\u00e9rieures \u00e0 1.2",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS ET 200SP CP 1543SP-1 ISEC versions ant\u00e9rieures \u00e0 2.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SITOP UPS1600 EX 20 A Ethernet PROFINET versions ant\u00e9rieures \u00e0 2.5.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Teamcenter Visualization 14.3 versions ant\u00e9rieures \u00e0 14.3.0.9",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SITOP UPS1600 40 A Ethernet/ PROFINET versions ant\u00e9rieures \u00e0 2.5.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "PCCX26 Ax 1703 PE, Contr, Communication Element versions ant\u00e9rieures \u00e0 06.05",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Tecnomatix Plant Simulation 2404 versions ant\u00e9rieures \u00e0 2404.0001",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "TIM 1531 IRC versions ant\u00e9rieures \u00e0 2.4.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "CPCX26 Central Processing/Communication versions ant\u00e9rieures \u00e0 06.02",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SITOP UPS1600 20 A Ethernet/ PROFINET versions ant\u00e9rieures \u00e0 2.5.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Teamcenter Visualization 2312 versions ant\u00e9rieures \u00e0 2312.0004",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "JT2Go versions ant\u00e9rieures \u00e0 2312.0004",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "les applications Mendix utilisant Mendix 10 versions ant\u00e9rieures \u00e0 10.11.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Tecnomatix Plant Simulation 2302 versions ant\u00e9rieures \u00e0 2302.0012",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS TIM 1531 IRC versions ant\u00e9rieures \u00e0 2.4.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "ETA5 Ethernet Int. 1x100TX IEC61850 Ed.2 versions ant\u00e9rieures \u00e0 03.27",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SITOP UPS1600 10 A Ethernet/ PROFINET versions ant\u00e9rieures \u00e0 2.5.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "PowerSys versions ant\u00e9rieures \u00e0 3.11",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "ETA4 Ethernet Interface IEC60870-5-104 versions ant\u00e9rieures \u00e0 10.46",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "TIA Administrator versions ant\u00e9rieures \u00e0 3 SP2",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "les applications Mendix utilisant Mendix 9 versions ant\u00e9rieures \u00e0 9.24.22",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "ST7 ScadaConnect versions ant\u00e9rieures \u00e0 1.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL versions ant\u00e9rieures \u00e0 2.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Teamcenter Visualization 14.2 toutes versions, aucun correctif n\u0027est disponible",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "les produits SCALANCE, se r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur (cf. section Documentation)",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL versions ant\u00e9rieures \u00e0 2.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "les applications Mendix utilisant Mendix 10.6 versions ant\u00e9rieures \u00e0 10.6.9",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
}
],
"affected_systems_content": "",
"content": "## Solutions\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des correctifs (cf. section Documentation).",
"cves": [
{
"name": "CVE-2023-24895",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-24895"
},
{
"name": "CVE-2023-49691",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-49691"
},
{
"name": "CVE-2024-35207",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-35207"
},
{
"name": "CVE-2023-33135",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-33135"
},
{
"name": "CVE-2024-33500",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-33500"
},
{
"name": "CVE-2023-35390",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-35390"
},
{
"name": "CVE-2023-44317",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-44317"
},
{
"name": "CVE-2024-35210",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-35210"
},
{
"name": "CVE-2022-4304",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-4304"
},
{
"name": "CVE-2023-38380",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-38380"
},
{
"name": "CVE-2023-36794",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-36794"
},
{
"name": "CVE-2024-36266",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-36266"
},
{
"name": "CVE-2023-24897",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-24897"
},
{
"name": "CVE-2022-44792",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-44792"
},
{
"name": "CVE-2022-42329",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-42329"
},
{
"name": "CVE-2024-35206",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-35206"
},
{
"name": "CVE-2023-0215",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-0215"
},
{
"name": "CVE-2023-35788",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-35788"
},
{
"name": "CVE-2023-0286",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-0286"
},
{
"name": "CVE-2023-24936",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-24936"
},
{
"name": "CVE-2023-36792",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-36792"
},
{
"name": "CVE-2022-3643",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-3643"
},
{
"name": "CVE-2022-39189",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-39189"
},
{
"name": "CVE-2022-46144",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-46144"
},
{
"name": "CVE-2022-3435",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-3435"
},
{
"name": "CVE-2023-44487",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-44487"
},
{
"name": "CVE-2024-26277",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-26277"
},
{
"name": "CVE-2022-40225",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-40225"
},
{
"name": "CVE-2023-0466",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-0466"
},
{
"name": "CVE-2023-35828",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-35828"
},
{
"name": "CVE-2023-36049",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-36049"
},
{
"name": "CVE-2023-0465",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-0465"
},
{
"name": "CVE-2022-44793",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-44793"
},
{
"name": "CVE-2024-35211",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-35211"
},
{
"name": "CVE-2023-33127",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-33127"
},
{
"name": "CVE-2021-47178",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-47178"
},
{
"name": "CVE-2022-45919",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-45919"
},
{
"name": "CVE-2023-33170",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-33170"
},
{
"name": "CVE-2023-33128",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-33128"
},
{
"name": "CVE-2023-41910",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-41910"
},
{
"name": "CVE-2023-28484",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-28484"
},
{
"name": "CVE-2023-28319",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-28319"
},
{
"name": "CVE-2022-45886",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-45886"
},
{
"name": "CVE-2022-1015",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-1015"
},
{
"name": "CVE-2023-27321",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-27321"
},
{
"name": "CVE-2024-31484",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-31484"
},
{
"name": "CVE-2023-0464",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-0464"
},
{
"name": "CVE-2022-41742",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-41742"
},
{
"name": "CVE-2022-3545",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-3545"
},
{
"name": "CVE-2023-26552",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-26552"
},
{
"name": "CVE-2023-29469",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-29469"
},
{
"name": "CVE-2023-0160",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-0160"
},
{
"name": "CVE-2024-35212",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-35212"
},
{
"name": "CVE-2022-40303",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-40303"
},
{
"name": "CVE-2023-21255",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-21255"
},
{
"name": "CVE-2024-26275",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-26275"
},
{
"name": "CVE-2023-38180",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-38180"
},
{
"name": "CVE-2023-35824",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-35824"
},
{
"name": "CVE-2024-35209",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-35209"
},
{
"name": "CVE-2022-42328",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-42328"
},
{
"name": "CVE-2023-35823",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-35823"
},
{
"name": "CVE-2023-38178",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-38178"
},
{
"name": "CVE-2022-45887",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-45887"
},
{
"name": "CVE-2024-0775",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-0775"
},
{
"name": "CVE-2023-44319",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-44319"
},
{
"name": "CVE-2023-32032",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-32032"
},
{
"name": "CVE-2022-4450",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-4450"
},
{
"name": "CVE-2023-26554",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-26554"
},
{
"name": "CVE-2023-2269",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-2269"
},
{
"name": "CVE-2024-35208",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-35208"
},
{
"name": "CVE-2024-26276",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-26276"
},
{
"name": "CVE-2023-1017",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-1017"
},
{
"name": "CVE-2023-38171",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-38171"
},
{
"name": "CVE-2023-28260",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-28260"
},
{
"name": "CVE-2023-50763",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-50763"
},
{
"name": "CVE-2022-3623",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-3623"
},
{
"name": "CVE-2022-2097",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-2097"
},
{
"name": "CVE-2023-29331",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-29331"
},
{
"name": "CVE-2023-44374",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-44374"
},
{
"name": "CVE-2023-38533",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-38533"
},
{
"name": "CVE-2023-35829",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-35829"
},
{
"name": "CVE-2023-36038",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-36038"
},
{
"name": "CVE-2023-21808",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-21808"
},
{
"name": "CVE-2023-36799",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-36799"
},
{
"name": "CVE-2023-36435",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-36435"
},
{
"name": "CVE-2023-26553",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-26553"
},
{
"name": "CVE-2022-40304",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-40304"
},
{
"name": "CVE-2023-35391",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-35391"
},
{
"name": "CVE-2023-44373",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-44373"
},
{
"name": "CVE-2023-39615",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-39615"
},
{
"name": "CVE-2023-36796",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-36796"
},
{
"name": "CVE-2023-3446",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-3446"
},
{
"name": "CVE-2024-35303",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-35303"
},
{
"name": "CVE-2023-5678",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-5678"
},
{
"name": "CVE-2024-35292",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-35292"
},
{
"name": "CVE-2023-36558",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-36558"
},
{
"name": "CVE-2023-2124",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-2124"
},
{
"name": "CVE-2023-33126",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-33126"
},
{
"name": "CVE-2023-52474",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-52474"
},
{
"name": "CVE-2023-44318",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-44318"
},
{
"name": "CVE-2023-36793",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-36793"
}
],
"initial_release_date": "2024-06-11T00:00:00",
"last_revision_date": "2024-06-11T00:00:00",
"links": [],
"reference": "CERTFR-2024-AVI-0478",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2024-06-11T00:00:00.000000"
}
],
"risks": [
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "\u00c9l\u00e9vation de privil\u00e8ges"
},
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Injection de requ\u00eates ill\u00e9gitimes par rebond (CSRF)"
},
{
"description": "Non sp\u00e9cifi\u00e9 par l\u0027\u00e9diteur"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits Siemens. Certaines d\u0027entre elles permettent \u00e0 un attaquant de provoquer une ex\u00e9cution de code arbitraire \u00e0 distance, une \u00e9l\u00e9vation de privil\u00e8ges et un d\u00e9ni de service \u00e0 distance.",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Siemens",
"vendor_advisories": [
{
"published_at": "2024-06-11",
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-900277",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-900277.html"
},
{
"published_at": "2024-06-11",
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-620338",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-620338.html"
},
{
"published_at": "2024-06-11",
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-540640",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-540640.html"
},
{
"published_at": "2024-06-11",
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-238730",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-238730.html"
},
{
"published_at": "2024-06-11",
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-319319",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-319319.html"
},
{
"published_at": "2024-06-11",
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-879734",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-879734.html"
},
{
"published_at": "2024-06-11",
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-625862",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-625862.html"
},
{
"published_at": "2024-06-11",
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-481506",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-481506.html"
},
{
"published_at": "2024-06-11",
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-024584",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-024584.html"
},
{
"published_at": "2024-06-11",
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-196737",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-196737.html"
},
{
"published_at": "2024-06-11",
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-337522",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-337522.html"
},
{
"published_at": "2024-06-11",
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-341067",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-341067.html"
},
{
"published_at": "2024-06-11",
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-771940",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-771940.html"
},
{
"published_at": "2024-06-11",
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-690517",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-690517.html"
}
]
}
FKIE_CVE-2022-44793
Vulnerability from fkie_nvd - Published: 2022-11-07 03:15 - Updated: 2025-05-05 16:156.5 (Medium) - CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H
| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | https://gist.github.com/menglong2234/d07a65b5028145c9f4e1d1db8c4c202f | Exploit, Third Party Advisory | |
| cve@mitre.org | https://github.com/net-snmp/net-snmp/issues/475 | Exploit, Issue Tracking, Third Party Advisory | |
| cve@mitre.org | https://lists.debian.org/debian-lts-announce/2023/01/msg00010.html | Mailing List, Third Party Advisory | |
| cve@mitre.org | https://security.netapp.com/advisory/ntap-20230223-0011/ | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://gist.github.com/menglong2234/d07a65b5028145c9f4e1d1db8c4c202f | Exploit, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://github.com/net-snmp/net-snmp/issues/475 | Exploit, Issue Tracking, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://lists.debian.org/debian-lts-announce/2023/01/msg00010.html | Mailing List, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://security.netapp.com/advisory/ntap-20230223-0011/ | Third Party Advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| net-snmp | net-snmp | * | |
| debian | debian_linux | 10.0 | |
| netapp | h300s_firmware | - | |
| netapp | h300s | - | |
| netapp | h500s_firmware | - | |
| netapp | h500s | - | |
| netapp | h700s_firmware | - | |
| netapp | h700s | - | |
| netapp | h410s_firmware | - | |
| netapp | h410s | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:net-snmp:net-snmp:*:*:*:*:*:*:*:*",
"matchCriteriaId": "97E267EC-2F41-4233-8647-3BE21B487713",
"versionEndIncluding": "5.9.3",
"versionStartIncluding": "5.4.3",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:debian:debian_linux:10.0:*:*:*:*:*:*:*",
"matchCriteriaId": "07B237A9-69A3-4A9C-9DA0-4E06BD37AE73",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netapp:h300s_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "6770B6C3-732E-4E22-BF1C-2D2FD610061C",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netapp:h300s:-:*:*:*:*:*:*:*",
"matchCriteriaId": "9F9C8C20-42EB-4AB5-BD97-212DEB070C43",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netapp:h500s_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7FFF7106-ED78-49BA-9EC5-B889E3685D53",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netapp:h500s:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E63D8B0F-006E-4801-BF9D-1C001BBFB4F9",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netapp:h700s_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "56409CEC-5A1E-4450-AA42-641E459CC2AF",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netapp:h700s:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B06F4839-D16A-4A61-9BB5-55B13F41E47F",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netapp:h410s_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D0B4AD8A-F172-4558-AEC6-FF424BA2D912",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netapp:h410s:-:*:*:*:*:*:*:*",
"matchCriteriaId": "8497A4C9-8474-4A62-8331-3FE862ED4098",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "handle_ipv6IpForwarding in agent/mibgroup/ip-mib/ip_scalars.c in Net-SNMP 5.4.3 through 5.9.3 has a NULL Pointer Exception bug that can be used by a remote attacker to cause the instance to crash via a crafted UDP packet, resulting in Denial of Service."
},
{
"lang": "es",
"value": "handle_ipv6IpForwarding en agent/mibgroup/ip-mib/ip_scalars.c en Net-SNMP 5.4.3 a 5.9.3 tiene un error de excepci\u00f3n de puntero NULL que puede ser utilizado por un atacante remoto para provocar que la instancia se bloquee a trav\u00e9s de un paquete UDP manipulado. resultando en Denegaci\u00f3n de Servicio."
}
],
"id": "CVE-2022-44793",
"lastModified": "2025-05-05T16:15:22.427",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
},
"published": "2022-11-07T03:15:09.363",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://gist.github.com/menglong2234/d07a65b5028145c9f4e1d1db8c4c202f"
},
{
"source": "cve@mitre.org",
"tags": [
"Exploit",
"Issue Tracking",
"Third Party Advisory"
],
"url": "https://github.com/net-snmp/net-snmp/issues/475"
},
{
"source": "cve@mitre.org",
"tags": [
"Mailing List",
"Third Party Advisory"
],
"url": "https://lists.debian.org/debian-lts-announce/2023/01/msg00010.html"
},
{
"source": "cve@mitre.org",
"tags": [
"Third Party Advisory"
],
"url": "https://security.netapp.com/advisory/ntap-20230223-0011/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://gist.github.com/menglong2234/d07a65b5028145c9f4e1d1db8c4c202f"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Issue Tracking",
"Third Party Advisory"
],
"url": "https://github.com/net-snmp/net-snmp/issues/475"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Mailing List",
"Third Party Advisory"
],
"url": "https://lists.debian.org/debian-lts-announce/2023/01/msg00010.html"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://security.netapp.com/advisory/ntap-20230223-0011/"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-476"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-476"
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
}
GHSA-GG4C-VQ6J-H4HR
Vulnerability from github – Published: 2022-11-07 12:00 – Updated: 2025-05-05 18:32handle_ipv6IpForwarding in agent/mibgroup/ip-mib/ip_scalars.c in Net-SNMP 5.4.3 through 5.9.3 has a NULL Pointer Exception bug that can be used by a remote attacker to cause the instance to crash via a crafted UDP packet, resulting in Denial of Service.
{
"affected": [],
"aliases": [
"CVE-2022-44793"
],
"database_specific": {
"cwe_ids": [
"CWE-476"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2022-11-07T03:15:00Z",
"severity": "MODERATE"
},
"details": "handle_ipv6IpForwarding in agent/mibgroup/ip-mib/ip_scalars.c in Net-SNMP 5.4.3 through 5.9.3 has a NULL Pointer Exception bug that can be used by a remote attacker to cause the instance to crash via a crafted UDP packet, resulting in Denial of Service.",
"id": "GHSA-gg4c-vq6j-h4hr",
"modified": "2025-05-05T18:32:28Z",
"published": "2022-11-07T12:00:34Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2022-44793"
},
{
"type": "WEB",
"url": "https://github.com/net-snmp/net-snmp/issues/475"
},
{
"type": "WEB",
"url": "https://gist.github.com/menglong2234/d07a65b5028145c9f4e1d1db8c4c202f"
},
{
"type": "WEB",
"url": "https://lists.debian.org/debian-lts-announce/2023/01/msg00010.html"
},
{
"type": "WEB",
"url": "https://security.netapp.com/advisory/ntap-20230223-0011"
}
],
"schema_version": "1.4.0",
"severity": [
{
"score": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H",
"type": "CVSS_V3"
}
]
}
GSD-2022-44793
Vulnerability from gsd - Updated: 2023-12-13 01:19{
"GSD": {
"alias": "CVE-2022-44793",
"description": "handle_ipv6IpForwarding in agent/mibgroup/ip-mib/ip_scalars.c in Net-SNMP 5.4.3 through 5.9.3 has a NULL Pointer Exception bug that can be used by a remote attacker to cause the instance to crash via a crafted UDP packet, resulting in Denial of Service.",
"id": "GSD-2022-44793",
"references": [
"https://www.suse.com/security/cve/CVE-2022-44793.html",
"https://ubuntu.com/security/CVE-2022-44793",
"https://advisories.mageia.org/CVE-2022-44793.html"
]
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2022-44793"
],
"details": "handle_ipv6IpForwarding in agent/mibgroup/ip-mib/ip_scalars.c in Net-SNMP 5.4.3 through 5.9.3 has a NULL Pointer Exception bug that can be used by a remote attacker to cause the instance to crash via a crafted UDP packet, resulting in Denial of Service.",
"id": "GSD-2022-44793",
"modified": "2023-12-13T01:19:25.042811Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2022-44793",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "handle_ipv6IpForwarding in agent/mibgroup/ip-mib/ip_scalars.c in Net-SNMP 5.4.3 through 5.9.3 has a NULL Pointer Exception bug that can be used by a remote attacker to cause the instance to crash via a crafted UDP packet, resulting in Denial of Service."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://github.com/net-snmp/net-snmp/issues/475",
"refsource": "MISC",
"url": "https://github.com/net-snmp/net-snmp/issues/475"
},
{
"name": "https://gist.github.com/menglong2234/d07a65b5028145c9f4e1d1db8c4c202f",
"refsource": "MISC",
"url": "https://gist.github.com/menglong2234/d07a65b5028145c9f4e1d1db8c4c202f"
},
{
"name": "[debian-lts-announce] 20230115 [SECURITY] [DLA 3270-1] net-snmp security update",
"refsource": "MLIST",
"url": "https://lists.debian.org/debian-lts-announce/2023/01/msg00010.html"
},
{
"name": "https://security.netapp.com/advisory/ntap-20230223-0011/",
"refsource": "CONFIRM",
"url": "https://security.netapp.com/advisory/ntap-20230223-0011/"
}
]
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:net-snmp:net-snmp:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "5.9.3",
"versionStartIncluding": "5.4.3",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:debian:debian_linux:10.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:netapp:h300s_firmware:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:netapp:h300s:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:netapp:h500s_firmware:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:netapp:h500s:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:netapp:h700s_firmware:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:netapp:h700s:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:netapp:h410s_firmware:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:netapp:h410s:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2022-44793"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "handle_ipv6IpForwarding in agent/mibgroup/ip-mib/ip_scalars.c in Net-SNMP 5.4.3 through 5.9.3 has a NULL Pointer Exception bug that can be used by a remote attacker to cause the instance to crash via a crafted UDP packet, resulting in Denial of Service."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-476"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://github.com/net-snmp/net-snmp/issues/475",
"refsource": "MISC",
"tags": [
"Exploit",
"Issue Tracking",
"Third Party Advisory"
],
"url": "https://github.com/net-snmp/net-snmp/issues/475"
},
{
"name": "https://gist.github.com/menglong2234/d07a65b5028145c9f4e1d1db8c4c202f",
"refsource": "MISC",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://gist.github.com/menglong2234/d07a65b5028145c9f4e1d1db8c4c202f"
},
{
"name": "[debian-lts-announce] 20230115 [SECURITY] [DLA 3270-1] net-snmp security update",
"refsource": "MLIST",
"tags": [
"Mailing List",
"Third Party Advisory"
],
"url": "https://lists.debian.org/debian-lts-announce/2023/01/msg00010.html"
},
{
"name": "https://security.netapp.com/advisory/ntap-20230223-0011/",
"refsource": "CONFIRM",
"tags": [
"Third Party Advisory"
],
"url": "https://security.netapp.com/advisory/ntap-20230223-0011/"
}
]
}
},
"impact": {
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6
}
},
"lastModifiedDate": "2023-03-28T17:17Z",
"publishedDate": "2022-11-07T03:15Z"
}
}
}
ICSA-23-320-13
Vulnerability from csaf_cisa - Published: 2023-11-14 00:00 - Updated: 2023-11-14 00:00| URL | Category |
|---|---|
| https://cert-portal.siemens.com/productcert/csaf/… | self |
| https://cert-portal.siemens.com/productcert/html/… | self |
| https://cert-portal.siemens.com/productcert/pdf/s… | self |
| https://cert-portal.siemens.com/productcert/txt/s… | self |
| https://raw.githubusercontent.com/cisagov/CSAF/de… | self |
| https://www.cisa.gov/news-events/ics-advisories/i… | self |
| https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-… | external |
| https://www.cisa.gov/resources-tools/resources/ic… | external |
| https://www.cisa.gov/topics/industrial-control-systems | external |
| https://us-cert.cisa.gov/sites/default/files/reco… | external |
| https://www.cisa.gov/sites/default/files/publicat… | external |
| https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B | external |
{
"document": {
"acknowledgments": [
{
"organization": "Siemens ProductCERT",
"summary": "reporting these vulnerabilities to CISA."
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"lang": "en",
"notes": [
{
"category": "summary",
"text": "SIMATIC MV500 before V3.3.5 is affected by multiple vulnerabilities.\n\nSiemens has released an update for SIMATIC MV500 and recommends to update to the latest version.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
"title": "Terms of Use"
},
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "other",
"text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.",
"title": "Advisory Conversion Disclaimer"
},
{
"category": "other",
"text": "Multiple",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "Germany",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
}
],
"publisher": {
"category": "other",
"contact_details": "central@cisa.dhs.gov",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "SSA-099606: Multiple Vulnerabilities in SIMATIC MV500 before V3.3.5 - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-099606.json"
},
{
"category": "self",
"summary": "SSA-099606: Multiple Vulnerabilities in SIMATIC MV500 before V3.3.5 - HTML Version",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-099606.html"
},
{
"category": "self",
"summary": "SSA-099606: Multiple Vulnerabilities in SIMATIC MV500 before V3.3.5 - PDF Version",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-099606.pdf"
},
{
"category": "self",
"summary": "SSA-099606: Multiple Vulnerabilities in SIMATIC MV500 before V3.3.5 - TXT Version",
"url": "https://cert-portal.siemens.com/productcert/txt/ssa-099606.txt"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-23-320-13 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2023/icsa-23-320-13.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-23-320-13 - Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-320-13"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/topics/industrial-control-systems"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B"
}
],
"title": "Siemens SIMATIC MV500",
"tracking": {
"current_release_date": "2023-11-14T00:00:00.000000Z",
"generator": {
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-23-320-13",
"initial_release_date": "2023-11-14T00:00:00.000000Z",
"revision_history": [
{
"date": "2023-11-14T00:00:00.000000Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
}
],
"status": "final",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cV3.3.5",
"product": {
"name": "SIMATIC MV500 family",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "SIMATIC MV500 family"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2022-23218",
"cwe": {
"id": "CWE-120",
"name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)"
},
"notes": [
{
"category": "summary",
"text": "The deprecated compatibility function svcunix_create in the sunrpc module of the GNU C Library (aka glibc) through 2.34 copies its path argument on the stack without validating its length, which may result in a buffer overflow, potentially resulting in a denial of service or (if an application is not built with a stack protector enabled) arbitrary code execution.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V3.3.5 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109825816/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2022-23218"
},
{
"cve": "CVE-2022-23219",
"cwe": {
"id": "CWE-120",
"name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)"
},
"notes": [
{
"category": "summary",
"text": "The deprecated compatibility function clnt_create in the sunrpc module of the GNU C Library (aka glibc) through 2.34 copies its hostname argument on the stack without validating its length, which may result in a buffer overflow, potentially resulting in a denial of service or (if an application is not built with a stack protector enabled) arbitrary code execution.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V3.3.5 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109825816/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2022-23219"
},
{
"cve": "CVE-2022-44792",
"cwe": {
"id": "CWE-476",
"name": "NULL Pointer Dereference"
},
"notes": [
{
"category": "summary",
"text": "handle_ipDefaultTTL in agent/mibgroup/ip-mib/ip_scalars.c in Net-SNMP 5.8 through 5.9.3 has a NULL Pointer Exception bug that can be used by a remote attacker (who has write access) to cause the instance to crash via a crafted UDP packet, resulting in Denial of Service.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V3.3.5 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109825816/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2022-44792"
},
{
"cve": "CVE-2022-44793",
"cwe": {
"id": "CWE-476",
"name": "NULL Pointer Dereference"
},
"notes": [
{
"category": "summary",
"text": "handle_ipv6IpForwarding in agent/mibgroup/ip-mib/ip_scalars.c in Net-SNMP 5.4.3 through 5.9.3 has a NULL Pointer Exception bug that can be used by a remote attacker to cause the instance to crash via a crafted UDP packet, resulting in Denial of Service.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V3.3.5 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109825816/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2022-44793"
},
{
"cve": "CVE-2023-2975",
"cwe": {
"id": "CWE-287",
"name": "Improper Authentication"
},
"notes": [
{
"category": "summary",
"text": "Issue summary: The AES-SIV cipher implementation contains a bug that causes it to ignore empty associated data entries which are unauthenticated as a consequence. Impact summary: Applications that use the AES-SIV algorithm and want to authenticate empty data entries as associated data can be mislead by removing adding or reordering such empty entries as these are ignored by the OpenSSL implementation. We are currently unaware of any such applications. The AES-SIV algorithm allows for authentication of multiple associated data entries along with the encryption. To authenticate empty data the application has to call EVP_EncryptUpdate() (or EVP_CipherUpdate()) with NULL pointer as the output buffer and 0 as the input buffer length. The AES-SIV implementation in OpenSSL just returns success for such a call instead of performing the associated data authentication operation. The empty data thus will not be authenticated. As this issue does not affect non-empty associated data authentication and we expect it to be rare for an application to use empty associated data entries this is qualified as Low severity issue.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V3.3.5 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109825816/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2023-2975"
},
{
"cve": "CVE-2023-3446",
"cwe": {
"id": "CWE-1333",
"name": "Inefficient Regular Expression Complexity"
},
"notes": [
{
"category": "summary",
"text": "Issue summary: Checking excessively long DH keys or parameters may be very slow. Impact summary: Applications that use the functions DH_check(), DH_check_ex() or EVP_PKEY_param_check() to check a DH key or DH parameters may experience long delays. Where the key or parameters that are being checked have been obtained from an untrusted source this may lead to a Denial of Service. The function DH_check() performs various checks on DH parameters. One of those checks confirms that the modulus (\u0027p\u0027 parameter) is not too large. Trying to use a very large modulus is slow and OpenSSL will not normally use a modulus which is over 10,000 bits in length. However the DH_check() function checks numerous aspects of the key or parameters that have been supplied. Some of those checks use the supplied modulus value even if it has already been found to be too large. An application that calls DH_check() and supplies a key or parameters obtained from an untrusted source could be vulernable to a Denial of Service attack. The function DH_check() is itself called by a number of other OpenSSL functions. An application calling any of those other functions may similarly be affected. The other functions affected by this are DH_check_ex() and EVP_PKEY_param_check(). Also vulnerable are the OpenSSL dhparam and pkeyparam command line applications when using the \u0027-check\u0027 option. The OpenSSL SSL/TLS implementation is not affected by this issue. The OpenSSL 3.0 and 3.1 FIPS providers are not affected by this issue.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V3.3.5 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109825816/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2023-3446"
},
{
"cve": "CVE-2023-3817",
"cwe": {
"id": "CWE-834",
"name": "Excessive Iteration"
},
"notes": [
{
"category": "summary",
"text": "Issue summary: Checking excessively long DH keys or parameters may be very slow. Impact summary: Applications that use the functions DH_check(), DH_check_ex() or EVP_PKEY_param_check() to check a DH key or DH parameters may experience long delays. Where the key or parameters that are being checked have been obtained from an untrusted source this may lead to a Denial of Service. The function DH_check() performs various checks on DH parameters. After fixing CVE-2023-3446 it was discovered that a large q parameter value can also trigger an overly long computation during some of these checks. A correct q value, if present, cannot be larger than the modulus p parameter, thus it is unnecessary to perform these checks if q is larger than p. An application that calls DH_check() and supplies a key or parameters obtained from an untrusted source could be vulnerable to a Denial of Service attack. The function DH_check() is itself called by a number of other OpenSSL functions. An application calling any of those other functions may similarly be affected. The other functions affected by this are DH_check_ex() and EVP_PKEY_param_check(). Also vulnerable are the OpenSSL dhparam and pkeyparam command line applications when using the \"-check\" option. The OpenSSL SSL/TLS implementation is not affected by this issue. The OpenSSL 3.0 and 3.1 FIPS providers are not affected by this issue.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V3.3.5 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109825816/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2023-3817"
},
{
"cve": "CVE-2023-35788",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "An issue was discovered in fl_set_geneve_opt in net/sched/cls_flower.c in the Linux kernel before 6.3.7. It allows an out-of-bounds write in the flower classifier code via TCA_FLOWER_KEY_ENC_OPTS_GENEVE packets. This may result in denial of service or privilege escalation.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V3.3.5 or later version",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109825816/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001"
]
}
],
"title": "CVE-2023-35788"
}
]
}
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.