CVE-2022-27841 (GCVE-0-2022-27841)
Vulnerability from cvelistv5 – Published: 2022-04-11 19:37 – Updated: 2024-08-03 05:41
VLAI?
Summary
Improper exception handling in Samsung Pass prior to version 3.7.07.5 allows physical attacker to view the screen that is previously running without authentication
Severity ?
4.3 (Medium)
CWE
- CWE-703 - Improper Check or Handling of Exceptional Conditions
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Samsung Mobile | Samsung Pass |
Affected:
- , < 3.0.07.5
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T05:41:09.891Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://security.samsungmobile.com/serviceWeb.smsb?year=2022\u0026month=4"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Samsung Pass",
"vendor": "Samsung Mobile",
"versions": [
{
"lessThan": "3.0.07.5",
"status": "affected",
"version": "-",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Improper exception handling in Samsung Pass prior to version 3.7.07.5 allows physical attacker to view the screen that is previously running without authentication"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "PHYSICAL",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-703",
"description": "CWE-703: Improper Check or Handling of Exceptional Conditions",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-04-11T19:37:33",
"orgId": "3af57064-a867-422c-b2ad-40307b65c458",
"shortName": "Samsung Mobile"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://security.samsungmobile.com/serviceWeb.smsb?year=2022\u0026month=4"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "mobile.security@samsung.com",
"ID": "CVE-2022-27841",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Samsung Pass",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "-",
"version_value": "3.0.07.5"
}
]
}
}
]
},
"vendor_name": "Samsung Mobile"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Improper exception handling in Samsung Pass prior to version 3.7.07.5 allows physical attacker to view the screen that is previously running without authentication"
}
]
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "PHYSICAL",
"availabilityImpact": "NONE",
"baseScore": 4.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-703: Improper Check or Handling of Exceptional Conditions"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://security.samsungmobile.com/serviceWeb.smsb?year=2022\u0026month=4",
"refsource": "MISC",
"url": "https://security.samsungmobile.com/serviceWeb.smsb?year=2022\u0026month=4"
}
]
},
"source": {
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "3af57064-a867-422c-b2ad-40307b65c458",
"assignerShortName": "Samsung Mobile",
"cveId": "CVE-2022-27841",
"datePublished": "2022-04-11T19:37:33",
"dateReserved": "2022-03-24T00:00:00",
"dateUpdated": "2024-08-03T05:41:09.891Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"nvd": "{\"cve\":{\"id\":\"CVE-2022-27841\",\"sourceIdentifier\":\"mobile.security@samsung.com\",\"published\":\"2022-04-11T20:15:23.203\",\"lastModified\":\"2024-11-21T06:56:17.877\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Improper exception handling in Samsung Pass prior to version 3.7.07.5 allows physical attacker to view the screen that is previously running without authentication\"},{\"lang\":\"es\",\"value\":\"Un manejo inapropiado de excepciones en Samsung Pass versiones anteriores a 3.7.07.5, permite a un atacante f\u00edsico visualizar la pantalla que est\u00e1 siendo ejecutada previamente sin autenticaci\u00f3n\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"mobile.security@samsung.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:P/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N\",\"baseScore\":4.3,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"PHYSICAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":0.7,\"impactScore\":3.6},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:P/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N\",\"baseScore\":4.3,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"PHYSICAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":0.7,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:L/AC:M/Au:N/C:P/I:N/A:N\",\"baseScore\":1.9,\"accessVector\":\"LOCAL\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"LOW\",\"exploitabilityScore\":3.4,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"mobile.security@samsung.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-703\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-755\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:samsung:samsung_pass:*:*:*:*:*:android:*:*\",\"versionEndExcluding\":\"3.7.07.5\",\"matchCriteriaId\":\"F98FBA30-B0EB-466F-8C6F-F0A820EC9629\"}]}]}],\"references\":[{\"url\":\"https://security.samsungmobile.com/serviceWeb.smsb?year=2022\u0026month=4\",\"source\":\"mobile.security@samsung.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://security.samsungmobile.com/serviceWeb.smsb?year=2022\u0026month=4\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}"
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…